• 제목/요약/키워드: characteristic X-ray image

검색결과 68건 처리시간 0.027초

Study on Characteristic difference of Semiconductor Radiation Detectors fabricated with a wet coating process

  • Choi, Chi-Won;Cho, Sung-Ho;Yun, Min-Suk;Kang, Sang-Sik;Park, Ji-Koon;Nam, Sang-Hee
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.192-193
    • /
    • 2006
  • The wet coating process could easily be made from large area film with printing paste mixed with semiconductor and binder material at room temperature. Semiconductor film fabricated about 25mm thickness was evaluated by field emissions-canning electron microscopy (FE-SEM). X-ray performance data such as dark current, sensitivity and signal to noise ratio (SNR) were evaluated. The $Hgl_2$ semiconductor was shown in much lower dark current than the others, but the best sensitivity. In this paper, reactivity and combination character of semiconductor and binder material that affect electrical and X-ray detection properties would prove out though experimental results.

  • PDF

Exposure Index를 이용한 이동형 디지털 X선 장치의 흉부촬영 적정노출조건에 관한 연구 (A Study on the Proper Chest Exposure Conditions of Mobile Digital X-ray Unit by Exposure Index)

  • 김재인;이양섭;장동수;정민철;배승호;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제13권3호
    • /
    • pp.139-144
    • /
    • 2011
  • The purpose of this report is recommending a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The experiment was performed with mobile digital X-ray unit and used a acrylic phantom for exposure index measurement. Exposure modality was kVp, mAs, SID. After every exposure, make a data sheet for characteristic curve of detector response. The equipment performed Mobile digital X-ray unit provide the user with values ralated to the incident exposure(air kerma)to the digital detector. They are showed as a logarithmic function shaped. As a result, DEI means a relative measure of exposure to the detector, as compared to the expected exposure for a particular anatomical view. Radiographic technique is the combination of factors used to exposure an anatomical part to produce a high quality radiography and technique charts used most commonly by radiographers to produce consistently exposure level which patient dose can be kept acceptably low.

  • PDF

대퇴부 방사선영상에서 대퇴골 근위부의 형태학적 측정과 골소주의 특성을 이용한 골다공증 예측에 관한 연구 (A Study of Osteoporosis Prediction using Morphological Measuring of Proximal Femoral Part and Trabecular Characteristics Based on Femoral Radiographic Image)

  • 김성민;노승규;노용만
    • 전기학회논문지
    • /
    • 제59권4호
    • /
    • pp.823-830
    • /
    • 2010
  • This study was designed to examine the morphological measurement and characteristics of trabecullae based on femoral radiographic image for prediction of osteoporosis. Study subjects were 34 females (average age of 62.1 years) and 6 males (average age of 60.1 years), they were categorized into normal group and osteoporosis group in accordance with the T-score value. Measurement of the bone density of femoral bone was measured with DEXA(Dual Energy X-ray absorptiometry). ROI(Region of interests) was selected on femoral neck and trochanter. Characteristics of trabecullae was analyzed by using the skeletonization analysis of trabecular image. Morphological measurement was analyzed through femoral radiographic image in order to examine the correlation with osteoporosis. The result demonstrated statistically significant correlation between neck cortical thickness, shaft width, shaft cortical thickness, periphery, mean gray level and trabeculae area with BMD average (T-score) of femoral part. The results show that morphological measurement and characteristics of trabecullae based on femoral radiographic images for osteoporosis prediction could be effective.

