Evaluation on Four Volatile Organic Compounds (VOCs) Contents in the Groundwater and Their Human Risk Level

  • Song, Dahee;Park, Sunhwa;Jeon, Sang-Ho;Hwang, Jong Yeon;Kim, Moonsu;Jo, Hun-Je;Kim, Deok-Hyun;Lee, Gyeong-Mi;Kim, Ki-In;Kim, Hye-Jin;Kim, Tae-Seung;Chung, Hyen Mi;Kim, Hyun-Koo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.50 no.4
    • /
    • pp.235-250
    • /
    • 2017
  • In this study, we monitored 4 volatile organic compounds (VOCs) such as chloroform, dichloromethane, 1,2-dichloroethane, and tetrachloromethane in groundwater samples to determine the detection frequency and their concentrations and evaluated the health risk level considering ingestion, inhalation, and skin contact. 75 groundwater wells were selected. 24 wells were from monitoring background groundwater quality level and 51 wells were from monitoring groundwater quality level in industrial or contamination source area. In the results, the detection frequency for chloroform, dichloromethane, 1,2-dichloroethane, and tetrachloromethane was 42.3%, 8.1%, 6.0%, and 3.4%, respectively. The average concentrations of VOCs were high in the order of chloroform ($1.7{\mu}g\;L^{-1}$), dichloromethane ($0.08{\mu}g\;L^{-1}$), tetrachloromethane ($0.05{\mu}g\;L^{-1}$), and 1,2-dichloroethane ($0.05{\mu}g\;L^{-1}$). Chloroform had the highest detection frequency and average detection concentration. In the contaminated groundwater, the detection frequency of VOCs was high in the order of chloroform, dichloromethane, 1,2-dchloroethane, and tetrachloromethane. The average concentrations for chloroform, dichloromethane, 1,2-dichloroethane, and tetrachloromethane were $2.23{\mu}g\;L^{-1}$, $0.08{\mu}g\;L^{-1}$, $0.07{\mu}g\;L^{-1}$, and $0.06{\mu}g\;L^{-1}$, respectively. All the 4 compounds were detected at industrial complex and storage tank area. The maximum concentration of chloroform, dichloromethane, and 1,2-dichloroethane was detected at industrial complex area. Especially, the maximum concentration of chloroform and dichloromethane was detected at a chemical factory area. In the uncontaminated groundwater, the detection frequency of VOCs was high in the order of chloroform, dichloromethane, and 1,2-dchloroethane and tetrachloromethane was not detected. The average concentrations for chloroform, dichloromethane, and 1,2-dichloroethane were $0.57{\mu}g\;L^{-1}$, $0.07{\mu}g\;L^{-1}$, and $0.03{\mu}g\;L^{-1}$, respectively. Although chloroform in the uncontaminated groundwater was detected the most, the concentration of chloroform was not exceeding water quality standards. By land use, the maximum detection frequency of 1,2-dichloroethane was found near a traffic area. For human risk assessment, the cancer risk for the 4 VOCs was $10^{-6}{\sim}10^{-9}$, while the non-cancer risk (HQ value) for the 4 VOCs is $10^{-2}{\sim}10^{-3}$.

A Study on Optimal Operation for Flare systems (플레어 시스템의 최적 운영방안에 대한 연구)

  • Song, Bang-Un;Bok, Hyeong-Jun;Woo, In-Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.1-7
    • /
    • 2019
  • Most oil refineries and chemical plants have flare systems designed to mitigate pressure rises in process facilities in case of emergencies that require the release of large amounts of gas due to sudden process shutdowns such as power outages. However, the rise of the flame of the flare system causes civil complaints from residents around the factory due to visible pollution, and economic loss occurs in the company, which requires constant management. In this study, two items were diagnosed and analyzed in order to derive the optimal operation method of flare system. First, to detect the cause of the rise in flame height, the acoustic leak detector was used to check gas leaks in safety valves and pressure control valves. Second, to identify the cause of flame instability, the pulsation phenomenon was diagnosed through the CFD simulation and modeling experiments of the sealing drum. By confirming the leak at 4.3% of the safety valve and 10% of the pressure control valve, the cause of abnormal sparking was derived. The information presented in this study can be easily applied to any company that has a flare system, and is expected to prevent complaints and product loss.

