• Title/Summary/Keyword: center loss

Search Result 3,752, Processing Time 0.044 seconds

Effects of 1-methylcyclopropene (1-MCP) on Fruit Quality and Occurrence of Physiological Disorders of Asian Pear (Pyrus pyrifolia), 'Wonhwang' and 'Whasan', during Shelf-life (동양배 '원황' 및 '화산'의 상온유통 중 품질 및 생리장해 발생에 미치는 1-methylcyclopropene (1-MCP) 처리의 영향)

  • Lee, Ug-Yong;Oh, Kyoung-Young;Moon, Seung-Joo;Hwang, Yong-Soo;Chun, Jong-Pil
    • Horticultural Science & Technology
    • /
    • v.30 no.5
    • /
    • pp.534-542
    • /
    • 2012
  • This study was conducted to investigate the effect of 1-methylcyclopropene (1-MCP) on fruit quality and incidence of physiological disorders for keeping freshness during marketing period in Asian pear (Pyrus pyrifolia Nakai) 'Wonhwang' and 'Whasan'. Fruits were treated with $1{\mu}L{\cdot}L^{-1}$ 1-MCP for 12 hours at $25^{\circ}C$, at two or three stages of ripeness as determined by days after full bloom (DAFB). Fruits were harvested at 130 and 140 DAFB in early season cultivar 'Wonhwang' and 135, 145, and 150 DAFB in mid-season cultivar 'Whasan', respectively. Fruits were stored at $25^{\circ}C$ for 21 days and measured the flesh firmness, weight loss, soluble solids, acidity, ethylene, respiration and severity of physiological disorders at week interval. 1-MCP treatment to 'Wonhwang' pears harvested at 130 and 140 DAFB effectively delayed firmness loss during storage at $25^{\circ}C$. Untreated fruits of 'Wonhwang' pears harvested at 130 DAFB showed 32.3 and 10.1N of firmness after 14 and 21 days of shelf-life at $25^{\circ}C$, respectively, while those of the 1-MCP treated fruits showed 39.4 and 33.1N during same period. In the fruits harvested at 140 DAFB, the firmness of untreated fruit was lowered to 14.8 and 6.6N after 14 and 21 days, respectively, but those of 1-MCP treated fruit were 35.0 and 33.3N, respectively. Whereas, 1-MCP treatment delayed firmness loss only in the fruit harvested late (150 DAFB) in 'Whasan' pears. Higher soluble solids content and acidity during extended shelf-life were apparent in 1-MCP treated 'Wonhwang' pears, while those of 'Whasan' pears were little changed. 'Wonhwang' pears showed a relatively high ethylene production (maximum $0.58{\mu}l{\cdot}L^{-1}$) in the fruits harvested late than early harvested one. 'Whasan' pears showed little amount of ethylene production regardless of extended shelf-life. 1-MCP treatment to 'Wonhwang' pears decreased respiration rate following shelf-life, 42 and 50% reduction were observed at 14 days of shelf-life when compared with those of untreated ones harvested at 130 and 140 DAFB, respectively. No reduction of respiration rate by the treatment of 1-MCP was detected in 'Whasan' pears which showed considerably low respiration rate compared with 'Wonhwang' pears. Harvest time influenced the level of physiological disorders together with extension of shelf-life in both the cultivars. 1-MCP treatment completely blocked the incidence of internal browning of 'Wonhwang' pears harvested at 130 DAFB, and reduced the incidences of pithiness and core browning, while it promoted the flesh spot decay disorder regardless of harvest time. 1-MCP treatment was of little benefit for the prevention of physiological disorders in 'Whasan' pears compared with those of 'Wonhwang'.

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.

The Optimum Operating Conditions of Indented-Cylinder Length Grader to Remove Broken Rice based on Varietal Characteristics (벼 품종별 입형분리기 최적 가동조건)

