• 제목/요약/키워드: charge detector

검색결과 198건 처리시간 0.026초

CdTe 와 ZnS:AgCl phosphor를 이용한 Hybrid형 X선 검출기의 특성연구 (The characteristic study of hybrid X-ray detector using CdTe and Zns:AgCl phosphor)

  • 석대우;강상식;김진영;박지군;문치웅;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 센서 박막재료 반도체 세라믹
    • /
    • pp.71-74
    • /
    • 2003
  • Photoconductor for direct detection fiat-panel imager present a great materials challenge, since their requirement include high X-ray absorption, ionization and charge collection, low leakage current and large area deposition, CdTe is practical material. We report studies of detector sensitivity, That is an CdTe with $5{\mu}m$ thickness on glass. That is hybrid layer of depositting ZnS:AgCl phosphor with $100{\mu}m$ on CdTe. The leakage current of hybrid is similar to it of a-Se, but photocurrent is larger than a-Se. Both of them have high spatial resolution, but hybrid has higher sensitivity than a-Se at comparable bias voltage.

  • PDF

Monte-Carlo simulation for detecting neutron and gamma-ray simultaneously with CdZnTe half-covered by gadolinium film

  • J. Byun ;J. Seo ;Y. Kim;J. Park;K. Shin ;W. Lee ;K. Lee ;K. Kim;B. Park
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.1031-1035
    • /
    • 2023
  • Neutron is an indirectly ionizing particle without charge, which is normally measured by detecting reaction products. Neutron detection system based on measuring gadolinium-converted gamma-rays is a good way to monitor the neutron because the representative prompt gamma-rays of gadolinium have low energies (79, 89, 182, and 199 keV). Low energy gamma-rays and their high attenuation coefficient on materials allow the simple design of a detector easier to manufacture. Thus, we designed a cadmium zinc telluride detector to investigate feasibility of simultaneous detection of gamma-rays and neutrons by using the Monte-Carlo simulation, which was divided into two parts; first was gamma-detection part and second was gamma- and neutron-simultaneous detection part. Consequently, we confirmed that simultaneous detection of gamma-rays and neutrons could be feasible and valid, although further research is needed for adoption on real detection.

이중 산란형 컴프턴 카메라 구성 검출기 성능 평가 (Performance Evaluation of Component Detectors of Double-scattering Compton Camera)

  • 서희;박진형;김찬형;이주한;이춘식;이재성
    • Journal of Radiation Protection and Research
    • /
    • 제35권2호
    • /
    • pp.69-76
    • /
    • 2010
  • 현재 개발중에 있는 이중 산란형 컴프턴 카메라는 두 대의 산란부 검출기(양면 실리콘 스트립 검출기, DSSD)와 하나의 흡수부 검출기(NaI(Tl) 섬광 검출기)로 구성되며, 소형이면서도 높은 영상해상도를 제공할 수 있는 구조를 가지고 있다. 본 연구에서는 이중 산란형 컴프턴 카메라를 구성하고 있는 감마선 검출기들의 에너지 분해능 및 시간 분해능을 평가하고, 산란부 검출기의 에너지 분해능에 영향을 미치는 인자들을 등가 노이즈 전하(equivalent noise charge)를 통하여 분석하였다. DSSD-1은 평균적으로 59.5 keV 피크($^{241}Am$)에 대하여 $25.2keV{\pm}0.8keV$ FWHM의 에너지 분해능을 보였으며, DSSD-2는 $31.8keV{\pm}4.6keV$ FWHM의 에너지 분해능 지니고 있는 것으로 확인되었다. DSSD의 시간 분해능은 57.25 ns FWHM으로 평가되었고, NaI(Tl) 섬광 검출기의 시간 분해능은 7.98 ns FWHM이었다. 또한 이중산란형 컴프턴 카메라를 이용하여 $^{137}Cs$ 점선원에 대한 컴프턴 영상을 획득한 후 성능을 평가하였다. 이번 실험을 통해서 영상해상도 8.4 mm FWHM (각 분해능 $8.1^{\circ}$ FWHM)을 획득하였고, 영상감도는 $1.5{\times}10^{-7}$(고유 효율=$1.9{\times}10^{-6}$)으로 나타났다.

