• Title/Summary/Keyword: charge measurement

Search Result 564, Processing Time 0.027 seconds

The Measurement System of Space Charge Distribution in Polymer Dielectric Materials by the PEA Method (펄스정전응력법(PEA)을 이용한 고분자 유전체 내의 공간전하분포 측정시스템)

  • Hwang, Bo-Seung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.6
    • /
    • pp.1403-1411
    • /
    • 2012
  • In this paper, we have evaluated theoretically the PEA method which is the most popular methods for the non-destructive measurement of space charge distribution in polymer dielectric materials and is recently one of big issues in DC high voltage cables. On the basis of theoretical evaluation, we have developed the space charge measurement system in polymer dielectrics under DC appled voltage and improved the accuracy of space charge distribution by applying the deconvolution process for distorted signals.

Space Charge Measurement as a Diagnostic Tool to Monitor Ageing in Polymeric Materials

  • Chen, George
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.235-239
    • /
    • 2006
  • Charge dynamics in polymeric materials after aged under ac electric field using the pulsed electroacoustic (PEA) technique is reported. The emphasis is placed on charge decay. The charge dynamics of the ac aged additive free low density polyethylene (LDPE) samples under dc bias differ from the sample without ac ageing, indicating changes brought in by ac ageing. It is believed that a slow decay rate of charge in the ac aged sample is related to the formation of deep traps in the material. However, chemical analysis by infrared spectroscope (FTIR) and Raman microscope reveals no significant chemical changes taken place in the bulk of the material after ac ageing. Further experiments on irradiated LDPE have revealed a similar behaviour, i.e. the charge decay is slower in irradiated samples than that of fresh sample. The findings presented clearly indicate that space charge measurement can be used as a diagnostic tool to monitor ageing in polymeric materials.

Effect of Performance of Aerosol Charge Neutralizers on the Measurement of Highly Charged Particles Using a SMPS (에어로졸 중화기의 성능이 고하전 입자의 크기분포 측정에 미치는 영향)

  • Ji, Jun-Ho;Bae, Swi-Nam;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1498-1507
    • /
    • 2003
  • A SMPS(scanning mobility particle sizer) system measures the number size distribution of particles using electrical mobility detection technique. An aerosol charge neutralizer, which is a component of the SMPS, is a bipolar charger using a radioactive source to apply an equilibrium charge distribution to aerosols of unknown charge distribution. However, the performance of aerosol charge neutralizers is not well known, especially for highly charged particles. In this study, the effect of the particle charging characteristics of two aerosol charge neutralizers on the measurement using a SMPS system was experimentally investigated for highly charged polydisperse particles. One has radioactive source of $^{85}$ Kr (beta source, 2 mCi) and the other has $^{210}$ Po (alpha source, 0.5 mCi). The air flow rate passing through each aerosol charge neutralizer was changed from 0.3 to 3.0 L/min. The results show that the non-equilibrium character in particle charge distribution appears as the air flow rate increases although the particle number concentration is relatively low in the range of 1.5∼2x10$^{6}$ particles/㎤. The low neutralizing efficiency of the $^{85}$ Kr aerosol charge neutralizer for highly charged particles can cause to bring an artifact in the measurement using a SMPS system. However, the performance of the $^{210}$ Po aerosol charge neutralizer is insensitive to the air flow rate.

A Study on the Space Charge Polarity Measurement Teasurement Technology of Cross-Linked Polyethylene for Power Cable (전력케이블용 가교폴리에틸렌의 공간전하 극성측정기술에 관한 연구)

  • 국상훈;서장수;김병인;박중순
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.6 no.6
    • /
    • pp.23-31
    • /
    • 1992
  • Charged particle in the polymers is supposed to affect the electrical conduction and to lead them th dielectrical breakdown finally. So we measured the space charge distribution made by application of high electric field and evaluated the polarity of the charged particle affected on electrical conduction and space charge formed in the insulating materials by using temperature gradient thermally stimulated current measurement method(TG-TSC measurement). As a result, in the cross-linked polyethylene, A-peak was caused from dipole polarization, C-peak was caused from ionic space charge polarization and D-peak was injected trap hole. Also we found it crossible the evaluated the polarity of injected trap carrier and electron(or hole) of carrier trap in the cross-lined polyethylene. We found that ${\gamma}$-ray irradiated low density polyethylene had a relation to the electronic trap and we also could get the value of electric field distribution in the samples of which evaluation was available.

