• 제목/요약/키워드: channel implant

검색결과 54건 처리시간 0.019초

Multiple transcripts of anoctamin genes expressed in the mouse submandibular salivary gland

  • Han, Ji-Hye;Kim, Hye-Mi;Seo, Deog-Gyu;Lee, Gene;Jeung, Eui-Bae;Yu, Frank H.
    • Journal of Periodontal and Implant Science
    • /
    • 제45권2호
    • /
    • pp.69-75
    • /
    • 2015
  • Purpose: Salivary fluid formation is primarily driven by Ca2+-activated, apical efflux of chloride into the lumen of the salivary acinus. The anoctamin1 protein is an anion channel with properties resembling the endogenous calcium-activated chloride channels. In order to better understand the role of anoctamin proteins in salivary exocrine secretion, the expression of the ten members of the anoctamin gene family in the mouse submandibular gland was studied. Methods: Total RNA extracted from mouse submandibular salivary glands was reverse transcribed using primer pairs to amplify the full-length coding regions of each anoctamin gene and was subcloned into plasmid vectors for DNA sequencing. Alternative splice variants were also screened by polymerase chain reaction using primer pairs that amplified six overlapping regions of the complementary DNA of each anoctamin gene, spanning multiple exons. Results: Multiple anoctamin transcripts were found in the mouse submandibular salivary gland, including full-length transcripts of anoctamin1, anoctamin3, anoctamin4, anoctamin5, anoctamin6, anoctamin9, and anoctamin10. Exon-skipping splicing in the N-terminal exons of the anoctamins1, anoctamin5, and anoctamin6 genes resulted in multiple alternative splice variants. No expression of anoctamin2, anoctamin7, or anoctamin8 was found. Conclusions: The predominant anoctamin transcript expressed in the mouse submandibular gland is anoctamin1ac. The chloride channel protein produced by anoctamin1ac is likely responsible for the $Ca^{2+}$-activated chloride efflux, which is the rate-limiting step in salivary exocrine secretion.

Development of a wireless telemetry system based on MICS standard (MICS 표준에 기반한 무선 텔레메트리 시스템 개발)

  • Lee, Seung-Ha;Park, Il-Yong
    • Journal of Sensor Science and Technology
    • /
    • 제18권1호
    • /
    • pp.63-71
    • /
    • 2009
  • It is said that the desirable bio-signal measurement and stimulation system should be an implantable type if the several problems such as biocompatibility, electrical safety, and so on are overcome. In addition to the biocompatibility issue, a robust RF communication and a stable electrical power source for the implantable bio-signal measurement and stimulation system are very important matters. In this paper, a wireless telemetry system which adopts the FCC's approved MICS (medical implant communication service) protocol and a wireless power transmission has been proposed. The proposed system composed of a base station (BS) and an implantable medical device (IMD) has the advantages that the interference with other RF devices can be reduced by the use of the specially assigned MICS frequency band of 402.MHz to 405 MHz. Also, the proposed system includes various functions of a multi-channel bio-signal acquisition and an electric stimulation. Since the electrical power for the IMD can be provided by the inductive link between PCB patterned coils, the IMD needs no battery so that the IMD can be smaller size and much less dangerous than the active type IMD which includes the internal battery. Finally, the validity as a wireless telemetry system has been demonstrated through the experiments by using the implemented BS and IMD.

Improvement of ESD (Electrostatic Discharge) Protection Performance of NEDSCR (N-Type Extended Drain Silicon Controlled Rectifier) Device using CPS (Counter Pocket Source) Ion Implantation (CPS 이온주입을 통한 NEDSCR 소자의 정전기 보호 성능 개선)

  • Yang, Jun-Won;Seo, Yong-Jin
    • Journal of Satellite, Information and Communications
    • /
    • 제8권1호
    • /
    • pp.45-53
    • /
    • 2013
  • An electrostatic discharge (ESD) protection device, so called, N-type extended drain silicon controlled rectifier (NEDSCR) device, was analyzed for high voltage I/O applications. A conventional NEDSCR device shows typical SCR-like characteristics with extremely low snapback holding voltage. This may cause latch-up problem during normal operation. However, a modified NEDSCR device with proper junction/channel engineering using counter pocket source (CPS) ion implantation demonstrates itself with both the excellent ESD protection performance and the high latch-up immunity. Since the CPS implant technique does not change avalanche breakdown voltage, this methodology does not reduce available operation voltage and is applicable regardless of the operation voltage.

