• Title/Summary/Keyword: ceiling

Search Result 983, Processing Time 0.033 seconds

Analysis of a Mount Type HVAC Control System Using Axiomatic Design (공리적 설계를 이용한 매립형 공기조화시스템의 분석)

  • Lee, Se-Jung;Hong, Eul-Pyo;Kim, Dae-Whan;Kim, Su-Ok;Park, Gyung-Jin
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1028-1033
    • /
    • 2008
  • The mount type HVAC control system is a type of an HVAC control system which is installed between a ceiling and ceiling boards of a room to control room temperature. Although the device is quite popular, design is conducted by a conventional way where engineering intuition and experiences are utilized. It is found that the design process is fairly inefficient and time-consuming because there are a lot of feedbacks. The axiomatic approach is used to investigate the design characteristics of the mount type HAVC control system and the Independence Axiom is utilized for the investigation. The Overall hierarchy is established up to the level of parts. It is found that the current design has many coupled and redundant aspects. The hierarchy is reorganized based on the Independence Axiom and a new design process is found. To exploit the new design process in practice, a design manual is made.

  • PDF

An Experimental and Analytical Studies on the Smoke Movement by Fire in High Rise Building (초고층 건축물의 화재 시 피난로 연기거동에 관한 실험 및 해석적 연구)

  • Shin, Yi-Chul;Kim, Soo-Young;Lee, Ju-Hee;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.11-14
    • /
    • 2008
  • A study on the fire and smoke behavior on experiments and analysis through STAR-CD in using about behavior analysis of the smoke. Kerosene of 3L in using on the experimental garden of 30cm in diameter same applies to heat release rate(HRR), buoyant force by Plume can be calculated at a rate of 1m/s. The result of experiment in average of velocity were 0.29m/s, and interpreted result were 0.28m/s. Besides, it is proved by interpreted that behavior of smoke movement can be not observed in the experiment. After smoke is Plume increased, ceiling-jet in formation being descend in smoke layer will be more thick smoke layer, and then vertical wall is collapsed in formation of wall-jet being descend. It is defined that smoke layer is more thick through descending course in wall-jet and ceiling-jet.

  • PDF

Internal Consistency and Concurrent Validity of Korean Language Version of WHODAS 2.0: 12 Item-Self Administered

  • Lee, Hae-Jung;Kim, Da-Jeong
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.6
    • /
    • pp.23-29
    • /
    • 2011
  • Purpose: The aim of this study was to validate the Korean version of World Health Organization Disability Assessment Schedule 2.0 (KWHODAS 2.0) in 12 item-self administered version (12-self). Methods: The KWHODAS 2.0 and Korean Functional Rating index (KFRI) were tested for internal consistency, ceiling and floor effects, and concurrent validity in 111 patients with low back pain and/or neck pain. Results: A very high level of internal consistency was shown for both instruments; ${\alpha}$=0.96 with KWHODAS 2.0; 12-self and ${\alpha}$=0.97 for KFRI. No ceiling and/or floor effects were found in both the instruments. The KWHODAS 2.0 and KFRI were highly correlated (r=0.77), and the relationship of each item between KWHODAS 2.0 and KFRI was ranging from r=0.09 to 0.72. Conclusion: We conclude that the KWHODAS 2.0: 12-self and KFRI are reliable and are valid instruments for the measurement of disability in Korean speaking patients with low back and/or neck pain. Both instruments, the KWHODAS 2.0; 12-Self and KFRI are now suitable for use in clinical practice and research applications.

Effects of Radiation Heat Transfer on the Fire in an Atrium (아트리움 공간에서 화재발생시 복사열전달의 영향 분석)

  • Yoon, Kyung-Beom;Chang, Hee-Chul;Kim, Tae-Kuk
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.18-24
    • /
    • 2007
  • The purpose of this study is focussed on the numerical predictions of temperature distribution by radiation heat transfer in atrium fire using the field fire model and the CCRHT-3D code. This code uses standard $k-{\varepsilon}$ turbulent model with SIMPLE algorithm and weighted sum of gray gases model regrouping(WSGGM-RG). The WSGGM-RG calculates radiative properties on the reduced computational loads while reserving the accuracy. The numerical results show that lower temperature distributions on the wall and the top ceiling wall can be obtained by considering radiative heat transfer. The temperature on the top ceiling wall can be an important parameter in predicting the operating condition of the sprinkler head.

