Additive manufacturing (AM), so called 3D Printing is a new manufacturing process and is getting attraction from many industries. There are several methods of 3D printing. Among them fused deposition modeling (FDM) type is most widely used by reason of cheap maintenance, easy operation and variety of polymeric materials. Articles manufactured by 3D printing have weak deposition strength compared with conventionally manufactured products. Deposition strength of FDM type 3D printed article is highly dependent of deposition temperature. Subsequently the nozzle temperature in the FDM type 3D printing is very important and it is controlled by heat source in the 3D printer. Nozzle is connected with heat block and barrel, and heat block contains heat source. Nozzle becomes hot through heat conduction from heat source. Nozzle temperature has been predicted for various thermal boundary conditions by computer simulation and compared with experimental measurement. Nozzle temperature highly depends upon thermal conductivities of heat block and nozzle. Simulation results are good agreement with experiment.
O-Methyltransferases (OMTs), one of the ubiquitous enzymes in plants, bacteria, and humans, catalyze a methyl-transfer reaction using S-adenosylmethionine and a wide range of phenolics as a methyl donor and acceptor, respectively. Substrates for most bacterial OMTs have largely remained elusive, but recent investigation using BcOMT2, an OMT from Bacillus cereus, suggested that ortho-dihydroxyflavonoids could serve as substrates. To elucidate the functional and structural features of BcOMT2, we expressed, and purified BcOMT2, and crystallized an apoenzyme and its ternary complex in the presence of a flavonoid and S-adenosylhomocysteine. Each crystal diffracted to $1.8{\AA}$ with its space group of C2 and $P2_{1}2_{1}2_{1}$, respectively. Structural analysis of apo-BcOMT2 and its ternary complex will provide the structural basis of methyl transfer onto (iso)flavonoids in a regiospecific manner.
Jeon, Jin Sue;Lee, Sang Hyung;Son, Young-Je;Chung, Young Seob
Journal of Korean Neurosurgical Society
/
v.53
no.3
/
pp.194-196
/
2013
Isolated abducens nerve paresis related to ruptured vertebral artery (VA) aneurysm is rare. It usually occurs bilaterally or ipsilaterally to the pathologic lesions. We report the case of a contralateral sixth nerve palsy following ruptured dissecting VA aneurysm. A 38-year-old man was admitted for the evaluation of a 6-day history of headache. Abnormalities were not seen on initial computed tomography (CT). On admission, the patient was alert and no signs reflecting neurologic deficits were noted. Time of flight magnetic resonance angiography revealed a fusiform dilatation of the right VA involving origin of the posterior inferior cerebellar artery. The patient suddenly suffered from severe headache with diplopia the day before the scheduled cerebral angiography. Neurologic examination disclosed nuchal rigidity and isolated left abducens nerve palsy. Emergent CT scan showed high density in the basal and prepontine cistern compatible with ruptured aneurismal hemorrhage. Right vertebral angiography illustrated a right VA dissecting aneurysm with prominent displaced vertebrobasilar artery to inferiorly on left side. Double-stent placement was conducted for the treatment of ruptured dissecting VA aneurysm. No diffusion restriction signals were observed in follow-up magnetic resonance imaging of the brain stem. Eleven weeks later, full recovery of left sixth nerve palsy was documented photographically. In conclusion, isolated contralateral abducens nerve palsy associated with ruptured VA aneurysm may develop due to direct nerve compression by displaced verterobasilar artery triggered by primary thick clot in the prepontine cistern.
Kim, Hyungjin;Cho, Seongjae;Sun, Min-Chul;Park, Jungjin;Hwang, Sungmin;Park, Byung-Gook
JSTS:Journal of Semiconductor Technology and Science
/
v.16
no.5
/
pp.657-663
/
2016
In this work, a novel silicon (Si) based floating body synaptic transistor (SFST) is studied to mimic the transition from short-term memory to long-term one in the biological system. The structure of the proposed SFST is based on an n-type metal-oxide-semiconductor field-effect transistor (MOSFET) with floating body and charge storage layer which provide the functions of short- and long-term memories, respectively. It has very similar characteristics with those of the biological memory system in the sense that the transition between short- and long-term memories is performed by the repetitive learning. Spike timing-dependent plasticity (STDP) characteristics are closely investigated for the SFST device. It has been found from the simulation results that the connectivity between pre- and post-synaptic neurons has strong dependence on the relative spike timing among electrical signals. In addition, the neuromorphic system having direct connection between the SFST devices and neuron circuits are designed.
