• Title/Summary/Keyword: cement binder

Search Result 625, Processing Time 0.027 seconds

The Characteristics of the Strength Development and Chloride Attack Resistance on the Concrete using High Early Strength Cement by Steam Curing Temperature Condition (증기양생 온도조건에 따른 조강시멘트 콘크리트의 강도발현특성 및 내염특성)

  • Lee Woong Jong;Lee Won Am;Um Tae Sun;Lee Jong Ryul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.599-602
    • /
    • 2005
  • In this research, the characteristics of the strength development and chloride attack resistance on the concrete using high early strength cement by steam curing temperature condition were studied. As a result, It is observed that the early strength(16hr) is increasing and the strength of 28 days is decreasing, according as the rising of the steam curing temperature without the kinds of base cement(OPC and high early strength cement). On the other hand, it is observed that the more the contents of the unit binder(base cement + GGBF) is abundant, the more the steam curing temperature can be reduced in case of the high early strength. Also, the chloride attack resistance is improved according as the amount of GGBF is increased with the kinds of base cement(OPC and high early strength cement).

  • PDF

Development of Water-repellent Cement Mortar by using Silane Enriched with Nanomaterials

  • lee, Han seung;Park, Dong-jin;Lee, Yunsu;Karthick, Subbiah
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.193-194
    • /
    • 2018
  • Tn this present study, the superhydrophobic surface was developed on the cement mortar surface by using water repellent materials. For better superhydropohicity, it was developed by using silane as binder and which was enriched with filler materials of SiO2 and TiO2 nanomaterials. Those nanomaterials enriched with silanes were admixed in cement mortar during casting time and another was coated on the cement mortar surface. The water repellent properties of spray coated and admixed cement mortars were evaluated by measuring the contact angle which was compared with normal cement mortar.

  • PDF

기술연구 - Clinker free 콘크리트의 기초성상에 관한 연구

  • Lee, Jong-Yeol
    • Cement
    • /
    • s.192
    • /
    • pp.39-47
    • /
    • 2011
  • 최근 온실가스 감축과 기후변화 그리고 녹색성장에 대한 관심증대와 더불어 시멘트 분야의 연구 생산분야는 천연자원 사용량을 줄이고, 소성공정을 도입하지 않은 새로운 개념의 무기바인더가 다시 고개를 들고 있다. 다른 용어로는 비소성, 무시멘트 등으로 표현되기도 하는데, 광의의 개념으로 보면 알칼리 활성화제를 사용한 비소성 무기결합재인 지오폴리머가 바로 그것이다. 지오폴리머 결합재는 1957년 우크라이나의 토목공학회에서 개발한 알칼리 활성 슬래그시멘트에 기원을 두고 있고, 1970년대 말 프랑스의 다비도비치에 의해 지오폴리머라는 용어가 처음 사용되기 시작했다. 알칼리 활성 무기결합재(Alkali-activated inorganic binder)의 정의이다. Alkali-activated inorganic binder는 원래는 결합능력이 없던 재료에 대해서 Alkali-activating 용액을 첨가했을 때, 시멘트처럼 결합능력을 가지게 되는 모든 종류의 결합시스템을 말한다. 국내에도 이미 2000년 초부터 지오폴리머의 개념을 도입한 제품이 상업화되어 오랫동안 품질검증을 거쳐 안정성이 확인되고 있다. 최근에 다시 전남대가 그 동안의 연구성과를 발 빠르게 중소기업에 기술 이전하여 소위 무시멘트 시대에 진입하는 분위기이다. 지난 9월 동아에스텍(주)과 조인트벤처 설립을 위해 손을 잡았고, 사업화가 곧 진행될 것으로 보인다. 이를 계기로 국내에도 무시멘트회사가 본격적으로 등장하게 된 것이다. 따라서 본 고는 무시멘트의 개념을 잘 표현한 문헌으로 일본콘크리트공학 연차논문집, 2010년 1월호를 번역 요약 발췌한 것이다.

  • PDF

Optimum Mix Proportions of Latex Modified Repair Mortar for Agricultural Underwater Concrete Structure (수중에 노출된 농업용 콘크리트 구조물 보수용 라텍스개질 모르타르의 적정 배합비 도출)

  • Won, Jong-Pil;Lee, Jae-Young;Park, Chan-Gi;Lee, Sang-Woo;Kim, Wan-Young
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.3
    • /
    • pp.43-50
    • /
    • 2007
  • The purpose of this study was to determine the optimum mix proportion of latex modified mortar for agricultural underwater concrete structures repair. The experimental variables included a latex and antiwashout admixture amount, binder-sand ratio, water-binder ratio. This study were evaluated a repair performance and environment effect of latex modified repair mortar for agricultural underwater concrete structures. The pH test was conducted to evaluated the environmental effect and the flow test was peformed to evaluated the workability. Also, compressive, flexural and bond tests were conducted. Test results show that the optimum mix proportion of latex modified repair mortar for agricultural underwater concrete structures, was achieved by 1:1.5 binder-sand ratio, 5% latex ratio (weight of binder), 1.3% antiwashout admixture ratio (weight of binder), 0.33 water-binder ratio and 10% silica lune replacement ratio (weight of cement). The environmental effect and repair performance of optimum mix proportion satisfied all target performance.

