• Title/Summary/Keyword: catheter ablation

Search Result 49, Processing Time 0.03 seconds

Mid-Term Results of Totally Thoracoscopic Ablation in Patients with Recurrent Atrial Fibrillation after Catheter Ablation

  • Lim, Suk Kyung;Kim, Joo Yeon;On, Young Keun;Jeong, Dong Seop
    • Journal of Chest Surgery
    • /
    • v.53 no.5
    • /
    • pp.270-276
    • /
    • 2020
  • Background: We investigated the impact of previous catheter ablation (CA) on the midterm outcomes of totally thoracoscopic ablation in patients with lone atrial fibrillation (AF). Methods: Between February 2012 and July 2018, 332 patients underwent totally thoracoscopic ablation for the treatment of AF (persistent AF; n=264, 80%). The patients were stratified into CA (n=47, 14%) and non-CA (nCA; n=285, 86%) groups according to their CA history. Results: All the baseline clinical characteristics and risk factors were similar between the groups except for age, percentage of male patients, prevalence of paroxysmal AF, prior percutaneous coronary intervention, and left atrial volume index (LAVI). No significant intergroup differences were observed in the incidence of early and late complications. At late follow-up, normal sinus rhythm was observed in 92% (43 of 47) of the patients in the CA group and 85% (242 of 285) of the patients in the nCA group (p=0.268). The rate of freedom from AF recurrence at 5 years was 55.3%±11.0% in the CA group, which was similar to that in the nCA group (55.7%±5.1%, p=0.690). In Cox regression analysis, preoperative brain natriuretic peptide levels and LAVI were associated with AF recurrence, but CA history was not significant. Conclusion: Totally thoracoscopic ablation was safe and effective in treating AF irrespective of CA history. A history of CA did not appear to affect the procedural complexity.

V-Y Latissimus Dorsi Musculocutaneous Flap for Reconstruction of Radiation-induced Skin Injuries on the Back (V-Y 광배근피판을 이용한 등의 방사선 유발 피부 손상의 치험)

  • Shim, Seung-Hyun;Chung, Chul-Hoon;Kim, Kuyl-Hee
    • Archives of Plastic Surgery
    • /
    • v.38 no.5
    • /
    • pp.707-710
    • /
    • 2011
  • Purpose: Cardiac radiofrequency catheter ablation procedures using fluoroscopy were performed for the treatment of supraventricular and selected ventricular tachyarrhythmia. Fluoroscopy is used to localize the position of the intracardiac catheter. Fluoroscopically-guided procedures often involve high radiation doses to patient's skin, but the incidence of serious radiation injuries in these patients is rare. We reported two cases of severe postradiation skin injury on the back treated with the V-Y latissimus dorsi musculocutaneous flap. Methods: These two patients underwent radiofrequency catheter ablation under the diagnosis of Woff Parkinson White syndrome (WPW syndrome). They had radiation-induced skin injuries on the subscapular area and these lesions represented chronic ulceration, surrounding induration, hardness, and dyspigmentation. We treated these lesions with complete excision and coverage with V-Y latissimus dorsi musculocutaneous flap. Results: These two patients had no recurrence and no special complications during 20 months and 12 months follow-up periods and were satisfied aesthetically and functionally. Conclusion: V-Y latissimus dorsi musculocutaneous flap obtained better results functionally and aesthetically compared with conservative management and skin graft in severe radiation-induced skin injuries after cardiac radiofrequency catheter ablation procedure.