X선 스펙트럼 모델을 이용한 DR 화소값과 디텍터 흡수에너지의 관계에 대한 정량적 분석 (Quantitative Analysis of Digital Radiography Pixel Values to absorbed Energy of Detector based on the X-Ray Energy Spectrum Model)

  • 김도일;김성현;호동수;최보영;서태석;이재문;이형구
    • 한국의학물리학회지:의학물리
    • /
    • 제15권4호
    • /
    • pp.202-209
    • /
    • 2004
  • 현재 평판 디텍터를 이용한 디지털 방사선 촬영기술은 방사선 진단 기술 분야에 있어서 매우 중요하고 유용하게 사용되고 있다. 비정질 실리콘 광센서를 사용하는 디지털 방사선 촬영기에는 흡수되는 방사선 에너지를 가시광선으로 변환하는 신틸레이터로 보통 CsI(TI)를 사용한다. 신틸레이터에서 만들어진 가시광선은 이차원 평면으로 구성된 비정실 실리콘 광 다이오드에서 전기적 신호로 전환된다. 좋은 질의 영상을 얻기 위해서는 디지털 방사선 촬영기(Digital Radiography, DR) 디텍터의 방사선에 대한 세부적인 특성 연구가 필수적이다. 이러한 이유로 조사선량과 디지털 방사선 촬영기의 신호의 관계에 대해서 많은 연구가 이루어졌지만 현재까지의 연구에서는 고정된 관전압의 조건에서 두 변수의 관계에 대한 연구가 이루어졌다. 이에 본 연구에서는 X선 스펙트럼 모델인 SPEC-78을 사용하여 조사선량 대신 디텍터에 흡수되는 에너지와 디지털 방사선 촬영기의 신호와의 관계를 규명하였다. SPEC-78의 주요 입력변수인 X-ray 튜브의 고유 필터 값을 구하기 위해 조사선량을 측정하여 계산한 조사선량과 비교하였다. 물질에 흡수되는 X-ray의 에너지를 계산하는 알고리즘을 상정하여 디텍터에 흡수되는 에너지를 계산하고 다양한 조건에서 실제 X선 영상의 화소값을 획득하였다. 두변수의 관계를 이용해 특성곡선을 얻었으며 이 결과를 검증하기 위해서 물과 알루미늄으로 제작된 팬텀을 이용하였다. 다양한 조건에서 팬텀 영상의 화소값을 측정하였고 특성곡선과 비교하였다 이러한 과정으로 진행된 연구의 결과로 디텍터에 흡수되는 에너지와 디지털 방사선 촬영기의 신호는 거의 선형적임을 알 수 있었다. 또한 팬텀을 이용한 실험에서도 산란된 광자의 영향으로 유발된 약간의 오차에도 불구하고 측정되어진 화소값은 특성곡선과 잘 일치하였다 본 연구를 통해 규명되어진 두 변수의 관계는 예상과 거의 일치하였지만 산란선에 대한 부분은 흡수에너지 계산 알고리즘에서 빠져있어 더 연구가 되어야 할 부분이다. 본 연구를 통해 얻어진 자료들은 디지털 방사선 촬영기의 전처리 과정에 있어서 중요한 정보를 제공할 수 있을 것이라 생각된다.

  • PDF

흉부 엑스선 촬영 시 촬영기법에 따른 영상 평가 (Image Evaluation of Projection Method in Chest Radiography)

  • 안병주;이준행
    • 한국방사선학회논문지
    • /
    • 제16권3호
    • /
    • pp.217-223
    • /
    • 2022
  • 본 연구는 엑스선 흉부촬영에서 격자를 이용하여 촬영법과 Air Gap Technique을 이용한 촬영법에서 얻은 영상을 평가하기 위하여 대학병원 영상의학과에서 10년 이상 근무한 방사선사 선생님 5인에게 주관적 평가 ROC와 객관적 평가 SNR를 시행하였다. 분석한 결과는 Cronbach Alpha 값이 0.714로 유의하게 높았다. Air Gap Technique 촬영법에서 팬톰과 상수용체 간격을 20 cm 띄우고 관전압 100 kVp, 관전류와 촬영시간 8 mAs로 설정하고 촬영한 영상을 ROC 평가에서 18점, SNR 평가에서 6.149로 가장 높은 점수를 얻었다. 또한 격자를 이용하여 촬영법에서는 팬톰과 상수용체 간격을 15 cm 띄우고 관전압 110 kVp, 관전류와 촬영시간을 8 mAs에서 촬영 시 ROC 평가점수가 19점과 객관적평가인 신호대잡음비(SNR)가 6,622으로 가장 높은 점수를 받았다. 이에 격자를 이용하여 나타나는 격자의 cut-off 현상으로 인하여 재촬영뿐만 아니라 판독지연, 환자의 피폭선량 증가, 기계적 수명단축 등의 단점을 벗어나는 Air Gap Technique 촬영법을 활용한다면, 중환자실 및 응급환자를 위한 이동형 엑스선 촬영장비를 사용할 경우를 포함하여 흉부 촬영 시에 많은 도움이 되리라 사료된다.

