• Title/Summary/Keyword: center loss

Search Result 3,752, Processing Time 0.045 seconds

Errors in the Triangular Fin Analysis under Assuming the Fin Tip is Insulated (핀끝이 절연되었다는 가정하에 삼각핀 해석에서의 오차)

  • 강형석;김성준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.7
    • /
    • pp.1783-1788
    • /
    • 1994
  • A comparison of the temperature distributions along the wall and center of the fin and the heat loss from the fin, computed assuming the fin tip is insulated and assuming it is not insulated in a triangular fin, is performed by the two-dimensional forced analytic method. When the fin tip is not insulated, a comparison between forced analytic method and analytic method is made in the heat loss and temperature along the fin wall. The value of Biot number varies from 0.01 to 1.0. The root temperature and surrounding convection coefficients of the fin are assumed as a constant. The results are (1) the analysis on the triangular fin assuming the fin tip is insulated does not produce a good value as compared to that of not-insulated case as the non-dimensional fin length decreases and as the value of Biot number increases and (2) the errors between forced analytic method and analytic method are very small, but the former method is better for computer running time and accuracy.

Acid-base Balance and Metabolic Acidosis in Neonates (신생아의 산-염기 균형과 대사성 산증)

  • Lee, Byong-Sop
    • Neonatal Medicine
    • /
    • v.17 no.2
    • /
    • pp.155-160
    • /
    • 2010
  • Metabolic acidosis is commonly encountered issues in the management of critically ill neonates and especially of preterm infants during early neonatal days. In extremely premature infants, low glomerular filtration rate and immaturity of renal tubules to produce new bicarbonate causes renal bicarbonate loss. Higher intake of amino acids, relatively greater contribution of protein to the energy metabolism and mineralization process in growing bones are also responsible for higher acid load in premature infant than in adult. Despite widespread use of sodium bicarbonate in the management of severe metabolic acidosis, use of sodium bicarbonate in premature infants should be restricted to a reasonable but unproven exception such as ongoing renal loss. Despite concern about the low pH value (<7.2) which can compromise cellular metabolic function, no treatment guideline has been established regarding the management of metabolic acidosis in premature infants. Appropriately powered randomized controlled trials of base therapy to treat metabolic acidosis in critically ill newborn infants are demanding.

A Study on the Noise and Vibration Transmission Path of Rolling Pistion Type Rotary Compressor Using SEA (통계적 에너지 해석 기법에 의한 공조용 로타리 압축기의 소음 진동 전달 경로 해석)

  • Hwang, Seon-Woong;Jeong, Hyeon-Chul;Ahn, Byung-Ha;Jeong, Weui-bong;Kim, Kyu-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.385.2-385
    • /
    • 2002
  • Hermetic rotary compressor is one of the most important components for air conditioning system since it has a great effect on both the performance and the noise and vibration of the system. Noise and vibration of rotary compressor is occurred due to gas pulsation during compression process and unbalanced dynamic force. In order to reduce noise and vibration, it is necessary to identify sources of noise and vibration and effectively control them. (omitted)

  • PDF

Effects of PCB Ground Plane and Case on Internal WLAN Patch Antenna

  • Kim, H.T.;Heo, J.K.;Jeong, K.J.;Hwang, S.W.
    • Journal of IKEEE
    • /
    • v.11 no.4
    • /
    • pp.252-256
    • /
    • 2007
  • We demonstrate that the effect of the PCB ground length and the cover is important in the performance of 2.4 GHz patch antennas. The Center frequency in the return loss shifts as much as 0.5 GHz, when the length of the PCB ground increases from 30 to 85 mm. The position of 10-dB bandwidth accordingly shifts to lower frequency region. Finally, the resonance at 2.4 GHz becomes stronger when the top cover exists. The radiation pattern of the patch antenna is also strongly affected by the ground structure and the existence of the top cover. In both the return loss and the radiation pattern, 3-dimensional simulations are shown to be an efficient tool.

  • PDF

Study on the Test Method for Measuring Vibration Damping Properties using Bae Type Specimen (시험 방법에 따른 바(Bar) 형 시편의 동특성 비교)

  • Lee, Yong-Bong;Kwon, Hyu-Sang;Jung, Sung-Soo;Jun, Byung-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1939-1944
    • /
    • 2000
  • Different test methods were used to measure and compare the loss factor of a steel beam. They are free vibration logarithmic decay method, half-power bandwidth method using narrow-band analysis, wide-band analysis method with inverse FFT. In these tests, specimens are clamped at one end. Free vibration method and half-power bandwidth method gave good results. Effect of vibration pick-ups were tested. We also tried center excitation method but could not obtain loss factor.

