• 제목/요약/키워드: characteristics of currents

검색결과 998건 처리시간 0.035초

포화현상을 고려한 비율차동계전기의 동특성 해석 (Danamic Characteristics of Percentage Differential Relays Considering Saturation Effect)

  • 김남호;김일남;이준창
    • 산업기술연구
    • /
    • 제14권
    • /
    • pp.89-100
    • /
    • 1994
  • The effects of transient inrush currents on the dynamic characteristics of percentage differential relays are studied when the power transformers are reenergized. An algorithm of estimation the nonlinear magnetic property of power transformer and current trnasformer core are developed. Using this method, we can analyze the effect of inrush currents on the trip region of the percentage differential relays corresponding to the variation of the phase angle and the residual magnetism at the instant of switch closing. Test results are used to verify the availibility of the proposed algorithm. Finally a case study is performed to the 110 MVA main transformer in hydraulic power station.

  • PDF

고온 다결정 실리콘 박막트랜지스터의 전기적 특성과 누설전류 특성 (Electrical Characteristics and Leakage Current Mechanism of High Temperature Poly-Si Thin Film Transistors)

  • 이현중;이경택;박세근;박우상;김형준
    • 한국전기전자재료학회논문지
    • /
    • 제11권10호
    • /
    • pp.918-923
    • /
    • 1998
  • Poly-silicon thin film transistors were fabricated on quartz substrates by high temperature processes. Electrical characteristics were measured and compared for 3 transistor structures of Standard Inverted Gate(SIG), Lightly Doped Drain(LDD), and Dual Gate(DG). Leakage currents of DG and LDD TFT's were smaller that od SIG transistor, while ON-current of LDD transistor is much smaller than that of SIG and DG transistors. Temperature dependence of the leakage currents showed that SIG and DG TFT's had thermal generation current at small drian bias and Frenkel-Poole emission current at hight gate and drain biases, respectively. In case of LDD transistor, thermal generation was the dominant mechanism of leakage current at all bias conditions. It was found that the leakage current was closely related to the reduction of the electric field in the drain depletion region.

  • PDF

동축 고온 초전도 케이블의 전류분포 및 mini-model 케이블의 전기절연 (The Characteristics of Current Distribution of a Coaxial HTS Cable and Insulation of Mini-model Cable)

  • 김영석;곽동순;백승명;김해종;김상현
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.47-50
    • /
    • 2003
  • In order to verify the extended theory, we have fabricated a two layers cable with the same twisting layer pitch. It was observed that almost all the operational current less than the critical current flowed on the outer layer because of its lower inductance. In case of operational current more than critical currents of layers, the flux flow resistances affect strongly current waveform and thereby the currents of layers were determined by the flux flow resistances. And we investigated withstand voltage, impulse voltage and breakdown characteristics of mini-model cable. In these test, the withstand voltage and impulse voltage test was satisfied and the breakdown voltage was 110kV.

  • PDF

절연층을 고려한 Bi-2223/Ag 선재의 교류 과전류 특성 (AC over-current characteristics of Bi-2223/Ag tape considering insulating layers)

  • 두호익;임성우;박충렬;최병환;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.249-250
    • /
    • 2007
  • Applying the AC over-currents over the critical current to Bi-2223/Ag tape having 56 A Ie, resistance increase with the duration of current application was measured and analyzed. In addition, the influence of the tape's electrical insulation on the over-current characteristics was investigated and compared with each other. From the results, we will establish the safe operating condition against the AC over-currents and the protection of the tape for the practical power application such as cable and transformer.

  • PDF

MONOS 구조의 트랩특성 조사를 위한 열자극전류 측정 (Measurements of the Thermally Stimulated Currents for Investigation of the Trap Characteristics in MONOS Structures)

  • 이상배;김주연;김선주;이성배;서광열
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1995년도 추계학술대회 논문집
    • /
    • pp.58-62
    • /
    • 1995
  • Thermally stimulated currents have been measured to investigate the trap characteristics of the MONOS structures with the tunneling oxide layer of 27${\AA}$ thick nitride layer of 73${\AA}$ thick and blocking oxide layer of 40${\AA}$ thick. By changing the write-in voltage and the write-in temperature, peaks of the I-T characteristic curve due to the nitride bulk traps and the blocking oxide-nitride interface traps ware separated from each other experimentally. The results indicate that the nitride bulk traps are distributed spatially at a single energy level and the blocking oxide-nitride interface traps are distributed energetically at interface.

  • PDF

3-레벨 인버터의 누설전류 제거를 위한 캐리어 기반 MVPWM의 과변조 특성 (Overmodulation Characteristics of Carrier Based MVPWM for Eliminating the Leakage Currents in Three-Level Inverter)

  • 이은철;최남섭;안강순
    • 전력전자학회논문지
    • /
    • 제20권6호
    • /
    • pp.509-516
    • /
    • 2015
  • The overmodulation characteristics of a carrier-based medium vector pulse width modulation (CBMVPWM) are examined in this study. CBMVPWM can completely eliminate leakage currents in a three-phase, three-level inverter using only the switching states with the same common mode voltage even in an overmodulation operation. The analytic equations for the magnitude of the output voltage and the switching frequency are derived for overmodulation operation, and the effect of dead time on the leakage current is demonstrated. This study presents the operating principle of CBMVPWM, basic overmodulation features, and simulations and experiments for operating verification.

