• 제목/요약/키워드: characteristic X-ray image

검색결과 68건 처리시간 0.04초

X-선영상의 심리적 평가를 위한 판정기준축의 결정 (The decision of the reference axis for the subjective estimation of X-Ray Images)

  • 이용구;이선엽;이원석;엄기환
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2007년도 하계종합학술대회 논문집
    • /
    • pp.439-440
    • /
    • 2007
  • We determined the reference axis for the subjective estimation of X-ray images. The used images are the noised image and the noise plus signal image. The used subjective estimation method is the curve of Receiver Operation Characteristic. To determine the evaluation reference axis between the noise image and the image with signal, Fuzzy Logic System is used.

  • PDF

Hgl2의 누설전류 저감을 위한 다층구조 제작 및 특성 평가 (The Multi-layer Fabrication and Characteristic Performance for Dark Current Reduction of Mercury Iodide)

  • 김경진;박지군;강상식;차병열;조성호;김진영;문치웅;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.388-389
    • /
    • 2005
  • In this paper, the electric properties of mercury Iodide multi-layer samples has been investigated. We measured and analyzed their performance parameters such as the X-ray sensitivity and dark-current for a mercury Iodide multi-layer X-ray detector with a dielectric layer. The digital X-ray image detector can be constructed by integrating photoconduction multi-layer that dielectric layer has characteristics of low dark-current, high X-ray sensitivity. However this process has found to have complexity on the performance of the sample. We have investigate dielectric layer that it substitute dielectric layer for HgO(Mercury Oxide). We have employed two approaches for producing the mercury Iodide sample : 1) Physical Vapor Deposition(PVD) and 2) Particle-In-Binder(PIB). In this paper fabricated by PIB Method with thicknesses ranging from approximately 180um to 240um and we could produce high-quality samples for each technique particular application. As results, the dielectric materials such as HgO between the dielectric layer and the top electrode may reduce the dark-current of the samples. Mercury Iodide multi-layer having HgO has characteristics of low dark-current, high X-ray sensitivity and simple processing. So we can acquired a enhanced signal to noise ratio. In this paper offer the method can reduce the dark-current in the X-ray detector.

  • PDF

X-ray 코곁굴 검사에서 위턱굴 진단을 위한 비극-두정방향 촬영법 개발 (Development of Acanthial Parieto Projection for Maxillary Diagnosis in X-ray Paranasal Sinuses)

  • 안병주;김용완;김인수
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.327-333
    • /
    • 2023
  • 본 연구는 X-Ray 단순 코곁굴 검사에서 위턱뼈와 위턱굴의 진단하고자 바로누운자세에서 부비동 비극-두정방향은 검사법 연구하였다. Skull Rando Phantom을 이용하여 자세와 엑스선관 각도를 변경하여 검사 후 영상의학과에서 10년 이상 근무한 방사선사 5명에게 주관적평가(ROC)를 의뢰한 결과 엑스선관을 머리쪽 또는 다리쪽을 향하여 5° 씩 기울려 검사 시 19점으로 높은 평가를 맞았다. 평가한 점수를 SPSS Ver. 3.0을 통해 유의성을 검증하였으며 Cronbach 값이 0.712로 유의하게 나타났다. 또한 위턱굴과 위턱뼈 영상의 관심영역(ROI)을 설정하여 SNR를 산출한 결과 엑스선관 머리쪽 또는 다리쪽 5° 씩 기울려 검사 시 6.449로 가장 높게 나타났다. 본 연구에서 X-Ray 단순검사의 코곁굴 검사에서 비극-두정방향(acanthi oparietal projection: Revesse Waters) 검사 시 엑스선관을 머리쪽 또는 다리쪽을 향하여 5° 씩 기울려 검사할 경우 선예한 영상을 얻을 수 있을 것으로 사료된다.

X-ray 엉치엉덩관절 촬영법을 통한 류마티스 및 퇴행성관절염 진단 (The Diagnosis of Rheumatologic and Degenerative Arthritis by X-ray Sacroiliac Joint Projection)

  • 이준행
    • 한국방사선학회논문지
    • /
    • 제12권3호
    • /
    • pp.397-402
    • /
    • 2018
  • 본 연구는 엉치엉덩관절의 골절, 탈구, 엉치엉덩 퇴행성관절염 진단을 위한 가장 좋은 영상을 얻기 위해 골반 팬톰과 엑스선관을 각도 변화를 주어 엉치엉덩관절의 Joint space 가장 잘 나타내는 영상을 얻어 방사선사에게 주관적 평가를 받아 보았다. 평가 결과 결론으로 엉치엉덩관절염과 퇴행성 관절염 발견을 위한 단순촬영에서는 엎드린상태에서 촬영은 검사반대쪽 엉덩이를 $25^{\circ}{\sim}30^{\circ}$ 들어올리고 엑스선관을 앞엉덩뼈가 시에서 2.5 cm 안쪽을 지나는 시상면에 대해 수직촬영 하고 누운자세에서는 검사쪽 엉덩이를 $25^{\circ}{\sim}30^{\circ}$ 들어 올리고 위앞엉덩뼈가시가 중앙에서 위앞엉덩뼈가시가 중앙에 대해 엑스선관 각도를 발쪽으로 $5^{\circ}$ 촬영 하며 반드시 양쪽 엉치엉덩관절후전사방향(RAO,LAO) 및 전후사방향(RPO, LPO) 모두 촬영을 하게 되면 관절염 진단을 내리는데 있어 많은 도움이 되리라 본다.