The effect of non-surgical treatment in gingival enlargement (치은비대에서 비외과적 치료의 효과)

  • Kim, Sang-Jun;Lee, Jae-Kwan;Um, Heung-Sik;Chang, Beom-Seok
    • Journal of Periodontal and Implant Science
    • /
    • 제39권1호
    • /
    • pp.103-108
    • /
    • 2009
  • Purpose: It is well recognized that gingival enlargement is induced by unwanted effect associated with three major drugs/drug groups - phenytoin, cyclosporine, and the calcium channel blockers. The present case report describes the effect and limitation of non-surgical treatment in gingival enlargement cases. Materials and methods: Three cases included 2 drug-influenced gingival enlargement patients and a idiopathic gingival fibromatosis patient. For the drug-influenced gingival enlargement patients, the medication was replaced with other medication. And then, all the patients were treated non-surgically. Results: Drug-influenced gingival enlargements had been reduced after non-surgical treatment and the results were well-maintained. In the idiopathic gingival fibromatosis case, non-surgical treatment resulted in only limited reduction of gingival enlargement, and surgical periodontal treatment was unavoidable. Conclusion: These case reports indicated that non-surgical periodontal treatment with change in medication was effective in the treatment of drug-influenced gingival enlargements. Non-surgical approach can be considered as the primary management to reduce the gingival enlargement. If non-surgical treatment encounters a limitation, surgical treatment should be considered.

Effects of CF4 Plasma Treatment on Characteristics of Enhancement Mode AlGaN/GaN High Electron Mobility Transistors

  • Horng, Ray-Hua;Yeh, Chih-Tung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.62-62
    • /
    • 2015
  • In this study, we study the effects of CF4 plasma treatment on the characteristics of enhancement mode (E-mode) AlGaN/GaN high electron mobility transistors (HEMTs). The CF4 plasma is generated by inductively coupled plasma reactive ion etching (ICP-RIE) system. The CF4 gas is decomposed into fluorine ions by ICP-RIE and then fluorine ions will effect the AlGaN/GaN interface to inhibit the electron transport of two dimension electron gas (2DEG) and increase channel resistance. The CF4 plasma method neither like the recessed type which have to utilize Cl2/BCl3 to etch semiconductor layer nor ion implantation needed high power to implant ions into semiconductor. Both of techniques will cause semiconductor damage. In the experiment, the CF4 treatment time are 0, 50, 100, 150, 200 and 250 seconds. It was found that the devices treated 100 seconds showed best electric performance. In order to prove fluorine ions existing and CF4 plasma treatment not etch epitaxial layer, the secondary ion mass spectrometer confirmed fluorine ions truly existing in the sample which treatment time 100 seconds. Moreover, transmission electron microscopy showed that the sample treated time 100 seconds did not have etch phenomena. Atomic layer deposition is used to grow Al2O3 with thickness 10, 20, 30 and 40 nm. In electrical measurement, the device that deposited 20-nm-thickness Al2O3 showed excellent current ability, the forward saturation current of 210 mA/mm, transconductance (gm) of 44.1 mS/mm and threshold voltage of 2.28 V, ION/IOFF reach to 108. As IV concerning the breakdown voltage measurement, all kinds of samples can reach to 1450 V.

