• Title/Summary/Keyword: ceiling

Search Result 983, Processing Time 0.025 seconds

Comparison of Acoustic Performance Depending on the Location of Sound Absorptive and Diffuser in Small Auditoriums Using 1/10 Scale Models (1/10 축소모형을 이용한 소공연장의 흡음재와 확산체의 적용위치에 따른 음향성능 비교)

  • Kim, Tae-Hee;Park, Chan-Jae;Park, Ji-Hoon;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.2
    • /
    • pp.146-156
    • /
    • 2015
  • This study investigated how the location of sound absorptive materials and sound diffusers affects the acoustic performance of small auditoriums. It was conducted for a standard model established with the averaged dimension of 36 auditoriums which had opened since 2000 in Daehak-ro, Seoul. In this study, the installation area of finishing materials was calculated upon a back wall which had the smallest installation effective area of finishing materials. To analyze the changes of acoustic performance according to installation location of finishing materials, experiments were carried out using the 1/10 down scale models for 8 cases which were made by classifying the installation location of ceiling and side wall into the front, middle and rear part.The used acoustic parameters were reverberation time (RT), early decay time (EDT), clarity (C80), definition (D50) and speech transmission index (STI). In result, the index related to the amount of reverberant sound (RT, EDT) showed the great changes when evaluating it through just noticeable difference (JND), but the one related to clarity (C80, D50, STI) hardly indicated the changes. In case to obtain short reverberation time, it was most effective to control reverberation time through the side walls when installing sound absorptive and diffusive materials, and side wall front was the location which could get the shortest reverberation time.

A Case Study of the Improvement of the Structural Work of a Logistics Facility by Using PC Member (PC부재에 의한 물류시설의 골조공사 개선사례 연구)

  • Kim, Seon-Hyung;Choi, Eun-Gyu;Kim, Sun-Kuk;Lee, Sung-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.6
    • /
    • pp.127-135
    • /
    • 2010
  • As logistics facilities have a high ceiling height, simple structure, and the need for a quick return on investment, it is usually essential to advance the construction schedule of such facilities. Accordingly, PC structures, which require less labor, cost and schedule, can be more competitive than RC structures. However, most construction companies in Korea are familiar with RC structure design, have negative perceptions regarding PC structures, and do not sufficiently adopt new construction techniques. The structure that this research features has 110 columns that are 14 m high and are built to the same specification, and applying an RC design to the structure will lead to issues related to constructibility, economic viability, project duration and safety. Therefore, this study intends to feature PC design as an alternative to the RC warehouse design, and perform a comparative analysis of the reduction in labor, cost and construction schedule to highlight benefits. The research outcomes herein will provide inputs to subsequent studies on new construction strategies to advance the construction schedule, improve quality and constructibility, enhance safety and save costs.

Origins and Protective Schemes of Leaking Water into the Buddhist Triad Cave in Gunwi (군위 삼존석굴의 누수 원인과 방지대책)

  • Hwang, Sang Koo
    • Journal of Conservation Science
    • /
    • v.11 no.1 s.14
    • /
    • pp.15-27
    • /
    • 2002
  • The Buddhist Triad Cave in Gunwi, which consists of porphyritic biotite granite, has been deteriorated by a few weatherings. Origin of the weatherings is rain that can be leaked into the cave. Therefore the author investigates a few possible joints and bypasses leaking water, and reinforces any protective schemes for the rain influx. The porphyritic granite around the cave regularly develops two NEE and NWW joint sets. The NEE joint set could be divided into 4 joint zones among which $J_m\;and\;J_3$ may directly affect the leaking water into the cave. A extensional joint, in northern wall of the cave, runs through the $J_m$ joint zone. A small rain could rarely gets through the bypass, but a heavy rain has a good circulation through the joints to be leaked into the cave for a long time because of its long way. Many joints and cracks, in the ceiling near the cave entrance, immediately get to the $J_3$ joint zone, and have a good circulation of a small rain 10 mm. It is the desirable protective schemes that forbid rains to influx along the ranges from L -9 m to +10 m in the $J_m$ joint zone and upper half circle with radius 5 m in the $J_3$ joint zone. The joint apertures should be filled with a petro-epoxy and petro-filler to stop the water flow.

