• Title/Summary/Keyword: center loss

Search Result 3,752, Processing Time 0.043 seconds

Quality Characteristics on Adding Blood Levels to Blood Sausage (혈액 첨가 수준에 따른 혈액소시지의 품질 특성)

  • Choi, Yun-Sang;Sung, Jung-Min;Jeon, Ki-Hong;Choi, Hyun-Wook;Seo, Dong-Ho;Kim, Cheon-Jei;Kim, Hyun-Wook;Hwang, Ko-Eun;Kim, Young-Boong
    • Korean journal of food and cookery science
    • /
    • v.31 no.6
    • /
    • pp.741-748
    • /
    • 2015
  • This study evaluated the effects of adding blood levels to phycochemical properties, textural properties, and sensory characteristics of blood sausage. 4 treatment groups of blood sausage were produced, T1 (pork ham : pork blood = 60:15), T2 (55:20), T3 (50:25), and T4 (45:30). T1 had the highest moisture content, most cohesiveness, and gumminess, CIE L-value, CIE a-value, and CIE b-value of raw and cooked blood sausages. Protein content, fat content, ash content, and VBN values were not significantly different among the treatments. T4 was treated with the most added pork blood, and had the highest pH of raw and cooked blood sausages, cooking loss, and TBA values. T2's sausage was the hardest, but had more springiness, cohesiveness, gumminess, and chewiness than T4. The best scores were from T4 and had the most overall acceptability. The results of this study show that blood sausages containing 20% pork blood had higher improved quality characteristics in blood sausages.

Changes in Skin Parameters after Sequential Tape Stripping (Sequential Tape Stripping에 따른 피부 Parameters의 변화에 관한 연구)

  • Kim, Seung-Hun;Kim, Eun-Joo;Nam, Gae-Won;Ahn, Sung-Yeon;Lee, Hae-Kwang;Moon, Seong-Joon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.33 no.2
    • /
    • pp.99-104
    • /
    • 2007
  • The skin barrier function is one of the vital functions. Horny layer and epidermis among various skin layers play an important role in protecting body from environmental insults. Stratum corneum is completely formed by differentiation processes from the basal layer and newly formed corneocytes push the older ones from skin surface. In this study we investigated changes of various parameters - capacitance, transepidermal water loss (TEWL), pH and amount of removed corneocytes - according to the stratum corneum's depth. We removed the stratum corneum using tape stripping technique. We found that uppermost stratum corneum play an important role in skin surface moisturization and lower stratum corneum in protecting transepidermal water loss. In addition, skin pH is more acidic than surface pH. In the stratum corneum, skin pH is mote acidic in the deeper layer. Furthermore amount of removed corneocyte is also decreased according to depth because of stronger cell-cell union strength. From these results we suggest that stratum corneum has different characteristics depending on their position.

A Canine Model of Tracheal Stenosis Using Nd-YAG Laser (Nd-YAG laser를 이용한 기관협착 동물모델의 개발)

  • Kim, Jhin-Gook;Suh, Gee-Young;Chung, Man-Pyo;Kwon, O-Jung;Suh, Soo-Won;Kim, Ho-Joong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.1
    • /
    • pp.54-61
    • /
    • 2002
  • Background: Tracheal stenosis is an urgent but uncommon disease. Therefore, primary care clinicians have limited clinical experience. Animal models of a tracheal stenosis can be used conveniently for the learning, teaching, and developing new diagnostic and therapeutic modalities for tracheal stenosis. Recently, a canine model of a tracheal stenosis was developed using a Nd-YAG laser. To describe the methods and results of developed animal model, we performed this study. Methods : Six Mongrel dogs were generally anesthetized and the anterior 180 degree of tracheal cartilage of the animal was photo-coagulated using a Nd-YAG laser. The animals were bronchoscopically evaluated every week for 4 weeks and a pathologic evaluation was also made. Results : Two weeks after the laser coagulation, the trachea began to stenose and the stenosis progressed through 4 weeks. All animals suffered from shortness of breath, wheezing, and weight loss in the 3 weeks after the laser treatment, and two died of respiratory failure just before the fourth week. The gross pathologic findings showed the loss of cartilage and a dense fibrosis, which resulted in a fibrous stricture of the trachea. Microscopy also showed that the fibrous granulation tissue replaced destroyed cartilage. Conclusion : The canine model can assist in the understanding and development of new diagnostic and therapeutic modalities for tracheal stenosis.