Robust Design for Showerhead Thermal Deformation

  • Gong, Dae-Wi;Kim, Ho-Jun;Lee, Seung-Mu;Won, Je-Hyeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.150.1-150.1
    • /
    • 2014
  • Showerhead is used as a main part in the semiconductor equipment. The face plate flatness should remain constant and the cleaning performance must be gained to keep the uniformity level of etching or deposition in chemical vapor deposition process. High operating temperature or long period of thermal loading could lead the showerhead to be deformed thermally. In some case, the thermal deformation appears very sensitive to showerhead performance. This paper describes the methods for robust design using computational fluid dynamics. To reveal the influence of the post distribution on flow pattern in the showerhead cavity, numerical simulation was performed for several post distributions. The flow structure appears similar to an impinging flow near a centered baffle in showerhead cavity. We took the structure as an index to estimate diffusion path. A robust design to reduce the thermal deformation of showerhead can be achieved using post number increase without ill effect on flow. To prevent the showerhead deformation by heat loading, its face plate thickness was determined additionally using numerical simulation. The face plate has thousands of impinging holes. The design key is to keep pressure drop distribution on the showerhead face plate with the holes. This study reads the methodology to apply to a showerhead hole design. A Hagen-Poiseuille equation gives the pressure drop in a fluid flowing through such hole. The assumptions of the equation are the fluid is viscous-incompressible and the flow is laminar fully developed in a through hole. An equation can be expressed with radius R and length L related to the volume flow rate Q from the Hagen-Poiseuille equation, $Q={\pi}R4{\Delta}p/8{\mu}L$, where ${\mu}$ is the viscosity and ${\Delta}p$ is the pressure drop. In present case, each hole has steps at both the inlet and the outlet, and the fluid appears compressible. So we simplify the equation as $Q=C(R,L){\Delta}p$. A series of performance curves for a through hole with geometric parameters were obtained using two-dimensional numerical simulation. We obtained a relation between the hole diameter and hole length from the test cases to determine hole diameter at fixed hole length. A numerical simulation has been performed as a tool for enhancing showerhead robust design from flow structure. Geometric parameters for the design were post distribution and face plate thickness. The reinforced showerhead has been installed and its effective deposition profile is being shown in factory.

  • PDF

Technical Evaluation of MBR Process for the Wastewater Treatment of Beverage Fabrication Processes (음료수 제조 공정 폐수의 MBR 처리 기술 평가)

  • Jung, Cheol Joong;Park, Jong Min;Kim, Youn Kook
    • Membrane Journal
    • /
    • v.24 no.1
    • /
    • pp.63-68
    • /
    • 2014
  • Manufacturing facility for non-alcoholic drink, the parts of the food industry, disposes wastewater which includes high organic concentration and low nitrogen, phosphorus concentration. For this kind of wastewater, the treatment plant consists mainly of aerobic reactor and chemical coagulation process. And sand-filter or activated carbon process is normally installed further. However, aerobic reactor must have long HRT to treat high concentration of organic contaminant included in this wastewater, so the large site area is required. And settling tank which is normally applied for wastewater treatment facility has some problems such as water quality degradation caused by the sludge spill. To solve these problems, we applied MBR system for the wastewater. And the MBR pilot plant was installed nearby the wastewater treatment facility of W food factory and operated during long term to evaluate treatment efficiency. This plant was operated about 3 months and than the result was 97% of organic removal rate on conditions of flow rate $20m^3/day$, HRT 29 hr, recycle 4Q. However, contaminant removal ratio of bio-reactor decreased and TMP of membrane increased rapidly on more conditions.

Bacterial Community Structure of Food Wastewater Treatment System Combined with Rotating Biological Contactor and Tapered Aeration Reactor (회전접촉장치와 점감포기 반응조를 이용한 식품폐수 처리시설의 세균군집 구조)

  • Jeong, Soon-Jae;Nam, Ji-Hyun;Bae, Woo-Keun;Lee, Dong-Hun
    • Korean Journal of Microbiology
    • /
    • v.46 no.2
    • /
    • pp.169-176
    • /
    • 2010
  • A pilot-scale wastewater treatment plant combined with rotating biological contactor and tapered aeration reactors was operated with the wastewater discharged from a food factory for 5 months. The bacterial communities of this plant were investigated by terminal restriction fragment length polymorphism (T-RFLP) and phylogenetic analysis of 16S rRNA genes. In spite of high concentration of nitrogen and phosphorus as well as organic carbon, removal efficiency of chemical oxygen demand, total nitrogen, and total phosphorus was 98%, 93%, and 95%, respectively. Bacterial community at the initial operation stage was clearly distinguished from that of the stable operation stage. The most predominant phylum in the sample of stable stage was Bacteroidetes. Major population of operation period was Haliscomenobacter, Sphaerotilus, and candidate division TM7, which were classified as filamentous bacteria. However, sludge bulking caused by these bacteria was not observed. The population that has a close relationship with Haliscomenobacter increased during the stable operation stage, emerging as the most predominant group. These results suggest that the filamentous bacteria participated in nutrient removal when using rotating biological contactor and tapered aeration reactor.