Investigation of the Effects of CNT Dosages on the Hydration and Heating Properties of Cement Composites with Low Water-to-binder Ratio (낮은 물-바인더 비를 갖는 시멘트 복합체의 CNT 첨가량에 따른 수화특성 및 발열특성)

  • Oh, Sungwoo;Jung, Sang-hwa;Chung, Wonseok;Choi, Young Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.182-188
    • /
    • 2018
  • Recently, various researches on the utilization of carbon nanotube(CNT) with superior electrical conductivity and large surface areas into concrete have been actively conducted. Thus, mechanical and thermal properties of cement-flyash composites were evaluated concerning the CNT replacements. Based on the low binder-to-water ratio, the cement composites were produced with 0.2 % and 0.5 % of CNT solids. The compressive strengths with various ages, isothermal calorimetry measurement, SEM analysis, thermal conductivity of cement composites and thermal gravimetry analysis were implemented. As the amount of CNT addition was increased, the thermal conductivity of cement composites were also increased. Also, there was no significant mechanical property differences between mixtures with and without CNTs.

Drying Shrinkage of High-Fluidity Polymer-Modified Paste (고유동 폴리머 시멘트 페이스트의 건조수축)

  • Joo, Myung-Ki;Lee, Youn-Su;Yeon, Kyu-Seok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.929-932
    • /
    • 2006
  • The effects of polymer-binder ratio, antifoamer content and shrinkage-reducing agent content on the setting time and drying shrinkage of high-fluidity polymer-modified pastes are examined. As a result, the setting time of the high-fluidity polymer-modified pastes tends to delayed with increasing polymer-binder ratio. Irrespective of the antifoamer content, the drying shrinkage of the high-fluidity polymer-modified pastes tend to decrease with increasing polymer-cement ratio and shrinkage-reducing agent content.

  • PDF

A Study on the Determination of mix Proportion of Water-Permeable Concretes for Site Application (현장적용 투수성 콘크리트의 배합조건 결정에 관한 실험적 연구)

  • 김봉찬;은재기;김완기;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.130-135
    • /
    • 2000
  • The purpose of this study is to examine the physical properties of water-permeable concretes. The water-permeable concrete with cement-aggregate ratios of 1:3.5 to 1:6.0 and two type of coarse aggregate size of 8~13 and 13~18mm used OPC(ordinary portland cement) as a binder and superplasticizer are prepared, and then tested for flexural strength, compressive strength, compressive strength, continuous void percentage and coefficient of water permeability. It is concluded from the test result that the superior flexural and compressive strengths, coefficient of water permeability and continuous void percentage of water-permeable concretes that use OPC were obtained at cement-aggregate ratios of 1:3.2, 1:6.0 respectively, The water-permeable concretes with coarse aggregate of 8~13 and 13~18mm size used OPC as a binder havinga flexural strength of 24.81~45.56kgf/$\textrm{cm}^2$, 21.99~40.62kgf/$\textrm{cm}^2$, a compressive stength of 93.63~ 242kgf/$\textrm{cm}^2$, 114.8~191.7.kgf/$\textrm{cm}^2$, a coefficient of permeability of 0.59~1.85kgf/$\textrm{cm}^2$, 0.73~ 2.25kgf/$\textrm{cm}^2$, and a continuos void percentage of 16.6~26.32%, 13.52~24.35% respectively during 28 curing days.

  • PDF

Effect of Hydration Heat and Drying Shrinkage of Mass Concrete Using Hwangtoh Binder (황토결합재를 이용한 매스콘크리트의 수화열과 건조수축 효과)

  • Kang, Sung-Soo;Lee, Seong-Lo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.649-652
    • /
    • 2008
  • In this paper, the applicability of hwangtoh, as an alternative of cement paste, is investigated for the solution of internal heat and shrinkage caused by the hydration of cement paste. Several small-sized specimens of hwangtoh and ordinary portland concrete(OPC) were compared as to compressive strength, heat of hydration, and shrinkage strain. Moreover, the applicability of mass structure was reviewed through the test of large-size specimens. The 28-day compressive strength of hwangtoh concrete(HBC), ranged 18 to 33 Mpa, can reach that of ordinary portland concrete. Not only the maximin internal temperature of HBC was read about 1/4 of OPC as it is cured, but also its drying shrinkage decreased as lower as 50% of OPC starting from 60 days. Therefore, hwangtoh binder is more favorable than cement one in the view of hydration heat and shrinkage under the construction of mass structures.

  • PDF

Initiation and propagation of a crack in the orthopedic cement of a THR using XFEM

  • Gasmi, Bachir;Abderrahmene, Sahli;Smail, Benbarek;Benaoumeur, Aour
    • Advances in Computational Design
    • /
    • v.4 no.3
    • /
    • pp.295-305
    • /
    • 2019
  • The sealing cement of total hip arthroplasty is the most widely used binder in orthopedic surgery for anchoring implants to their recipient bones. Nevertheless, this latter remains a fragile material with weak mechanical properties. Inside this material cracks initiate from cavities. These cracks propagate under the effect of fatigue and lead to the failure of this binder and consequently the loosening of the prosthesis. In this context, this work consists to predict the position of cracks initiation and their propagations path using the Extended Finite Element Method (XFEM). The results show that cracks can only be initiated from a sharp edges of an ellipsoidal cavity which the ratio of the minor axis over the major axis is equal to 0.1. A maximum crack length of 19 ?m found for a cavity situated in the proximal zone position under a static loading. All cracks propagate in same(almost) way regardless of the cavity(site of initiation) position and its inclination in the proximal zone.