  • PDF

An evaluation of the composition and elements in Korean traditional interior space - On Choosa-Gotack in the Chosun dynasty - (한국전통 실내공간의 구성방법과 요소 분석을 통한 의미 고찰 - 조선조 추사고택을 중심으로 -)

  • 천진희
    • Archives of design research
    • /
    • no.16
    • /
    • pp.101-110
    • /
    • 1996
  • CHOOSA GORACK which is a typical example of traditional houses in the CHO SEON dynasty consists of the four terraced builfing group. Among those,SADANG CHAI are located in the highest level,and SADANG CHAI and SADANG CHAI are toward south direction.It means that building orientation and level were influenced by the distinction of social level and the idea of ancester worship. Floor and ceiling level in the same building is different which was caused by the distinetion of social level in the CHO SEON dynasty and an ariental dual as a variety of openings,exposed ceilings,and furniture against a wall were creating a typical Korean visual harmony. Although the furniture and equipments were very important elements in ONDOL BANG the occupance ratio of these were low because the free space in BANG should be utilized effectively to accommodate the space variation.Both an AN CHAI and SARANG CHAI were composed by the standard space module called KAN.And interior elements were established by several factors such as the human scale,the behavior pattern in traditional sitting life style, and the lumber size of post and lintel construction of Korean house.BANG and DAE GHUNG, composed of KAN,were expanded and arranged side by side so that the natural light and ventilation through them could be used in the result of the kind of lay out,traffic circulation was disturved.In conclusion,CHOOSA GOTACK was formed by the sirect effice of the KOREAN penisula. However this study was based on one sample. It may not enough to deduct soild conclusion.Therefore continuous and farher study is needed for the sestemane evaluation.

  • PDF

Dispersion Characteristics of Hydrogen Gas by the Effect of Leakage Hole Size in Enclosure Space (누출공 크기에 따른 밀폐공간 내 수소 가스의 확산 특성)

  • Choi, Jinwook;Li, Longnan;Park, Chul-Woo;Lee, Seong Hyuk;Kim, Daejoong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.26-35
    • /
    • 2016
  • As a potential clean energy resource, the production and consumption of hydrogen gas are expected to gradually increase, so that hydrogen related studies are also increasing. The thermal and chemical properties of hydrogen result in its high flammability; in particular, there is a high risk if leaks occur within an enclosed space. In this study, we applied the computational fluid dynamics method to conduct a numerical study on the leakage behavior of hydrogen gas and compared these numerical study results with an experimental study. The leakage hole diameter was selected as an important parameter and the hydrogen gas dispersion behavior in an enclosed space was investigated through various analytical methods. Moreover, the flammable regions were investigated as a function of the leakage time and leakage hole size. We found that the growth rate of the flammable region increases rapidly with increasing leakage hole size. We also investigated the relation between the mass flow rate and the critical time when the hydrogen gas reaches the ceiling. The analysis of the monitoring points showed that the hydrogen gas dispersion behavior is isotropic and independent of the geometry. We found that the concentration of gas in an enclosed space is affected by both the leakage flow rate and amount of gas accumulated in the enclosure.

Development of a Moving Monitor System for Growing Crops and Environmental Information in Green House (시설하우스 이동형 환경 및 생장 모니터링 시스템 개발)

