• Title/Summary/Keyword: cause of defect

Search Result 547, Processing Time 0.025 seconds

Analysis of the Effect of Small-Bore Piping Resonance Frequency on Defect of Welding Area (용접부의 결함이 소구경배관의 공진 주파수에 미치는 영향 분석)

  • Yoon, Min Soo;Song, Ki O;Lee, Jae Min;Ha, Seung Woo;Cho, Sun Young
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.5
    • /
    • pp.9-14
    • /
    • 2018
  • The piping system of a nuclear power plant plays a role of transferring high energy fluid to equipment and various devices. The safety and soundness of these piping systems are very closely related to the operability of the power plant. In the case of a welded part of a small diameter pipe, it may grow as a microcrack due to a lack of penetration, and it may grow to a size that affects the safety of the pipe due to the influence of mechanical vibration and fatigue load. Resonance refers to an increase in energy as the natural frequency of an object coincides with the frequency applied to the external force. When this resonance occurs, the frequency is the resonance frequency. In this study, when defects exist in the welds of small diameter pipe, the natural frequency of the pipe changes and resonance may occur. Since these resonances are likely to cause fatigue damage to the piping, resonance frequency changes due to the size and shape of the defects are analyzed and evaluated. As a result of the vibration test, the resonance frequency tended to decrease as the depth of the defect deepened, and the influence was larger when the defect existed at the bottom of the top of the trough. Also, it was confirmed that the Transverse cracks had an effect on the resonance frequency in the presence of the cracks in the weld bead, compared to the longitudinal cracks. As a result of this study, it is expected that the cause of the defect and the condition of the pipe can be monitored because the resonance frequency tendency according to the shape of the crack is analyzed.

Assessment of the Relationship between Vigabatrin and Visual Field Defect in Children (항경련제 Vigabatrin이 시야에 미치는 영향)

  • Chung, Sa Jun;Chung, Yong Hwan;Cho, Eu Hyun
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.12
    • /
    • pp.1546-1550
    • /
    • 2002
  • Purpose : The authors carried out this study to determine the relationship between vigabatrin (VGB) and visual field defect.. Methods : Seventy eight patients older than 8 years who had epilepsy which had developed and been diagnosed, and were receiving add-on therapy, were the subjects of this study. If suspicious results were obtained from the initial test with the Humphrey automatic perimeter, the patient was tested again with the Goldman perimeter. Follow-up examinations were performed on these patients after 6 months. Results : In this study, five of the 78 patients had suspicious primary test results, but upon the second examination they were all found to be normal. Thus there were no patients with visual field defects. Conclusion : VGB is a drug which may cause visual field defects, but in this study no patients presented with this symptom. Instead of limiting the use of VGB due to the adverse effect of visual field defect in the initial treatment of partial seizure and infantile spasm untreatable with other medication, if used with care it may not cause serious problems. Screening for visual defect is recommended, and in patients taking VGB regular examination is necessary.

The Evaluation of Thin Pressure Vessel′s Internal Defects by Laser Shearography (레이저 전단 간섭계를 이용한 압력용기의 내부 결함 평가)

  • 장경영;장석원;현민관
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.929-933
    • /
    • 2003
  • Internal defects of thin pressure vessel used in the power plants or the chemical plants may be created and grow due to corrosion or creep fatigue to reduce the strength and cause critical failure during operation. Therefore it is very important to detect this defect at the early stage. For this purpose, non-destructive, non-contact and highly sensitive method should be considered for on-line application. In this paper, a laser shearographic interferometer is applied to inspect circular defects and notch defects existed inside of thin pressure vessel under the presence of pressure up to 3 times of atmospheric pressure. The influences of the defect shape and size as well as the internal pressure to the characteristic pattern in the shearography fringe are investigated, and the quantitative evaluation of the defect size is tried. Also the experimental results are compared with the destructive test results to show the applicability of this method to the quantitative evaluation of internal defects in the thin pressure vessel.