  • Lee, Choon-Ki;Song, Jin;Yun, Jong-Tag;Seo, Jong-Ho;Lee, Jae-Eun;Kim, Jung-Tae;Jeong, Gun-Ho;Kim, Chung-Kon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.54 no.4
    • /
    • pp.366-374
    • /
    • 2009
  • To determine the optimum operating conditions of the indented cylinder length grader based on varietal characteristics, broken rice removal capabilities were measured on the milled rice of 41 varieties at different conditions consisted of 3 types of indented cylinders with different indent-opening diameters and 3 different collecting-angles of broken rice. The broken rice removal capabilities were swayed by the indent's opening diameter and depth as well as the angle of the collecting trough of broken rice on the point of instrument, and by the kernel length and width as well as 1000 grain weight of milled rice on the point of rice variety. When the angle of broken rice collecting-trough reached to near the horizontal center line of the indented cylinder on the direction of upward turning side, which was referred $0^{\circ}$ in this paper, the amount of rice collected in trough increased, whereas the loss of head rice also increased. Considering the removal rate of broken rice as well as loss of head rice, it was thought that the suitable angle of trough for broken rice collecting was located $5^{\circ}$ to $15^{\circ}$ depending on varietal characteristic and indent opening diameter. It was thought that 4.2 mm or more of indent opening diameter was recommendable for the rice varieties having heavier 1000 grain weight than 22.3g, as well as larger sizes than 2.9 and 5.2 mm in width and length of rice kernel, respectively; 3.8 mm for the small-sized thin kernels, and a proper diameter between 3.8 and 4.2 mm for short to middle kernels. The varieties with relatively shorter length compared to width of kernel were more difficult to separate the broken rice than the opposite ones. For effective separation of that, it seems that some specific indent shapes such as wider opening and shallow depth etc. are required. When the broken rice content were excessively high, wider diameters of indent openings than specified sizes were thought to be the better.

Effects of Active MA Mini-packaging on Shelf-life Maintenance during Marketing of Perilla Leaves (깻잎의 active MA 소포장이 유통기간 중 신선도 유지에 미치는 영향)

  • Jeong, Cheon-Soon;Um, Gi-Jeung;Park, Jong-Nam
    • Horticultural Science & Technology
    • /
    • v.28 no.6
    • /
    • pp.980-984
    • /
    • 2010
  • Research regarding respiration rate, off-flavor related material and freshness maintenance effect of active MA mini-packaging on perilla leaves has been carried in this study. Respiration rate was highly maintained at high oxygen treatments ($CO_2:O_2:N_2$=0:30:70 and 0:50:50), higher than non-treatment and low oxygen treatments (6:2:92, 0:10:90) during the storage period, and ethylene production was relatively higher. However, off-flavor related materials, acetaldehyde and ethanol production was noticeably low. Weight losses of non-treatment and low-oxygen treatment were about 1.8 and 1.4%, respectively. At the fifth day of storage there was no weight loss. Ascorbic acid content was 13.3 mg/100 g F.W. at the first day of storage. At the third day of storage non-treatment showed the lowest value of ascorbic acid, 8.8 mg/100 g F.W. Ascorbic acid content of active MA treatment gradually decreased without a striking difference as the storage day extended. Chlorophyll content was the lowest at the fifth day of storage with non-treatment, 47.5 (SPAD-502 unit) while the active MA treatment maintained high level of chlorophyll content, 53.0. Sensory evaluation (vision) showed that marketability gradually decreased but was maintained in high oxygen treatments (0:30:70 and 0:50:50), even at the fifth day of storage. Occurrence of off-flavor in non-treatment at the fifth day of storage was extremely low, 2.6; whereas high in high oxygen treatment, 3.4. Active MA packaging maintained freshness two more days at room temperature (about $27^{\circ}C$).

An Electrical Conductivity Reconstruction for Evaluating Bone Mineral Density : Simulation (골 밀도 평가를 위한 뼈의 전기 전도도 재구성: 시뮬레이션)

  • 최민주;김민찬;강관석;최흥호
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.261-268
    • /
    • 2004
  • Osteoporosis is a clinical condition in which the amount of bone tissue is reduced and the likelihood of fracture is increased. It is known that the electrical property of the bone is related to its density, and, in particular, the electrical resistance of the bone decreases as the bone loss increases. This implies that the electrical property of bone may be an useful parameter to diagnose osteoporosis, provided that it can be readily measured. The study attempted to evaluate the electrical conductivity of bone using a technique of electrical impedance tomography (EIT). It nay not be easy in general to get an EIT for the bone due to the big difference (an order of 2) of electrical properties between the bone and the surrounding soft tissue. In the present study, we took an adaptive mesh regeneration technique originally developed for the detection of two phase boundaries and modified it to be able to reconstruct the electrical conductivity inside the boundary provided that the geometry of the boundary was given. Numerical simulation was carried out for a tibia phantom, circular cylindrical phantom (radius of 40 mm) inside of which there is an ellipsoidal homeogenous tibia bone (short and long radius are 17 mm and 15 mm, respectively) surrounded by the soft tissue. The bone was located in the 15 mm above from the center of the circular cross section of the phantom. The electrical conductivity of the soft tissue was set to be 4 mS/cm and varies from 0.01 to 1 ms/cm for the bone. The simulation considered measurement errors in order to look into its effects. The simulated results showed that, if the measurement error was maintained less than 5 %, the reconstructed electrical conductivity of the bone was within 10 % errors. The accuracy increased with the electrical conductivity of the bone, as expected. This indicates that the present technique provides more accurate information for osteoporotic bones. It should be noted that tile simulation is based on a simple two phase image for the bone and the surrounding soft tissue when its anatomical information is provided. Nevertheless, the study indicates the possibility that the EIT technique may be used as a new means to detect the bone loss leading to osteoporotic fractures.

