• Title/Summary/Keyword: center loss

Search Result 3,752, Processing Time 0.033 seconds

Reconstruction of Defect Adjacent to the Buttock with Gluteal Perforator Flap: Free Style Flap Design (둔부천공지피판의 둔부 인접 부위로의 적용: 둔부천공지피판의 자유로운 작도)

  • Lee, Muyoung;Choi, Jong-Woo;Hong, Joon-Pio;Koh, Kyung-S;Eom, Jin Sup
    • Archives of Plastic Surgery
    • /
    • v.35 no.6
    • /
    • pp.692-697
    • /
    • 2008
  • Purpose: Gluteal perforator flap has evolved to one of the standard tools for coverage of pressure sore. We used this flap to cover the defect adjacent to the buttock. Methods: From September 2004 to August 2006, gluteal perforator flaps were performed in 3 patients with sore and 9 patients with tumor. We made the rule for free style design of the flap. First, the defect should be covered fully regardless of the shape or area. Second, the location of perforators was decided to maximize flap mobility. Third, the donor-site should be closed directly. Results: Successful reconstruction was fulfilled. In 2 cases, initial flap congestion was observed but medical leech was applied and it was resolved. Partial flap loss occurred in one case. Infection was observed in one case. But there were no major complications. Conclusion: Gluteal perforator flap is very good option for the reconstruction of the defects adjacent to the buttock.

Various Techniques for Improving of the Reliability of the Wireless Network Design/Optimization Simulation Tool (무선망 설계/최적화 시뮬레이션 툴 의 다양한 신뢰도 향상 기법)

  • Jeon Hyun-Cheol;Ryu Jae-Hyun;Park Sang-Jin;Park Joo-Yeoul;Kim Jung-Chul
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.39-42
    • /
    • 2006
  • There are various analysis functions(including prediction of path loss, analyzing of capacity and coverage, etc.) of simulation tool to design and optimize the mobile communication network. Its reliability absolutely effects the performance of mobile communication network. Especially as the wireless network highly advancing focused on data service, it more needs to research and develop on the standard establishment of reliability of the simulation tool. Also it is important the systematic research how to improve the reliability of simulation tool. In this paper, to give the concrete process and skill about how to improve reliability, we define the kinds of reliability at first. And then we explain the comparison results between real field measurement data and theoretic simulation data.

  • PDF

C-terminally mutated tubby protein accumulates in aggresomes

  • Kim, Sunshin;Sung, Ho Jin;Lee, Ji Won;Kim, Yun Hee;Oh, Yong-Seok;Yoon, Kyong-Ah;Heo, Kyun;Suh, Pann-Ghill
    • BMB Reports
    • /
    • v.50 no.1
    • /
    • pp.37-42
    • /
    • 2017
  • The tubby protein (Tub), a putative transcription factor, plays important roles in the maintenance and function of neuronal cells. A splicing defect-causing mutation in the 3'-end of the tubby gene, which is predicted to disrupt the carboxy-terminal region of the Tub protein, causes maturity-onset obesity, blindness, and deafness in mice. Although this pathological Tub mutation leads to a loss of function, the precise mechanism has not yet been investigated. Here, we found that the mutant Tub proteins were mostly localized to puncta found in the perinuclear region and that the C-terminus was important for its solubility. Immunocytochemical analysis revealed that puncta of mutant Tub co-localized with the aggresome. Moreover, whereas wild-type Tub was translocated to the nucleus by extracellular signaling, the mutant forms failed to undergo such translocation. Taken together, our results suggest that the malfunctions of the Tub mutant are caused by its misfolding and subsequent localization to aggresomes.

