• Title/Summary/Keyword: center in Seoul

Search Result 11,609, Processing Time 0.044 seconds

Quality Evaluation of Mackerel Fillets Stored under Different Conditions by Hyperspectral Imaging Analysis

  • Azfar Ismail;Jiwon Ryu;Dong-Gyun Yim;Ghiseok Kim;Sung-Su Kim;Hag Ju Lee;Cheorun Jo
    • Food Science of Animal Resources
    • /
    • v.43 no.5
    • /
    • pp.840-858
    • /
    • 2023
  • This study was designed to compare the quality changes in mackerel fillets stored under different conditions by using hyperspectral imaging (HSI) techniques. Fillets packaged in vacuum were stored for six days under five different conditions: refrigerated at 4℃ (R group); iced at 5±3℃ (I group); kept at an ambient of 17±2℃ (A group); frozen at -18℃ for 24 h and thawed in a refrigerator at 4℃ for 5 h on the sampling day (FTR group); FTR thawed in tap water instead of thawing in a refrigerator (FTW group). The FTR group had the lowest total bacterial count, drip loss, 2-thiobarbituric acid reactive substances, volatile basic nitrogen, and texture profile analysis values among groups during the entire storage period (p<0.05). Scanning electron microscopy revealed that the FTR group had less damage, while the other groups had shrunken muscle tissues. HIS integrated with the partial least squares model yielded reliable and efficient results, with high R2cv values, for several quality parameters of the mackerel fillets. Overall, the FTR group, involving freezing and thawing in a refrigerator, appears to be the most favorable option for maintaining the quality of mackerel fillets, which could be practically implemented in the industry. HSI is a suitable and effective technique for determining the quality of mackerel fillets stored under different conditions.

Spinal Hemangiopericytoma Which Needed Intraoperative Embolization due to Unexpected Bleeding

  • Lee, Chang-Hyun;Kim, Ki-Jeong;Jahng, Tae-Ahn;Kim, Hyun-Jib
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.3
    • /
    • pp.253-256
    • /
    • 2013
  • Spinal intradural hemangiopericytoma is a very rare tumor and can be characterized by massive bleeding during surgeries, frequent recurrence, and metastasis. However, definite radiologic differential points of hemangiopericytoma are not known. We describe an unexpected hemangiopericytoma case with large bleeding and management of the tumor. A 21-year-old man visited complaining of progressive neck pain and tingling sensation in both hands. Magnetic resonance imaging of his spine revealed C1-2 ventral intradural mass. When the dura was opened, the intradural tumor was placed behind spinal accessary nerves. The tumor was partially exposed only after some accessary nerves had been cut. When internal debulking was performing, unexpected bleeding was noted and it was difficult to control because of narrow surgical field and hypervascularity. Intraoperative spinal angiography and embolization were performed. The tumor was completely removed after embolization. Pathological diagnosis was consistent with hemangiopericytoma. When surgeons meet a flesh-red tumor that bleeds unexpectedly during surgery, hemangiopericytoma may be considered. When feeder control is hard due to reciprocal location of spinal cord, the tumor, and feeders, intraoperative angiography and embolization may be a possible option.

Practice guidelines for managing extrahepatic biliary tract cancers

  • Hyung Sun Kim;Mee Joo Kang;Jingu Kang;Kyubo Kim;Bohyun Kim;Seong-Hun Kim;Soo Jin Kim;Yong-Il Kim;Joo Young Kim;Jin Sil Kim;Haeryoung Kim;Hyo Jung Kim;Ji Hae Nahm;Won Suk Park;Eunkyu Park;Joo Kyung Park;Jin Myung Park;Byeong Jun Song;Yong Chan Shin;Keun Soo Ahn;Sang Myung Woo;Jeong Il Yu;Changhoon Yoo;Kyoungbun Lee;Dong Ho Lee;Myung Ah Lee;Seung Eun Lee;Ik Jae Lee;Huisong Lee;Jung Ho Im;Kee-Taek Jang;Hye Young Jang;Sun-Young Jun;Hong Jae Chon;Min Kyu Jung;Yong Eun Chung;Jae Uk Chong;Eunae Cho;Eui Kyu Chie;Sae Byeol Choi;Seo-Yeon Choi;Seong Ji Choi;Joon Young Choi;Hye-Jeong Choi;Seung-Mo Hong;Ji Hyung Hong;Tae Ho Hong;Shin Hye Hwang;In Gyu Hwang;Joon Seong Park
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.28 no.2
    • /
    • pp.161-202
    • /
    • 2024
  • Backgrounds/Aims: Reported incidence of extrahepatic bile duct cancer is higher in Asians than in Western populations. Korea, in particular, is one of the countries with the highest incidence rates of extrahepatic bile duct cancer in the world. Although research and innovative therapeutic modalities for extrahepatic bile duct cancer are emerging, clinical guidelines are currently unavailable in Korea. The Korean Society of Hepato-Biliary-Pancreatic Surgery in collaboration with related societies (Korean Pancreatic and Biliary Surgery Society, Korean Society of Abdominal Radiology, Korean Society of Medical Oncology, Korean Society of Radiation Oncology, Korean Society of Pathologists, and Korean Society of Nuclear Medicine) decided to establish clinical guideline for extrahepatic bile duct cancer in June 2021. Methods: Contents of the guidelines were developed through subgroup meetings for each key question and a preliminary draft was finalized through a Clinical Guidelines Committee workshop. Results: In November 2021, the finalized draft was presented for public scrutiny during a formal hearing. Conclusions: The extrahepatic guideline committee believed that this guideline could be helpful in the treatment of patients.

