• Title/Summary/Keyword: cause of defects

Search Result 622, Processing Time 0.032 seconds

Detection of Void Defects in Ball Grid Array X-ray Image Using a New Blob Filter (볼 그리드 배열 기판의 X-ray 영상에서의 새로운 덩어리 검출 필터를 이용한 기포 형태 결함 검출 방법)

  • Peng, Shao-Hu;Lee, Hye-Jung;Nam, Hyun-Do
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2005-2006
    • /
    • 2011
  • Due to the advantages of small sizes, more I/O ports, etc., Ball Grid Array (BGA) has been used in the production of printed circuit board (PCB). However, BGA voids can degrade the performance of the board and cause failure. To automatically detect the voids in X-ray image, a novel blob filter that makes use of the local image gradient magnitude is proposed in this paper. The utilization of the local image gradient magnitude makes the proposed filter invariant to the image brightness, void shape, void position, and component interference. Furthermore, different sizes of box filters are employed to analyze the image in multi-scale, and as a result, the proposed blob filter is robust to void size. Experimental results show that the proposed method can obtain void detection accuracy up to 96.104% while keep low false ratio.

  • PDF

Application of a New NDI Method using Magneto-Optical Film for Inspection of Micro-Cracks (미소균열 탐상을 위한 자기광학소자를 이용한 비파괴탐상법의 제안과 적용)

  • Lee, Hyoung-No;Park, Han-Ju;Shoji, Tetsuo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.2
    • /
    • pp.197-203
    • /
    • 2001
  • Micro-defects induced by design and production failure or working environments are known as the cause of SCC(Stress Corrosion Cracking) in aged structures. Therefore, the evaluation of structural integrity based on micro-cracks is required not only a manufacturing step but also in-service term. So we introduce a new nondestructive inspection method using the magneto-optical film to detect micro-cracks. The method has some advantage such as high testing speed, real time data acquistion and the possibility of remote sensing by using of a magneto-optical film that takes advantage of the change of magnetic domains and domain walls. This paper introduces the concept of the new nondestructive inspection method using the magneto-optical film, also proves the possibility of this method as a remote testing system under oscillating load considering application on real fields by applying the method to four types of specimens.

  • PDF

Spectral Energy Transmission Method for Crack Depth Estimation in Concrete Structures (콘크리트 구조물의 균열 깊이 추정을 위한 스펙트럼 에너지 기법)

  • Shin, Sung-Woo;Min, Ji-Young;Yun, Chung-Bang;Popovics, John S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.2
    • /
    • pp.164-172
    • /
    • 2007
  • Surface cracks in concrete are common defects that can cause significant deterioration and failure of concrete structures. Therefore, the early detection, assessment, and repair of the cracks in concrete are very important for the structural health. Among studies for crack depth assessment, self-calibrating surface wave transmission method seems to be a promising nondestructive technique, though it is still difficult in determination of the crack depth due to the variation of the experimentally obtained transmission functions. In this paper, the spectral energy transmission method is proposed for the crack depth estimation in concrete structures. To verify this method, an experimental study was carried out on a concrete slab with various surface-opening crack depths. Finally, effectiveness of the proposed method is validated by comparing the conventional time-of-flight and cutting frequency based methods. The results show an excellent potential as a practical and reliable in-situ nondestructive method for the crack depth estimation in concrete structures.

Cytomegalovirus Infection among Pregnant Women in Beijing: Seroepidemiological Survey and Intrauterine Transmissions

  • Jin, Qing'e;Su, Jianrong;Wu, Shanna
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.5
    • /
    • pp.1005-1009
    • /
    • 2017
  • Primary cytomegalovirus (CMV) infection during pregnancy can cause congenital defects. Available data for CMV infection during pregnancy in north China are inadequate. The aim of this study was to evaluate the epidemiology of maternal CMV infection and explore the incidence of congenital infection. In this prospective study, serum CMV IgG and IgM antibodies were measured in 2,887 pregnant women using ELISA, and the IgG avidity test was performed on all IgM-positive subjects. The seroprevalence of anti-CMV IgG was 94.70%, and of anti-CMV IgM was 1.28%. CMV IgG prevalence increased significantly with age (p < 0.01). Women living in downtown areas showed higher IgG prevalence than those residing in urban areas (p = 0.023). CMV-IgM seroprevalence was highest in autumn (p = 0.021). There was no difference in IgM seroprevalence by age, socioeconomic status, geographical area, or gravida. The rate of primary CMV infection was 0.45% (13/2,887) at the first trimester. The seroconversion rate during pregnancy was 0.76% (22/2,887). One woman underwent seroconversion during pregnancy and gave birth to an infant with asymptomatic CMV infection. Congenital CMV infection was diagnosed in five of the 14 infants from 14 mothers with active infection, for a vertical transmission rate of 35.71% (5/14). Three infants were asymptomatic, whereas two infants presented symptomatic infection with hearing deficits. Although CMV IgG prevalence is relatively high in north China, significant attention to primary CMV infection during pregnancy is still needed.

