• 제목/요약/키워드: characteristics of currents

검색결과 1,000건 처리시간 0.027초

플래시 EEPROM 응용을 위한 산화막 특성 (The Oxide Characteristics in Flash EEPROM Applications)

  • 강창수;김동진;강기성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.855-858
    • /
    • 2001
  • The stress induced leakage currents of thin silicon oxides is investigated in the VLSI implementation of a self learning neural network integrated circuits using a linearity synapse transistor. The channel current for the thickness dependence of stress current, transient current, and stress induced leakage currents has been measured in oxides with thicknesses between 41 ${\AA}$, 86${\AA}$, which have the channel width ${\times}$ length 10 ${\times}$1${\mu}$m, 10 ${\times}$0.3${\mu}$m respectively. The stress induced leakage currents will affect data retention in synapse transistors and the stress current, transient current is used to estimate to fundamental limitations on oxide thicknesses. The synapse transistor made by thin silicon oxides has represented the neural states and the manipulation which gaves unipolar weights. The weight value of synapse transistor was caused by the bias conditions. Excitatory state and inhitory state according to weighted values affected the channel current. The stress induced leakage currents affected excitatory state and inhitory state.

  • PDF

Bi-2223테이프의 사고전류 특성 (Fault Current Characteristics of a Bi-2223 Tape)

  • 류경우;차귀수
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.65-67
    • /
    • 2001
  • Temperature and resistance of a Bi-2223 tape for fault currents up to 10 $I_{c}$ were measured in two types of samples taking into account real applications. The results indicate that the Bi-2223 tape is safe from burn-out for fault currents with a few cycles up to 10 I$_{c}$. For fault currents of over an order of magnitude higher than the nominal current, the temperature of the Bi-2223 tape depends strongly on fault durations.s.

  • PDF

유전체로 채워진 유한한 슬롯을 가지는 평행평판 도파관 누설파 안테나 구조에 대한 특성 모드 해석 (Characteristics mode analysis for the finite slotted parallel-plate waveguide as a leaky wave antenna structure)

  • 윤이호;조영기
    • 전자공학회논문지D
    • /
    • 제34D권10호
    • /
    • pp.32-38
    • /
    • 1997
  • A characteristic mode analysis of parallel-plate waveguide with finite number of slot as a leaky wav eantenna structure is considered for calculating the characteristics currents, the characteristic patterns, radiatin patterns, and the complex propagation constants. For the cases of 1, 11 and 29 slots, numericl resutls for the equivalent magnetic currents, the radiatin patterns, and thecomplex propagation constants are computed and compared with those obtained by use of the conventional method of moments. Good correspondence between them is observed.

  • PDF

사고 패턴 분류에 기초한 배전계통의 적응 재폐로방식 (An Adaptive Reclosing Scheme Based on the Classification of Fault Patterns in Power distribution System)

  • 오정환;김재철;윤상윤
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권3호
    • /
    • pp.112-119
    • /
    • 2001
  • This paper proposes an adaptive reclosing scheme which is based on the classification of fault patterns. In case that the first reclosing is unsuccessful in distribution system employing with two-shot reclosing scheme, the proposed method can determine whether the second reclosing will be attempted of not. If the first reclosing is unsuccessful two fault currents can be measured before the second reclosing is attempted, where these two fault currents are utilized for an adaptive reclosing scheme. Total harmonic distortion and RMS are used for extracting the characteristics of two fault currents. And the pattern of two fault currents is respectively classified using a mountain clustering method a minimum-distance classifier. Mountain clustering method searches the cluster centers using the acquired past data. And minimum-distance classifier is used for classifying the measured two currents into one of the searched centers respectively. If two currents have the different pattern it is interpreted as temporary fault. But in case of the same pattern, the occurred fault is interpreted as permanent. The proposed method was tested for the fault data which had been measured in KEPCO's distribution system, and the test results can demonstrate the effectiveness of the adaptive reclosing scheme.

  • PDF

고조파 전류에 의한 배선용 차단기 동작 특성 (Operating Characteristics of Molded Case Circuit Breakers by Harmonic Currents)

  • 전정채;유재근;이상익
    • 조명전기설비학회논문지
    • /
    • 제20권2호
    • /
    • pp.68-74
    • /
    • 2006
  • 고조파 전류에 의한 배선용 차단기 오동작 및 원인불명 동작이 보고되고 있으나 고조파 전류에 의한 배선용 차단기 동작을 설명할 수 있는 자료가 없는 실정이다. 본 논문에서는 네 가지 형태의 배선용 차단기(열동식, 열동 전자식, 완전 전자식 및 전자식)에 대해 고조파 전류의 영향을 시험하였다. 실험 결과 정격전류 이하의 고조파가 포함된 시험 전류에서는 어떤 종류의 배선용 차단기에서도 오동작은 발생하지 않았다. 그리고 다양한 고조파 부하 조건에서 열동식과 열동 전자식의 경우 제조사의 동작 시간에 별다른 영향을 보이지 않았다. 그러나 완전 전자식 차단기는 과부하 조건에서 고조파 전류가 증가할 수 록 동작 시간이 점차 둔화되었고 이는 케이블 과열을 야기할 수 있을 것이다. 따라서 고조파 전류가 심한 곳에서는 완전 전자식 배선용 차단기의 사용을 피해야 할 것이다.