시리얼 데이터 통신을 위한 기준 클록이 없는 3.2Gb/s 클록 데이터 복원회로 (A 3.2Gb/s Clock and Data Recovery Circuit without Reference Clock for Serial Data Communication)

  • 김강직;정기상;조성익
    • 전자공학회논문지SC
    • /
    • 제46권2호
    • /
    • pp.72-77
    • /
    • 2009
  • 본 논문은 별도 기준 클록 없이 고속 시리얼 데이터 통신을 위한 3.2Gb/s 클록 데이터 복원(CDR) 회로를 설명한다. CDR회로는 전체적으로 5부분으로 구성되며, 위상검출기(PD)와 주파수 검출기(FD), 다중 위상 전압 제어 발진기(VCO), 전하펌프(CP), 외부 루프필터(LF)로 구성되어 있다. CDR회로는 half-rate bang-bang 타입의 위상 검출기와 입력 pull-in 범위를 늘릴 수 있도록 half-rate 주파수 검출기를 적용하였다. VCO는 4단의 차동 지연단(delay cell)으로 구성되어 있으며 튜닝 범위와 선형성 향상을 위해 rail-to-rail 전류 바이어스단을 적용하였다 각 지연단은 풀 스윙과 듀티의 부정합을 보상할 수 있는 출력 버퍼를 갖고 있다. 구현한 CDR회로는 별도의 기준 클록 없이 넓은 pull-in 범위를 확보할 수 있으며 기준 클록 생성을 위한 부가적인 Phase-Locked Loop를 필요치 않기 때문에 칩의 면적과 전력소비를 효과적으로 줄일 수 있다. 본 CDR 회로는 0.18um 1P6M CMOS 공정을 이용하여 제작하였고 루프 필터를 제외한 전체 칩 면적은 $1{\times}1mm^2$이다. 3.2Gb/s 입력 데이터 율에서 모의실험을 통한 복원된 클록의 pk-pk 지터는 26ps이며 1.8V 전원전압에서 전체 전력소모는 63mW로 나타났다. 동일한 입력 데이터 율에서 테스트를 통한 pk-pk 지터 결과는 55ps였으며 신뢰할 수 있는 입력 데이터율 범위는 약 2.4Gb/s에서 3.4Gb/s로 나타났다.

$BrO_2/a-Se$ 구조의 방사선 변환센서에서 a-Se에 첨가된 조성비 변화에 따른 I-V 특성 비교 (Comparison of the I-V Characteristic as Various Composition ratio of Iodine in a-Se of $BrO_2/a-Se$ based Radiation Conversion Sensor)

  • 최장용;박지군;공현기;안상호;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.440-443
    • /
    • 2002
  • Present1y the X-Ray diagnosis system is a real condition that is changing by digital ways in it's existent analog ways. This digital radiation detector is divided by the direct method and the indirect method. The indirect method of applied voltage has special qualities that the resolution is low than direct method by diffusion effect that happens. The conversion process ( radiation${\rightarrow}$visible ray${\rightarrow}$electrical signal of two times, has shortcomings that the energy conversion efficiency of electrical signal is low. The direct method has shortcomings that need strong electric fie1d to detect electrical signal efficiently. This research achieved to develop digital detector of the Hybrid method that have form that mixes two ways to supplement shortcoming of direct. indirect method. A studied electrical characteristic by Iodine's Mixture ratio change is added to selenium in the detector which has a multi-layer structure (Oxybromide + a-Se). There are 8 kinds of Manufactured compositions to amorphous selenium Iodine each 30ppm, 100ppm, 200 ppm, 300ppm, 400ppm, 500ppm, 600ppm, 700ppm by a doped photoconductor through a vacuum thermal evaporation method. The phosphor layer is consisted of Oxybromide ($BrO_2$) which uses optical adhesives multi-layer structure. The manufactured compositions calculates and compares Net Charge and signal to noise ratio measuring Photocurrent about Darkcurrent and X-ray. When doped Iodine Mixture ratio is 500ppm to the multi-layer structure (Oxybromide + a-Se), applied voltage of $3V/{\mu}m$, leakage current of compositions $2.61nA/cm^2$ and net charge value by 764pC/$cm^2$/mR then the best result appeared.

