• Title/Summary/Keyword: ceiling

Search Result 983, Processing Time 0.027 seconds

Evaluation of Sound Quality of Air-conditioning Noise (에어컨 소음의 Sound Quality 평가)

  • Jeon, Jin-Yong;You, Jin;Kim, Su-Yeon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.5 s.110
    • /
    • pp.551-558
    • /
    • 2006
  • Noise from air-conditioner system installed in the ceiling of a classroom was evaluated to investigate the sound quality of air-conditioning noise. Harmonics of air-conditioning noise were removed and the sound pressure levels of the frequency bands from $250{\sim}630Hz$ were changed to control sound quality. Evaluation for refreshing sensation was conducted using a paired comparison method and the results showed that noise without harmonics were preferred to noise with harmonics. The noises which have larger level increases to the unchanged noise at $250{\sim}630Hz$ were evaluated better in both of the noises with and without harmonics. Results of multiple regression analysis on psychoacoustic parameters and subjective preferences showed sharpness as a major affecting factor in describing the refreshing aspect of air-conditioning sound.

Design and Control of Wall Climbing Robot Using Impeller (임펠러를 이용한 벽면이동로봇의 설계 및 제어)

  • Koo, Ig-Mo;Song, Young-Kouk;Moon, Hyung-Pil;Park, Sun-Kyu;Choi, Hyouk-Ryeol
    • The Journal of Korea Robotics Society
    • /
    • v.5 no.3
    • /
    • pp.177-185
    • /
    • 2010
  • In this paper, a wall climbing robot, called LAVAR, is developed, which is using an impeller for adhering. The adhesion mechanism of the robot consists of an impeller and two-layered suction seals which provide sufficient adhesion force for the robot body on the non smooth vertical wall and horizontal ceiling. The robot uses two driving-wheels and one ball-caster to maneuver the wall surface. A suspension mechanism is also used to overcome the obstacles on the wall surface. For its design, the whole adhering mechanism is analyzed and the control system is built up based on this analysis. The performances of the robot are experimentally verified on the vertical and horizontal flat surfaces.

Workload of Patients Transferring and its Improving Methods (병원 환자 운반 업무의 작업 부하 분석 및 개선 방안)

  • Kee, Do-Hyung
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.2 s.74
    • /
    • pp.121-127
    • /
    • 2006
  • Nursing often requires heavy physical work activities such as lifting heavy loads, working in awkward postures, transferring patients, operating hazardous equipment, etc. Among various nursing tasks, patients transferring is one of the most physically demanding tasks. This study aims to investigate workload of the patients transferring, and to propose its improving methods for reducing high workload. The results showed that irrespective of methods for patients transferring and the number of workers involved, workload for most patients transferring tasks exceeded the action limit represented in terms of L5/SI compressive force of 3,400N or LI of 1.0 by NIOSH. The loads for some tasks were far larger than the maximum permissible limit of 6,400N. It is recommended that the mechanical devices for transferring patients such as ceiling crane, sling lift etc. should be introduced rather than simply increasing the number of workers in the tasks.

Seismic Performance Evaluation of Base-Isolated Multi-Story Piping System (지진격리된 복층구조 파이핑 시스템의 내진성능평가)

  • Jeon, Jun-Tai;Ryu, Yong-Hee;Ju, Bu-Seog
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2016.11a
    • /
    • pp.311-313
    • /
    • 2016
  • 본 연구는 지진격리장치가 적용된 파이핑 시스템에서 빌딩과 같은 구조요소의 상호작용에 의한 동적 거동을 분석하고자 기존 복층구조 파이핑 시스템과 빌딩시스템에 triple friction pendulum이 적용된 격리장치를 적용 하였다. 파이핑 시스템의 시간이력해석에 의한 동적거동 평가를 위해 OpenSees를 이용하여 지진격리된 빌딩 및 파이핑시스템의 수치해석모델을 구축하였으며, 또한 파이핑시스템의 경우 ceiling system and supporting system 등과 같은 요소로 구분하여 유한요소모델을 구축하였다. 결과적으로 지진격리장치가 적용된 빌딩-파이핑 시스템의 경우 각층의 drift 및 변위가 일정한 반면 비 적용된 시스템의 경우 층 가속도에 의한 구조물의 변위가 빌딩층에 따라 상당히 증가함을 볼 수 있다.

  • PDF

A Study on the Effectso f ceiling on Emission Permits Trading (거래량이 한계설정이 배출권거래제에 미치는 영향)

  • 박진영;박영구;박찬국;김상준;최기련
    • Journal of Energy Engineering
    • /
    • v.9 no.1
    • /
    • pp.68-75
    • /
    • 2000
  • 본 연구에서는 비용효과적인 배출권거래를 모델화하여 온실가스 저감비용과 거래 이윤측면에서 한계설정이 배출권거래제에 미치는 영향을 분석하였다. 그 결과 한계저감비용곡선이 한 국가의 배출권거래 행태를 결정하는 주요요소이며, 배출권거래시장에참여하여 저감의무량의 일정분을 거래를 통해 의무를 이해하고 잔여량만을 자국의 기술력으로 저감하는 것이 비용효과적임을 확인하였다. 또한 배출권의 구매량을 제한하는 계설정은 배출권의 초과공급으로 거래가격이 낮게 형성되어 거래이윤이 구매측에 편중되었으며, 판매량 제한 또는 구매와판매 양측의 거래량을 제한할 경우는 반대로 배출권의 초과수요로 거래이윤이 판매측에 편중되는 것으로 나타났다. 그리고 거래량의 제한이 없는 경우에 가장 비용효과적인 배출권거래의 행태를 보였으나, 지구온난화에 대한 역사적 책임또는 형평성 문제, Hot air 거래등의 문제로 한계설정을 해야한다면, 구매와 판매량을 모두 제한함으로써 거래당사국들간의 이윤 편중을 완화하는 방안으로 모색해야 한다는 결론을 얻었다.