Evaluation of Residual Stress on Pipe Welded Joints Using Laser Interferometry (레이저 간섭계를 이용한 배관 용접부 잔류응력 평가)

  • Chang, Ho-Seob;Na, Man-Gyun;Kim, Koung-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.1
    • /
    • pp.18-22
    • /
    • 2014
  • Residual stresses that occur during the welding process, are the main cause of failure and defects in welded structures. This paper, presents the use of an electronic processing laser speckle interferometer to measure the residual stress of a welded pipe for a nuclear power plant. A tensile testing machine was used to evaluate a welded pipe that failed in compression. The inform plane deformation and modulus of elasticity of the base metal and welds were measured using an interferometer. Varying the load on the welded pipe had a larger effect on the deformation of the base metal the other properties of the base metal and welds. The elastic moduli of the base metal and weld of the welded pipe were 202.46 and 212.14 GPa, respectively, the residual stress was measured to be 6.29 MPa.

Thermal Characteristic and Failure Modes and Effects Analysis for Components of Photovoltaic PCS (태양광 발전 PCS 구성부품에 대한 열적특성 및 고장모드영향분석)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Kim, Yoon-Bok
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.4
    • /
    • pp.1-7
    • /
    • 2018
  • This paper is analyzed for the thermal characteristics(1 year) of the 6 components(DC breaker, DC filter(including capacitor and discharge resistance), IGBT(Insulated gate bipolar mode transistor), AC filter, AC breaker, etc.) of a photovoltaic power generation-based PCS(Power conditioning system) below 20 kW. Among the modules, the discharge resistance included in the DC filter indicated the highest heat at $125^{\circ}C$, and such heat resulting from the discharge resistance had an influence on the IGBT installed on the rear side the board. Therefore, risk priority through risk priority number(RPN) of FMEA(Failure modes and effects analysis) sheet is conducted for classification into top 10 %. According to thermal characteristics and FMEA, it is necessary to pay attention to not only the in-house defects found in the IGBT, but also the conductive heat caused by the discharge resistance. Since it is possible that animal, dust and others can be accumulated within the PCS, it is possible that the heat resulting from the discharge resistance may cause fire. Accordingly, there are two options that can be used: installing a heat sink while designing the discharge resistance, and designing the discharge resistance in a structure capable of avoiding heat conduction through setting a separation distance between discharge resistance and IGBT. This data can be used as the data for conducting a comparative analysis of abnormal signals in the process of developing a safety device for solar electricity-based photovoltaic power generation systems, as the data for examining the fire accidents caused by each module, and as the field data for setting component management priorities.

A Cost-Benefit Analysis for the Establishment of the Truck Transportation Information Networking System in Busan Region : Using the Scenario Analysis (부산지역 화물자동차 운송정보망 구축과 경제적 타당성 분석 -시나리오분석을 중심으로-)

  • Kim, Chul-Min
    • Journal of Korea Port Economic Association
    • /
    • v.26 no.4
    • /
    • pp.101-121
    • /
    • 2010
  • Domestic trucking transportation market does not have only the poor business environment but also the serious defects on the transportation trading structure. It makes weaken the competitiveness of trucking industry and hinders the development of trucking industry. The problems of trucking industry such as the recession of the Korean economy and decrease of the trucking charge cause the truck drivers suffer. Korean government and national assembly try to change the law of truck transportation business. The suggested law includes the obligation of trucking information networking system and it can make the transportation business structures more efficiently. This article deals with the strategies for the establishment of trucking transportation networking system and examines the cost-benefit analysis assuming the four demand senario. The results suggest the establishment of the information system not based on the individual trucking industry but on the joint industry at the level of the local area. This article also suggests that the information system has a positive financial feasibility.