Design Methodology for Transformers Including Integrated and Center-tapped Structures for LLC Resonant Converters

  • Jung, Jee-Hoon;Choi, Jong-Moon;Kwon, Joong-Gi
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.215-223
    • /
    • 2009
  • A design methodology for transformers including integrated and center-tapped structures for LLC resonant converters is proposed. In the LLC resonant converter, the resonant inductor in the primary side can be merged in the transformer as a leakage inductance. And, the absence of the secondary filter inductor creates low voltage stress on the secondary rectifiers and is cost-effective. A center-tapped structure of the transformer secondary side is widely used in commercial applications because of its higher efficiency and lower cost than full-bridge structures in the rectifying stages. However, this transformer structure has problems of resonance imbalance and transformer inefficiency caused by leakage inductance imbalance in the secondary side and the position of the air-gap in the transformer, respectively. In this paper, gain curves and soft-switching conditions are derived by first harmonic approximation (FHA) and operating circuit simulation. In addition, the effects of the transformer including integrated and center-tapped structures are analyzed by new FHA models and simulations to obtain an optimal design. Finally, the effects of the air-gap position are analyzed by an electromagnetic field simulator. The proposed analysis and design are verified by experimental results with a 385W LLC resonant converter.

A study on speech analysis of person with presbycusis (노인성 난청인의 음성특성에 관한 연구)

  • Lee, S.M.;Song, C.G.;Woo, H.C.;Lee, Y.M.;Kim, W.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.67-70
    • /
    • 1997
  • In this paper, we evaluated the character of speech of hearing impaired person (HIP) who acquire his hearing loss after the youth. It is usually observed that severe HIP decreased not only speech perception but also vocalization. so there is a need for sensitive and quantitative measures or the assesment of the speech of the HIP to serve both diagnostic and prognosic purposes, 7 HIP and 12 normal hearing person(NHP) were studied with pure tone test and speaking test using word/sentence table which consists of vowel(a:), mono and two syllables and a sentence. we analyzed formant frequency, pitch, sound intensity, speech duration of HIP and NHP speech. According to the results, in the HIP's speech we find that formant frequency was shifted, first-formant prominence was reduced, the dynamic range of sound intensity was decreased, speech duration was prolonged. In the next, we expect the correlation between hearing and speech character of HIP is cleared through analysis of more acoustic parameters and precise selection of HIP group.

  • PDF

Longitudinal Supraspinatus Tear Associated with Antegrade Humeral Intramedullary Nailing: A Case Report and Literature Review with Focus Placed on Nail Entry Point

  • Shon, Min Soo;Bang, Tae Jung;Yoo, Jae Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.1
    • /
    • pp.47-51
    • /
    • 2015
  • Iatrogenic damage of the rotator cuff followed by postoperative shoulder function loss is a potential complication after antegrade intramedullary nailing (AIN) for a humeral fracture. The authors present a case of arthroscopic rotator cuff repair and subacromial decompression of a non-healed rotator cuff tendon (mainly supraspinatus) and secondary impingement syndrome caused either by the tear or a proud nail after AIN for a mid-shaft humeral fracture. At presentation, the patient complained of right shoulder pain and 'snapping', especially during forward elevation and abduction of the shoulder, of 4 years duration. Right shoulder pain started sometime after pain due to the humeral shaft fracture, operation had subsided, and persisted after nail removal. Arthroscopic findings showed a longitudinal rotator cuff tear at the nail entry point that had not healed and severe fibrous hypertrophy on the acromion underspace, which is a unique finding since most longitudinal splits of tendon fibers are more likely to heal than conventional rotator cuff tears detached from bone. The torn rotator cuff was repaired after debridement and placing side-to-side sutures. At his 34-month follow-up after rotator cuff repair, the patient showed complete recovery and had excellent clinical scores.

Microstructures and Mechanical Properties of AZ31-(0~0.5%)Ca alloys (AZ31-(0~0.5)%Ca 합금의 미세조직과 기계적 성질)

  • Jun, Joong-Hwan;Park, Bong-Koo;Kim, Jeong-Min;Kim, Ki-Tae;Jung, Woon-Jae
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.17 no.5
    • /
    • pp.299-304
    • /
    • 2004
  • Influence of Ca addition on microstructure and room temperature mechanical properties has been studied for AZ31(Mg-3%Al-1%Zn-0.2%Mn)-(0~0.5)%Ca wrought alloys, based on experimental results from metallography, X-ray diffractometry and mechanical tests. Yield strength, ultimate tensile strength and hardness of the alloys increased remarkably with increasing Ca content, whereas elongation was deteriorated continuously. Microstructural examination revealed that Ca addition efficiently refined grains of ${\alpha}$(Mg) phase and that some of the Ca dissolved in ${\beta}(Mg_{17}Al_{12})$ precipitates. The former and the latter facts are thought to be responsible for improved strength and loss of ductility of the AZ31+Ca wrought alloys, respectively.