바늘구멍 골스캔에 의한 갑상선암 골전이 병소내 중격의 묘출 (Pinhole Bone Scintigraphic Demonstration of Septation in Metastatic Thyroid Carcinoma in Bone)

  • 김성훈;정수교;신경섭;박용휘
    • 대한핵의학회지
    • /
    • 제27권2호
    • /
    • pp.305-308
    • /
    • 1993
  • Metastatic thyroid carcinoma in bone shows characteristic expansile, trabeculated lysis on radio-gram. The ordinary scintigraphy manifests with a simple photopenic defect. We were able to portray trabeculation within photopenic defects. We present papillary thyroid carcinoma and follicular thyroid carcinoma, one each, pinhole bone scintigraphic findings of which are cold area with septated increased uptake at the iliae bone. These findings correspond very well with their X-ray pictures.

  • PDF

Imaging findings in a case of Gorlin-Goltz syndrome: a survey using advanced modalities

  • Bronoosh, Pegah;Shakibafar, Ali Reza;Houshyar, Maneli;Nafarzade, Shima
    • Imaging Science in Dentistry
    • /
    • 제41권4호
    • /
    • pp.171-175
    • /
    • 2011
  • Gorlin-Goltz syndrome is an infrequent multi-systemic disease which is characterized by multiple keratocysts in the jaws, calcification of falx cerebri, and basal cell carcinomas. We report a case of Gorlin-Goltz syndrome in a 23-year-old man with emphasis on image findings of keratocyctic odontogenic tumors (KCOTs) on panoramic radiograph, computed tomography, magnetic resonance (MR) imaging, and Ultrasonography (US). In this case, pericoronal lesions were mostly orthokeratinized odontogenic cyst (OOC) concerning the MR and US study, which tended to recur less. The aim of this report was to clarify the characteristic imaging features of the syndrome-related keratocysts that can be used to differentiate KCOT from OOC. Also, our findings suggested that the recurrence rate of KCOTs might be predicted based on their association to teeth.

ROC평가 방법을 이용한 CR과 DDR 흉부 영상의 비교 (The Evaluation of CR and DDR chest image using ROC analysis)

  • 박연옥;박연정;정은경;남소라;정지영;김희중
    • 한국방사선학회논문지
    • /
    • 제1권1호
    • /
    • pp.25-30
    • /
    • 2007
  • 본 연구의 목적은 ROC를 이용하여 일반 촬영기기에 따른 영상의 질을 평가해보고자 함이다. 본 연구의 수행을 위하여 CR(Computed Radiography)과 DDR(Direct Digital Radiography)을 사용하였으며 피사체로 흉부 팬텀을 사용하였다. 각 기기에서 영상을 획득한 후 ROC평가를 이용하여 영상의 질 및 기기의 특성을 평가하였다. 조사 조건으로 관전압 120kVp와 관전류량 3.2 mAs를 이용하였고 SID(Source to Image Distance)는 180cm로 설정하였다. 팬텀의 심장, 폐야, 흉추부위에 병소를 표현하였으며 각 장비에서 획득한 영상의 질 및 기기의 특성을 파악하기 위하여 방사선학 전공자 29명을 대상으로 ROC평가를 실시하였다. ROC 평가 결과 DDR의 TPF(true positive fraction)는 0.552, FPF(false positive fraction)는 0.474, CR의 TPF는 0.629, FPF는 0.405로 나타났다. 본 연구 결과 CR의 영상이 DDR의 영상보다 더 나은 영상의 질을 나타내는 것을 확인하였다. 영상의 질의 확연한 차이의 원인은 DDR의 경우 enhance board의 미 삽입으로 인한 영상 후처리의 미수행이라고 사료된다. 추후 DDR의 enhance board의 삽입 후 영상의 후처리가 가미된 DDR영상의 질에 대한 연구가 필요하며 본 연구의 결과로 인하여 영상의 후처리가 임상의 판독에 있어서 매우 중요한 요소임을 확인할 수 있었다.