Enhanced Transdermal Delivery of Drug Compounds Using Scalable and Deformable Ethosomes (에토좀 입자크기와 멤브레인 특성 조절을 통한 약물의 경피흡수능 향상)

  • An, Eun-Jung;Shim, Jong-Won;Choi, Jang-Won;Kim, Jin-Woong;Park, Won-Seok;Kim, Han-Kon;Park, Ki-Dong;Han, Sung-Sik
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.36 no.2
    • /
    • pp.105-113
    • /
    • 2010
  • This study introduces a flexible approach to enhance skin permeation by using ethosomes with deformable lipid membranes as well as controllable sizes. To demonstrate this, a set of ethosomes encapsulating an anti-hair loss ingredient, Triaminodil$^{TM}$, as a model drug, were fabricated with varying their size, which was achieved by solely applying the different level of mechanical energy, while maintaining their chemical composition. After characterization of the ethosomes with dynamic light scattering, transmission electron microscopy, and deformability measurements, it was found that their membrane deformability depended on the particle size. Moreover, studies on in vitro skin permeation and murine anagen induction allowed us to figure out that the membrane deformability of ethosomes essentially affects delivery efficiency of Triaminodil$^{TM}$ through the skin. It was noticeable in our study that there existed an optimum particle size that can not only maximize the delivery of the drug through the skin, but also increase its actual dermatological activity. These findings offer a useful basis for understanding how ethosomes should be designed to improve delivery efficiency of encapsulated drugs therein in the aspects of changing their length scales and membrane properties.

Comparison of marginal bone loss and patient satisfaction in single and double-implant assisted mandibular overdenture by immediate loading

  • Tavakolizadeh, Sara;Vafaee, Fariborz;Khoshhal, Masume;Ebrahimzadeh, Zahra
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.191-198
    • /
    • 2015
  • PURPOSE. The purpose of this study was to compare the coronal bone level and patient satisfaction in 1-implant and 2-implant assisted mandibular overdentures. MATERIALS AND METHODS. Twenty patients who had maladaptive mandibular dentures were treated in this study. Patients were randomly divided into two groups. The first group received 1 implant (Simple line II, Implantium, South Korea) in their mandibular midline and the second group received 2 implants in their B and D regions (according to Misch's category). If the primary stability of each implant was at least 60 ISQ, ball attachment was placed and denture relined with soft liner. After 6 weeks, retentive cap incorporated with hard acrylic resin. In the 6 and 12 months recalls, periapical digital radiograph were made and visual analogue scale questionnaires were used to record patient satisfaction. The Friedman test was done for comparing the presurgical and postsurgical parameters in each group and the U-Mann Whitney test (P<.05) was done for comparison of post-treatment results between the two groups. RESULTS. All implants achieved sufficient primary stability to be immediately loaded. Patient satisfaction was high, and there were no significant differences between two groups (P>.05). In addition, mean marginal bone loss was $0.6{\pm}0.67$ mm in the first group and $0.6{\pm}0.51$ mm in the second group, after 12 month. Mean marginal bone loss showed no significant differences between two groups. CONCLUSION. This preliminary one-year result indicated that mandibular overdentures anchored to a single implant can be a safe and cost-effective method as a starting step for implant-overdenture treatment.

Compact S-Band Antenna Hat for RF Compatibility Testing of Launch Vehicle (발사체의 RF 호환성 시험을 위한 소형 S-밴드 안테나 햇)

  • Kim, Sung-Wan;Park, Dong-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.2
    • /
    • pp.148-157
    • /
    • 2015
  • In this paper, we propose a compact antenna hat to perform RF compatibility testing efficiently between the launch vehicle and ground stations. The proposed structure implements a small size and low loss using the conductive shield instead of the conventional RF absorber. The S-band antenna hat, which is fabricated for an inverted-F onboard antenna with the size of $74mm{\times}13mm{\times}16mm$, has the small enclosure of $88mm{\times}35mm{\times}44mm$, the return loss of 25.6 dB, the insertion loss of 0.26 dB, and the leakage loss of 49.4 dB at the center frequency of 2.25 GHz. The simulated and measured results show a good agreement.