  • PDF

Clinical Evaluation of 70 Cases of Ventricular Septal Defect in Korea (심실 중격결손증에 대한 임상적 고찰 [70예])

  • 조규석
    • Journal of Chest Surgery
    • /
    • v.11 no.1
    • /
    • pp.46-57
    • /
    • 1978
  • Ventricular septal defect was the most common congenital Heart disease admitted to the Severance Hospital from December, 1963 to June 30. 1977. A total of 1,811 cardiac patients received cardiac catheterization in the CardiacCenter of Yonsei University Medical College. Out of the 1,811 cardiac patients, 791 cases had congenital heart disease and of these 172 cases had ventricular septal defect. This amounted to 21.7% of all those with congenital heart disease. Seventy cases of ventricular septal defect operated on in the chest surgery department are presented. Of these 70 cases of ventricular septal defect, 54 cases were male and 16 cases were female. Their ages ranged from 4/12 months to 32 years. The ratio of systolic pressure of the main pulmonary to systemic artery [Pp/Ps] for 29 of the 59 isolated ventricular septal defects was below 45 percent. Pp/Ps ratio for 19 of the 59 isolated ventricular septal defects was 75 percent. The patients were mostly below fifteen years of age. Out of 64 cases, there were 36 cases of type II defects, 20 cases of type I, 4 cases of type III , 2 cases of type IV, one case of both type II and one case of left ventricular right atrial communication. The anomalies associated with ventricular septal defect were 13 in all; 4 cases of aortic insufficiency, 3 cases of ruptured aneurysm of the sortie sinus of valsalva, 2 cases of ruptured aneurysm of the sortie sinus of valsalva with aortic insufficiency, 2 cases of patent ductus arteriosus, one case of ruptured aneurysm of the aortic sinus of valsalva with atrial septal defect [secundum type] and one case of atrial septal defect [secundum type]. Overall mortality was 8.6 percent. The mortality in pulmonary artery banding was 37.5 percent. The causes of mortality were in one case congestive heart failure, in one case asphyxia and in one case respiratory insufficiency. Tile mortality in ventricular septal defect associated with pulmonary hypertension was 7.1 percent. The cause of mortality was in one case low cardiac output syndrome. There was no mortality in the ventricular septal defects without pulmonary hypertension and mortality in the ventricular septal defect. In ventricular septal defect associated with combined anomalies, the causes mortality were in one case respiratory insufficiency and in one case congestive heart failure.

  • PDF

Electrical Characteristics of Oxide Layer Due to High Temperature Diffusion Process (고온 확산공정에 따른 산화막의 전기적 특성)

  • 홍능표;홍진웅
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.10
    • /
    • pp.451-457
    • /
    • 2003
  • The silicon wafer is stable status at room temperature, but it is weak at high temperatures which is necessary for it to be fabricated into a power semiconductor device. During thermal diffusion processing, a high temperature produces a variety thermal stress to the wafer, resulting in device failure mode which can cause unwanted oxide charge or some defect. This disrupts the silicon crystal structure and permanently degrades the electrical and physical characteristics of the wafer. In this paper, the electrical characteristics of a single oxide layer due to high temperature diffusion process, wafer resistivity and thickness of polyback was researched. The oxide quality was examined through capacitance-voltage characteristics, defect density and BMD(Bulk Micro Defect) density. It will describe the capacitance-voltage characteristics of the single oxide layer by semiconductor process and device simulation.

Aortic Valvoplasty for Aortic Insufficiency with Ventricular Septal Defect (대동맥판 폐쇄부전이 동반된 심실중격결손에서 대동맥판성형술)

  • Lee, Sin-Yeong;Kim, Chang-Ho
    • Journal of Chest Surgery
    • /
    • v.26 no.4
    • /
    • pp.266-270
    • /
    • 1993
  • Aortic valve insufficiency with ventricular septal defect is usually treatment by plication of prolased cusps. We have performed the aortic valvuloplasty by the Trusler`s method in 14 patients of ventricular septal defect associated with aortic insufficiency. The reoperations were performed in the 4 cases[29%] due to recurrent aortic insufficiency after aotic valvuloplasty. Two patients underwent aoritc valvular replacements for the tears of repaired aortic cusps after primary aortic valvuloplasty for aortic insufficiency. The other two patients had aortic valvuloplasties again. Death occured in one case of aortic valvular replacements. The cause of death was low cardiac output syndrome soon after aortic valvular replacement for recurrent aortic insufficiency .