  • PDF

THE STUDY OF CORRELATION WITH CYCLOSPORIN A INDUCED GINGIVAL OVERGROWTH AND LOCAL FACTORS (Cyclosporin A 유도 치은증식과 국소적 요인과의 상관관계에 대한 연구)

  • Ko, Eun-Ah;Yoo, Hyung-Keun;Shin, Hyung-Shik
    • Journal of Periodontal and Implant Science
    • /
    • 제25권1호
    • /
    • pp.14-23
    • /
    • 1995
  • Cyclosporin A is a powerful immunosuppressive agent commonly used for patients receiving organ transplants. Like phenytoin and the calcium channel blockers, the drug is associated with gingival overgrowth. The purpose of this study was to compare the correlation with gingival overgrowth score and clinical indices(i.e, : plaque index, papillary bleeding index, probing depth) and correlation with gingival overgrowth score and microorganism distribution in use of phase contrast microscope. After renal tranplant, taking cyclosporin A 40 patients participating in this investigation. Post - transplatation cyclosporin medication period was average $17.53{\pm}15.75$ months. In previous study reported that gingival overgrowth is an adverse side - effects seen in about 25-81% of patient taking cyclosporin A. The results were as follows : 1. Gingival overgrowth prevalence in taking cyclosporin A patients was 77.5%. Prevalence rate of region was anterior region(26 teeth, 55.3%), molar region(14 teeth, 29.8%), premolar region(7 teeth, 14.8%) in turns. Gingival overgrowth score by Angelopoulos & Goaz method was molar region($1.56{\pm}0.81$), anterior region($1.52{\pm}0.75$), premolar region($1.14{\pm}0.90$) in turns. 2. Medication period was not correlation with gingival overgrowth score. 3. Clinical indices and gingival overgrowth score were as follows. 1) Plaque index and gingival overgrowth score was significantly correlated(p

  • PDF

The Effects of Nifedipine on Cellular Activity of Human Gingival Fibroblast (Nifedipine이 건강 치은 조직의 치은 섬유모세포에 미치는 영향)

  • Shin, Hyung-Shik;Han, Hee-Ran;Kim, Myung-Eun
    • Journal of Periodontal and Implant Science
    • /
    • 제26권3호
    • /
    • pp.669-679
    • /
    • 1996
  • Gingival overgrowth is a well known side effect of several drugs, including nifedipine, phenytoin, cyclosporin, dilitiazem, verapamil. A number of studies have been performed to investigate the mechanism by which nifedipine(a calcium channel blocking agent) affects the gingival tissue. The aim of the present work was to investigate the effect of nifedipine on healthy gingival fibroblasts with special emphasis on determining the changes in cellular proliferation and protein and collagen synthesis. Gingival fibroblasts were obtained from the explants of healthy gingiva of extracted 3rd molars or premolar teeth extracted from the patients for orthodontic treatment. To evaluate the effect of nifedipine on cell proliferation, the cells were seeded at a cell density of $1{\times}10^4$cells/well in 24-well culture plates and treated with 100 and 200ng/ml of nifedipine for 10days. After trypsinization, the cells were counted with a haemocytometer on 1st, 3rd, 5th, 7th and 10th days. Then, MTT assay was carried out. For total protein and percent collagen synthesis, $3{\mu}Ci/ml$ $^3H-proline$ was added to each well for the final 4 hours of the incubation period. The results indicate that nifedipine does not influence cell proliferation in healthy gingival fibroblast in vitro and has a specific effect in reducing total protein and percent collagen synthesis. On the above the findings, exogenous nifedipine does not influence on healthy human gingival fibroblast proliferation and protein and collagen synthesis.