  • PDF

A Study on the Characteristics of Fires Depending on the Existence of Boring on the Ceiling (천정 천공 유무에 따른 화재 특성 연구)

  • Rie, Dong-Ho;Choi, Back-Yeol;SeoMon, Su-Cheol;Yoo, Myung-Yeol
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.16-20
    • /
    • 2010
  • 본 연구는 지하 냉동 창고 화재발생시 천공이 화재진압의 방법으로써 화재성상에 미치는 영향 등 천공의 효과를 검증하고 화재진압 기술에 대한 기초연구로서 천공의 위치, 천공 개방 시간, 천공 개방에 따른 근접 건축물로의 화재 전파양상을 FDS를 통하여 시뮬레이션 하여 분석하였다. 천공의 개방은 내부 화재의 요인을 빨리 소모시켜 온도 및 발열량을 빠르게 낮춘다. 이와 같이 천공의 유무에 따라 화재에 양상이 바뀌기 때문에 화재 진행 사항 및 화재 장소 가연물에 형태 등 각 화재 형태에 따라 적절한 천공의 위치 및 개방시간등이 마련되어야 할 것이다.

  • PDF

A Effects of applying the noise reduction method between existing buildings (기존 건축물 층간소음 저감공법 적용 효과 분석)

  • Song, Tae-Hyeob;Jeon, Chan-Soo;Kim, Ji-Hoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.249-250
    • /
    • 2018
  • To control the floor noise generated in the apartment building, a method of reinforcing the floor at the floor is applied. However, since existing buildings are difficult to reinforce upper generations, the ceilings of lower generations should be reinforced. The purpose of this study is to analyze the reduction effect by measuring the impact noise after reinforcing the floor soundproofing material on the ceiling of the existing building. In order to ensure the economical efficiency and flame retardancy of the products used as building interior materials, the existing polyurethane foam was impregnated with mineral to prepare test specimens and attached to the concrete slab surface. As a result, it was shown that heavy impact sound can reduce 2dB~5dB and light impact sound can reduce 4~8dB.

  • PDF

Daylighting Performance Evaluation of Lightshelf Window System by Lightscape (Lightscape를 이용한 광선반 창호시스템의 채광성능평가)

  • Moon, Ki Hoon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.4 no.4
    • /
    • pp.45-52
    • /
    • 2004
  • Simulation of daylighting by computer program is a method to avoid unnecessary efforts in manufacture of its testing models, to reduce its measuring tolerances and be able to provide variations of various weather conditions as well. Many simulation programs on daylighting have been released freely or commercialized for selling, however, a demonstration of their availability and validity as a tool for evaluating daylighting performance is required since each one has its own characteristics. The objectives of this study lie in suggesting an application method of evaluation tools and demonstration of limits and characteristics so as to more easily determine the daylightingperformance in the very initial stages of planning for an arbitrary office space in which windows with daylight access are built. We produced scale model of the general light inducing type side lighting with lightshelfand ceiling, and the luminance (at 78 measuring points) and illuminance (at 84 measuring points) were measured in a clear sky. And a comparison of the measured values and the calculated values from a computer simulation using the Lightscape program was performed.

Analysis of Thermal Comfort for Ceiling and Floor Supply Air-conditioning System (냉방시 천장분출 및 바닥분출 공조방식에 따른 열환경 평가)

  • 이기섭;김영일
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1998.04a
    • /
    • pp.249-254
    • /
    • 1998
  • 생활수준이 향상됨에 따라 인간의 감성을 생활환경에 적용하려는 연구가 진행되고 있다. 감성에 영향을 미치는 요인은 다양하나 이 중에서도 열환경은 인간에게 미치는 정도가 어떠한 요인보다도 큰 것으로 알려져있다. 열환경이라 함은 온도, 습도, 기류, 복사열을 말하며 이 요소들은 인간의 감성과 밀접한 관련을 지닌다. 실내의 열환경은 공조방식에 따라 크게 달라지며 본 연구에서는 천장분출과 바닥분출 공조방식에 따른 실내의 열환경을 평가한다. 두 공조방식을 여름철 사무실 공간에 적용하여 실내의 온도, 기류, 복사온도, PMV의 분포를 수치해석적으로 계산한다. 해석 결과 바닥분출 공조방식이 쾌적성과 에너지 절약면에서 우수함을 알 수 있었다.

  • PDF

A Study on the Fire Safety Performance of Interior Surface Materials in a Building (건축물의 실내건축 재료에 관한 화재안전성 연구)

  • Seo, Su-Eun;Shin, Seung-Woo
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2013.11a
    • /
    • pp.275-290
    • /
    • 2013
  • The main cause of building fire fatalities occur in the combustible material heat, smoke and toxic gases are. Building interior decoration, etc., especially as much of the harmful substances generated during combustion, and, used in domestic architecture wallpaper, ceiling, and other plastics, built-in foam insulation also analyzed recognition of fire hazards approach to test the conkalrorimiteo test, choedaeyeolbangchulryul through, chongbal heat, mass loss rate, generates carbon monoxide gas hazard ratio tests, analysis and evaluation rigid foam index testing the toxicity of hazardous material generated by performing a gas clean up and assess the material test results, the minimum order to provide data to quantify the risk of fire. Ensure fire safety of building materials, composite materials in order to test the various risk factors could be considered organic to the introduction of testing and evaluation is needed urgently.

  • PDF