  • Kim, Ho-Joon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.3
    • /
    • pp.285-290
    • /
    • 2016
  • In rural area, our farmers confront decreasing benefits owing to imported crops and increased cost. Recently, the government encourage the 6th Industry that merges farming, rural resources, and information and communication technology. Therefor the government makes an investment in supplying 'smart greenhouse' in which a farmer monitor growing crops and environment information to control growing condition. The objective of this study is developing an Moving Monitor and Control System for crops in green House. This system includes a movable sensing unit, a controlling unit, and a server PC unit. The movable sensing unit contains high resolution IP camera, temperature and humidity sensor and WiFi repeater. It rolls on a rail hanging beneath the ceiling of a green house. The controlling unit contains embedded PC, PLC module, WiFi router, and BLDC motor to drive the movable sensing unit. And the server PC unit contains a integrated farm management software and home pages and databases in which the images of crops and environment informations. The movable sensing unit moves widely in a green house and gathers lots of information. The server saves these informations and provides them to customers with the direct commercing web page. This system will help farmers to control house environment and sales their crops in online market. Eventually It will be helpful for farmers to increase their benefits.

Evaluation of Effective Dose and Exposure Levels of Radon in Office and Plant Buildings (일부 제조업 사업장의 사무 및 공장동에서의 라돈농도 수준 및 유효선량 평가)

  • Chung, Eun Kyo;Kim, Ki Woong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.1
    • /
    • pp.38-45
    • /
    • 2017
  • Objectives: Radon may be second only to smoking as a cause of lung cancer. Radon is a colorless, tasteless radioactive gas that is formed via the radioactive decay of radium. Therefore, radon levels can build up based on the amount of radium contained in construction materials such as phospho-gypsum board or when ventilation rates are low. This study provides our findings from evaluation of radon gas at facilities and offices in an industrial complex. Methods: We evaluated the office rooms and processes of 12 manufacturing factories from May 14, 2014 to September 23, 2014. Short-term data were measured by using real-time monitoring detectors(Model 1030, Sun Nuclear Co., USA) indoors in the office buildings. The radon measurements were recorded at 30-minute intervals over approximately 48 hours. The limit of detection of this instrument is $3.7Bq/m^3$. Also, long-term data were measured by using ${\alpha}-track$ radon detectors(${\alpha}-track$, Rn-tech Co., Korea) in the office and factory buildings. Our detectors were exposed for over 90 days, resulting in a minimum detectable concentration of $7.4Bq/m^3$. Detectors were placed 150-220 cm above the floor. Results: Radon concentrations averaged $20.6{\pm}17.0Bq/m^3$($3.7-115.8Bq/m^3$) in the overall area. The monthly mean concentration of radon by building materials were in the order of gypsum>concrete>cement. Radon concentrations were measured using ${\alpha}-track$ in parallel with direct-reading radon detectors and the two metric methods for radon monitoring were compared. A t-test for the two sampling methods showed that there is no difference between the average radon concentrations(p<0.05). Most of the office buildings did not have central air-conditioning, but several rooms had window- or ceiling-mounted units. Employees could also open windows. The first, second and third floors were used mainly for office work. Conclusions: Radon levels measured during this assessment in the office rooms of buildings and processes in factories were well below the ICRP reference level of $1,000Bq/m^3$ for workplaces and also below the lower USEPA residential guideline of $148Bq/m^3$. The range of indoor annual effective dose due to radon exposure for workers working in the office and factory buildings was 0.01 to 1.45 mSv/yr. Construction materials such as phospho-gypsum board, concrete and cement were the main emission sources for workers' exposure.

A Study on the Ratio Analysis as a Tool for Evaluating Financial Performance (병원재정 평가를 위한 비율분석에 관한 연구)