  • PDF

Numerical Analysis of Pressure Propagation to the Main Charge by Warhead Penetration into Concrete Targets (탄두의 콘크리트 표적관통 시 주장약에 전파되는 압력의 수치해석)

  • Yun, Kyung Jae;Yoo, Yo-Han
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.339-345
    • /
    • 2016
  • This paper is concerned with the numerical simulation result of pressure propagation to the main charge by warhead penetration into concrete targets. In this study, we developed on-line pressure measurement method in the main charge during warhead penetration. Using the on-line pressure measurement method, we successfully recorded the pressure-time history in the main charge during the field penetration test. Then we compared result of numerical simulations with test data and found that the simulation results are in good agreement with the test results. Finally, through the numerical calculations it is concluded that the installation of liner is effective in reducing pressure level produced in the main charge.

Calculation of mobile charge density in ferroelectric films using TVS(Triangular Voltage (TVS법을 이용한 강유전체 박막내에서의 mobile charge밀도 산출)

  • 김용성;정순원;김채규;김진규;이남열;김광호;유병곤;이원재;유인규
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.433-436
    • /
    • 1999
  • In this paper we applied TVS(Triangular Voltage Sweep) method to calculate the mobile ionic charge densities in some ferroelectric thin films. During the measurement, the temperature of specimens were maintained at 20$0^{\circ}C$. By this method, the amount of mobile ionic charge Q$_{m}$ and mobile ionic charge density N$_{m}$ of a MFIS structure were calculated 3.5 [pC] and about 4.3$\times$10$^{11}$ [ions/cm$^2$], respectively. In order to successful TVS measurement, the gate leakage current density of films must be low 10$^{-9}$ (A/cm$^2$) order.der.

  • PDF

experiment and its upgrade with the large silicon charge detector

  • Lee, Jik;Nam, Ji-Woo;Park, Il-Hung;Yang, Jong-Man;Lee, Hye-Young;Na, Go-Woon;Jeon, Jin-A;Suh, Jung-Eun;Lim, Sun-In;Lee, Moo-Hyun;Seo, Eun-Suk
    • Bulletin of the Korean Space Science Society
    • /
    • 2011.04a
    • /
    • pp.20.2-20.2
    • /
    • 2011
  • The NASA Antarctica balloon experiment CREAM has successfully collected the data of energetic cosmic rays during flights in past years. We will present the recent analysis results of the CREAM experiment. We will also report on the launch and recovery process of the latest flight. The silicon charge detector of the CREAM has played the key role in the precision measurement of the charge constitution of energetic cosmic rays. We proposed the upgrade of the CREAM experiment with the installment of a new large silicon charge detector on top of the CREAM instrument. The charge measurement of the large silicon detector with no material in front is expected to improve the accuracy of the CREAM charge measurement drastically when combined with the measurement of the existing double layer silicon detector. We will present the fabrication of the large silicon detector and its performance in the radiation source test as well as in the beam test.

  • PDF

Electret Characteristics of polyethylene terephthalate for electret installation (전기설비용 polyethylene terephthalate의 electret 특성연구)

  • 국상훈;서장수
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.3
    • /
    • pp.78-85
    • /
    • 1996
  • This paper experience the mechanism for the electret of polyethyleneterephthalate(PET) by using surface potentail measurement means. We investigated the internal charge production and becoming week by evaporating electrode in sample structure of electret coexist with hetero charge and homo charge, as the study based on two charge theory. We expects that the hetero charge consists of the dipole and ion displacement of internality, the homo charge consists of injected charge of externality.

  • PDF

Measurement of wall charge characteristics for three-electrode AC PDP

  • Yoon, Sang-Jin;Yang, Hee-Chan;Kang, Seong-Ho;Ryu, Jae-Hwa;Kang, Bong-Koo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.605-608
    • /
    • 2002
  • This paper proposes a real-time wall charge measurement circuit for three-electrode AC PDP. It includes a charge-compensation network, current-integrating capacitors, initializing switches, and an op-amp. With this equipment, we measure the wall charge variations for the effects of sustain voltage, sustain pulse width, sustain frequency, and neighboring cells.

  • PDF

"Charge Neutralization for Deposit Control"

  • Buikema, Peter D.
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.29 no.3
    • /
    • pp.87-94
    • /
    • 1997
  • As the paper market becomes more and more competitive, more mills will want to switch to alkaline papermaking to take advantage of the Vowing demand. Many papermakers have tried to do this without success in the past much like the American papermakers did in the late 1970's. The Problem is that runnability Problems occur, drainage slows, Presses pick drying becomes more difficult and sheet quality suffers as a result Sheet holes and breaks occur, and runnability becomes a real operating problem. Converting to alkaline papermaking is not as simple as turning off the alum. We must be aware of the numerous factions that alum served at acid pH and provide alkaline alternatives. It is the purpose of this paper to discuss methods of deposit control via charge neutralization and system control at alkaline pH. This article explains the concept as well as the measurement and control. The resultant benefits are seen in runnability, quality and profitability for the papermaker.

  • PDF