  • PDF

Inlay Grafting for the Treatment of the Posterior Comminuted Fracture of Medial Orbital Wall (Inlay법을 이용한 안와 내벽 골절의 교정)

  • Lim, Jong-Hyo;Kim, Tae-Gon;Lee, Jun-Ho;Kim, Yong-Ha
    • Archives of Craniofacial Surgery
    • /
    • 제10권1호
    • /
    • pp.55-60
    • /
    • 2009
  • Purpose: For blowout fracture of the medial orbital wall, the goals of treatment are complete reduction of the herniated soft tissue and anatomic reconstruction of the wall without surgical complications. Surgeons frequently worry about damage to the optic nerve from the dissection, when the part over the posterior ethmoidal foramen was fractured. The authors performed small incision and inlay grafting for reconstruction of medial orbital wall fracture. Methods: Between January 2007 and April 2008, 15 out of 32 patients were included in an analysing the outcome of corrected medial orbital wall fracture. In 15 patients of posterior comminuted fracture of medial orbital wall, insertion of porous polyethylene($Medpor^{(R)}$ channel implant, Porex, USA) to ethmoidal sinus was performed in multiple layer, through the transconjunctival approach (inlay grafting). Results: In all cases, the orbital bone volume was reconstructed in its normal anatomical position. The associated ocular problems disappeared except for mild enophthalmos in 2 patients and there were no surgical complications associated with inlay grafting. Conclusion: The advantage of inlay grafting include anatomical reconstruction of the orbital wall; the avoidance of optic nerve injury; the simplicity of the procedure; and consequently, the absence of surgery-related complications. This technique is presented as one of the preferred treatments for posterior comminuted fracture of medial orbital wall.

Analysis on the Scaling of MOSFET using TCAD (TCAD를 이용한 MOSFET의 Scaling에 대한 특성 분석)

  • 장광균;심성택;정정수;정학기;이종인
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국해양정보통신학회 2000년도 춘계종합학술대회
    • /
    • pp.442-446
    • /
    • 2000
  • The metal-oxide-semiconductor field-effect transistor(MOSFET) has undergone many changes in the last decade in response to the constant demand for increased speed, decreased power, and increased parking density. Therefore, it was interested in scaling theory, and full-band Monte Carlo device simulator has been used to study the effects of device scaling on hot carriers in different MOSFET structures. MOSFET structures investigated in this study include a conventional MOSFET with a single source/drain, implant a lightly-doped drain(LDD) MOSFET, and a MOSFET built on an epitaxial layer(EPI) of a heavily-doped ground plane, and those are analyzed using TCAD(Technology Computer Aided Design) for scaling and simulation. The scaling has used a constant-voltage scaling method, and we have presented MOSFET´s characteristics such as I-V characteristic, impact ionization, electric field and recognized usefulness of TCAD, providing a physical basis for understanding how they relate to scaling.

  • PDF

Objective Evaluation of Beamforming Techniques for Hearing Devices with Two-channel Microphone (2채널 마이크로폰을 이용한 청각 기기에서의 빔포밍에 대한 객관적 검증)

  • Cho, Kyeong-Won;Han, Jong-Hee;Hong, Sung-Hwa;Lee, Sang-Min;Kim, Dong-Wook;Kim, In-Young;Kim, Sun-I.
    • Journal of Biomedical Engineering Research
    • /
    • 제32권3호
    • /
    • pp.198-206
    • /
    • 2011
  • Hearing devices like cochlear implant, vibrant soundbridge, etc. try to offer better sound for people. In hearing devices, several beamformers including conventional directional microphone are applicable to noise reduction. Each beamformer has different directional response and it could change sound intelligibility or quality for listeners. Therefore, we investigated the performance of three beamformers, which are first and second order directional microphone, and broadband beamformer(BBF) with a computer simulation assuming hearing device microphone configuration. We also calculated objective measurements which have been used to evaluate speech enhancement algorithms. In the simulation, a single speech and a single babble noisewere propagated from the front and $135^{\circ}$ azimuth degrees respectively. Microphones were configured in an end-fire array and the spacing was varied in comparison. With 3 cm spacing, BBF had about 3 dB higher enhanced SNR than that of directional microphones. However, enhancement of segmental SNR and frequency weighted segmental SNR were similar between the first order directional microphone and broadband beamformer. In addition when steady state noise was used, broadband beamformer showed the increased performance and had the highest enhanced SNR, and segmental SNR.