  • PDF

세기검출기를 이용한 광 영상 암호화 (Optical Image Encryption Based on Characteristics of Square Law Detector)

  • 이응대;박세준;이하운;김수중
    • 대한전자공학회논문지SD
    • /
    • 제39권3호
    • /
    • pp.34-40
    • /
    • 2002
  • 본 논문에서 위상변조와 푸리에 변환을 이용하여 이진 영상을 위한 새로운 암호화 방법을 제안한다. 복호를 위해서 제곱칙 특성을 이용한다. 키 영상은 랜덤 패턴의 위상변조와 그의 푸리에 변환으로 구해지며 입력영상은 위상 변조된 랜덤 패턴과 위상 변조된 입력의 곱을 푸리에 변환함으로서 암호화된다 암호화된 영상과 키 영상은 위상 정보만을 가지므로 일반 세기 검출기로는 복사나 위조가 불가능하며 복호는 키 영상에 의해서만 가능하다. 원 영상을 재생하기 위해, 키 영상과 암호화된 영상의 위상 마스크는 푸리에 변환 렌즈와 함께 각각 마흐-젠더 간섭계 경로에 따로 두며 출력 영상은 CCD 카메라에 세기 형태로 나타난다. 제안한 방법은 위상 변조기로 LCD를 사용하고 CCD 카메라의 특성을 이용하여 재생하므로 실시간 처리가 가능하다. 제안된 방법이 컴퓨터 모의 실험과 광학적 실험 결과 암호화 구조로서 우수한 성능을 갖음을 보여준다.

레이저유도 플라즈마분광법을 이용한 방사성폐기물 유리의 현장분석 시스템 개발 (Development of in-situ Analysis System for Radwaste Glass Using Laser Induced Breakdown Spectroscopy)

  • 김천우;박종길;신상운;하종현;송명재;이계호
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 학술논문집
    • /
    • pp.137-146
    • /
    • 2004
  • 방사성폐기물 유리화 공전 중 용융로 내에서 유리시료를 직접분석 하기 위한 레이저유도 플라즈마분광법(LIBS: Laser Induced Breakdown Spectroscopy)을 개발 중이다. LIBS 시스템을 구성하기 위하여 분광기, 검출기, 레이저 등의 장비들을 구축하였다. 분광기는 CCD(charge coupled device)가 보정되어 내장되어있는 ESA 3000을 레이저는 Q-switched Nd-YAG인 Brilliant로 구매하여 분석시스템을 구축하였다. 구축된 분석시스템 분야별 성능들을 확인하였으며 최적화 연구를 수행하였다. 첫 번째 단계로 Fe가 함유된 시료에 레이저를 주사하였을 때 발광스펙트럼을 측정하였으며 검출기의 지연시간을 변화시켰을 때의 발광스펙트럼의 특성과 이를 이용한 여기온도를 Einstein-Boltzmann 식을 이용하여 계산하였다. 시료에 532nm Nd-YAG 레이저를 주사하고 검출기의 지연시간을 500, 1000, 1500, 2000ns로 변화시켰을 때의 분광선의 intensity 및 여기온도 변화를 분석하였다. 그 결과 검출시간이 1500㎱ 일 때 여기온도는 7820k로 가장 최적의 상태를 확인하였다. 향후 이 시스템은 유리화 실증시설에 적용되어 용융로 외부로의 유리시료 이송 없이 현장에서 유리성분들의 정량분석을 수행할 예정이다.

