• 제목/요약/키워드: cement brick

검색결과 79건 처리시간 0.026초

중량벽체의 차음특성에 관한 실험적 연구 (An Experimental Study on the Sound Insulation Characteristics of Heavyweight Walls)

  • 김선우;이태강;송민정
    • 소음진동
    • /
    • 제8권6호
    • /
    • pp.1078-1085
    • /
    • 1998
  • This study is carried out to investigate the characteristics of sound insulation performances for masonry walls. PC walls and ALC walls. For these purposes. 17 types of masonry walls were selected and tested in accordance with KS F 2808 at reverberation room The sound insulation performance of 8" cement block walls are graded with D-45 ∼ D-55 which are to be evaluated very favorable grade. 4" cement block walls are D-30 ∼ D-40. 1 B cement brick walls are D-40∼D-50 favorable grade. 0.5 B brick walls are D-30∼D-45. 150 mm PC wall is D-50. and ALC walls(150 mm, 200 mm) are D-30∼D-45.

  • PDF

내구성증진용 혼화제(DIA) 및 부순 잔골재의 복합 치환이 순환잔골재를 사용한 고로슬래그 벽돌의 특성에 미치는 영향 (Effects of Crushed Fine Aggregate and Durability Improvement Agent (DIA) on Blast Furnace Slag-Based Brick)

  • 박경택;손호정;김대건;김복규;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.225-227
    • /
    • 2011
  • This study investigates the effect of crushed fine aggregate and chemical admixture (durability improvement agent, named DIA) on blast furnace slag-based brick. The control brick was made with recycled fine aggregate of 100% and, no cement was used. Test results showed that all specimens developed similar strength, except for the specimen without partial replacement of crushed fine aggregate at 3 days. However, it is interesting to note that this specimen without crushed fine aggregate resulted in the highest strength at 7 days. In addition, the DIA had a major effect on the absorption ratio of brick specimens. For the brick specimens with partial replacement of crushed fine aggregate with 10%, the addition of DIA with only 1% was enough to satisfy the code regulated by KS F 4004.

  • PDF

외부치장적벽돌 벽체에 대한 콘크리트 보강브라켓의 보강효과에 관한 연구 (A Study on the Strengthening effect of Concrete Reinforcement Bracket on the External Clay Brick Wall)

  • 김선우;김양중
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.117-118
    • /
    • 2020
  • The masonry structure is constructed by cement mortar binding material of brick objects and uses reinforced hardware (connected hardware or wall tie) together when building. However, over time, the corrosion of reinforced steel and the deterioration of joint mortar as well as bricks cause the risk of collapse. In particular, when the externally decorated brick wall is installed on the concrete girder for each floor, the angle bracket is not constructed or corroded, the full-layer weight load is applied to the wall of 0.5B, which is an example of full-scale or collapse. The purpose of this study is to provide numerical information on the reinforcement design by experimentally studying the structural performance of concrete reinforcement brackets that reinforce the vertical load of the exterior wall.

  • PDF

농촌주택 개량을 위한 난방 효율 시험 (The Experiment on The Efficiency of Heating System for Improving Farm Houses)

  • 이회만;최예환
    • 한국농공학회지
    • /
    • 제16권2호
    • /
    • pp.3395-3409
    • /
    • 1974
  • The purpose of this study is to test and compare the efficiency of heating-system for materials and construction of the wall, ceiling and window in soil brick house, cement house and boulder house respectively, in order to construct ideal farm houses in rural area. The results obtained were as follows: 1. In heat conservation due to construction of walls the thermal efficiency of cement brick house was equivalent to 66.3% of that of soil brick house, and boulder house 60.3% 2. In the case of ceiling, the thermal efficiency of paper ceiling was amounted to 84.2% of that of the composite ceiling (thickness 6mm veneer+thickness. l0m chaffs), and the common ceiling putting on soil above the ceiling, 76% of the composite while the efficiency of the ceiling putting on chaffs above them was 15.8% higher than that of the paper. 3. In the case of improving the window, the double type was 12% higher than. the efficiency of single type. 4. The warming velocity of conventional house was slower but the velocity of radiation was quicker than that of experimental one. It was thought to be due to unscietific constructions of the room bottom, fire inlet and chimney, 5. The temperature gradient line was not dependad upon the amount of throwing into fuel in the rural farm house. 6. It was concluded that the final thermal efficiency of the conventional farm house was 10.6% lower than that of experimental farm house.

