• Title/Summary/Keyword: ceiling

Search Result 983, Processing Time 0.027 seconds

Numerical analysis of local exhaust effectiveness using reverse-flow calculation method (역유동계산법을 이용한 국소배기효율의 수치해석)

  • 한화택
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.658-665
    • /
    • 1998
  • This paper investigates local exhaust effectiveness in a room with a supply and an exhaust slots on the ceiling. The mean age of air is an indicator of supply effectiveness, while the mean residual life time can be used as an indicator of exhaust effectiveness. The distribution of local mean residual life time in a space is calculated by four different numerical procedures. The reverse-flow calculation method has been proved to show quite accurate results while it can save considerable amount of computation time and efforts, compared to the method by its original definition. It is concluded that the diffusion term in the equation of mean residual life time can be neglected. The spatial and temporal diffusion characteristics of the contaminant are also discussed.

  • PDF

Thermal environment evaluation of KBS open hall with mixing ventilation and downward displacement ventilation systems (혼합환기와 하향 압출환기시스템이 동반된 KBS공개홀의 온열환경 평가)

  • 권용일;권순석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.2
    • /
    • pp.147-154
    • /
    • 1998
  • This study was carried out for evaluating the interior thermal environment in KBS Open hall with large ceiling height and large space. Ventilation systems of KBS Open hall have combined mixing ventilation and downward displacement ventilation system. Temperature and velocity was measured 130 locations with low level(0.1m), mid level(0.6m) and high level(1.1m). But relative humidity was measured at 15 locations. The subjective thermal sensation was made an inquiry of occupancy at the location measured physical elements.

  • PDF

Disengagement of a Pendant Liquid Drop from a Vibrating Ceiling (진동하는 고체면에 매달린 액적의 분리 현상)

  • 김호영;강승민;강병하
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.4
    • /
    • pp.295-303
    • /
    • 2001
  • Condensation of vapor on solid inherently accompanies generation of liquid drops on the solid surface. However, these drops prevent the solid surface from directly contacting the saturated vapor, thus causing thermal resistance. This work investigates a novel mechanism for enhancing the condensation process, in which the condensed drops are rapidly removed from a solid surface by imposing vibration on them. In the experiments, a water drop pendant from a solid surface is vibrated at a fixed frequency while increasing the vibration amplitude. Upon repeating the experiments using various frequencies, it is revealed that there exist resonant frequencies at which the minimum vibration amplitudes inducing a fall-off of the pendant drops are remarkably less than those at neighboring frequencies. These frequencies are supposed to correspond to the resonant frequencies for different modes of drop shape oscillations. They are compared with the resonant frequencies predicted by relatively simple analyses, and the factors causing discrepancy between then are discussed.

  • PDF

Convection Heat-Transfer Characteristics of Ondol-Heated Room (온돌난방공간(溫突暖房空間)의 내표면(內表面) 대류열전달특성(對流熱傳達特性)에 관(關)한 연구(硏究))

  • Sohn, J.Y.;Ahn, B.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.5
    • /
    • pp.376-385
    • /
    • 1991
  • The purpose of this paper is to propose basic data on convection heat-transfer coefficients in Ondol-heated room. Surface temperatures and several temperatures around each inside surface of wall, floor and ceiling composed of heating room are measured vertically in Ondol-heated model rooms, and the vertical temperature profiles could be expressed by nonlinear equation models. Also, the convection heat transfer phenomena are analysed from the nonlinear equation models. In the results, the convection heat-transfer coefficients of Ondol heated space are suggested by the term of temperature difference between each wall surface and room air temperature and by the relationship between Nusselt number and Rayleigh number of dimensionless numbers.

  • PDF

A Study on the Development of Fire Extinguishing System for Machinery Spaces of Small craft (무인기관실의 효과적인 자동소화장치 개발 연구)

  • Gang, Dae-Seon;Lee, Chan-Jae;Kim, Dong-Seok;Gwak, Ji-Hyeon
    • Journal of Korea Ship Safrty Technology Authority
    • /
    • s.21
    • /
    • pp.15-30
    • /
    • 2006
  • A study developing the dry powder fire extinguishing system inside the simulated machinery spaces of small boats was performed. Fire tests were conducted inside the compartments having volumes 2.9, 4.5, 8㎥ respectively. The openings and fans were estavlished on the walls of the compartments. Diesel oil was used for the test ruel, In addition fire extinguishing nozzles using dry powder were installed downward at ceiling and horizontally at the wall or conner. All fires in the test were extinguished under system activation and there was no reignition.