Cryoballoon Catheter Ablation in Korean Patients With Paroxysmal and Persistent Atrial Fibrillation: One Year Outcome From the Cryo Global Registry

  • Hong Euy Lim;Il-Young Oh;Fred J Kueffer;Kelly Anna van Bragt;Young Keun On
    • Korean Circulation Journal
    • /
    • v.52 no.10
    • /
    • pp.755-767
    • /
    • 2022
  • Background and Objectives: Cryoballoon catheter ablation for the treatment of patients with symptomatic atrial fibrillation (AF) has been adopted globally, but there are limited multicenter reports of 12-month outcomes in the Korean patient population. This analysis evaluated the clinical performance and safety of cryoballoon ablation (CBA) according to standard-of-care practices in Korea. Methods: This evaluation of Korean patients with AF was conducted within the larger Cryo Global Registry, which is a prospective, multicenter, post-market registry. Freedom from a ≥30-second recurrence of atrial arrhythmias (after a 90-day blanking period until 12 months) and procedural safety were examined in subjects treated with CBA at 3 Korean centers. Results: Overall, 299 patients with AF (60±11 years old, 24.7% female, 50.5% paroxysmal AF) underwent CBA using the Arctic Front Advance cryoballoon. Of those, 298 were followed-up for at least 12 months. Mean procedure-, left atrial dwell- and fluoroscopy time was 76±21 minutes, 56±23 minutes, and 27±23 minutes, respectively. Freedom from AF recurrence at 12 months was 83.9% (95% confidence interval [CI], 76.9-88.9%) in the paroxysmal and 61.6% (95% CI, 53.1-69.0%) in the persistent AF cohort. Rhythm monitoring was performed on average 4.7±1.4 times during the follow-up period. Serious device- or procedure-related adverse events occurred in 2 patients (0.7%). The 12-month Kaplan-Meier estimate of freedom from repeat ablation and cardiovascular-related hospitalization was 93.8% (95% CI, 90.4-96.1%) and 89.7% (95% CI, 85.6-92.7%), respectively. Conclusions: CBA is an efficient, effective, and safe procedure for the treatment of AF patients when used according to real-world practices in Korea.

Radiofrequency catheter ablation of atrioventricular nodal reentry tachycardia in children and adolescents: a single center experience

  • Hyun, Myung Chul
    • Clinical and Experimental Pediatrics
    • /
    • v.60 no.12
    • /
    • pp.390-394
    • /
    • 2017
  • Purpose: Atrioventricular nodal reentry tachycardia (AVNRT) is less common in pediatric patients than in adult patients. Thus, data for pediatric AVNRT patients are insufficient. Hence, we aimed to analyze the patient characteristics, treatment, and any recurrences in pediatric AVNRT patients. Methods: We reviewed the records of 50 pediatric AVNRT patients who had undergone radiofrequency catheter ablation (RFCA) between January 1998 and December 2016 at a single regional center. The patients were aged ${\leq}18years$. Results: Among 190 pediatric patients who underwent RFCA for tachyarrhythmia, 50 (26.3%; mean age, $13.4{\pm}2.6years$) were diagnosed as having AVNRT by electrophysiological study. Twenty-five patients (25 of 50, 50%) were male. Twenty patients (20 of 50, 40%) used beta-blockers before RFCA. All patients had no structural heart disease except 1 patient with valvular aortic stenosis and coarctation of the aorta. RFCA was performed using the anatomic approach under fluoroscopic guidance. The most common successfully ablated region was the midseptal region (25 of 50, 50%). Slow pathway (SP) ablation and SP modulation were performed in 43 and 6 patients, respectively. Complication occurred in 1 patient with complete atrioventricular block. During follow-up, 6 patients had recurrence of supraventricular tachycardia, as confirmed by electrocardiography. Among them, 5 underwent successful ablation at the first procedure. In 1 patient, induction failed during the first procedure. Conclusion: RFCA is safe and effective in pediatric AVNRT patients. However, further research is needed for establishing the endpoints of ablation in pediatric AVNRT patients and for identifying risk factors by evaluating data on AVNRT recurrence after RFCA.