A Study on the Carbothermic Reduction and Refining of V, Ta and B Oxides by Ar/Ar-H2 Plasma (Ar/Ar-H2 플라즈마에 의한 V, Ta, B 산화물의 탄소용융환원 및 정련)

  • Chung, Yong-Sug;Park, Byung-Sam;Hong, Jin-Seok;Bae, Jung-Chan;Kim, Moon-Chul;Baik, Hong-Koo
    • Journal of Hydrogen and New Energy
    • /
    • v.7 no.1
    • /
    • pp.81-92
    • /
    • 1996
  • The Ar/Ar-$H_2$ plasma method was applied to reduce oxides and refine metals of V, Ta and B. In addition, the high temperature chemical reaction in Ar plasma and of the refining reaction in the Ar-(20%)$H_2$ plasma were analyzed. The crude V of 96wt% purity was obtained at the ratio of $C/V_{2}O_{5}=4.50$ by the Ar plasma reduction grade and the maximum reduction was obtained at $C/V_{2}O_{5}=4.50$ due to the $O_{2}$ loss from the thermal decomposition of vanadium oxide. In the Ar-(20%)$H_2$ plasma refining, the metallic V of 99.2wt% was produced at the ratio of $C/V_{2}O_{5}=4.40$. It was considered that a main refining reaction resulted from the chemical reaction between the residual carbon and residual oxygen. The metallic Ta of 99.8wt% was obtained at the ratio of $C/Ta_{2}O_{5}=5.10$ in a Ar plasma reduction and the Oz loss from the thermal decomposition of tantalum pentoxide did not take place. The deoxidation reaction was more significant than the decarburization reaction in the Ar-(20%)$H_2$ plasma refining and the metallic Ta of 99.9wt% was produced within the range of $C/Ta_{2}O_{5}$ ratio of 4.50 to 5.10. The Vickers hardness of Ta in the above mentioned range was about 220Hv due to the decrease in a residual oxygen by the deoxidation reaction. On the other hand, C is no suitable agent for the reduction of $B_{2}O_{3}$ by the Ar and Ar-$H_2$ plasma. But Fe-B-Si alloy was produced with the reduction of $B_{2}O_{3}$ in the melt when Fe, C, $B_{2}O_{3}$, and ferroboron mixtures were melted by the high frequency induction melting.

  • PDF

Comparison of Imported Wheat Flour Bread Making Properties and Korean Wheat Flour Bread Making Properties Made by Various Bread Making Methods (수입밀의 제빵 적성과 반죽법을 달리한 우리밀 제빵 적성의 비교)

  • Kim, Won-Mo;Lee, Gyu-Hee
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.3
    • /
    • pp.434-441
    • /
    • 2015
  • To develop dough methods for improving bread making properties of Korean wheat flour, straight dough methods (SDM) and dough and sponge methods (DSM) were applied. The bread making properties such as weight of bread, specific volume, baking loss, crumb color, and texture were analyzed. In comparison of flour properties between Korean wheat flour and imported wheat flour by Farinograph, Korean wheat flour showed less gluten network form ability than imported wheat flour. The dough making method affected bread quality such as weight of bread, specific volume, and baking loss. SDM had a more desirable effect on bread quality. Crumb color was lighter in bread made with Korean wheat flour compared to imported wheat flour, whereas dough making method did not affect crumb color. In consumer acceptance analysis, bread made by DSM showed higher consumer acceptance than that made by SDM. Regarding physicochemical changes during storage, bread made by SDM using Korean wheat flour showed higher chewiness, brittleness, and hardness than that made by imported wheat flour. However, bread made by DSM showed similar chewiness as bread made by SDM using imported wheat flour. The bread making properties of bread made by DSM is improved versus that of bread made with Korean wheat flour.