Analysis of Pencycuron in Agricultural Products by Simultaneous Determination (동시 다성분 분석법에 의한 농산물 중 펜시쿠론 분석)

  • Park, Young-Hye;Han, Chang-Ho;Kim, Ae-Kyung;Shin, Jae-Min;Lee, Jae-Kyoo;Park, Sun-Hee;Yun, Eun-Sun;Kim, Mu-Sang;Chae, Young-Zoo
    • The Korean Journal of Pesticide Science
    • /
    • v.17 no.3
    • /
    • pp.162-167
    • /
    • 2013
  • An analytical method for the simultaneous determination of pencycuron in agricultural products was established by using GC-NPD. The method was validated through the guidelines of linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy and precision. The calibration curve of pencycuron was linear over the concentration range of 0.02-2 mg/kg with correlation coefficient of above 0.9999. The limits of detection and quantification were 0.005 and 0.02 mg/kg. Mean recoveries of pencycuron for each sample were 79.6-107.5% at the level of 0.02 mg/kg and 86.4-112.1% at the level of 0.2 mg/kg and 84.0- 104.9% at the level of 1 mg/kg. Relative standard deviation (RSD) in recoveries were all less than 5%. The intra- and inter-day precision (RSD) were 1.6-3.0% and 5.3-11.5%, respectively. The result of validation indicated that this method was accurate and sensitive assay.

Temperature and magnetic field dependent optical properties of superconducting $MgB_2$ thin film (초전도 $MgB_2$ 박막의 온도와 장기장의 변화에 따른 광학적 성질)

  • Jung, J. H.;Lee, H. J.;Kim, K. W.;Kim, M. W.;Noh, T. W.;Wang, Y. J.;Kang, W. N.;Jung, C. U.;Lee, Sung-Ik
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.31-35
    • /
    • 2001
  • We investigated the temperature and magnetic field dependent optical properties of a$ MgB_2$ thin film in the far-infrared region. In the superconducting state, i.e. 5 K, we obtained the values of superconducting gap $2\Delta$ ~ 5.2 meV and $2\Delta$ $_{k}$ $B/T_{c}$ ~1.8. Although the value of$ 2\Delta$$B/T_{c}$ was nearly half of the BCS value, the $2\Delta$ seemed to follow the temperature dependence of the BCS formula. Under the magnetic field (H), the superconducting state became suppressed. Interestingly, we found that the normal state area fraction abruptly increased at low field but slowly increased at high field. It did not follow the H-dependences predicted for a s-wave superconductor (i.e. a linear dependence) nor for a s-wave one (i.e. $H^{1}$2/ dependence). We discussed the complex gap nature of $MgB_2$ in comparison with two gap and anisotropic s-wave scenarios.ios.

  • PDF

A Quick and Safe Method for Fungal DNA Extraction

  • Chi, Myoung-Hwan;Park, Sook-Young;Lee, Yong-Hwan
    • The Plant Pathology Journal
    • /
    • v.25 no.1
    • /
    • pp.108-111
    • /
    • 2009
  • DNA-based studies, including cloning and genotyping, have become routine in fungal research laboratories. However, preparation of high-quality DNA from fungal tissue requires much time and labor and is often a limiting step for high-throughput experiments. We have developed a quick and safe (QS) DNA extraction method for fungi. Time efficiency and safety in the QS method were achieved by using plate-grown mycelia as the starting material, by eliminating phenol-chloroform extraction procedures, and by deploying a simple electric grinder. This QS method is applicable not only to a broad range of microbial eukaryotes, including true fungi and oomycetes, but also to lichens and plants.