  • PDF

X-Ray Diffraction과 X-Ray Fluorescence를 이용한 시멘트 비교 분석 (The analytical application for cement using X-Ray diffraction and X-Ray fluorescence spectrometer)

  • 정지은;장유림;김기욱;허상철;민지숙
    • 분석과학
    • /
    • 제26권5호
    • /
    • pp.340-351
    • /
    • 2013
  • The chemical element and structural characterization of different types of cements and its brick stones are been investigated under forensic aspects using X-ray florescence (XRF) and X-ray diffraction (XRD) spectrometer. The XRF provides rapid compositional data for controlling almost all stages of raw materials, clinker and cement. The decisive advantage of XRD methods is based on the unique character of the diffraction patterns of crystalline substances, the ability to distinguish between elements and their oxides, and the possibility to identify chemical compounds, polymeric forms, and mixed crystals by non-destructive examination. Therefore, combination of these examinations is useful and able to apply for the forensic analysis in comparison of cements and brick stones. There are more study remained to determine the viability of method for forensic analysis of brick stones and the limits of the discrimination that can be achieved.

친환경 황토벽체의 차음성능 평가에 관한 연구 (The sound insulation performance of eco-friendly loess brick wall)

  • 이태강;김율;송국곤;김선우
    • KIEAE Journal
    • /
    • 제9권6호
    • /
    • pp.13-18
    • /
    • 2009
  • Korean traditional houses have been developed in harmony with natural environment and comfortable indoor condition by using the natural resources including building layout, space composition and materials. Originally Korea traditional architectures have used wood lintel constructions and loess walls through the many years. Theses loess have many strength such as highly heat capacity, controling of humidity, a deodorant than any other materials. Nowaday it is recommended to use exterior and interior walls in loess wall to meet the eco-friendly materials to improve our residental environmental. Thus this study aims to research the sound insulation performance of traditional loess brick wall varied with thickness, thermal insulation materials and cavity wall. The sound insulation performance of these loess walls are compared with other masonry wall's and sound insulation performance of th walls were tested in anechoic laboratory to measure the sound transmission loss of these walls. The loess brick wall with 75mm thickness of cavity is shown the sound insulation performance with Rw 57 which is nearly same performances of 1B brick wall and cement 8' block wall, The improving effect of insulation materials is shown in the high frequency bandwidth. Especially, there is improving as much as 11 dB using the extruded poly stylene form(75mm) and poly ethylene film(0.7mm).

Effect of pozzolans on mechanical behavior of recycled refractory brick concrete in fire

  • Nematzadeh, Mahdi;Baradaran-Nasiri, Ardalan;Hosseini, Mehdi
    • Structural Engineering and Mechanics
    • /
    • 제72권3호
    • /
    • pp.339-354
    • /
    • 2019
  • Reusing building materials and concrete of old buildings can be a promising strategy for sustained development. In buildings, the performance of materials under elevated temperatures is of particular interest for determining fire resistance. In this study, the effect of pozzolan and aggregate type on properties of concrete exposed to fire was investigated. In doing so, nanosilica with cement-replacement levels of 0, 2, and 4% as well as silica fume and ultrafine fly ash with cement-replacement levels of 0, 7.5, and 15% were used to study effect of pozzolan type, and recycled refractory brick (RRB) fine aggregate replacing natural fine aggregate by 0 and 100% was utilized to explore effect of aggregate type. A total of 126 cubic concrete specimens were manufactured and then investigated in terms of compressive strength, ultrasonic pulse velocity, and weight loss at $23^{\circ}C$ and immediately after exposure to 400 and $800^{\circ}C$. Results show that replacing 100% of natural fine aggregate with recycled refectory brick fine aggregate in the concretes exposed to heat was desirable, in that it led to a mean compressive strength increase of above 25% at $800^{\circ}C$. In general, among the pozzolans used here, silica fume demonstrated the best performance in terms of retaining the compressive strength of heated concretes. The higher replacement level of silica fume and ultrafine fly ash pozzolans in the mixes containing RRB fine aggregate led to a greater weight loss rate, while the higher replacement level of nanosilica reduced the weight loss rate.