Phongsaly Province, located in the northernmost area of Lao PDR, was previously suggested to be endemic for the liver fluke Opisthorchis viverrini infection. To confirm, or rule out, this suggestion, the Phonxay village in the Khoua District, Phongsaly Province, was selected for a survey. Ten volunteers (8 men and 2 women aged 31-57 years) who consumed raw freshwater fish and had gastrointestinal troubles were treated with a single dose of praziquantel (40 mg/kg) and pyrantel pamoate (10 mglkg) and purged with magnesium sulfate to recover any worm parasites. Eight of the 10 volunteers expelled 1 or more species of trematodes, nematodes, or cestodes (worm positive rate; 80%). The worms were morphologically identified as H. taichui (861 worms from 8 people), H. yokogawai (59 from 6 people), Phaneropsolus bonnei (1 from 1 person), Trichostrongylus sp. (2 from 2 people), Ascaris lumbricoides (2 from 1 person), Enterobius vermicularis (11 from 3 people), and Taenia saginata (1 strobila with scolex from 1 person). The results indicate that the mountainous area of Phongsaly Province, Lao PDR, is not endemic for the liver fluke but endemic for intestinal flukes, in particular, Haplorchis taichuiand H. yokogawai.
Seo, Chan-Won;Kang, Shin-Ho;Shin, Yong-Kook;Yoo, Byoungseung
Food Science of Animal Resources
/
v.38
no.3
/
pp.476-486
/
2018
In this study, the droplet size distribution, rheological properties, and stability of dairy cream-based emulsions homogenized with different sucrose fatty acid ester (SFAE, a non-ionic small-molecule emulsifier) concentrations (0.08%, 0.16%, and 0.24% w/w) at different homogenization pressures (10 MPa and 20 MPa) were examined. Homogenization at a high pressure resulted in a smaller droplet size and narrower droplet size distribution. The D[4,3] (volume-weighted mean) and D[3,2] (surface-weighted mean) values of the emulsions decreased with an increase in the SFAE concentration. The flow properties of the emulsions homogenized with SFAE showed shear-thinning (n=0.21-0.46) behavior. The apparent viscosity (${\eta}_{a,10}$) and consistency index (K) of the homogenized emulsions were lower than those of the control sample that is non-homogenized and without SFAE, and decreased with an increase in SFAE concentration. The storage modulus (G') and loss modulus (G") of all emulsions homogenized with SFAE were also lower than those of the control sample. The stability of all emulsions with SFAE did not show any significant change for 30 d at $5^{\circ}C$. However, the emulsions stored at $40^{\circ}C$ were unstable over the storage period. Therefore, the addition of SFAE enhanced the stability of dairy cream emulsions during storage at refrigeration temperature ($5^{\circ}C$).
Kim, Hae-Young;Chung, Hyun-Suk;Jeon, Byoung-Hak;Shin, Mi-Hyeon
Journal of Home Health Care Nursing
/
v.17
no.2
/
pp.135-143
/
2010
Purpose: The study analyzed continuing educational needs with the aim of developing continuing education program for home healthcare nurse specialists. Methods: A convenience sample of 101 home healthcare nurse specialists affiliated with 89 home health care agencies in Seoul, Busan, Dae-gu, Inchon, Jeonnam, Keongnam was used. Data was collected with a self-report questionnaire from May 10-31, 2010, and analyzed with descriptive statistics using SAS 9.13 program. Results: Of the participants, 88.1% reported that continuing education was necessary and 58.2% reported that the education was needed for peak job performance. The participants also reported that it would be proper if continuing education is given on a Saturday(56.4%) by home healthcare institute(49.5%) or homecare nurses association (38.6%) for 1-3 months(56.4%). The participants scored more than 3.0 in the current performance at six of the seven home healthcare nurse specialist roles, and scored more than 3.5 in the necessity of continuing education for seven roles in 47 jobs. Conclusion: Various programs for continuing education have to be developed and need to focused on the jobs needed for home healthcare nurse specialist and the most frequent disease. For this purpose, every home healthcare organization has to select their unique area and develop their own educational program. Furthemore, home healthcare nurses association has to build an education operating system that incorporates all program aspects.
