• 제목/요약/키워드: chemical signal

검색결과 592건 처리시간 0.029초

Towards the Reconstruction of Time-dependent Vibronic States from Nonlinear Wavepacket Interferometry Signals

  • Humble, Travis S.;Cina, Jeffrey A.
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권8호
    • /
    • pp.1111-1118
    • /
    • 2003
  • We present one-color nonlinear wavepacket interferometry (WPI) signal calculations for a system of two electronic levels and one vibrational degree of freedom. We consider two cases, a displaced harmonic oscillator system, which can be treated analytically, and a model photodissociative system, whose WPI signal must be calculated by numerical wavepacket propagation. We show how signals obtained with different combinations of intrapulse-pair phase shifts can be combined to isolate the complex-valued overlap between a given onepulse target wavepacket and a variable three-pulse reference wavepacket. We demonstrate that with a range of inter- and intrapulse-pair delays the complex overlaps and variable reference states can be used to reconstruct the target wavepacket. We compare our results with previous methods for vibronic state reconstruction based on linear WPI and discuss further generalizations of our method.

Expression of Thermostable $\alpha$-Glucosidase from Thermus caldophilus GK24 in Recombinant Saccharomyces cerevisiae

  • Choi, Jae-Youl;Ahn, Jung-Oh;Kim, Sun-Il;Shin, Hyun-Jae
    • Journal of Microbiology and Biotechnology
    • /
    • 제16권12호
    • /
    • pp.2000-2003
    • /
    • 2006
  • A gene (GenBank AF096282) coding for a $\alpha$-glucosidase (TcaAG, EC 3.2.1.20) from Thermus caldophilus GK24 was expressed in Saccharomyces cerevisiae, a generally recognized as safe (GRAS) host. The thermostable $\alpha$-glucosidase was produced inside of the GRAS host at 0.04 unit/mg-dry cell by the constitutively expressing ADH1 promoter and at 1.2 unit/mg-dry cell by the inductively expressing GALl0 promoter, respectively. No $\alpha$-glucosidase activities were found in the medium when the MF-alpha signal sequence from S. cerevisiae or $\alpha$-amylase signal sequence from Aspergillus oryzae were fused before the $\alpha$-glucosidase gene for the secretion.

Determination of Doping Density in GaAs Semiconductor by Wavelength-Dependent Photoacoustic Spectroscopy

  • Lim, Jong-Tae;Choi, Ok-Lim;Boo, Doo Wan;Choi, Joong-Gill
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권3호
    • /
    • pp.895-898
    • /
    • 2014
  • The wavelength dependence of the photoacoustic signal for n-type GaAs semiconductors in the region of the band-gap energies was investigated. The significant changes in the phase and amplitude of the photoacoustic signal near the band-gap absorption wavelengths were observed to occur when the Si-doping densities in GaAs were varied. Particularly, the first derivatives of the photoacoustic phase vs. wavelength graphs were evaluated and fitted with single Gaussian functions. The peak centers and the widths of the Gaussian curves clearly showed linear relationships with the log values of the Si-doping densities in n-type GaAs semiconductors. It is proposed that the wavelength-dependent PA spectroscopy can be used as a simple and nondestructive method for measuring the doping densities in bulk semiconductors.

Distinct Mechanisms of DNA Sensing Based on N-Doped Carbon Nanotubes with Enhanced Conductance and Chemical Selectivity

  • Kim, Han Seul;Lee, Seung Jin;Kim, Yong-Hoon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.415.1-415.1
    • /
    • 2014
  • Carrying out first-principles calculations, we study N-doped capped carbon nanotube (CNT) electrodes applied to DNA sequencing. While we obtain for the face-on nucleobase junction configurations a conventional conductance ordering where the largest signal results from guanine according to its high highest occupied molecular orbital (HOMO) level, we extract for the edge-on counterparts a distinct conductance ordering where the low-HOMO thymine provides the largest signal. The edge-on mode is shown to operate based on a novel molecular sensing mechanism that reflects the chemical connectivity between N-doped CNT caps that can act both as electron donors and electron acceptors and DNA functional groups that include the hyperconjugated thymine methyl group[1].

  • PDF

Sampling Methods for Quantification of Solid-state Phases in Powder Samples with Solid-state NMR Spectroscopy

  • Han, Oc-Hee;Kim, Sun-Ha;Ko, Tae-Jung
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권5호
    • /
    • pp.1077-1079
    • /
    • 2009
  • To minimize the variance in the quantification of solid-state phases in powder samples, gently placing polycrystalline samples one next to another directly in a sample holder is better than trying to mix them homogeneously prior to transferring to a sample holder. However, the solid-state cross polarization-magic angle spinning (CP-MAS) nuclear magnetic resonance (NMR) spectroscopy results demonstrated that it is essential in this sampling method to place all the samples in the location of consistent signal sensitivity. The same sampling method may be employed in other spectroscopic quantification techniques of solid-state phases if the method to limit the sample to the location with uniform signal sensitivity in the sample holder is adapted to each technique.