A Study on Evaporator Front Air Velocity of Small Refrigeration Ceiling Dehumidifier (소형 냉각식 천정형 제습기의 증발기 전면 풍속에 관한 연구)

  • KIM, Jin-Cheol;JEONG, Kyeong-Tae;KUM, Jong-Soo;KIM, Dong-Gyu
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.28 no.4
    • /
    • pp.1107-1113
    • /
    • 2016
  • In the environment with high humidity causes negative influence on human's body and living condition. As the weather gets more humid, people's interest of dehumidifier for household arising recently. The cooling dehumidifier dehumidify the air by using refrigeration cycle technology which means it removes vapor by let the humid air pass through the cold surface. The amount dehumidified of refrigerating method dehumidifier affected by multiple factors. However, the refrigerating method dehumidifier for household in the market controls pass wind velocity technology to adjust the amount of dehumidification. As the pass wind velocity increases, the amount of wind increases hence the heat exchange amount increases accordingly. However, the amount of dehumidification decreases because the temperature difference between the air and vaporization decreases. Therefore, simply by increasing air velocity does not increase the amount of dehumidification. This research examined the effect of air velocity out of all variety of factors to the amount of dehumidification for refrigerating method dehumidifier.

A Study on Change in Window Transmitted Solar and the Resultant Wall Surface Convective Heat Gain with Regard to Slat Reflectance of External and Internal Blinds (실내·외 블라인드의 Slat 반사율에 따라 창호 일사투과량 및 그에 따른 벽체 대류열획득량 분석)

  • Hyun, In-Tak;Lee, Jae-Ho;Yoon, Yeo-Beom;Lee, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.565-571
    • /
    • 2014
  • Nowadays, to make buildings light weight and aesthetically pleasing, curtain wall structure are commonly used. Therefore, window to wall ratio is increasing, which has caused cooling and heating load in crease in buildings as well. This phenomenon has negative impact from energy point of view. This paper analyzes window and wall convective heat gain when the slat reflectance of external and internal blinds are changed for the better understanding of the fundamentals behind the phenomena. It was observed that, if slat reflectance is increased, window transmitted solar increases and convection heat rate is clearly affected. Among six surfaces including four walls, ceiling and floor, maximum convection heat rate occurs on the south wall in summer. On the other hand, ceiling and floor showed the lowest convection heat gain, since they are shared by adjacent floors.

Comparison of Speech Intelligibility depending on the Sound Source Location in the Classrooms of Middle and High Schools (음원의 위치에 따른 중${\cdot}$고등학교 교실의 음성명료도 비교)

  • Lee Hwan-Hee;Haan Chan-Hoon
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.487-490
    • /
    • 2002
  • 학교 교육의 특성상 많은 부분이 교실에서의 음성정보 전달에 의해 이루어지고 있는 점을 감안하면 바람직한 청취환경의 개선이 검토되어야 한다. 또한 중${\cdot}$ 고등학교의 수학능력시험의 국어, 영어 듣기평가 및 다양한 어학 시험이 시청각 시설을 통해 이루어지고 있는 실정이므로 교실의 음환경은 매우 중요한 요소라하겠다. 본 논문에서는 음환경을 좌우하는 음원의 위치에 따라 명료 도가 어떻게 달라지는지를 실험을 통하여 검증하고, 명료도가 높고, 교실 전체에 균등한 분포를 보이는 음원의 위치를 찾아내고자 하였다. 교실 내의 음원의 위치로는 일반적으로 많이 쓰이고 있는 column(벽면 노출형)과 ceiling(천정 매입형) 위치와 임의의 음원 cluster(전면 중앙)를 선정하여 음장 파라메터를 측정한 결과 RASTI 는 세 타입 모두 $0.54\~0.55$로 값으로 근소한 차이를 보이고 있으며, 잔향시간은 ceiling>cluster>column의 순서로 나타났다. 일반적으로 잔향과 명료도와의 관계는 반비례하는 것으로 알려져 있으나, 실험 결과 잔향시간이 1.33초로 가장 긴 column 스피커의 경우 D50 값이 약 $47\%$로 가장 높은 값으로 나타났다. 이것은 column형 스피커의 경우 음원과 각 학생의 위치에 대한 평균 직접음선거리가 가장 짧기 때문인 것으로 나타났다.

