• 제목/요약/키워드: change capacity

검색결과 2,167건 처리시간 0.034초

에어컨의 고효율화를 위한 용량가변 방식 비교에 관한 연구 (Benchmark Performance Analysis of Vapor Compression System with Capacity Modulation Compressor)

  • 유윤호;황윤제;김철민;조관식
    • 설비공학논문집
    • /
    • 제14권2호
    • /
    • pp.98-107
    • /
    • 2002
  • The performance of a capacity controlled system, which are tandem, pole change, bypass and inverter driven compressor, has been compared with that of a con- ventional constant speed system. It has been found that capacity modulated system can offer more than 14 percent improvement in SEER over the conventional system. Comparative test results show that two compressor system can attain an improvement in SEER up to 42% over the conventional on/off system, and is feasible without additional investment.

선로용량 계산 통합프로그램 및 민감도분석체계 개발 (-Development on the Integrated System of PES and LCS and Sensitivity Analysis for Line Capacity-)

  • 임찬식;김한신;이창호;김봉선;김동희;홍슨흠
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2004년도 추계학술대회
    • /
    • pp.213-220
    • /
    • 2004
  • A purpose of this research is building a Parameter Evaluation Simulation(PES) program which is present proper parameter value to calculate line capacity. This research performs a detailed simulation and a analysis of it using PES and it is developed on the basis of Line Capacity Simulation model. Chosen simulation sectors are that happened a big change of a line capacity because of joining a high speed train(KTX). Moreover this research performs a sensitivity analysis when basic data are changed.

  • PDF

탄소섬유와 L형강을 이용한 벽-슬래브 접합부의 보강성능 (Structural Performance of Seismic Resistance Capacity of Carbon Sheet-Angle Retrofitting Method in Wall-Slab Joint)

  • 노공기;박태원;박현수;정란
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.65-68
    • /
    • 2004
  • In the seismical capacity evaluation for RC structure wall-slab joint is very important factor. Because lateral load is resistance element and gravity load resistance element are acted mutually in the wall-slab joint. In this paper, to improve the seismic capacity of the wall-slab joint in the existing wall type apartments experiment which improve and retrofit a seismic capacity by unequal angle bracing and carbon sheet attachment are carried out. These methods are also economic and simple in mitigating seismic hazard, improve earthquake-resistance performance, and reduce risk level of building occupants. From the experimental results, the change of strength, degration of stiffness, and energy dissipation are evaluated. It can be concluded that these methods are effective in improving the seismic performance.

  • PDF

데이터 전송률의 적응성을 고려한 CDMA2000 1X EV-DO 시스템의 순방향 데이터 서비스 용량 분석 (Forward Link Data Service Capacity Considering Data Rate Adaptation in CDMA2000 1X-EVDO Systems)

  • 최우용;임동구
    • 대한산업공학회지
    • /
    • 제37권3호
    • /
    • pp.229-233
    • /
    • 2011
  • The existing approaches for analyzing the data service capacity of CDMA2000 1X EV-DO (Evolution-Data Only) systems have focused on deriving the maximum number of active customers assuming that the data rates provided to the customers can be determined beforehand. However, we have seen that through real experiment, the data rates actually provided to the customers adaptively change according to the number of active customers. In this paper, we propose new capacity analysis model considering the data rate adaptation. Numerical examples are also presented to obtain the maximum input traffic rates for various values of the length of data burst and the required mean delay bound.

Climate Change Adaptive Implementation Assessment Proposal for Local Governments Utilizing Vulnerability Index

  • Lee, Sangsin
    • Journal of Forest and Environmental Science
    • /
    • 제35권1호
    • /
    • pp.47-53
    • /
    • 2019
  • This study applies the concept of climate change vulnerability assessment in order to suggest climate change adaptation effects in a quantitative manner, given that previous studies have hitherto rely on qualitative assessment, as climate change adaptive policies are currently being implemented by local governments of Korea. The vulnerability assessment tool used in this study is VESTAP ("Vulnerability assESsment Tool to build a climate change Adaptation Plan"), which was developed by the Korea Adaptation Center for Climate Change (KACCC), and applied to gauge the vulnerability of pine trees to diseases and pests within Chungcheongnam-do. The climate change adaptation project for vulnerability improvement was assessed only in terms of forest disaster prevention and change in regional climate change vulnerabilities within 16 regions of Chungcheongnam-do as the result of 2016 Climate Change Adaptation Project (Forest Disaster Prevention Project). As a result, it was observed that climate change adaptive capacity has improved according to change in the area of forestland with disaster prevention, and the vulnerability indicator decreased, confirming the impact of the climate change adaptation (forest disaster prevention) project. Also, analysis of regional climate change adaptation project scales and change in vulnerabilities allowed us to determine the regional propriety of climate change adaptation (forest disaster prevention) projects launched in 2016.