A Probiotic Preparation Duolac-Gold Ameliorates Dextran Sulphate Sodium-induced Mouse Colitis by Downregulating the Expression of IL-6

  • Yoon, Hyunho;Yoon, Yeo-Sang;Kim, Min-Soo;Chung, Myung-Jun;Yum, Do-Young
    • Toxicological Research
    • /
    • v.30 no.1
    • /
    • pp.27-32
    • /
    • 2014
  • Probiotics are live microorganisms that confer a health benefit on the host. Duolac-Gold is a mixture of seven probiotic bacteria containing three species of Bifidobacteria, two species of Lactobacillus, and Streptococcus thermophilus. The aim of this study was to assess the anti-inflammatory effects of Duolac-Gold in an inflammatory bowel disease (IBD) mouse model. IBD was induced by administering 1.5% dextran sulfate sodium (DSS) for 10 days. After induction of DSS-induced colitis, Duolac-Gold was orally administered at three different concentrations. Interestingly, Duolac-Gold treatment accelerated IBD healing, and anti-inflammatory activity was assessed by weight loss, length of the colon, and a microscopic damage score by histology. The expression of inflammatory related cytokines was measured in colon tissues and serum. Of these cytokines, the expression of interleukin-6 decreased remarkably after Duolac-Gold treatment. Taken together, these results suggest that Duolac-Gold treatment is effective in IBD healing by regulating IL-6.

Microwave Negative Group Delay Circuit: Filter Synthesis Approach

  • Park, Junsik;Chaudhary, Girdhari;Jeong, Junhyung;Jeong, Yongchae
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.1
    • /
    • pp.7-12
    • /
    • 2016
  • This paper presents the design of a negative group delay circuit (NGDC) using the filter synthesis approach. The proposed design method is based on a frequency transformation from a low-pass filter (LPF) to a bandstop filter (BSF). The predefined negative group delay (NGD) can be obtained by inserting resistors into resonators. To implement a circuit with a distributed transmission line, a circuit conversion technique is employed. Both theoretical and experimental results are provided for validating of the proposed approach. For NGD bandwidth and magnitude flatness enhancements, two second-order NGDCs with slightly different center frequencies are cascaded. In the experiment, group delay of $5.9{\pm}0.5ns$ and insertion loss of $39.95{\pm}0.5dB$ are obtained in the frequency range of 1.935-2.001 GHz.

Development of a Real-Time Water Quality Monitoring System using Coastal Passenger Ships and PCS Telemetry

  • Jin, Jae-Youll;Park, Jin-Soon;Lee, Jong-Kuk;Park, Kwang-Soon;Lee, Dong-Young;Yum, Ki-Dai
    • Ocean and Polar Research
    • /
    • v.21 no.2
    • /
    • pp.117-126
    • /
    • 1999
  • To meet increasing needs for environmentally sustainable management of coastal area, there has been compelling pressure to establish a cost-effective and long-term coastal water quality (CWQ) monitoring system. A remote CWQ monitoring system, STAMP, has been developed and is in operation along the route between Kyema harbor and Anma Island in the southwestern coastal area of Korea. STAMP uses a PCS phone as a telemetry unit to transmit acquired data for monitoring general water quality parameters, and a routinely operating coastal passenger ship or car ferry. STAMP has various merits of low-cost operations; long-term monitoring with secure instrumentation; and stable real-time telemetry of acquired data with-out the loss and noise. It is expected that the system will serve as a very useful tool in the CWQ managing programs of Korea taking the advantage of many coastal passenger ships in various routes including the ships departing from the coastal industrial cities. The acquired data compiled on suspended surface sediment concentrations (SSSC) will be also valuably helpful in understanding the sediment budget across the routes of the vessel.

  • PDF