• 제목/요약/키워드: cast-in-place system

검색결과 76건 처리시간 0.031초

타설형 콘크리트 중단열 벽체의 요구성능 분석 (Performance Requirement of Cast-in-place Concrete with Sandwich Insulation)

  • 박준호;유정호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.10-11
    • /
    • 2014
  • Energy load of building affected by insulation performance of building's exterior. and insulation system can be classify interior insulation, exterior insulation, sandwich insulation according to install place of insulation. but within interior insulation system, corner wall and the cross outer wall-slab insulation part may occur thermal bridges. And then, within exterior insulation system is more superior insulation performance than interior insulation, but it has difficult to apply, easily broken at high building because of strong wind load. And also difficult to maintenance exterior insulation system. So, in this study, to found requirement performance of cast-in-place sandwich insulation system that is superior insulation performance and easy construction and maintenance. requirement performance of cast-in-place sandwich insulation system is 1) To avoid thermal bridges in the insulation performance, 2) Both sides concrete wall can be composite action in the structural performance. Because of this study, can develops cast-in-place sandwich insulation system and this insulation system contribute to improve insulation performance of apartment-house and high building.

  • PDF

STUDY OF NEW CAST-IN-PLACE MORTAR WALL FOR HOUSE CONSTRUCTION COMPARED TO BRICK AND MORTAR-BLOCK SYSTEM (A SIMULATION IN DIFFERENT AREAS)

  • Arief Setiawan Budi Nugroho;Shin-ei Takano
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.196-202
    • /
    • 2009
  • Study from Yogyakarta earthquake reconstruction program, cast-in-place wall using fix-size formwork system (Old-CIP) has offered a good alternative for house construction. A simulation has also confirmed that this system using mortar as the main material can provide cheapest cost and lowest total man power compared to conventional wall construction technique: brick or mortar-block wall. This paper presents the new wall construction technique: full size cast-in-place wall (New-CIP). The detail of how this new technique implemented is described. In addition, considering that material and labor cost in one area is different to others, cost analysis for different resources prices and wages of three cities are taken into a simulation. The analysis is aimed to distinguish the implementation feasibility of New-CIP system compared to the four common wall systems. Finally, its implementation resistance is also discussed.

  • PDF

수치해석에 의한 직매형 앵커기초의 인장 설계기준 평가 (Tensile Design Criteria Evaluation of Cast-In-Place Anchor by Numerical Analysis)

  • 장정범;서용표;이종림
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 봄 학술발표회 논문집
    • /
    • pp.209-216
    • /
    • 2004
  • Numerical analysis is carried out to identify the appropriateness of the design codes that is available for the tensile design of fastening system at Nuclear Power Plant (NPP) in this study. This study is intended for the cast-in-place anchor that is widely used for the fastening of equipment in Korean NPPs. The microplane model and the elastic-perfectly plastic model are employed for the quasi-brittle material like concrete and for the ductile material like anchor bolt as constitutive model for numerical analysis and smeared crack model is employed for the crack and damage phenomena. The developed numerical model is verified on a basis of the various test data of cast-in-place anchor. The appropriateness of both ACI 349 Code and CCD approach of CEB-FIP Code is evaluated for the tensile design of cast-in-place anchor and it is proved that both design codes give a conservative results compared with real tensile capacity of cast-in-place anchor.

  • PDF

현장타설 말뚝 공법의 지반진동이 정밀장비에 미치는 영향성 평가 (The Study on The Evaluation of The Ground Vibration of Cast in Place Concrete Pile Method Effect to Precision Equipment)

  • 홍병국;김영찬;장강석;윤제원;심상덕
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.97-102
    • /
    • 2011
  • The size of TV and TFT-LCD are bigger and bigger for the next generation exposure equipment install that existing fab are getting a lot of additions. When the new fab build an extension that the shortening of the construction and non-vibration are use cast in place concrete pile method. In this study when lay the foundation of existing fab adjoin use vibration monitoring system are rotator type all casing method among cast in place concrete pile method. The evaluation of ground vibration of rotator type all casing method effect to precision equipment and vibration area of influence.