Jung, Jae-Yeon;Ku, Ponjun;Kim, Do Hyung;Kwon, Min-Jae;Kang, Sungwook;Choi, Jeong-Yoon;Lee, Joo-Young
Fashion & Textile Research Journal
/
v.21
no.5
/
pp.606-617
/
2019
The present study newly developed a firefighters' protective jacket and pants using a Nomex honeycomb structured layer (HPC) in cases of being exposed to flashover or flameover. This study evaluated the protective and comfort functions of an HPC compared to the current KFI firefighters' protective clothing (FPC). The results are as follows. First, thermal protective performance (TPP) of fabric layers was 2.75 times greater for HPC than FPC at $125kW/m^2$. Second, the predicted second and third degree burn areas were smaller for HPC than FPC when using a flame manikin. Third, thermal insulation using a thermal manikin was 0.2 clo greater for HPC than FPC. Fourth, there were no marked differences in maximal performance, mobility, and microclimate temperature/humidity between FPC and HPC through human wear trials. The thermal insulation of HPC was higher than that of FPC; however, any negative effect of HPC thermal insulation on the comfort functions for firefighters was not found. In conclusion, the newly-developed HPC provided more protection in reducing burn injuries from $125kW/m^2$, while no negative impact on maximal performance, mobility and thermal comfort functions of firefighters, which is appropriate for quick-evasive tactics at the flashover, flameover or back draft fires.
Lim, Gu;Im, Myungshin;Kim, Jisu;Lee, Jeong Hwan;Choi, Changsu;Ehgamberdiev, S.;Burkhonov, O.;Mirzaqulov, D.
The Bulletin of The Korean Astronomical Society
/
v.44
no.1
/
pp.75.2-75.2
/
2019
Low surface brightness (LSB) dwarf galaxies hold a key to resolve the small-scale problems of Lambda Cold Dark Matter (LCDM) paradigm such as missing satellites problem. Many recent studies found LSB dwarf galaxies around massive galaxies beyond Local Group up to 10Mpc. Motivated by this, we can increase the number of them by searching for LSB dwarf galaxies around galaxies up to 40Mpc. We use stacked deep (${\mu}_R{\sim}26.2mag\;arcsec^{-2}$) optical B, R-band images taken from Maidanak 1.5m telescope, one of facilities of Intensive Monitoring Survey of Nearby Galaxies (IMSNG) which monitored nearby galaxies in a day cadence from 2014 to 2016. Extended LSB sources in ambient regions of 16 nearby galaxies are selected using central surface brightness and total R magnitude criteria. After that, 24 LSB dwarf candidates are selected with visual inspection. To identify if the candidates are satellites or not, we are trying to compare the number density of LSB dwarf candidates around massive galaxies with those in Canada-France-Hawaii-Telescope Legacy Survey (CFHTLS) wide fields which have no dominant massive galaxies for control sample.
Journal of The Korean Society of Agricultural Engineers
/
v.65
no.1
/
pp.41-49
/
2023
To utilize the hydraulic and hydrological models when simulating floods in agricultural watersheds, it is necessary to consider agricultural reservoirs, farmland, and farmland drainage system, which are characteristics of agricultural watersheds. However, most of them are developed individually by different researchers, also, each model has a different simulation scope, so it is hard to use them integrally. As a result, there is a need to link each hydraulic and hydrological model. Therefore, this study established an integrated flood simulation system for the comprehensive flood simulation of agricultural reservoir watersheds. The system can be applied easily to various watersheds because historical weather data and the SSP (Shared Socio-economic Pathways) climate change scenario database of ninety weather stations were built-in. Individual hydraulic and hydrological models were coded and coupled through Python. The system consists of multiplicative random cascade model, Clark unit hydrograph model, frequency analysis model, HEC-5 (Hydrologic Engineering Center-5), HEC-RAS (Hydrologic Engineering Center-River Analysis System), and farmland drainage simulation model. In the case of external models with limitations in conceptualization, such as HEC-5 and HEC-RAS, the python interpreter approaches the operating system and gives commands to run the models. All models except two are built based on the logical concept.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.