  • PDF

Lighting performance of high reflection wall within covered sunken garden (천창이 있는 선큰가든의 고반사율 벽면에 의한 심도 공간 채광성능)

  • Lim, Hong-Soo;Kim, Gon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.19-26
    • /
    • 2009
  • This study is performed by method for the influx of natural light in underground space. to solve the several negative underground issues make the covered courtyard and high reflected wall toward the adjacent space. for illuminance level test of sunken garden space, the adjacent space size is $15M{\times}9M{\times}12M$ sunken Garden with space to install the ceiling on the size of the companion light performance analysis, and seasonal changes derived by the light of changes in performance. In addition, increase the distance of the wall and the adjacent space and estimate the average at true time P.M12. The resulting data indicate that the road was an average lux DESKTOP RADIANCE of the modeling and analysis was conducted.

  • PDF

Indoor Single Camera SLAM using Fiducial Markers (한 대의 카메라와 Fiducial 마커를 이용한 SLAM)

  • Lim, Hyon;Yang, Ji-Hyuck;Lee, Young-Sam;Kim, Jin-Geol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.4
    • /
    • pp.353-364
    • /
    • 2009
  • In this paper, a SLAM (Simultaneous Localization and Mapping) method using a single camera and planar fiducial markers is proposed. Fiducial markers are planar patterns that are mounted on the ceiling or wall. Each fiducial marker has a unique hi-tonal identification pattern with square outlines. It can be printed on paper to reduce cost or it can be painted using retro-reflective paint in order to make invisible and prevent undesirable visual effects. Existing localization methods using artificial landmarks have the disadvantage that landmark locations must be known a priori. In contrast, the proposed method can build a map and estimate robot location even if landmark locations are not known a priori. Hence, it reduces installation time and setup cost. The proposed method works good even when only one fiducial marker is seen at a scene. We perform computer simulation to evaluate proposed method.

A Study on Church of the stage LED lighting system equipment cases (무대영상용 LED 조명 시스템 설비의 활용 가능성에 관한 연구 - 교회의 시공사례를 중심으로)

  • Lee, Jang-Weon
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.11 no.3
    • /
    • pp.61-67
    • /
    • 2011
  • This study examined the P Church in the Large chapel and S Church in the midium chapel were Analyzed to the installed stage broadcast lighting system. As a result of the installation of lighting equipment of LED class in P Church in the Large chapel, it provided clearer image and did not have shadow. While tungsten halogen illumination was very hot and heated to be preaching, LED was not heated so the pastor was very comfortable for preaching. S Church in the Midium chapel due to low ceiling height using LED lighting musical, theater and possibly were directed. If a similar structure of Dae-Hak Street theater to replace the existing fixtures by LED lighting, rendering effective and energy saving effect is thought to have much effect.

How to Fiscally Manage the BTL Type Project (BTL(Build Transfer Lease) 사업의 재정관리 방향 -국가부채 여부에 대한 판단기준 및 재정 측면에서의 관리방안을 중심으로-)

  • Choi, Seok Joon
    • KDI Journal of Economic Policy
    • /
    • v.29 no.1
    • /
    • pp.137-175
    • /
    • 2007
  • This paper studies the fiscal issues with regard to BTL (Build Transfer Lease) scheme projects, a newly introduced type of PPPs (Public Private Partnerships) in 2005 and tries to provide some policy options. More specifically, we make suggestions to work out the issues such as how to account for BTL transactions and whether to introduce annual budget ceiling system for BTL payment, while we introduce and analyze the experiences of some other advanced countries and international institutes.

Radio wave propagation simulations of indoor by finite difference time domain method (실내 전파 차분의 시간영역 유한차분법에 의한 계산)

  • 허문만;백낙준;박항구;윤현보
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.10
    • /
    • pp.60-67
    • /
    • 1997
  • This paper presents a 3-D finite difference time domain (FDTD) method used for indoor propagation simulations where the electromagnetic wav eis uniformly excited on th eone of the wall in a building and affected by an indoor obstacles. In cases of simulation and measurement, the frequency of 851 MHz is used. The conductivities of walls, floor, ceiling and indoor obstacles are measured and used for simulations. These simulations are carried out using different boundary condition such as mur's absorbing boundary condition (ABC) and perfectly matched layer (PML) technique. The PML technique is found to be well-suited to this analysis because of it's smaller computational domain than mur's ABC. The measured signal strengths are compared to simulated values with good agreement.

  • PDF