  • PDF

$Gd_2O_2S(Eu^{2+} )/a$-Se$ 구조의 X선 검출 센서에서 $a-Se_{1-x}As_x$의 검출효율 비교 (Comparison of the Detection Efficiency $a-Se_{1-x}As_x$ in X-ray Detection Sensor of $Gd_2O_2S(Eu^{2+})/a$-Se Structure)

  • 강상식;박지군;이동길;문치웅;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.436-439
    • /
    • 2002
  • Recently, It has performed that the basic research of the photoconductive material and the development and application of the digital radiograph detector which is divided into the direct and indirect method. The objective of this study investigate the effect of the electric characteristic about changing the composition of Arsenic in hybrid detector system for compensating a defect of conventional. We fabricated samples using the amorphous Selenium and Arsenic alloy with various concentrations of the Arsenic{seven step 0.1%, 0.3%, 0.5%, 1%, 1.5%, 3%, 5%). And using EFIRON optical adhesives the formed multi-layer$(Gd_{2}O_{2}S(Eu^{2+}))$ composed phosphor layer. X-ray and light sensitivity was measured to study x-ray response characteritics. As results, highest value was measured as output net charge and SNR were $315.7pC/cm^2/mR$ and 99.4 at 0.3%As doping ratio.

  • PDF

우주전파관측용 음향광학 전파분광기의 제작 (Manufacture of an Acousto-Optical Spectrometer for Radio Astronomical Observations)

  • 임인성;최재현;오승엽
    • 한국전자파학회논문지
    • /
    • 제8권1호
    • /
    • pp.1-12
    • /
    • 1997
  • 우주전파신호 분석을 위한 음향광학 전파분광기를 제작하였다 이 시스템은 우주로부터 수신된 미약한 전파신 호를 분석하는 신호처리 장치로 레이저 공진기 광학계. 광편향소자와 CCD로 구성된다. 이 시스템은 전파 시호를 분석하는 기존의 필터뱅크, 자기상관 분광기와는 달리 레이저와 광학계를 사용하여 빔을 유도하고 전파신호를 광편향소자에 의해 초음파로 변환하여 레이저빔을 회절시키는 새로운 방식의 전파 분광기이다. 광원으로는 He-Ne 레이저를 사용하였으며, 1 GHz에서 2 GHz까지의 대역폭을 갖는 광대역 GaP 광편향소자를 사용였다 . 또한 광신호 검출을 위해 2,048 채널의 CCD를 제작하였다 본 연구에서는 음향광학효과에 대한 이론적 배을 설명하고 레이저 공진기를 이용한 광학계의 설계, 광학마운트의 제작, CCD Driver, 인터페이스 제작과 이를 이용한 전파 신호의 측정에 대해 논의하였다. 전파선호의 측정결과 0차광이 1차광을 간섭시켜 2,048채널 중 I,000채널의 대역폭을 갖는 분팡가 성능을 갖게 되었다.

  • PDF

하수의 화학적 응집조건 및 응집제별 응집효율 분석 (Chemical Coagulation Conditions and Efficiency of Sewage with Al(III) and Fe(III) Coagulants)

  • 박준규;전동걸;박노백;전항배
    • 상하수도학회지
    • /
    • 제24권4호
    • /
    • pp.463-474
    • /
    • 2010
  • In this study, chemical coagulation conditions for treating combined sewer overflow(CSO) occurred during rainy season were evaluated by jar tests with aluminum sulfate[$Al_2(SO_4)_3{\cdot}17H_2O$] and ferric chloride[$FeCl_3{\cdot}6H_2O$]. The raw domestic sewage sampled from the primary sedimentation tank at a local sewage treatment plant was filtered through $150{\mu}m$ sieve before using. Point of zero charge(PZC) for various dose of aluminum sulfate occurred at pH 5.8-6.5, while for ferric chloride occurred at pH 5.3-6.0 in term of streaming current(SC) values. Charge neutralization ability of aluminum sulfate was bigger than that of ferric chloride. Optimum pH and dose of aluminum sulfate and ferric chloride were 6.2, 0.438mM and 5.8, 0.925mM, respectively. Removal efficiencies of TCOD, turbidity, SS and TP were 75, 97, 95, 96% with aluminum sulfate and 74, 96, 98, 99% with ferric chloride at their optimum coagulation conditions. More efficient removal of SS, TP and small particles was possible with ferric chloride at optimum coagulation conditions. Both SC values and COD removal started to increase where soluble phosphorus was completely removed.