VOC/HAPs Emission Characteristics & Adsorption Evaluation for Paint Products in Busan Area (부산지역 페인트제조시설의 VOC/HAPs 배출특성 및 흡착능 평가)

  • Song, Bok-Joo;Lee, Seung-Min;Cho, Gab-Je;Cho, Jeong-Gu;You, Pyung-Jong;Kim, Gi-Gon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.5
    • /
    • pp.316-325
    • /
    • 2012
  • In this study, we suggested adequate control technology by analyzing emission process and main chemical of VOC/HAPs generated from four paint factories in Busan area. And we estimated whether Kapok fiber, which is a natural material, can be commercially used for an absorbent by testing adsorption ability. As a result of this sturdy, above 60% of VOC/HAPs was volatilized and dispersed inside the working place without conducting control system of facilities during manufacturing paints. Concentration profile of VOC/HAPs, which is volatile naturally outside the factories, is surveyed above 70% at Toluene, Ethylbenzene, and Xylene. And a result of evaluation of odor attribution level about the component whose Odor Threshold is known, it is estimated that major cause material of A, B, C factories is Toluene and that of D factory is m/p-Xylene. And that result presented design arguments such as facilities specifications, activated carbon filling volume, and replace cycle of activated carbon as control technology. Also, that result presented emission process improvement such as adsorption of central-controlled ventilation device, installation of inlet flenge, and potable cleaning process. The rate of pollutant adsorption of Kapok fiber, which is natural material, is indicated about 91.9%, 66.7%. That result validated the possibility as replacement of activated carbon.

Assessment of Groundwater Contamination Using Geographic Information System (지리정보시스템을 이용한 지하수 오염 평가)

  • 전효택;안홍일
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.5 no.3
    • /
    • pp.129-140
    • /
    • 1998
  • In this study two sites were selected to investigate groundwater contamination and spatial relationship between pollution level and its source. One is the Asan area, agricultural district where pollution sources are scattered. The other is the Gurogu area of Seoul city, industrial district where industrial complex and residential areas are located. Groundwater samples collected from these districts were analysis for chemical constituents. The attribute value files of the chemical constituents of groundwater and the spatial layers have been constructed and the pollution properties have been investigated to find out spatial relationships between the groundwater constituents and pollution sources using CIS. Relatively high contents of Si and HCO$_3$ in groundwater from the Asan area reflect the effect of water-rock interaction, whereas high contents of Cl, NO$_3$, SO$_4$and Ca in groundwater from the Gurogu area are due to the pollution of various sources. Pollution over the critical level of Korean Dinking Water Standard has been investigated from 15 sampling sites out of 40 in the Asan area, and 33 sampling sites out of 51 in the Gurogu area. There is pollution of NO$_3$, Cl, Fe, Mn, SO$_4$and Zn in groundwater from the Gurogu area, and that of NO$_3$, SO$_4$and Zn in groundwater from the Asan area. Principal pollution in both areas is NO$_3$contamination. Deep groundwater from the Asan area is not contaminated with NO$_3$except for one site and most of shallow groundwater near the potential point sources such as factory and stock farm is contaminated seriously. Groundwater from the Gurogu area has been already polluted seriously considering the fact of contamination of deep groundwater. This study reports a spatial relationship between the pollution level and pollution source using GIS.

  • PDF

Changes of Chemical Composition and Microflora in Bottled Vacuum Packed Kimchi during Storage at Different Temperature (진공처리 병포장 김치의 저장조건별 성분과 미생물 변화)

  • Shin, Dong-Hwa;Kim, Moon-Sook;Han, Ji-Sook;Lim, Dae-Kwan;Park, Jun-Myeong
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.127-136
    • /
    • 1996
  • Mak-kimchi (shredded kimchi) which was prepared in a commercial factory was packed in bottle (200 g) under vacuum (560 mmHg) or atmosphere, and chemical characteristics and microbiological parameters were monitored during storage at 5, 15 and $25^{\circ}C$, respectively. Optimum ripening time of the kimchi at different temperature were 2 days at $25^{\circ}C$, 5 days at $15^{\circ}C$ and more than 60 days at $5^{\circ}C$. By vacuum treatment pH and acidity changes in kimchi were considerably retarded. The vacuum of each bottle released within 1 or 2 days at 25 or $15^{\circ}C$, respectively but the pack at $5^{\circ}C$ maintained more than 380 mmHg vacuum for 36 days and then the vacuum slowly released. The colour of kimchi (lightness, redness, yellowness) in bottle increased sharply at $25^{\circ}C$ and $15^{\circ}C$ but sustained a stable level with vacuum treatment at $5^{\circ}C$. The range of total viable count of kimchi in bottle was $10^7{\sim}10^{10}/ml$. The number decreased by storage temperature drop to $5^{\circ}C$ and even more vacuum treatment than atmosphere treatment at $5^{\circ}C$. Lactobacillus brevis, L. plantarum, L. acidophilus, Aerococcus viridans and Streptococcus faecium subsp. casseliflavus were identified in bottled kimchi and L. brevis and L. plantarum contributed to the main function during kimchi fermentation. Those main lactic acid bacteria decreased in numbers at $5^{\circ}C$ than 25 or $15^{\circ}C$ and even more declined in case of vacuum treatment.