고전압트랜스포머의 진공이 방사선출력 노이즈에 미치는 영향 (Electric power characteristic test of diagnostic X-ray high voltage transformer by input power condition)

  • 김영표;천민우;박용필
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.499-499
    • /
    • 2008
  • High voltage transformer of Diagnostic X-ray system has been contributed to wiping out disease to get a good quality images from patients. High voltage transformer of diagnostic X-ray system has been usefully used for diagnostic purpose but if high voltage transformer performances are deteriorated, low quality image will be archived. In this case, operator has to exposure to get a more good quality images. In this case, unexpected radiation could be exposed to patient and it is very harmful to the patient. And I would like to design and make equipment to checkable high voltage transformer performance after that I wish to test and study what it is most influences in radiation output quality.

  • PDF

몬테카를로 시뮬레이션을 이용한 X선 변환물질의 특성 연구 (Characteristic Study of X-ray convert material by Monte Carlo Simulation)

  • 김진영;박지군;강상식;김소영;정은선;남상희;강신원
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.418-421
    • /
    • 2003
  • Today, much terminologies such as noise spectrum, Sharpness, contrast, MTF had been defined for Image quality revaluation of radiation Image. Since development of Xeroradiography In the 1970s, Digital radiation detector that use amorphous selenium was developed. The aim of this research is to analyze physical phenomenon of digital radiation detector that use amorphous selenium. Result of Monte Carlo simulations on amorphous selenium based on physical properties(creation of electron-hole pairs) by induced x-ray are described. From the simulation, intrinsic point spread function(PSF) was found and used to observe modulation transfer function(MTF). We investigated how PSF and MTF changed with various x-ray energy. This result can be used to design digital x-ray detector based on a-Se.

  • PDF

QUALITY EVALUATION OF TECHNOLOGY OF AGRICULTURAL PRODUCTS

  • Chen, Pictiaw
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.171-190
    • /
    • 1996
  • Quality evaluation of agricultural products has been a subject of interest to many researches for many years. As a results, several nondestructive techniques for quality evaluation of agricultural products have been developed. These methods are based on the detection of various physical properties that correlate well with certain quality factors of the products. This paper presents an overview of various quality evaluation techniques that are based on one of the following properties : density, firmness , vibration characteristic , X-ray and gamma ray transmission, optical reflectance and transmission , electrical properties, aromatic volatile emission, and nuclear magnetic resonance (NMR). The sophistication of nondestructive methods has evolved rapidly with modern technologies. The use of various modern image acquisition techniques, such as solid state TV camera, line-scan camera, X-ray scanning , ultrasonic scanning and NMR imaging, in conjunction with image-processing te hniques has provided new opportunities for researchers to develop many new and improved techniques for nondestructive quality evaluation of agricultural products.

  • PDF

흉부 방사선 영상의 정점영역 매칭을 통한 허파영역 자동검출에 관한 연구 (A Study of Automatic detection for the Lung Boundary using Lung Apex Region Matching of Chest X-Ray Image)

  • 김상진;김용만;이명호
    • 대한의용생체공학회:의공학회지
    • /
    • 제11권2호
    • /
    • pp.217-226
    • /
    • 1990
  • This paper presents a new algorithm that extracted lung region in X-ray and enhanced the region. With a lung region that was extracted by histogram threshold value, it was diffi cult to detect perfect lung boundary. Therefore we presented perfect lung boundary detection method using apex detection and apex region restoration. Also, by applying modified equalization algorithm and presented function to inside of lung region, we want to give help to automatic diagnosis In X-ray chest image. Presented main line trace algorithm gave good result in detection of lung boundary And, as apex detection method using lung row and column gray level average value found more correct place of lung than the rpethod of prior algorithm, we succeeded perfect lung region detection, Also, presented function that had lung region's gray level distribution characteristic was very effective to image enhancement.

  • PDF

디지털 X선 영상센서 적용을 위한 진공증착 CsI 특성평가 (The X-ray Detection Characteristic of vacuum evaporated CsI for Digital X-ray Image Sensor)

  • 신정욱;박지군;최장용;석대우;김재형;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 센서 박막재료 반도체 세라믹
    • /
    • pp.15-18
    • /
    • 2003
  • In recent years, there has been keen interest in phosphor materials responding X-ray. Cesium iodide of the materials is a material with a high $\gamma$-ray stopping power due to its relative high density and atomic number. CsI is noted for its high resistance to thermal and mechanical shock due to the absence of a cleavage plane. To design the structure of CsI detector, we analysed the structure with SEM and XRD and measured UV meter.

  • PDF

몰리브덴(Mo) 특성방사선 획득을 위한 다층박막 거울의 최적 설계 및 공차 분석 (Optimum Design and Tolerance Analysis of Multilayer Mirror for Obtaining Characteristic X-ray of 17.5 keV)

  • 천권수
    • 한국방사선학회논문지
    • /
    • 제3권4호
    • /
    • pp.23-28
    • /
    • 2009
  • 단색 엑스선은 적은 방사선 피폭으로 대조도가 높은 의료영상을 만들 수 있다. 엑스선 튜브와 다층박막 거울을 결합하면 높은 플루언스의 단색 엑스선을 얻을 수 있다. 몰리브덴(Mo) 타깃을 갖는 엑스선 튜브에서 Mo 특성방사선(17.5keV)을 높은 반사율로 획득하기 위한 W/C 다층박막 거울의 최적화를 수행하였다. 반사율이 최대가 되는 조건에서 두께주기와 두께비를 결정하였다. 최적 설계된 다층박막 거울에 대한 두께주기와 브래그 정렬에 대한 공차를 구하였다. 증착(deposition) 공차 0.2nm와 회전정렬 공차 ${\pm}0.01^{\circ}$에서 이론 반사율의 85% 이상에 해당하는 반사율이 얻어질 수 있다. 다층박막 거울을 이용하면 높은 플루언스의 특성방사선을 얻어 낼 수 있기 때문에 의료영상 획득 장치에 많이 사용될 것이다.

  • PDF