  • Chae, Young-Moon;Yun, Jung-Hyun;Lee, Hae-Jong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.19 no.2 s.20
    • /
    • pp.213-223
    • /
    • 1986
  • Ratio analysis allows a hospital to evaluate its own performance over time and to compare its performance with that of other hospitals. For this study, three types of ratio analysis were conducted based on some data on hospitals in Massachusetts. First, Key ratios influencing financial performance were identified using discriminant analysis. Second, the financial structures of the teaching and the non-teaching hospitals were compared using ratios and multiple comparison method. Third, the effects of the prospective reimbursement law of the state on financial performance were examined using ratios and paired t-test. The purpose of the law is to reduce hospital costs by setting the revenue ceiling prior to the effective budget year. The findings of this study were as follows: 1) When hospitals were divided into three groups, according to their operating income, only profitability ratios showed a consistent difference among the groups. 2) In the discriminant analysis, five ratios were selected: current ratio, operating margin, return on assets, fixed assets turnover, and inventory turnover. They are the key ratios to be monitored periodically for the purpose of evaluating the financial performance of hospitals. 3) When teaching hospitals were compared with non-teaching hospitals, acid ratio, days of cash on hand, and inventory turnover were statistically significant before the law went into effect, whereas only fixed assets turnover and inventory turnover were significant afterward. Contrary to previous studies, profitability ratios of teaching hospitals were higher than those of non-teaching hospitals, although the differences were not statistically significant. 4) When the ratios between the two periods (before and after the law) were compared, three profitability ratios (operating margin, return on assets, and return on equity) were significant for teaching hospitals, whereas three activity ratios (total assets turnover, fixed assets turnover, current assets turnover) were significant for non-teaching hospitals. Furthermore, while both total operating revenue and expenses were decreased, net operating income was increased, due to a greater decrease in total operating expenses. This shows that the law can indeed, simultaneously, achieve both a reduction in costs as well as an improvement in the financial situation of hospitals.

  • PDF

An Experimental Study of Sprinkler system for Sandwich Panel Wall Protection (샌드위치패널 벽면보호용 스프링클러설비 적용 실험)

  • Seo, Dong-Hun;Kim, Won-Hyung;Kim, Jong-Hoon;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.37-43
    • /
    • 2017
  • Domestic sandwich panel buildings are widely used on walls and roofs of factories and warehouse facilities. Factory and warehouse facilities have high fire load and rapid spread of fire due to their use characteristics, leading to large fires. Due to the characteristics of materials, walls and roofs are collapsed, resulting in life damage and property damage. In this regard, this study examined domestic and international standards of sprinkler facilities to prevent ignition of sandwich panel walls. Also, in order to check whether the fire was prevented by installing the head on the wall of the sandwich panel, the fire test was carried out with 10 cm, 60 cm, and 120 cm from the wall along the sprinkler head installation standard of domestic fire safety standards. As a result of the fire test, it was confirmed that the sandwich panel was prevented from igniting when the head of water pressure 0.1 MPa and water quantity K-80 was installed. According to the separation distance, it was impossible to measure the temperature at 10 cm, but at 60 cm, At the maximum temperature of $525^{\circ}C$ and 120 cm, the maximum temperature of the wall of the sandwich panel was measured as $276^{\circ}C$. As a result of the fire test, considering the fire point of 450 degrees Celsius in the fire test of the sandwich panel, the distance from the sandwich panel wall to the combustible is more than 120 cm.

Preferences of Stroke Patients for Kitchen Environment in Residential Space (주거공간의 부엌 환경 특성에 대한 뇌졸중 환자의 선호)

  • Baek, Da-Rae;Jung, Yeon-Jin;Kang, Suk-Gu;Kim, Hee-Jung;Lee, Chun-Yeop
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.4 no.2
    • /
    • pp.1-10
    • /
    • 2014
  • Objective : The purpose of this study was to investigate the preferences of kitchen environment for stroke patients. Methods : The subjects of this study were 97 who have experience in rehabilitation therapy at hospitals in Busan. A questionnaire was distributed and collected from February 24th to March 13th, 2014. Descriptive statistics of frequency Study were used to analyze data. Results : First, the subjects demand for improvement that use a chair for work and install non-slip tiles. Second, they preferred the non-slip mat, boilers in heating equipment, drawer storage, L-shaped safety handle, adjustable sink of the height, automatic cutout of gas leak, faucet of touch-sensitive type, ㄷ-shaped kitchen and the ceiling-type hood in ventilation system. Third, they need kitchen items such as the sink self coming down, scissors for slices and knife to avoid hand injury. Conclusion : This study would contribute to kitchen environment for fall prevention and ease in use.

  • PDF