• 제목/요약/키워드: cell impedance

검색결과 529건 처리시간 0.027초

Selection Criteria for Supercapacitors Based on Performance Evaluations

  • Kim, Sang-Hyun;Choi, Woo-Jin
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.223-231
    • /
    • 2012
  • In this paper, criteria for better selection of a supercapacitor through EIS (Electrochemical Impedance Spectroscopy) experiments are presented. The performance characteristics of a supercapacitor are thoroughly analyzed in terms of losses and available energy to select the optimal product. The validity of the proposed criteria is demonstrated through the computer simulations and experiments on a fuel cell vehicle using a supercapacitor module with the FTP-72 urban dynamometer driving schedule.

Long-term Testing and Analysis of a ScSZ/LaSrCuFe Cell

  • Wackerl, Jurgen;Peck, Dong-Hyun;Markus, Torsten
    • 한국세라믹학회지
    • /
    • 제45권12호
    • /
    • pp.788-795
    • /
    • 2008
  • An electrolyte supported SOFC cell was tested at $800^{\circ}C$ in air for 3600 h with an applied current density of $200\;mA/cm^2$ to examine possible cathode degradation issues. A scandium- stabilized zirconia (ScSZ) with additional manganese doping (ScSZ: Mn) was used as electrolyte. A strontium and copper-doped lanthanum ferrite (LaSrCuFe) and platinum were used as cathode and quasi-anode material, respectively. The DC resistance was logged over the complete testing period. Additionally, impedance spectroscopy was used from time to time to track changes of the cell in-situ. Post-test analysis of the cell using methods like scanning electron microscopy imaging and other electrochemical testing methods allow the identification of different degradation sources. The results indicate a promising combination of electrolyte and cathode material in terms of chemical compatibility and electrical performance.

세포 전기 융합 감지 장치에 관한 연구 (Development of System For Cell Fusion Detection)

  • 권기진;김민수;박세광
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1336-1338
    • /
    • 1994
  • Cell fusion device is an artificial equipment which fuses electrically two types of cells fed from the respective micropump to the fusion chamber by electric pulses. In this case, the detective sensor of flowing cell, along with passage, is required to control the time of pulses applied to cell and the injection of cells which are fed from inlet to micropump. There are two methods of detection of flowing cell; optical, impedance method. The difference of output for optical sensor is about 426mV for 805nm wavelength. about 37mV for 665nm wavelength. In impedance method, sensor output is 132.33mV at middle point and 117.10mV at edge point in the channel. Experimental results show that the optimal frequency range of sensor output is Iron 50Hz to 400Hz.

  • PDF

Proton Conductivity Measurement Using A.C. Impedance Spectroscopy for Proton Exchange Membrane

  • Lee, Chang Hyun;Park, Ho Bum;Lee, Young Moo
    • Korean Membrane Journal
    • /
    • 제6권1호
    • /
    • pp.1-9
    • /
    • 2004
  • The impedance and the subsequent proton conductivity of Nafion$\^$/ membranes as standard samples were measured and compared via the two-probe method and the four-probe method using the prepared impedance measurement system. The different impedance behavior for the same membrane was observed at the fully hydrated state in the Nyquist impedance plot. The effect of the humidity and the temperature on the proton conduction through a membrane was investigated and compared with two different cell configurations.

Microfabricated Cell Chip for Cell-based in vitro Assay

  • 박제균;김태한;이상은;김수현;윤규식;이정건
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 추계학술발표대회 및 bio-venture fair
    • /
    • pp.115-118
    • /
    • 2000
  • 미세 가공 기술을 이용하여 제작된 IDA 전극을 활용하여 임피던스 측정방식의 cell chip으로의 응용에 대해 고찰하였다. IDA 전극은 기존의 반도체 공정으로서 손쉽게 제작할 수 있고, 대량 제작시 전극의 재현성 확보가 용이하고 소형화 할 수 있으며 낮은 단가로 제작될 수 있는 장점이 있다. IDA 전극을 채용한 cell chip을 B16-F1 melanoma 세포 배양에 적용한 결과, 세포성장과 임피던스 변화량이 상관성을 보였고, 세포의 성장을 저해하는 약물의 투과시 cell chip의 임피던스 변화 역시 기존의 방법과 유사한 결과를 보여 주었다.