Analysis of Diflubenzuron in Agricultural Commodities by Multiresidue Method (동시 다성분 분석법에 의한 농산물 중 Diflubenzuron 분석)

  • Park, Sun-Hee;Han, Chang-Ho;Kim, Ae-Kyung;Shin, Jae-Min;Lee, Jae-Kyoo;Park, Young-Hae;Kim, Ji-Min;Hwang, Lae-Hong;Chang, Min-Su;Song, Mi-Ok;Park, Ju-Sung;Yun, Eun-Sun;Kim, Mu-Sang;Jung, Kweon
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.4
    • /
    • pp.269-277
    • /
    • 2014
  • The multiclass pesticide multiresidue method for the simultaneous determination of diflubenzuron in agricultural products was conducted by using HPLC-UVD. The method was validated through the guidelines of linearity, specificity, limit of detection (LOD), limit of quantification (LOQ), accuracy and precision with pesticide-free spinach, Korean cabbage, eggplant, squash, sweet pepper, cucumber, Korean melon. The calibration curve of diflubenzuron was linear over the concentration range of 0.05-5 mg/kg with correlation coefficient of above 0.99999. The limit of detection and quantification was 0.008 and 0.02 mg/kg. Mean recoveries of diflubenzuron for each sample were 77.5-105.6%. Relative standard deviation (RSD) in recoveries were all less than 20%. The intra-day and inter-day precision (RSD) were 0.4-1.9% and 0.7-1.9%, respectively. The result of validation indicated that this method was accurate and rapid assay.

Validation of the mobile wireless digital automatic blood pressure monitor using the cuff pressure oscillometric method, for clinical use and self-management, according to international protocols

  • Yoo, Sooyoung;Baek, Hyunyoung;Doh, Kibbeum;Jeong, Jiyeoun;Ahn, Soyeon;Oh, Il-Young;Kim, Kidong
    • Biomedical Engineering Letters
    • /
    • v.8 no.4
    • /
    • pp.399-404
    • /
    • 2018
  • The purpose of this study was to evaluate the accuracy of a mobile wireless digital automatic blood pressure monitor for clinical use and mobile health (mHealth). In this study, a manual sphygmomanometer and a digital blood pressure monitor were tested in 100 participants in a repetitive and sequential manner to measure blood pressure. The guidelines for measurement used the Korea Food & Drug Administration protocol, which reflects international standards, such as the American National Standard Institution/Association for the Advancement of Medical Instrumentation SP 10: 1992 and the British Hypertension Society protocol. Measurements were generally consistent across observers according to the measured mean ${\pm}SD$, which ranged in $0.1{\pm}2.6mmHg$ for systolic blood pressure (SBP) and $0.5{\pm}2.2mmHg$ for diastolic blood pressure (DBP). For the device and the observer, the difference in average blood pressure (mean${\pm}$SD) was $2.3{\pm}4.7mmHg$ for SBP and $2.0{\pm}4.2mmHg$ for DBP. The SBP and DBP measured in this study showed accurate measurements that satisfied all criteria, including an average difference that did not exceed 5 mmHg and a standard deviation that did not exceed 8 mmHg. The mobile wireless digital blood pressure monitor has the potential for clinical use and managing one's own health.

Vehicle-related Fine Particulate Air Pollution in Seoul, Korea

  • Bae, Gwi-Nam;Lee, Seung-Bok;Park, Su-Mi
    • Asian Journal of Atmospheric Environment
    • /
    • v.1 no.1
    • /
    • pp.1-8
    • /
    • 2007
  • Vehicle exhaust is a dominant source of air pollutants in urban areas. Since people are easily exposed to vehicle exhaust particles while driving a car and/or traveling via public transportation, air pollution near traffic has been extensively studied in developed countries. In this paper, investigations on vehicle-related fine particulate air pollution at roadsides and on roads in Seoul, Korea were reviewed to understand air pollution near traffic. Comparison of $PM_{10}$ concentrations in Seoul showed that roadside air is more contaminated than urban air, implying that exposure levels near vehicular emissions are more critical to sensitive persons. Concentrations of ultrafine particles and BC (black carbon) at roadsides of Seoul fluctuate highly for short durations, responding to traffic situations. Diurnal variations of ultrafine particles and BC concentrations at roadsides seem to be affected by traffic volume, mixing layer height, and wind speed. Concentrations of ultrafine particles and BC decrease as distance from the road increases due to dilution during transport. On-road air pollution seems to be more severe than roadside air pollution in Seoul. Since nearby traffic air pollution has not been well understood in Seoul, further studies including various vehicular air pollutants and representative locations are needed.