  • PDF

CONSTRUCTION DEFECTS AND MONETARY RETENTIONS IN CONSTRUCTION PROJECT: A REVIEW OF CASE LAW

  • Priyanka Raina;John Tookey
    • International conference on construction engineering and project management
    • /
    • 2011.02a
    • /
    • pp.629-635
    • /
    • 2011
  • Retentions are generally considered to be intended to act as a powerful tool to incentivize contractors/subcontractors to remedy defective work in cases of non-performance. This study attempts to establish the extent to which retentions can be used for this purpose by investigating case law connected with insurance and defective work. One of the significant questions is whether retentions are sufficient to deal with construction defects or value of retentions in the rectification of defects is illusory. The cost to repair a defect may vary depending on a number of components including type, cause, magnitude and the construction stage at which the defect occurs. It is expected that a review of existing cases on defective workmanship will provide an insight on the issues and whether retentions are effective in their intended function. In order to establish their functionality, the study described in this paper investigated 6 construction insurance cases to identify the critical issues and the causes of dispute. It was found that the nature and the cause of defects were different in each case. It was also established that certain defect types not covered by insurance may be covered by retentions - potentially one of the key uses of a retention strategy. It is expected that the findings will assist in forming a view on the quantum of money that may be required paving the way for a first time understanding on a rational basis for setting up retention regime.

  • PDF

The study on cell Vth distibution induced by heavily doped channel ionn and Si-SiN stress in flash memory cell (과도한 채널 이온 주입 농도 및 Si-SiN 스트레스가 플래쉬 메모리셀 산포에 미치는 영향)

  • Lee Chi-Kyoung;Park Jung-Ho;Kim Han-Su;Park Kyu-Charn
    • Proceedings of the IEEK Conference
    • /
    • 2004.06b
    • /
    • pp.485-488
    • /
    • 2004
  • As scaling down the cell channel length, the increment of B concentration in channel region is inevitable to overcome the punch-through, especially in flash memory cell with 90nm technology. This paper shows that the high dose ion implantation in channel cause the Si defect. which has been proved to be the major cause of the tailed Vth in distribution. And also mechanical stress due to SiN-anneal process can induce the Si dislocation. and get worse it. With decreasing the channel implantation dose, skipping the anneal and reducing the mechanical stress, Si defect problem is solved completely. We are verify first that the optimization of B concentration in channel must be certainly considered in order to improve Si defect. It is also certainly necessary to stabilize the distribution of cell Vth in the next generation of flash memory.

  • PDF

Defect Detection of Wall Thinned Straight Pipe using Shearography and Lock-in Infrared Thermography (전단간섭계와 적외선열화상을 이용한 감육 직관의 결함검출)

  • Kim, Kyeong-Suk;Jung, Hyun-Chul;Chang, Ho-Seob;Kim, Ha-Sig;La, Sung-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.11
    • /
    • pp.55-61
    • /
    • 2009
  • The wall thinning defect of nuclear power pipe is mainly occurred by the affect of the flow accelerated corrosion (FAC) of fluid. This type of defect becomes the cause of damage or destruction of in carbon steel pipes. Therefore, it is very important to measure defect which is existed not only on the welding part but also on the whole field of pipe. This study use dual-beam Shearography, which can measure the out-of-plane deformation and the in-plane deformation by using another illuminated laser beam and simple image processing technique. And this study proposes Infrared thermography, which is a two-dimensional non-contact nondestructive evaluation that can detect internal defects from the thermal distribution by the inspection of infrared light radiated from the object surface. In this paper, defect of nuclear power pipe were, measured using dual-beam shearography and infrared thermography, quantitatively evaluated by the analysis of phase map and thermal image pattern.

Study on the Improvement Plans of Condensation Defect Examples in Apartment Building (공동주택 결로 하자 사례를 통한 개선방안 도출)

  • Oh, Se Min;Park, Sun Hyo;Joung, Kwang Sub
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.82-88
    • /
    • 2017
  • There are main issues of defect type that condensation, concrete crack and noise in apartment buildings. Especially, according to the Apartment Defect Dispute Mediation Committee in Korea (ADDMC) at Ministry of Land Infrastructure and Transport in Korea (MLIT), condensation defects are great importance (14 percent) on whole number of reported cases of faults from 2015 in Korea. Most condensation defects have many different causes that take a toll on the resident's life and space. So it is very important to early detection and repair. For preventing the condensation in apartment buildings, there are building codes in Korea such as 'Standard of Method and Judgment for Apartment defect of investigation, Repair cost Estimate'. This research aims to study on the improvement of preventing the condensation aforementioned korea standard. Types and characteristics (opaque wall, windows, doors) of cause of occurrence and existing state condensation defect is analyzed from evaluation of real application 100 case in 2015 ADDMC data.