  • PDF

Early Detection of Peripheral Intravenous Infiltration Using Segmental Bioelectrical Impedance: Preliminary Study

  • Kim, Jaehyung;Jeong, Ihnsook;Baik, Seungwan;Jeon, Gyerok
    • 한국멀티미디어학회논문지
    • /
    • 제20권3호
    • /
    • pp.482-490
    • /
    • 2017
  • Early detection of infiltration is one of the most important tasks of nurses to minimize skin damage due to infiltration. For subjects receiving invasive intravenous treatment, the bioelectrical impedance (impedance) were measured in the frequency range of 5 to 500 kHz using bioelectrical impedance spectroscopy (BIS). After attaching electrodes at both ends of a transparent dressing mounted on the skin in which IV solution was infused into the vein, the change in impedance was measured as a function of time and frequency before and after infiltration. The experimental results are described as follows. When IV solution was properly infused into the vein, the impedance was nearly constant over time and decreased with increasing frequency. However, when infiltration occurred, the impedance decreased significantly and thereafter gradually decreased with time. In addition, impedance decreased with time for all applied frequencies. In this study, when IV solution penetrated into the surrounding skin and subcutaneous tissue by infiltration, impedance was quantitatively analyzed for as a function of time and frequency. This suggests a method for early detection of infiltration using BIS.

Bioelectrical Impedance Analysis at Popliteal Regions of Human Body using BIMS

  • Kim, J.H.;Kim, S.S.;Kim, S.H.;Baik, S.W.;Jeon, G.R.
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.1-7
    • /
    • 2016
  • Bioelectrical impedance (BI) at popliteal regions was measured using a bioelectrical impedance measurement system (BIMS), which employs the multi-frequency and the two-electrode method. Experiments were performed as follows. First, a constant AC current of $800{\mu}A$ was applied to the popliteal regions (left and right) and the BI was measured at eight different frequencies from 10 to 500 kHz. When the applied frequency greater than 50 kHz was applied to human's popliteal regions, the BI was decreased significantly. Logarithmic plot of impedance vs. frequency indicated two different mechanisms in the impedance phenomena before and after 50 kHz. Second, the relationship between resistance and reactance was obtained with respect to the applied frequency using BI (resistance and reactance) acquired from the popliteal regions. The phase angle (PA) was found to be strongly dependent on frequency. At 50 kHz, the PA at the right popliteal region was $7.8^{\circ}$ slightly larger than $7.6^{\circ}$ at the left popliteal region. Third, BI values of extracellular fluid (ECF) and intracellular fluid (ICF) were calculated using BIMS. At 10 kHz, the BI values of ECF at the left and right popliteal regions were $1664.14{\Omega}$ and $1614.08{\Omega}$, respectively. The BI values of ECF and ICF decreased sharply in the frequency range of 10 to 50 kHz, and gradually decreased up to 500 kHz. Logarithmic plot of BI vs. frequency shows that the BI of ICF decreased noticeably at high frequency above 300 kHz because of a large decrease in the capacitance of the cell membrane.

교류 임피던스법에 의한 인산형 연료전지의 산소전극 특성 연구 (AC Impedance Study of Oxygen Electrode in Phosphoric Acid Fuel Cell)

  • 송락현;김창수;신동열
    • 전기화학회지
    • /
    • 제3권4호
    • /
    • pp.191-195
    • /
    • 2000
  • 교류 임피던스법을 사용하여 온도, 부하전위 및 전극내 테프론 함량에 따른 인산형 연료전지의 산소전극 반응의 특성을 연구하였다. $105wt.\%$ 인산에서 산소 전극의 임피던스 거동은 전극 계면 저항, 전극 계면 캐패스턴스 및 전해질 저항으로 이루어진 간단히 회로로 특징지어지고, 이것으로부터 구한 인산의 전기전도도는 $130\~190^{\circ}C$의 온도범위에서 0.31-0.47 S/cm 로 나타났다. 부하전위와 온도가 증가함에 따라 산소극의 계면저항은 감소하였으나 산소극의 계면 캐패스턴스는 증가하였으며, 이것은 산소극의 반응속도와 전극의 계면 임피던스가 직접적인 관계를 가진다는 것을 의미한다. 테프론 함량에 따른 인산형 연료전지 단전지의 성능을 조사하여 임피던스 측정결과와 비교하였으며, $40wt.\%$에서 최대 성능을 나타내었고, 이것은 산소극의 계면 임피던스 값이 최적 상태를 나타내었기 때문인 것으로 판단되며, 이러한 결과들이 전극의 3상계면 상태와 연관지어 토의되었다.