통계적방법을 이용한 초고압 송전선의 전자계 특성 및 인체 안전에 관한 연구 (A Study on Characteristics and Safety for Human Body in ELF Electric and Magnetic Fields using Statistical Method)

  • 김두현;김상철
    • 한국안전학회지
    • /
    • 제11권3호
    • /
    • pp.75-80
    • /
    • 1996
  • This paper presents a study on characteristics and safety for human body in ELF electric and magnetic fields using statistical method. The magnetic fields from a power line can be computed given a knowledge of the currents, voltage and geometry of the line. In this paper, a statistical method for predicting the magnetic fields given the inherent indetermination of the currents is presented. But the electric field is calculated given a knowledge of the voltage and geometry of the line. The effect of unexpected fluctuations in current is modeled by the Monte Carlo simulation. The suggested method is applied to the 345kV and 765kV transmission line system, the result shows that the maximum electric and magnetic field intensity is 6.8627kV/m and 284mG in 345kV system, 2. 5590kV/m and 35mG in 765kV system, respectively.

  • PDF

Characteistics of Charge Traps and Poling Behavior of Poly (Vinylidene Fluoride)

  • 서정원;류균상;이호성
    • Bulletin of the Korean Chemical Society
    • /
    • 제6권4호
    • /
    • pp.218-221
    • /
    • 1985
  • Transient charging and discharging currents as well as space charge limited currents have been measured in biaxially stretched poly(vinylidene fluoride) film under various poling fields and temperatures. At low temperatures and short poling times, the I-V characteristics showed shallow trap behavior. When the current values extrapolated to the infinite time, the I-V characteristics indicate that the distribution of the trap energy levels is uniform or very broad. The abnormal suppression of current at higher poling voltages and the high discharge rate observed also in the same voltage range are attributed to the morphological changes due to dipole reorientation.

와전류를 이용한 제동장치의 실험적 동특성 연구 (An Experimental Study on Dynamic Characteristics of an Eddy Current Brake System)

  • 이미선;곽동기;배재성;황재혁
    • 항공우주시스템공학회지
    • /
    • 제3권2호
    • /
    • pp.39-43
    • /
    • 2009
  • Eddy currents are generated when a moving conductor is exposed to a stationary magnetic field, or vice-versa. These currents create their own magnetic field, causing a repulsive force between the magnetic material and the conductor. Using this concept, a magnetic brake system can be established by the permanent magnets and a conductive material. In this paper, the eddy current effects on a magnetic brake system which consists of 2 pairs of magnets and a conductor are investigated by using a electromagnetic software, and the results of simulations are compared with experiments. It can be concluded how the arrangement of magnets effects on the dynamic characteristics of the eddy current brake system.

  • PDF

Characterization of Acetylcholine-induced Currents in Male Rat Pelvic Ganglion Neurons

  • Park, Joong-Hyun;Park, Kyu-Sang;Cha, Seung-Kyu;Lee, Keon-Il;Kim, Min-Jung;Park, Jong-Yeon;Kong, In-Deok;Lee, Joong-Woo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제8권4호
    • /
    • pp.219-225
    • /
    • 2004
  • The pelvic ganglia provide autonomic innervations to the various urogenital organs, such as the urinary bladder, prostate, and penis. It is well established that both sympathetic and parasympathetic synaptic transmissions in autonomic ganglia are mediated mainly by acetylcholine (ACh). Until now, however, the properties of ACh-induced currents and its receptors in pelvic ganglia have not clearly been elucidated. In the present study, biophysical characteristics and molecular nature of nicotinic acetylcholine receptors (nAChRs) were studied in sympathetic and parasympathetic major pelvic ganglion (MPG) neurons. MPG neurons isolated from male rat were enzymatically dissociated, and ionic currents were recorded by using the whole cell variant patch clamp technique. Total RNA from MPG neuron was prepared, and RT-PCR analysis was performed with specific primers for subunits of nAChRs. ACh dose-dependently elicited fast inward currents in both sympathetic and parasympathetic MPG neurons $(EC_{50};\;41.4\;{\mu}M\;and\;64.0\;{\mu}M,\;respectively)$. ACh-induced currents showed a strong inward rectification with a reversal potential near 0 mV in current-voltage relationship. Pharmacologically, mecamylamine as a selective antagonist for ${\alpha}3{\beta}4$ nAChR potently inhibited the ACh-induced currents in sympathetic and parasympathetic neurons $(IC_{50};\;0.53\;{\mu}M\;and\;0.22\;{\mu}M,\;respectively)$. Conversely, ${\alpha}-bungarotoxin$, ${\alpha}-methyllycaconitine$, and $dihydro-{\beta}-erythroidine$, which are known as potent and sensitive blockers for ${\alpha}7$ or ${\alpha}4{\beta}2$ nAChRs, below micromolar concentrations showed negligible effect. RT-PCR analysis revealed that ${\alpha}3$ and ${\beta}4$ subunits were predominantly expressed in MPG neurons. We suggest that MPG neurons have nAChRs containing ${\alpha}3$ and ${\beta}4$ subunits, and that their activation induces fast inward currents, possibly mediating the excitatory synaptic transmission in pelvic autonomic ganglia.