• Title/Summary/Keyword: chemical measurement

Search Result 2,133, Processing Time 0.029 seconds

Monitoring Failure Behaviour of Pultruded CFRP Composites by Electrical Resistance Measurement

  • Mao, Yaqin;Yu, Yunhua;Wu, Dezhen;Yang, Xiaoping
    • Carbon letters
    • /
    • v.5 no.1
    • /
    • pp.18-22
    • /
    • 2004
  • The failure behaviours of unidirectional pultruded carbon fiber reinforced polymer (CFRP) composites were monitored by the electrical resistance measurement during tensile loading, three-point-bending, interlaminar shear loading. The tensile failure behaviour of carbon fiber tows was also investigated by the electrical resistance measurement. Infrared thermography non-destructive evaluation was performed in real time during tensile test of CFRP composites to validate the change of microdamage in the materials. Experiment results demonstrated that the CFRP composites and carbon fiber tows were damaged by different damage mechinsms during tensile loading, for the CFRP composites, mainly being in the forms of matrix damage and the debonding between matrix and fibers, while for the carbon fiber tows, mainly being in the forms of fiber fracture. The correlation between the infrared thermographs and the change in the electrical resistance could be regarded as an evidence of the damage mechanisms of the CFRP composites. During three-point-bending loading, the main damage forms were the simultaneity fracture of matrix and fibers firstly, then matrix cracking and the debonding between matrix and fiber were carried out. This results can be shown in Fig. 9(a) and (b). During interlaminar shear loading, the change in the electrical resistance was related to the damage degree of interlaminar structure. Electrical resistance measurement was more sensitive to the damage behaviour of the CFRP composites than the stress/time curve.

  • PDF

Development of Continuous Real-time COD Measurement Sensor with Double Beam and Multiple Wavelength Analysis (더블 빔 구조, 다파장 분석을 적용한 연속식 실시간 COD 측정 센서 개발)

  • Lee, Joon-Seok;Shin, Daejung;Hyoung, Gi-Woo;Ryu, In-Jae
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.272-277
    • /
    • 2014
  • At present, the index of chemical oxygen demand (COD) is widely used as an indicator of organic water pollution with biochemical oxygen demand (BOD). But, traditional COD measurement method are not only with various chemical reagents exhausted, but also long time consumed, the operation procedure and the modification are much professional. This paper reported a novel COD measurement system using double-beam and multiple wavelength analysis UV-VIS spectrometries. It consists of pulsed xenon lamp, two-way optical fiber, optical switch, spectrometer and main processor. Proposed COD measurement system obtains any spectral information of water sample (KHP standard sample and two river water and wastewater) and reference sample (distilled water) in the range of 200~520 nm, corresponding to the COD concentration from 0 to 300 mg/L through calculating the UV absorbance. The system show improved precision and can work continuously fast at time interval about 25 seconds.

On-Line Measurement System for the Determination of Chemical Oxygen Demand (화학적 산소 요구량 측정을 위한 On-Line 측정 시스템에 관한 연구)

  • 정형근;차기철
    • Journal of Environmental Science International
    • /
    • v.7 no.2
    • /
    • pp.203-208
    • /
    • 1998
  • A simple on-line measurement system consisting of a conventional peristaltic pump, a HPLC-type heater, and a flow-through spectrophotometer is introduced for the determination of chemical oxygen demand(CODI. The system was configured such that the reaction mixture in the highly concentrated surffuric acrid medium flowing through the PTFE reaction tubing was heated at 150℃ and the absorbance of dichromate was continuously moutored at 445 m. The same addation principle as in the standard procedure was employed akcept the use of CoSO4 as a new effective catalyst. To test the system, potassium hydrogen phthalate was selected as a COD standard material. With suitably optimized reaction condition, the applicable concentration range depends on the concentration of potassium dichromate in the oxidizing reagent. With 2.0×10-3 M and 5.0×10-4M dichromate, the linear dynamic range was observed up to 400 ppm and 100 ppm, respectively. The standards in the Unear ranges were shown to be completely oxidized, which was confirmed with sodium oxalate or Mohr's salt. In all cases, the typical reproduclbility for betweenruns was 2% or less. The proposed measurement system provides the valuable in- formation for the further development of automated analysis system based on the present standard procedure.