GNP법을 이용한 고체산화물 연료전지의 공기극용 La0.75Sr0.25FeO3의 제조 및 특성 (Synthesis and Characterization of La0.75Sr0.25FeO3 Used as Cathode Materials for Solid Oxide Fuel Cell by GNP Method)

  • 박주현;손희정;임탁형;이승복;윤기석;윤순길;신동열;송락현
    • 전기화학회지
    • /
    • 제10권1호
    • /
    • pp.7-13
    • /
    • 2007
  • Glycine Nitrate Process(GNP)를 이용하여 $La_{0.75}Sr_{0.25}FeO_3$를 합성하였다. 이때, GNP의 글리신의 함량은 화학양론식으로 계산하여 3.17mol을 첨가하였다. ICP-AES분석으로 각각의 조성 함량을 조사하고, XRD, SEM분석으로 합성된 분말의 결정성과 입자크기를 분석하였다. 이렇게 분석한 분말은 일축가압 성형으로 펠렛을 제조하였으며, 이 시편은 $1200^{\circ}C$에서 소결하였다. 소결된 시편은 아르키메데스 법을 이용하여 소결밀도를 측정히였다. 전기화학적 성능을 평가하기 위해 AC impedance spectroscopy로 측정하였으며, GNP 법으로 합성된 LSF가 기존의 LSM 보다 낮은 Ohmic resistance및 Polarization resistance를 보임을 확인하였다. 또한 합성된 LSF를 양극으로 사용하여 연료극 지지체식 고체산화물 연료전지의 단위전지를 제작하였으며, 그 성능은 $750^{\circ}C$에서 $342mW/cm^2(0.7V,\;488mA/cm^2)$을 나타내었다. 마지막으로 임피던스 분석에 의하여 단위전지의 전기화학적 분극저항을 평가하였다.

Volatile Organic Compound Specific Detection by Electrochemical Signals Using a Cell-Based Sensor

  • Chung, Sang-Gwi;Kim, Jo-Chun;Park, Chong-Ho;Ahn, Woong-Shick;Kim, Yong-Wan;Choi, Jeong-Woo
    • Journal of Microbiology and Biotechnology
    • /
    • 제18권1호
    • /
    • pp.145-152
    • /
    • 2008
  • A cell-based in vitro exposure system was developed to determine whether oxidative stress plays a role in the cytotoxic effects of volatile organic compounds (VOCs) such as benzene, toluene, xylene, and chlorobenzene, using human epithelial HeLa cells. Thin films based on cysteine-terminated synthetic oligopeptides were fabricated for immobilization of the HeLa cells on a gold (Au) substrate. In addition, an immobilized cell-based sensor was applied to the electrochemical detection of the VOCs. Layer formation and immobilization of the cells were investigated with surface plasmon resonance (SPR), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). The adhered living cells were exposed to VOCs; this caused a change in the SPR angle and the VOC-specific electrochemical signal. In addition, VOC toxicity was found to correlate with the degree of nitric oxide (NO) generation and EIS. The primary reason for the marked increase in impedance was the change of aqueous electrolyte composition as a result of cell responses. The p53 and NF-${\kappa}B $ downregulation were closely related to the magnitude of growth inhibition associated with increasing concentrations of each VOC. Therefore, the proposed cell immobilization method, using a self-assembly technique and VOC-specific electrochemical signals, can be applied to construct a cell microarray for onsite VOC monitoring.