  • PDF

Ka-band high-$T_c$ superconductor and III-V semiconductor hybrid balanced mixer

  • Kwak, M.H.;Suh, J.D.;Kang, Kwang-Yong;Han, S.K.
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.15-20
    • /
    • 2000
  • We demonstrated a single balanced mixer of the combination of high-T. superconductor (HTS) and III-V GaAs beam lead Schottky diodes operating in the mini-cryogenic chamber. The HTS hybrid mixer was designed with a center frequency of 27.5 GHz and a bandwidth of 1 GHz, and consisted of a rat-race coupler circuit with beam-lead diodes attached to its balanced ports. The HTS hybrid mixer with 1 GHz RF bandwidths exhibits a conversion loss of 6 dB. A LO-to-RF isolation was greater than 40 dB in the range of operating frequencies. Since the HTS/III-V hybrid mixer devices have lower noise and conversion loss, this technique provide us with new capabilities that can be effectively utilized in the field of local-point distribution service (LMDS) systems.

  • PDF

Design of LTCC(Low Temperature Co-fired Ceramic) Bandpass Filter to Improve Characteristic of Rejection Band (저지대역 특성을 개선한 LTCC 대역 통과 여파기 설계)

  • Kim, Young-Ju;Park, Jun-Seok;Lim, Jae-Bong;Cho, Hong-Goo
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.256-259
    • /
    • 2003
  • In this paper, a design of multi-layered BPF(bandpass filter) using LTCC(Low Temperature Co-fired Ceramic) process by a lumped-elements is proposed for SOP(system-on-a-chip) of wireless communication systems. The proposed BPF improved a characteristic of rejection band to build an attenuation pole caused by structurally adjacent co-inductance and coupling. The simulation data shows a bandwidth of 90MHz from a center frequency of 2.4GHz, a return loss of 27dB, an insertion loss of 3.2dB, and an attenuation of at least 20dBc at $f_0{\pm}250MHz$. Simulations have used serenade circuit simulation and HFSS EM simulation.

  • PDF

Sleep Disordered Breathing and Nasal Obstruction (수면호흡장애와 코막힘)

  • Chung, Yoo-Sam
    • Sleep Medicine and Psychophysiology
    • /
    • v.12 no.2
    • /
    • pp.93-97
    • /
    • 2005
  • Nasal obstruction may cause or aggravate sleep disordered breathing but exact pathogenesis is not clear. The possible mechanism could be combination of alteration in upper airway aerodynaimcs, loss of nasal reflex or sensation, effect of mouth opening, and a genetic predisposition. Anatomical narrowing of nasal airway cause more rapid airflow and induce more negative inspiratory air pressure. So, it increases collapsibility of pharyngeal airway. Loss of nasal sensation to airflow block nasal reflex. Mouth opening decreases the activity of pharyngeal airway dilator muscles and narrowing the pharyngeal airway may occur. The treatment of nasal obstruction should be done according to the cause. The causes of nasal obstruction are various from problems of external nasal opening to nasopharynx. Relief of nasal obstruction may not cure sleep disordered breathing always. In some mild obstructive sleep apnea patients, treatment of nasal obstruction only may cure sleep disordered breathing. In some severe sleep apnea patients, treatment of nasal obstruction may increase compliance of continous nasal positive airway pressure.

  • PDF

Early Postmortem Processing Conditions on Meat Quality of Hanwoo (Korean Native Cattle) Beef during Storage

  • Kim, B.C.;Rhee, M.S.;Ryu, Y.C.;Imm, J.Y.;Koh, K.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.12
    • /
    • pp.1763-1768
    • /
    • 2001
  • The combined effects of low voltage electrical stimulation (ES) and early short-term temperature conditioning on meat quality of Hanwoo beef (Korean native cattle) during storage were investigated. Shear force was influenced by ES and aging. Combination of ES and the $30^{\circ}C$ conditioning resulted in higher myofibril fragmentation index and improved lightness. There was no substantial difference in drip loss among treatments but ES samples showed higher cooking loss than control. Negative effect on shelf-life was not found by early short-term high temperature conditioning. Therefore, the meat quality of Korean native cattle was effectively improved by the combination of ES and the $30^{\circ}C$ conditioning.

A Study on Feedforward System for IMT-2000

  • Jeon, Joong-Sung;Choi, Dong-Muk;Kim, Min-Jung
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.1176-1185
    • /
    • 2005
  • A linear power amplifier is particularly emphasized on the system using a linear modulations, such as 16QAM and QPSK with pulse shaping, because intermodulation distortion which causes adjacent channel interference and co-channel interference is mostly generated in a nonlinear power amplifier. In this paper, parameters of a linearization loop, such as an amplitude imbalance, a phase imbalance and a delay mismatch, are briefly analyzed to get a specific cancellation performance and linearization bandwidth. Experimental results are presented for IMT-2000 frequency band. The center frequency of the feedforward amplifier is 2140 MHz with 60 MHz bandwidth. When the average output power of feedforward amplifier is 20 Watt, the intermodulation cancellation performance is more than 21 dB. In this case, the output power of feedforward amplifier reduced 3.5 dB because of extra delay line loss and coupling loss. The feedforward amplifier efficiency is more than 7.2 % for multicarrier signals, 59 dBc for ACPR.

  • PDF