  • PDF

Development of On-Line Measurement System for Adsorption Process (흡착공정용 온라인 측정시스템의 개발)

  • Kim, Byoung Chul;Lee, Ki Sung;Yamamoto, Takuji;Kim, Young Han
    • Korean Chemical Engineering Research
    • /
    • v.47 no.3
    • /
    • pp.321-326
    • /
    • 2009
  • A simple measuring device is proposed, and its performance is examined in an adsorption process separating a gas mixture. The sensor is made of a quartz crystal resonator and solid adsorbent to detect the target component. Micro-particle carbon cryogel(MCC) is utilized as the adsorbent, and the gas mixture of air and i-butane are separated in a column containing bamboo activated carbon. Two devices are placed at the inlet and outlet of the column. The measurements are compared with those of GC outcome to prove the measurements are effective. The experimentally proved system is simple and capable to be implemented in an in-line system with on-line measurement.

Angular-based Measurement for Quantitative assay of Albumin in three-dimensional Paper-based analytical Device (회전각도를 이용한 알부민 농도 측정용 3차원 종이 칩)

  • Kim, Dong-Ho;Jeong, Seong-Geun;Lee, Chang-Soo
    • Korean Chemical Engineering Research
    • /
    • v.58 no.2
    • /
    • pp.286-292
    • /
    • 2020
  • This study presents an angular-based measurement on three-dimensional paper-based analytical devices (3D-PADs) for quantitative detection of albumin without using an image analyzer. We demonstrate a simple quantitative and straightforward approach based on the angle of the discolored area as detection criteria. 3D-PADs are rapidly fabricated by the wax-printing and laminating process. The 3D-PADs are treated with citrate buffer and tetrabromophenol blue to react with albumin in a sample solution. Dropping sample solution into sample pad in the 3D-PAD, fluid flows toward the assay zone laterally and vertically by capillary action. We find that the change of angle of the discolored area correctly reflects the concentration of albumin and is reliable determinant for the measurement of the albumin concentration. It is the first demonstration of angular-based detection as a simple, inexpensive, and equipment-free approach for point-of-care diagnosis.

Measurement of Crystal Formation Using a Quartz Crystal Sensor

  • Joung, Ok-Jin;Kim, Young-Han
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1659-1661
    • /
    • 2004
  • Measurement of supersaturation is important in crystallization processes, because it is one of key factors to control crystal size distribution and shape determining product quality. A monitoring system of the supersaturation using a quartz crystal sensor is applied to the supersaturation measurement. From the variation of resonant frequency, the beginning of the formation of salt crystal on the sensor surface is detected while the sensor is directly cooled down. The degree of supersaturation is computed from the solubility difference at the temperatures of the salt solution and the sensor. The performance of the propsed system of the supersaturation measurement is examined by applying the system to the crystallization of three different salt solutions. The experimental outcome compared with eye observation result and photographic analysis indicates that the proposed system is effective and useful to determine the supersaturation in the crystallization process. In addition, the microscopic monitoring of the initial stage crystallization is available with the sensor system.

  • PDF

A Fiber-Optic Sensor for Ultrasonic Measurement (광섬유 센서를 이용한 초음파 검출)

  • Sim, S.H.;Lee, K.S.;Lee, D.I.;Lee, S.H.;Kim, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1715-1717
    • /
    • 2001
  • The partial-discharge(PD) is accompanied by physical and chemical phenomena, such as heat, light, noise gas, chemical transformation, electric current, and electromagnetic radiation. The PD can be detected by measuring one of these changes. Although some techniques are employed in this purpose, several obstacles interfere with an on-line measurement. Now, a fiber-optic sensor for detecting ultrasonics is suggested for the on line measurement system with high accuracy. This paper describes the basic principles fiber-optic sensor for ultrasonic measurement.

  • PDF

Quantitative Analysis of Trace pp'-DDE in Corn Oil by Isotope Dilution Mass Spectrometry : Uncertainty Evaluations

  • 김병주;김달호;최종오;소헌영
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.8
    • /
    • pp.910-916
    • /
    • 1999
  • A current interest in chemistry concerns traceability of analytical measurements to the International System of Units (SI) and the proper estimation of their uncertainties in accordance with the internationally agreed guide provided by the International Organization for Standardization (ISO). Isotope dilution mass spectrometry (IDMS) is regarded as a primary method, which make the measurement results traceable to SI units without significant empirical correction factors. Our laboratory, as the national standards institute of Korea, participated in an intercomparison of environmental analysis, pp'-DDE in corn oil, which was organized by the CCQM under supervision of the CIPM to test feasibility of IDMS as a primary method for the trace analysis of organic compounds. In this report, we provide basic equations used for the calculation of the concentration of the analyte in a sample and a precise description of the processes for the evaluation of the uncertainties of the measurement results. Also, we report the experimental conditions adopted to improve the accuracy of the IDMS measurement. The principles contained in ??Guide to the Expression of Uncertainty in Measurement'' provided by ISO are followed for the uncertainty evaluation.