이온젤 전해질 절연체 기반 고분자 비휘발성 메모리 트랜지스터 (Ion Gel Gate Dielectrics for Polymer Non-volatile Transistor Memories)

  • 조보은;강문성
    • 한국전기전자재료학회논문지
    • /
    • 제29권12호
    • /
    • pp.759-763
    • /
    • 2016
  • We demonstrate the utilization of ion gel gate dielectrics for operating non-volatile transistor memory devices based on polymer semiconductor thin films. The gating process in typical electrolyte-gated polymer transistors occurs upon the penetration and escape of ionic components into the active channel layer, which dopes and dedopes the polymer film, respectively. Therefore, by controlling doping and dedoping processes, electrical current signals through the polymer film can be memorized and erased over a period of time, which constitutes the transistor-type memory devices. It was found that increasing the thickness of polymer films can enhance the memory performance of device including (i) the current signal ratio between its memorized state and erased state and (ii) the retention time of the signal.

Fourier Transform 분광기를 이용한 불안정한 분자의 방출분광학 (Emission Spectroscopy of Unstable Molecules using a Fourier Transform Spectrometer)

  • 이상국;김은식
    • 대한화학회지
    • /
    • 제37권4호
    • /
    • pp.371-377
    • /
    • 1993
  • 불안정한 분자의 방출분광학에 상요이 가능하도록 Fourier Transform 분광기를 변형시켰다. 불안정한 분자 라디칼 $CH_3S$는 고전압 직류 방전에 의한 supersonic expansion 속에서 jet 형태의 흐름으로 생성되었다. Supersonic expansion에 의하여 냉각된 라디칼의 형광 스펙트럼은 Fourier Transform UV/VIS 분광기에 의해서 얻어졌다. 스펙트럼의 signal/noise 비율은 증가하였으며, 분자 라디칼 $CH_3S$의 회전구조도 명확하게 볼 수 있었다.

  • PDF

다구치 방법에 의한 ASTM(F136-96)의 절삭인자 분석과 신뢰성 평가 (A Study of Cutting Factor Analysis and Reliability Evaluation of ASTM(F136-96) Material by Taguchi Method)

  • 장성민;윤여권
    • 한국안전학회지
    • /
    • 제23권6호
    • /
    • pp.1-6
    • /
    • 2008
  • Machine operator and quality are affected by chip during cutting process to product machine parts. This paper presents a study of the influence of cutting conditions on the surface roughness obtained by turning using Taguchi method for safety of turning operator. In the machining of titanium alloy, high cutting temperature and strong chemical affinity between the tool and the work material are generated because of its low thermal conductivity and chemical reactivity. Therefore titanium alloys are known as difficult-to materials. An orthogonal array, the signal-to-noise ratio, the analysis of variance are employed to investigate the cutting characteristics of implant material bars using tungsten carbide cutting tools of throwaway type. Also Experimental results by orthogonal array are compared with optimal condition to evaluate advanced reliability. Required simulations and experiments are performed, and the results are investigated.

Retrospective dosimetry using fingernail electron paramagnetic resonance response

  • Noori, Abbas;Mostajaboddavati, Mojtaba;Ziaie, Farhood
    • Nuclear Engineering and Technology
    • /
    • 제50권3호
    • /
    • pp.526-530
    • /
    • 2018
  • Human fingernails were used to estimate the radiation dose via electron paramagnetic resonance measurements of radiation-induced radicals. The limiting factors in this research were mechanically induced electron paramagnetic resonance signals due to the mechanical stress during the preparation of the samples. Therefore, different treatment methods of fingernails were used to reduce the mechanically induced signals. The results demonstrate that the mechanically induced and radiation-induced signals have apparently different microwave power saturation behaviors. In addition, the mechanically induced signal shows a fading evolution over time and reaches a constant value. Chemical treatment using the different reagents showed that the minimum mechanically induced signal was obtained using the dithiothreitol reagent. The dose-response curves of the samples treated with dithiothreitol for 30 minutes demonstrated a greater linearity than those of samples treated for 5 minutes. Therefore, to find an unknown absorbed dose in a fingernail sample using a calibration curve, we recommend adopting the mentioned chemical treatment procedure to reduce the uncertainty.

Determination of Research Octane Number using NIR Spectral Data and Ridge Regression

  • 정호일;이혜선;전지혁
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권1호
    • /
    • pp.37-42
    • /
    • 2001
  • Ridge regression is compared with multiple linear regression (MLR) for determination of Research Octane Number (RON) when the baseline and signal-to-noise ratio are varied. MLR analysis of near-infrared (NIR) spectroscopic data usually encounters a collinearity problem, which adversely affects long-term prediction performance. The collinearity problem can be eliminated or greatly improved by using ridge regression, which is a biased estimation method. To evaluate the robustness of each calibration, the calibration models developed by both calibration methods were used to predict RONs of gasoline spectra in which the baseline and signal-to-noise ratio were varied. The prediction results of a ridge calibration model showed more stable prediction performance as compared to that of MLR, especially when the spectral baselines were varied. . In conclusion, ridge regression is shown to be a viable method for calibration of RON with the NIR data when only a few wavelengths are available such as hand-carry device using a few diodes.