Surgical Treatment of the Wolff-Parkinson-White Syndrome (Wolff-Parkinson-White 증후군의 외과적 치료)

  • 박남희;이광숙
    • Journal of Chest Surgery
    • /
    • v.29 no.12
    • /
    • pp.1373-1376
    • /
    • 1996
  • From October 1993 to February 1996, 9 patients with Wolfr-Parkinson-White syndrome underwent surgical ablation of the accessory atrioventricular conduction pathways. The indications for surgical ablation we e radiofrequency ablation failure in 6 cases, multiple accessory pathways in 1 case, catheter tip fracture ducting catheter ablation in 1 case and additional procedure(redo mitral valve replacement due to valve thrombosis) in 1 case. There was no operative mortality. The postoperative complications were noted In 2 cases pericardial effusion and wound Infection. All patients had accessory atrioventricular connections ablated which were proven by surface ECG and follow-up electrophysiologic study and have remained free of symptomatic tachycardia. The indications for surgical treatment of Wolff-Parkinson-White syndrome are radiofrequency ablation failure, multiple pathways, or when additional procedures are required The present results were satisfactory.

  • PDF

Paradoxical Response of Giant Left Atrial Appendage Aneurysm after Catheter Ablation of Atrial Fibrillation

  • Chung, Jee Won;Shim, Jaemin;Shim, Wan Joo;Kim, Young-Hoon;Hwang, Sung Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.2
    • /
    • pp.132-135
    • /
    • 2016
  • We report the case of a 43-year-old male with both giant left atrial appendage (LAA) aneurysm and drug-refractory atrial fibrillation (AF). The patient was treated with percutaneous electrical isolation of cardiac arrhythmogenic substrate, and has been free of AF symptom over one year. Although the surgical resection of giant LAA aneurysm is mostly used to prevent systemic thromboembolism, we have performed follow-up of the giant LAA aneurysm using cardiac magnetic resonance (CMR) imaging and transesophageal echocardiography (TEE) after the successful catheter ablation of refractory AF. At one-year follow-up CMR, the giant LAA aneurysm showed remarkable enlargement as well as decreased contractility. Additionally, one-year follow-up TEE showed spontaneous echo contrast as an indicator of blood stasis in the giant LAA aneurysm. Those findings of giant LAA aneurysm suggest that the risk of thromboembolism may be high despite termination of AF.

Development of Master-Slave Type Tele-Operation Control Robotic System for Arrhythmia Ablation (부정맥 시술을 위한 마스터-슬레이브 원격제어·로봇 시스템 개발)

  • Moon, Youngjin;Park, Sang Hoon;Hu, Zhenkai;Choi, Jaesoon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.8
    • /
    • pp.585-589
    • /
    • 2016
  • Recently, the robotic assist system for cardiovascular intervention gets continuously growing interest. The robotic cardiovascular intervention systems are largely two folds, systems for cardiac ablation procedure assist and systems for vascular intervention assist. For the systems, the clinician controls the catheter inserted through blood vessel to the heart via a master console or master manipulator. Most of the current master manipulators have structure of joystick-like pivoting 2 degree of freedom (DOF) handle in the core, which is used in parallel with other sliding switches and input devices. It however is desirable to have customized and optimized design manipulator that can provide clinician with intuitive control of the catheter motion fully utilizing the advantage of the use of robotic structure. A 6 DOF kinematic mechanism that can capture the motion control intention of the clinician in translational 3 DOF and rotational 3 DOF is proposed in this paper. Also, a master-slave motion relationship specially designed for the cardiac catheter manipulation motion is proposed and implemented in an experimental prototype. Design revision for implementation of more efficient motion and experiment in combination with an experimental slave robot system for catheter manipulation are underway.

Pulmonary Vein to Esophageal Fistula after Staged Hybrid Totally Thoracoscopic Surgical and Percutaneous Radiofrequency Catheter Ablation: A Case Report

  • Park, Byung-Jo;Kim, Yong Han;Jeong, Dong Seop;Choi, Yong Soo;On, Young Keun
    • Journal of Chest Surgery
    • /
    • v.47 no.6
    • /
    • pp.560-562
    • /
    • 2014
  • A case of a fistula running from the pulmonary vein to the esophagus after a staged hybrid procedure combining total thoracoscopic ablation and percutaneous radiofrequency catheter ablation has not been reported previously. We describe such a case in a 37-year-old man who was successfully treated by surgery.