  • PDF

현장타설형 건물 기초를 이용한 지중열 공조시스템의 성능평가에 관한 연구 (A Study on Development of a Ground-Source Heat Pump System Utilizing Cast-in-place Concrete Pile Foundation of a Building)

  • 황석호;남유진
    • 설비공학논문집
    • /
    • 제22권9호
    • /
    • pp.641-647
    • /
    • 2010
  • Ground-source(Geothermal) heat pump(GSHP) systems can achieve a higher coefficient of performance than conventional air-source heat pump(ASHP) systems. However, GSHP systems are not widespread because of their expensive installation costs. The authors have developed a GSHP system that employs the cast-in-place concrete pile foundations of a building as heat exchangers in order to reduce the initial cost. In this system, eight U-tubes are arranged around the surface of a cast-in-place concrete pile foundation. The heat exchange capability of this system, subterranean temperature changes and heat pump performance were investigated in a full-scale experiment. As a result, the average values for heat rejection were 186~201 W/m(per pile, 25 W/m per pair of tubes) while cooling. The average COP of this system was 4.6 while cooling; rendering this system more effective in energy saving terms than the typical ASHP systems.

현장 타설 에너지파일을 적용한 지열 히트펌프 시스템의 성능 예측 (Performance Prediction of Geothermal Heat Pump(GHP) System Using Cast-in-Place Energy Piles)

  • 손병후;정경식;최항석
    • 설비공학논문집
    • /
    • 제25권1호
    • /
    • pp.28-36
    • /
    • 2013
  • The aim of this study is to evaluate the performance of the GHP system with 45 cast-in-place energy piles(CEP) for a commercial building. In order to demonstrate the feasibility of a sustainable performance of the system, transient simulations were conducted over 1-year and 20-year periods, respectively. The 1-year simulation results showed that the maximum and minimum temperatures of brine returning from the CEPs were $23.91^{\circ}C$ and $6.66^{\circ}C$, which were in a range of design target temperatures. In addition, after 20 years' operation, these returning temperatures decreased to $21.24^{\circ}C$ and $3.68^{\circ}C$, and finally reached to stable state. Annual average extraction heat of cast-in-place energy piles was 94.3 MWh and injection heat was 65.7 MWh from the 20 years of simulation results. Finally, it is expected this GHP system can operate with average heating SPF of more than 3.45 for long-term.

공동주택용 외단열 동시타설 공법 적용을 위한 리스크 요인 평가 (Assessment of Risk Factors for Application of Exterior Insulation Board in Cast-in-place Concrete Form System for Apartment)

  • ;김태훈;임현수;조훈희;강경인
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.204-205
    • /
    • 2015
  • Exterior insulation board in cast-in-place concrete form system could reduce construction period and improve quality in apartment construction. However, the method is progressed with insulation and concrete frame works at the same time, then risk is increased in duration control and quality management. Therefore, this paper analyzed risk factors through FMEA method. We found that the key risk factors delaying schedule was insulation material that soaked in the rain and quality defects on the insulation material joint. Based on this research, the risk management approach should be developed for improvement of method activation.

  • PDF

수치해석에 의한 직매형 앵커기초의 인장설계기준 평가 (An Evaluation of Tensile Design Criteria of Cast-In-Place Anchor by Numerical Analysis)