  • PDF

Energy Saving Potentials of Dedicated Outdoor Air System in a High-rise Apartment Building (외기전담 시스템 기반 초고층 공동주택 중앙 환기시스템의 에너지 절감효과 분석)

  • Kim, Min-Hwi;Kim, Jin-Hyo;Kwon, Oh-Hyun;Jeong, Jae-Weon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.291-296
    • /
    • 2009
  • This paper investigates the energy saving potentials of a dedicated outdoor air system (DOAS) applied to a highrise apartment building. As for a typical $132-m^2$ apartment unit, two different HVAC systems; centralized DOAS-Ceiling Radiant Cooling Panel and decentralized Energy Recovery Ventilator-Packaged Air Conditioner were installed. Transient behavior and control characteristics of each system were modeled numerically using a commercial equation solver program, and annual cooling coil load and heating load reduction potentials were compared. The research shows that DOAS-Ceiling Radiant Cooling Panel system can reduce the cooling coil load over 21% annually compared with the current Energy Recovery Ventilator-Packaged Air Conditioner pair. In addition, over 40% of annual ventilation heating load can be reduced by use of DOAS.

  • PDF

Projecting Performance of a Daylighting Source Based on Its Architectura Applications in the Open-Top Surface Structure (고심도 공간의 건축적 특성에 따른 자연집광 시스템의 조명원적 성능분석)

  • Kim, Gon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.9 no.1
    • /
    • pp.23-30
    • /
    • 2009
  • A lightcourt design is typically used to address issues concerning aesthetics, feeling, and mood. From the view point of environmental aspect, as an ecological shaft space, it plays a key role in controlling inner quality. In particularly, the lightcourt concept allows the exploitation of daylighting by bring natural light into the center of the building, thus eliminating dark deep spaces. Additionally, the lightcourt shades the inner space in summer. The amount of light available at the base of the lightcourt depends on a number of factors; translucency of the top, reflectance and the geometry of the space. In this paper is to exemplify a lightcourt configuration with a sloped wall. It promises the maximized a sense of freedom and daylighting availability. It is a matter of course that the lightcourt with open-top plays a role as a light source for the adjacent space to the lightcourt. A series of lighting simulation provides performance data of daylighting with changing photometric factors. For the case that a skylight is not available, an electric lighting design with metal halide lamps has been established to create luminous ceiling. As expected, a sloped lightcourt with open-top exposes its superiority of daylighting source. Ancillary considerations to enhance of daylighting potential for the adjacent space have been issued with performance data.

A Study on the Characteristics of Interior Coordination of Wedding Spacesin First Grade Hotels in Korea (국내 특급호텔 웨딩공간의 인테리어 코디네이션 특성에 관한 연구)

  • Shin, Shu-Hyun;Jeong, Yoo-Na
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2008.05a
    • /
    • pp.159-162
    • /
    • 2008
  • The main consumers of wedding market are young people. They prefer differentiated and unique wedding and with the deregulation of using five-star hotels as wedding spaces in 1999, the wedding market has entered into an era of new competition. Under the background like above, this study tries to provide the basis for the effective and systematic interior coordination of wedding spaces. For this study, large banquet halls at 16 five-star hotels in Seoul were selected. Theoretical and field examinations, and interviews were conducted. The elements of wedding space include the architectural elements of floor, walls, and ceiling and lighting, color, fabric, table setting, and flower coordination. This study found that uniformity or repetition is used for the walls while modules are used for the ceiling. Unlike the past, LED is used for lighting to create diverse colors and the range of colors used has been broadened. In addition, fabric, table setting, and flowers are used actively to create overall atmosphere of the space. When these elements are aggregated and analyzed by hotel for interior design style, Hotels H and S have modern style, Hotels L and P have elegant style and Hotel IP have classical style.

  • PDF