Molecular adaptation of the CREB-Binding Protein for aquatic living in cetaceans

  • Jeong, Jae-Yeon;Chung, Ok Sung;Ko, Young-Joon;Lee, Kyeong Won;Cho, Yun Sung;Bhak, Jong;Yim, Hyung-Soon;Lee, Jung-Hyun
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.6 no.2
    • /
    • pp.102-109
    • /
    • 2014
  • Cetaceans (whales, dolphins, and porpoises) are aquatic mammals that experienced drastic changes during the transition from terrestrial to aquatic environment. Morphological changes include streamlined body, alterations in the face, transformation of the forelimbs into flippers, disappearance of the hindlimbs and the acquisition of flukes on the tail. For a prolonged diving, cetaceans acquired hypoxia-resistance by developing various anatomical and physiological changes. However, molecular mechanisms underlying these adaptations are still limited. CREB-binding protein (CREBBP) is a transcriptional co-activator critical for embryonic development, growth control, metabolic homeostasis and responses to hypoxia. Natural selection analysis of five cetacean CREBBPs compared with those from 15 terrestrial relatives revealed strong purifying selection, supporting the importance of its role in mammals. However, prediction for amino acid changes that elicit functional difference of CREBBP identified three cetacean specific changes localized within a region required for interaction with SRCAP and in proximal regions to KIX domain of CREBBP. Mutations in CREBBP or SRCAP are known to cause craniofacial and skeletal defects in human, and KIX domain of CREBBP serves as a docking site for transcription factors including c-Myb, an essential regulator of haematopoiesis. In these respects, our study provides interesting insights into the functional adaptation of cetacean CREBBP for aquatic lifestyle.

Identification of Dominant Cause of Cut-Slope Collapse and Monitoring of Reinforced Slope Behavior (개착사면의 붕락요인 분석 및 보강거동 계측)

  • Cho, Tae-Chin;Lee, Sang-Bae;Lee, Guen-Ho;Hwang, Taik-Jean;Kang, Pil-Gue;Won, Byung-Nam
    • Tunnel and Underground Space
    • /
    • v.21 no.1
    • /
    • pp.20-32
    • /
    • 2011
  • Failure aspects of cut-slope, which induce the sequential collapses during the excavation stage, have been analyzed. Slope rock structures are investigated by examining the orientations and positions of discontinuity planes calculated based on the BIPS image inside the boreholes. Drilled core log has been also used to identify the structural defects. Clay minerals of swelling potentials are detected through XRD analysis. Numerical analysis for slope stability has been performed by utilizing the joint shear strength acquired from the direct joint shear test. Cut-slope collapse characteristics have been studied by investigating the posture of failure-prawn joint planes and the stability of tetrahedral blocks of different sizes. Cross-section analysis has been also performed to analyze the cut-slope behavior and to estimate the amount of reinforcement required to secure the stability of cut-slope. Behavior of reinforced cut-slope is also investigated by analyzing the slope monitoring data.

Evaluation of Suitability of Non-Standardized Test Block for Ultrasonic Testing (비규격 초음파 탐상용 표준시험편의 사용안전성 평가)

  • Kwon, Ho-Young;Lim, Jong-Ho;Kang, Sei-Sun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.5
    • /
    • pp.431-437
    • /
    • 2000
  • Standard Test Block(STB) for UT(Ultrasonic Testing) is a block approved by authoritative for material, shape and quality. STB is used for characteristic tests, sensitivity calibration and control of the time base range of UT inspection devices. The material, size and chemical components of STB should be strictly controled to meet the related standards such as ASTM and JIS because it has an effect upon sensitivity, resolution and reproductivity of UT. The STBs which are not approved are sometimes used because the qualified STBs are very expensive. So, the purpose of this study is to survey the characteristics, quality and usability of Non-Standardized Test Blocks. Non-Standardized Test Blocks did not meet the standard requirements in size or chemical components, and ultrasonic characteristics. Therefore if the Non-Standardized Test Blocks are used without being tested, it's likely to cause errors in detecting the location and measuring the size of the defects.

  • PDF