Resistance of Methyl Methacrylate-Impregnated Wood to Subterranean Termite Attack

  • Hadi, Yusuf Sudo;Massijaya, Muh. Yusram;Zaini, Lukmanul Hakim;Abdillah, Imam Busyra;Arsyad, Wa Ode Muliastuty
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.6
    • /
    • pp.748-755
    • /
    • 2018
  • Timber from fast-growing tree species is susceptible to by biodeterioration attack, particularly subterranean termites. Impregnation with methyl methacrylate (MMA) potentially increases wood resistance to subterranean termite attack. Four wood species, namely sengon (Falcataria moluccana), jabon (Anthocephalus cadamba), mangium (Acacia mangium), and pine (Pinus merkusii), were impregnated with MMA, and samples of untreated and imidacloprid-preserved wood were prepared for comparison purposes. Small stakes, sized 0.8 cm by 2 cm in cross section by 20 cm in the longitudinal direction, were inserted into the ground for 3 months, and the weight loss of each specimen was determined at the end of the test period. A factorial $4{\times}3$ completely randomized design was used for data analysis; the first factor was wood species, and the second factor was treatment. The results showed that MMA polymer loadings were 27.88%, 24.91%, 14.14%, and 17.81% for sengon, jabon, mangium, and pine, respectively, and amounts of imidacloprid retention were $7.56kg/m^3$, $5.98kg/m^3$, $5.34kg/m^3$, and $9.53kg/m^3$, respectively. According to an analysis of variance, wood species, treatment, and interaction of both factors significantly affected the weight loss of wood specimens. Mangium had the smallest weight loss, followed by pine, sengon, and jabon. MMA impregnation into the wood increased the resistance of wood samples to subterranean termite attack during in-ground testing, but the resistance level was lower than that of imidacloprid-preserved wood. Except for mangium wood, the MMA treatment did not significantly affect resistance.

Comparison of Nano Particle Size Distributions by Different Measurement Techniques

  • Bae, Min-Suk;Oh, Joon-Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.2
    • /
    • pp.219-233
    • /
    • 2010
  • Understanding the Nano size particles is of great interest due to their chemical and physical behaviors such as compositions, size distributions, and number concentrations. Therefore, accurate measurements of size distributions and number concentrations in ultrafine particles are getting required because expected losses such as diffusion for the instrument system from ambient inlet to detector are a significant challenge. In this study, the data using the computed settling losses, impaction losses, diffusion losses for the sampling lines (explored different sampling line diameters, horizontal length, number of bending, line angles, flow rates with and without a bypass), and diffusion losses for the Scanning Mobility Particle Sizers are examined. As expected, the settling losses and impaction losses are very minor under 100 nm, however, diffusion loss corrections for the sampling lines and the size instrument make a large difference for any measurement conditions with high numbers of particles smaller mobility size. Both with and without the loss corrections, which can affect to size distributions and number concentrations are described. First, 80% or more of the smallest particles (less than 10 nm) can be lost in the condition of a flow rate of 0.3 liter per minute and the length of sampling line of 1.0 m, second, total number concentrations of measurements are quite significantly affected, and the mode structure of the size distribution changes dramatically after the loss corrections applied. With compared to the different measurements, statistically diffusion loss corrections yield a required process of the ambient particle concentrations. Based on the current study, as an implication, a possibility of establishing direct revelation mechanisms is suggested.

A Study on the development of high power ceramic waveguide filter for UMTS (UMTS용 고출력 세라믹 도파관 필터 개발에 관한 연구)

  • Lim, Kwang-Taeg
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.5
    • /
    • pp.1164-1171
    • /
    • 2008
  • The present study, which is about a ceramic waveguide filter for UMTS, designed a filer using a circuit and structure simulator, suggested a design method at a required frequency band, and developed a waveguide filter, which can be applied at a power of over 50W and be miniaturized, through implementing the design and examining related variables and characteristics. In the results of designing a waveguide filter with the center frequency of 1,950 MHz and 2,140 MHz and examining its characteristics, bandwidth was 60MHz, insertion loss was below 1.0dB, return loss was over 20dB, and attenuation at the relative frequency band was over 60dB. In the results of a power station test, the characteristics did not change and internal temperature was below $30^{\circ}C$ at 50.8W, and this confirmed that the filter is usable at over 50W.

Low Conversion Loss and High Isolation W-band MMIC Mixer Module (낮은 변환 손실 및 높은 격리 특성의 W-band MMIC 믹서 모듈)

  • An, Dan;Rhee, Jin-Koo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.50-54
    • /
    • 2015
  • In this paper, we report on a high performance 94 GHz MMIC mixer module using 0.1-um metamorphic high electron mobility transistors (MHEMTs). A modified resistive mixer with a RF amplifier was proposed in this work for low conversion loss and high LO-RF isolation. The MMIC mixer module was fabricated using a MMIC chip and CPW-waveguide transitions. The fabricated mixer chip and module showed a low conversion loss of 6.3 dB and 9.5 dB, and LO-RF isolations of 24.8 and 30.4 dB at 94 GHz, respectively. This results are superior to those of previously W-band (75-110 GHz) MMIC mixers.