  • PDF

복합부가여과에서 알루미늄 여과판 사용 시 양자검출효율과 화질평가를 통한 효율성 분석 (A Analysis of Effectiveness of Aluminium Filter in the added Compound Filtration by Detective Quantum Efficiency and Image Quality Evaluation)

  • 김상현;김연민;권경태;마상철;한동균
    • 한국콘텐츠학회논문지
    • /
    • 제15권10호
    • /
    • pp.362-373
    • /
    • 2015
  • 본 연구는 복합부가여과에서 높은 원자번호 물질에서 발생된 특성방사선을 제거하기 위해 사용되는 알루미늄 여과판의 효율성을 분석하고자 양자검출효율, 화질평가를 실시하였다. 구리 0.1, 0.2, 0.3 mm 에 알루미늄 1mm 사용 전, 후를 평가하였다. IEC 규정에 의해 선질, 양자검출효율을 실험하고 화질평가는 PSNR, MAE, MSE, CNR, SNR 정성적 평가로는 국가암검진 흉부 평가표의 해상, 대조도 평가 7문항을 이용하였다. MTF 10, 50%에서 4.6, 2.54 cycle/mm 모두 동일했고 NPS, DQE, PSNR MAE, MSE, CNR, SNR, 정성적 평가는 모두 알루미늄 미사용 시 같거나 약간 우수했다. PSNR은 30 dB이상으로 모두 의미있는 수치였고 정성적 평가에서 T-test 검정은 p>0.05였다. 알루미늄 여과판은 광자검출효율과 화질 평가에서 사용 전, 후 큰 차이가 없으므로 특성 방사선 제거를 통한 피부선량 감소를 위해 사용됨이 효율적이라고 사료된다.

치과병원에서 사용되는 진단영상에 대한 JPEG2000 압축률에 대한 평가 (Evaluation of compression ratios using JPEG 2000 on diagnostic images in dentistry)

  • 정기훈;한원정;유동수;최순철;김은경
    • Imaging Science in Dentistry
    • /
    • 제35권3호
    • /
    • pp.157-165
    • /
    • 2005
  • Purpose : To find out the proper compression ratios without degrading image quality and affecting lesion detectability on diagnostic images used in dentistry compressed with JPEG 2000 algorithm. Materials and Methods : Sixty Digora periapical images, sixty panoramic computed radiographic (CR) images, sixty computed tomographic (CT) images, and sixty magnetic resonance (MR) images were compressed into JPEG 2000 with ratios of 10 levels from 5:1 to 50:1. To evaluate the lesion detectability, the images were graded with 5 levels (1 : definitely absent; 2: probably absent; 3: equivocal; 4: probably present; 5: definitely present), and then receiver operating characteristic analysis was performed using the original image as a gold standard. Also to evaluate subjectively the image quality, the images were graded with 5 levels (1 definitely unacceptable; 2: probably unacceptable; 3: equivocal, 4: probably acceptable; 5· definitely acceptable), and then paired t-test was performed. Results : In Digora, CR panoramic and CT images, compressed images up to ratios of 15 : 1 showed nearly the same lesion detectability as original images, and in MR images, compressed images did up to ratios of 25 : 1. In Digora and CR panoramic Images, compressed images up to ratios of 5 : 1 showed little difference between the original and reconstructed images in subjective assessment of image quality In CT images, compressed images did up to ratios of 10: 1 and in MR images up to ratios of 15 : 1 Conclusion : We considered compression ratios up to 5 : 1 in Digora and CR panoramic images, up to 10 : 1 in CT images, up to 15 : 1 in MR images as clinically applicable compression ratios.

  • PDF