  • 서용표;장정범
    • 한국전산구조공학회논문집
    • /
    • 제18권3호
    • /
    • pp.303-309
    • /
    • 2005
  • 본 연구에서는 국내 원전에서 기기 정착을 위하여 가장 널리 적용되는 직매형 앵커기초를 대상으로 앵커기초의 인장 설계기준에 대한 적정성을 검토하기 위하여 수치해석이 수행되었다. 본 연구에서 수치해석모형에 적용된 파괴기준으로서 콘크리트와 같은 유사 취성재료에는 Microplane모형이, 앵커볼트와 같은 연성재료에는 탄성-완전 소성모형이 적용되었다. 그리고, 균열 발생현상을 모사하기 위하여 분산균열모형을 채택하였다. 개발된 수치해석모형은 다양한 경우의 실증시험결과를 근거로 신뢰성이 검증되었으며, 검증된 수치해석모형과 앵커볼트의 유효매입깊이를 변수로 한 다양한 경우에 대한 수치해석을 통하여 직매형 앵커기초의 인장설계기준으로서 적용이 가능한 ACI 349 Code와 CEB-FIP Code가 평가되었고, 그 보수성이 확인되었다.

건물 기초를 이용한 지중열 공조시스템의 개발에 관한 연구 (1) (A Study on Development of a Ground-Source Heat Pump System Utilizing Pile Foundation of a Building)

  • 오오카 료죠;남유진;세키네 켄타로;요코이 무츠미;시바 요시로;황석호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.148-154
    • /
    • 2005
  • Ground-source (Geothermal) heat pump (GSHP) systems can achieve a higher coefficient of performance than conventional air-source heat pump (ASHP) systems. However, GSHP systems are not widespread in Japan because of their expensive boring costs. The authors have developed a GSHP system that employs the cast-in-place concrete pile foundations of a building as heat exchangers in order to reduce the initial boring cost. In this system, eight U-tubes are arranged around the surface of a cast-in-place concrete pile foundation. The heat exchange capability of this system, subterranean temperature changes and heat pump performance were investigated in a foil-scale experiment. As a result, the average values for heat rejection were 186${\sim}$201 W/m (for pile, 25 W/m per Pair of tubes) while cooling. The average COP of this system was 4.6 while cooling; rendering this system more effective in energy saving terms than the typical ASHP systems. The initial cost of construction per unit for heat extraction and rejection is ${\yen}$72/W for this system, whereas it is f300/W for existing standard borehole systems.

  • PDF

프리캐스트 콘크리트 패널 분절 아치 시공을 위한 선설치 앵커의 인발 강도 평가 (Pull-out Capacity of Cast-in-place Anchor for Construction of Precast Concrete Segment Arch)

  • 안진희;임홍재;방진수;전석현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권2호
    • /
    • pp.94-102
    • /
    • 2020
  • 프리캐스트 콘크리트의 장점과 및 석조 아치의 거동을 접목한 콘크리트 패널 분절 아치 시스템은 가설재가 불필요한 시공성을 확보할 수 있는 경제적 시공법이다. 분절된 프리캐스트 콘크리트 패널의 연속 배치로 구성된 아치는 인양 및 시공을 위한 V형-스트립 연결부의 선설치 앵커 설치가 필수적이다. 그러나 좁은 폭과 얇은 두께의 콘크리트 패널은 선설치 앵커의 충분한 묻힘 깊이 확보를 보장할 수 없고 앵커 인발 거동 시 패널의 휨변형을 동반하는 등 앵커 저항성능 확보를 위한 콘크리트 패널의 기하학적 영향이 고려되어야 한다. 따라서 본 연구에서는 프리캐스트 패널과 강재 아웃리거로 구성된 아치구조의 제작시 설치되는 선설치 앵커의 인발 강도 평가를 위한 실험 연구를 수행하였다. 이를 위해 실제 아치 시스템과 동일한 크기의 프리캐스트 콘크리트 패널을 제작하였으며, 선설 앵커의 직경, 앵커 묻힘 깊이, 와이어 매쉬 사용 등의 영향에 따라 총 24개 실험체의 선설치 앵커 인발 강도를 측정하였다. 또한 측정 변수에 따른 설계기준강도 확보 및 파괴 모드 평가를 통해 프리캐스트 콘크리트 패널 분절 아치 구조에 적용 가능한 선설치 앵커의 형태를 결정하였다.