Rheological properties of dental resin cements during polymerization (치과용 레진 시멘트의 유변학적 성질)

  • Lee, Jae-Rim;Lee, Jai-Bong;Han, Jung-Suk;Kim, Sung-Hun;Yeo, In-Sung;Ha, Seung-Ryong;Kim, Hee-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.2
    • /
    • pp.82-89
    • /
    • 2014
  • Purpose: The purpose of this study was to observe the change of viscoelastic properties of dental resin cements during polymerization. Materials and methods: Six commercially available resin cement materials (Clearfil SA luting, Panavia F 2.0, Zirconite, Variolink N, RelyX Unicem clicker, RelyX U200) were investigated in this study. A dynamic oscillation-time sweep test was performed with AR1500 stress controlled rheometer at $32^{\circ}C$. The changes in shear storage modulus (G'), shear loss modulus (G"), loss tangent (tan ${\delta}$) and displacement were measured for twenty minutes and repeated three times for each material. The data were analyzed using one-way ANOVA and Tukey's post hoc test (${\alpha}$=0.05). Results: After mixing, all materials demonstrated an increase in G' with time, reaching the plateau in the end. RelyX U200 demonstrated the highest G' value, while RelyX Unicem (clicker type) and Variolink N demonstrated the lowest G' value at the end of experimental time. Tan ${\delta}$was maintained at some level and reached the zero at the starting point where G' began to increase. The tan ${\delta}$and displacement of the tested materials showed similar pattern in the graph within change of time. The displacement of all 6 materials approached to zero within 6 minutes. Conclusion: Compared to other resin cements used in this study, RelyX U200 maintained plastic property for a longer period of time. When it completed the curing process, RelyX U200 had the highest stiffness. It is convenient for clinicians to cement multiple units of dental prostheses simultaneously.

Association of Bone Mineral Density with the Metabolic Syndrome (건강검진 수진자들에서 골밀도와 대사증후군의 연관성)

  • Kang, Yeong-Han;Kam, Shin
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.259-266
    • /
    • 2008
  • Objective : The purpose of this study was to examine the relationship between bone mineral density (BMD) and the metabolic syndrome. Method : We conducted a cross-sectional study of 1204 adults(males: 364 females: 840) in a general hospital health promotion center. They were grouped into the normal and lower BMD group according to bone loss(osteopenia, osteoporosis), as determined by duel energy X-ray absorptiometery(DEXA). We analyzed the association between BMD and metabolic syndrome by multiple logistic regression analysis. After adjustment for age, weight, alcohol intake, smoking, regular exercise, regular intake of meals, and menopausal status, odds ratios for the prevalence of the metabolic syndrome by gender were calculated for lower BMD. Results : After adjustment for the effect of potential covariates, the prevalence of metabolic syndrome was associated with bone loss in men(p<0.001). If the odds ratio of normal group is 1.00, then that of the lower BMD group is 3.07(95% CI=1.83-5.16). The prevalence of metabolic alterations fitting the criteria of metabolic syndrome was significantly decreased in High BMI, Low HDL in men and in High BMI in women(p<0.05). Conclusions : This study shows that BMD was associated with metabolic syndrome. Further studies needed to obtain evidence concerning the association between BMD and metabolic syndrome.

  • PDF

Comparison of Pork Quality Characteristics of Different Parts from Domesticated Pig Species (국내에 보급되어 이용 가능한 돼지 품종의 부위별 육질특성 탐색)

  • Kang, Hyun-Sung;Seo, Kang-Seok;Kim, Kyung-Tai;Nam, Ki-Chang
    • Food Science of Animal Resources
    • /
    • v.31 no.6
    • /
    • pp.921-927
    • /
    • 2011
  • To compare pork quality from different pig species domesticated for Korean consumers, the meat quality characteristics of 5 different pure breeds of Landrace (L), Yorkshire (Y), Duroc (D), Berkshire (B), and Chester White (C) were determined from the 3 parts of loins, butts, and bellies. The fat content of loins was higher in breed D than in the other breeds, while that of butts and bellies was higher in breed B. The CIE color $a^*$ and $b^*$ values of the loins and butts from breed C were lower than those of the other breeds, but the color values of the belly part did not significantly differ by breed due to the high fat accumulation. The drip loss and cooking loss significantly differed depending on meat parts: breeds D and B were inferior in loins and butts but superior in bellies. The lipid oxidation of raw meat did not increase during the 7 d storage. The cooked butts of breed C had less thiobarbituric acid-reactive substances values than those of the other breeds at 7 d, and the cooked bellies of breeds D and B had less. Moreover, there were only minimal differences in fatty acid compositions by pork breed and part. From the view points of the physicochemical and organoleptic analysis of pork from different pig species, it is estimated that breed D had better meat quality in the loin part and breed B had better meat quality in the butt. The belly meat quality of breed C showed the least value. Although the meat quality of pig species differed depending on the parts and it was difficult to compare the meat quality of a part using the meat quality parameters of another part, the result of this study could provide basic information that can be used to improve the meat quality of different parts of pig species.