비대칭 고장전류 저감 기능을 갖는 초전도 한류기의 최적 저항 결정 방안 (A Decision Method for the Optimal Insertion Resistance of a Superconducting Fault Current Limiter with Reduction of an Asymmetric Fault Current)

  • 김창환;김규호;이상봉
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.57-63
    • /
    • 2015
  • Fault currents characteristics contain decaying DC offset. First cycle peak value of fault currents is higher than steady-state fault current value. These characteristics can affect the operation of protective device. To reduce the asymmetric fault current, the method using a series connection of two hybrid-type Superconducting Fault Current Limiter(SFCL) components, an auxiliary SFCL and a main SFCL, has been proposed. The auxiliary SFCL limits the first half cycle fault current, while main SFCL limits the steady state fault currents. This paper proposed a decision method of the optimal insertion resistance of auxiliary and main SFCL components. To verify the effectiveness of proposed scheme, the various simulations are performed by using Electromagnetic Transient Program(EMTP).

Theory and Experiment for Electromagnetic Shaft Current in Rotating Machinery

  • Kim, Chaesil;Park, Jong-Kweon
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제3권1호
    • /
    • pp.20-25
    • /
    • 2002
  • Electrical damages to critical parts in rotating machinery have caused many machinery failures and hours of costly downtime. The problem of shaft currents generated in non-electrical machines has puzzled both users and manufacturers of these machines. The main solution for preventing electromagnetic type damage is to demagnetize all of the machinery parts, however this is costly and time consuming. Therefore a thorough investigation into the causes and physical characteristics of electromagnetic shaft currents is needed. In this paper, the self excitation theory was developed far a simple model, an axial flux Faraday disk machine surrounded by a long solenoid. Experimental tests were conducted to investigate the physical characteristics on an electromagnetic self excitation rig. The theory showed that the directions of both the shaft rotation and the coil turns should be identical if self excitation is to occur. From the tests, the electromagnetic type shaft current had both AC and DC components occurred at all vibration frequencies. This could point to a way to detect small instabilities or natural frequency locations by monitoring shaft currents.

Offset 구조를 갖는 n-채널 다결정 실리콘 박막 트랜지스터의 I-V 분석 (The Analysis of I-V characteristics on n-channel offset gated poly-Si TFT`s)

  • 변문기;이제혁;김동진;조동희;김영호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.26-29
    • /
    • 1999
  • The I-V characteristics of the n-channel offset gated poly-Si TETs have been systematically investigated in order to analyse the effects of offset region. The on currents are reduced due to the series resistance by the offset length and there is no kink phenomenon in offset devices. The off currents of the offset gated TFTs are remarkably reduced to 10$^{-12}$ A independent of gate and drain voltage because the electric field is weakened by the increase of the depletion region width near the drain region. It is shown that the offset regions behave as a series resistance and reduce lateral and vertical electric field.

  • PDF

전류분포가 3본-도체의 임계전류 특성에 미치는 영향 (Influence of Current Distributions on Critical Current Characteristics in a 3-conductor)

  • 조영호;류경우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.792-794
    • /
    • 2003
  • AC loss is an important issue in the design of high-$T_c$ superconducting power cables which consist of a number of Bi-2223 tapes wound on a former. In the cables, the tapes have different critical currents intrinsically. And they are electrically connected to each other and current leads. In this work we have prepared a conductor composed of three Bi-2223 tapes with different critical currents. The critical current characteristics in the conductor have experimentally investigated. The results show that for uniform current distributions the conductor's critical current is proportional to the critical current of the Bi-2223 tape to which a voltage lead is attached. However it depends on the current non-uniformity parameter in the conductor rather than the tape's critical currents for nonuniform current distributions.

  • PDF

회전기계의 전자기 축전류에 대한 이론 및 실험 (Theory and Experiment for Electromagnetic Shaft Current in Rotation Machinery)

  • 김재실
    • 한국정밀공학회지
    • /
    • 제16권12호
    • /
    • pp.40-45
    • /
    • 1999
  • Electrical damages to critical parts in rotation machinery have caused may machinery failures and hours of costly downtime. The problem of shaft currents generated in non-electrical machines have puzzled both users and manufacturers of these machines. The main solution for preventing electro- magnetic type damage is to demagnetize all of the machinery parts, however this is costly and time consuming. Therefore a thorough investigation into the causes and physical characteristics of electro- magnetic shaft currents is needed. In this paper, the self excitation theory was developed for a simple model, and axial flux Faraday disk machine surrounded by a long solenoid. Experimental tests were conducted to investigate the physical characteristics on an electromagnetic self excitation rig. The theory showed that the directions of both the shaft rotation and the coil turns should e identical if self excitation is to occur. From the tests, the electromagnetic type shaft current had both AC and DC components occurred at all vibration frequencies. This could point to the way to detect small instabilities or natural frequency locations by monitoring shaft currents.

  • PDF