Thermal Behavior of Critical Micelle Concentration from the Standpoint of Flory-Huggins Model

  • Lim, Kyung-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권9호
    • /
    • pp.2001-2006
    • /
    • 2009
  • Temperature dependence of the critical micelle concentration (CMC), $x_{CMC}$, in micellization can be described by ln $x_{CMC}$ = A + BT + C lnT + D/T, which has been derived statistical-mechanically. Here A, B, C, and D are fitting parameters. The equation fits the CMC data better than conventionally used polynomial equations of temperature. Moreover, it yields the unique(exponent) value of 2 when the CMC is expressed in a power-law form. This finding is quite significant, because it may point to the universality of the thermal behavior of CMC. Hence, in this article, the nature of the equation ln $x_{CMC}$ = A + BT + C lnT + D/T is examined from a lattice-theory point of view through the Flory-Huggins model. It is found that a linear behavior of heat capacity change of micellization is responsible for the CMC equation of temperature.

객담을 동반한 중풍 환자에 마황량과 객담 배출 변화에 관한 보고 -정천탕, 해표이진탕을 이용하여- (Relation between Capacity Change of Ephedrae Herba and Sputum Secretion In Two Stroke Patients with High Levels of Sputum)

  • 노기환;강경숙;조기호;김영석
    • 대한한의학회지
    • /
    • 제22권1호
    • /
    • pp.96-103
    • /
    • 2001
  • Clinical symptoms of stroke patients vary widely, and include headache, dizziness, vomiting, dysphagia, dysphasia, incontinence, confusion, chest discomfort, dyspnea etc. Stroke patients who had chronic respiratory disease or had tracheostomy cannula usually have high levels of sputum, but there have been rare clinical reports about treatment of oriental medicine. High levels of sputum in stroke patients can cause pneumonia and dyspnea, and so can delay rehabilitation. By use of Haepyoleejin-tang.Jungchun-tang with change of Ephedrae Herba capacity, we could improve sputum secretion and respiratory function of two stroke patients, and so we report on the clinical course of two stroke patients with high levels of sputum.

  • PDF

거주자 요구를 고려한 수납면적에 관한 연구 (A Study on planning of storage area considering residents' needs)

  • 이세나;이현수
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2006년도 춘계학술발표대회 논문집
    • /
    • pp.193-196
    • /
    • 2006
  • The storage style has changed because of diversity of family types, improvement of cost of living, and increase of leisure time. In spite of this change, storage space has still caused discomfort since it did not consider residents' convenience. Therefore, in this study, Brand Apartments were selected, furniture detail drawing was analyzed by plan of housing size and zone to calculate storage area and capacity, and finally needs of storage space were analyzed using survey. Satisfaction of storage space was generally low and $20{\sim}30%$ increase of storage space was demanded. The reasons why the storage space was not satisfied are followed. First, storage space was insufficient. Second, the inner structure of storage space was unified. According to change of life style, needs have changed. To satisfy these needs, the inner division of storage space is planned with considering various items. In addition, development of hardware, flexible division, and priority of storage space with considering user's convenience are needed.

  • PDF

전력설비용 가교 Polyethlene의 Glass 전이점에서의 전기전도 특성에 관한 연구 (A Study on Electric Conduction Characteristic in the Glass Transition Point of electric Power Equipments Cross - Linked Polyethylene)

  • 김강원;서장수;김병인;국상훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1991년도 추계학술발표회논문집
    • /
    • pp.64-68
    • /
    • 1991
  • It happened that there was a sudden peak with the capacity of change, when I measured the capacity of change, cubical expansion and Thermally Stimulated Current on the Cross - Linked Polythylene. Crystal melting began at 375 K and changed into formaless shapeless at 380 K. The conduct of a particle on the surfase of dipole, electron trap was founded to be ion conduction nature under the low electronic field, wherase, the electron nature under the high electronic field. Consequentity, under the semi-conduction layer electronic a particle was injected to inter-fase and accumulated for a time and appeared to be TSC.

  • PDF

Rietveld Refinement of Oxysulfide $LiAl_{0.24}Mn_{1.76}O_{4-y}S_y (y=0, 0.02)$ Spinel Materials

  • Park, Hyun-Min;Y.K Cho;Sun, Yang-Kook
    • 한국결정학회지
    • /
    • 제14권2호
    • /
    • pp.110-114
    • /
    • 2003
  • LiAl/sub 0.24/Mn/sub 1.76/O/sub 4-y/S/sub y/ (y=0, 0.02) were synthesized by the sol-gel method. Both structures were refined by Rietveld method, its structure refined as a cubic spinel, space group Fd-3m, a=8.17937(30) Å and 8.18331(19) Å respectively. Though it has been made a charge/discharge experiment above 20 times, there was no change of 3 V/4 V capacity degradation. It was considered that the volume change of MnO/sub 6/ octahedron induced by sulfur substitution plays a key role in keeping the 3 V/4 V capacity. The refined composition of the compound could be confirmed with the ICP analysis.