아크릴 반구를 이용한 밀폐조건에 따른 재료별 열 이동특성 분석(II): 건축구조재 종류에 따른 비교 (Analysis of Heat Transfer Characteristics by Material Based on Closed Conditions Using Acrylic Hemispheres (II): Comparison by Type of Building Structural Materials)

  • YANG, Seung Min;KWON, Jun Hyuck;KIM, Phil Lip;KANG, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • 제48권5호
    • /
    • pp.710-721
    • /
    • 2020
  • 본 연구에서는 시멘트, 벽돌, 목재를 이용한 건축모형을 이용하여 직경 900 mm의 밀폐된 환경 속에서 3일간 온도와 상대습도 측정을 통하여 건축소재의 종류에 따른 실내 온도 환경에 미치는 영향과 열 이동 특성에 대해서 비교분석하였다. 건축모형 내부에 설치된 물은 실내에 있는 사람을 나타냈으며 사람에게 어떤 영향을 미치는지 평가하고자 사용되었다. 목조 건축모형은 시멘트, 벽돌 건축물 보다 보온성이 높아 열 손실이 가장 낮은 것으로 나타났다. 각각의 건축 모형의 열적 쾌적성은 온도와 상대습도를 이용하여 산출하였으며 목조 건축 모형은 시멘트, 벽돌 건축 모형보다 더 쾌적한 환경을 조성하는 결과를 도출하였다.

황토와 플라이 애시를 혼입한 시멘트 모르타르 벽돌의 물리 · 역학적 특성 (Physical and Mechanical Properties of Cement Mortar Brick with Loess and Fly Ash)

  • 임성수;성찬용
    • 한국농공학회논문집
    • /
    • 제46권3호
    • /
    • pp.57-63
    • /
    • 2004
  • This study was performed to evaluate the engineering properties of cement mortar brick with loess and fly ash. The unit weight was in the range of $2,068{\sim}2,137\;kgf/m^{3}$ and $1,899{\sim}2,045\;kgf/m^{3}$ in water and dry curing, respectively It was decreased with increasing the loess content. The absorption ratio was in the range of $5.2{\sim}13.1%$ and $8.5{\sim}13.2%$ in water and dry curing, respectively. The compressive strength was decreased with increasing the loess content. The compressive strength of the 193 $kgf/m^{2}$ in water and 188 $kgf/m^{2}$ in dry curing at the curing age 28 days of the binder volume ratio 35% was exceeded in 163 $kgf/m^{2}$ of standard compressive strength about cement bricks. The carbonation depth was in the range of $0.9{\sim}1.4$ mm, $1.2{\sim}3.6$ mm, $1.4{\sim}6.7$ mm and $2.4{\sim}12.5$ mm in dry curing of curing age 14days, 28days, 90days and 360days, respectively.

The effect of mortar type and joint thickness on mechanical properties of conventional masonry walls

  • Zengin, Basak;Toydemir, Burak;Ulukaya, Serhan;Oktay, Didem;Yuzer, Nabi;Kocak, Ali
    • Structural Engineering and Mechanics
    • /
    • 제67권6호
    • /
    • pp.579-585
    • /
    • 2018
  • Masonry walls are of a complex (anisotropic) structure in terms of their mechanical properties. The mechanical properties of the walls are affected by the properties of the materials used in wall construction, joint thickness and the type of masonry bond. The carried-out studies, particularly in the seismic zones, have revealed that the most of the conventional masonry walls were constructed without considering any engineering approach. Along with that, large-scale damages were detected on such structural elements after major earthquake(s), and such damages were commonly occurred at the brick-joint interfaces. The aim of this study was to investigate the effect of joint thickness and also type of mortar on the mechanical behavior of the masonry walls. For this aim, the brick masonry walls were constructed through examination of both the literature and the conventional masonry walls. In the construction process, a single-type of brick was combined with two different types of mortar: cement mortar and hydraulic lime mortar. Three different joint thicknesses were used for each mortar type; thus, a total of six masonry walls were constructed in the laboratory. The mechanical properties of brick and mortars, and also of the constructed walls were determined. As a conclusion, it can be stated that the failure mechanism of the brick masonry walls differed due to the mechanical properties of the mortars. The use of bed joint thickness not less than 20 mm is recommended in construction of conventional masonry walls in order to maintain the act of brick in conjunction with mortar under load.