  • PDF

Diagnostic assessment on vegetation damage due to hydrofluoric gas leak accident and restoration planning to mitigate the damage in a forest ecosystem around Hube Globe in Gumi (구미 휴브글로브 주변 삼림생태계에서 불화수소가스 유출 사고에 기인한 식생피해 진단 및 그 피해를 완화시키기 위한 복원 계획)

  • Kim, Gyung Soon;An, Ji Hong;Lim, Chi Hong;Lim, Yun Kyung;Jung, Song Hie;Lee, Chang Seok
    • Journal of Wetlands Research
    • /
    • v.17 no.1
    • /
    • pp.45-52
    • /
    • 2015
  • We obtained the following results from investigation on vegetation damage from 5 to 6 August, 2013, about one year after an accident that hydrofluoric acid leaked from a chemical maker, Hube Globe in Gumi. Pinus densiflora and Pinus strobus showed very severe damage. Ginko biloba, Quercus acutissima, Pinus rigida, Salix glandulosa, Hibiscus syriacus, and Lagerstroemia indica showed severe damage. Quercus variabilis, Lespedeza cyrtobotrya, and Miscanthus sinensis showed moderate damage. Quercus aliena, Smilax china, Arundidinella hirta, Ailanthus altissima, Robinia pseudoacacia, and Paulowinia coreana showed slight damage. We did not find any plants without leaf damage around there. This result means that fluoride damage still persists in this area as was known that fluoride remains for a long time in air, soil and water and exerts negative effects at all levels of an ecosystem. In addition, fluoride content contained in plant leaf depended on the distance from a fertilizer producing factory and vegetation damage tended to proportionate to the concentration in the Yeocheon industrial complex. In these respects, a measure for removal or detoxification of the remaining fluoride is urgently required around the hydrofluoric acid leak spot. Fertilizing of dolomite containing Ca and Mg, which can trap fluoride, was prepared as one of the restoration plans. In addition, phosphate fertilizing was added in order to enhance soil ameliorating effects. Furthermore, we recommend the introduction of tolerant plants as the second measure to mitigate fluoride damage. As the tolerant plants to make a new forest by replacing trees died due to hydrofluoric acid gas damage, we recommended Q. aliena and S. china, A. hirta, etc. were recommended as plant species to add mantle vegetation to the forest margin to ensure stable interior environment of the forest.

A study on the physico-chemical characteristics of municipal solid wastes generated in the sunchon city (순천시의 생활폐기물 발생량 예측 및 재활용시설의 용량산정에 관한 연구)

  • Hu, Kwan;Moon, Ok-Ran;Wang, Seung-Ho
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.9 no.4
    • /
    • pp.125-134
    • /
    • 2001
  • The purpose of this study is to provide basic information for a future countermeasure municipal and to establish several wastes policy after investigating solid wastes from Sunchon City. In addition, this research can be supported to manage of recycling plant and to reuse plant of each wastes. Results are as bellows after checking up and analysis type of waste in Sunchon city Unit solid waste generation rate from single family is $0.50kg/person{\cdot}day$, and total solid wastes are 41.9ton/day. Unit solid waste generation rate from apartments is $0.45kg/person{\cdot}day$, and solid wastes generation is 55.5ton/day. Unit solid waste generation rate from agricultural is $0.22kg/person{\cdot}day$ and total solid wastes are 13.5ton/day. That show total amount of municipal solid wastes from residential are 110.9ton/day. Unit solid waste generation rate from traditional markets is $1.85kg/person{\cdot}day$, and solid waste total volume is 5,400kg/day. Unit solid waste generation rate from small store is $2.03kg/person{\cdot}day$, and solid waste total are 25,101kg/day. Therefore, this show that total wastes are 30.50kg from downtown and commercial area. Solid waste quantity from Industrial area (Factory region) is 8.5ton and in case of school and hospitals are 7.2kg/day and 3.0kg/day. Solid waste amount from Institutional is 6.6kg/day. Food wastes were eliminated from municipal solid wastes as standard 63.4ton/day, and combustible wastes were 126.9ton/day. If it schedule about 5 years (by 2006) as durable year for food wastes treatment plant, it is expected 42.5ton/day for treatment capacity. We can judge that it is effective to be set 2 lines equipment ${\times}25ton/day$ as treatment ability under considering unexpected working condition such as any repair, trouble and an electrical load. If it schedule about 10 years (by 2011) as durable year for food wastes treatment plant, it is expected 150 ton/day for treatment capacity. We can conclude that it is effective to be set 2 lines equipment ${\times}80ton/day$ as treatment ability under considering working condition such as low loaded operating and the repair for incineration.