• 제목/요약/키워드: cascade impactor

검색결과 104건 처리시간 0.024초

국내공정시험기준과 ISO 방법을 이용한 고정오염원 미세먼지 (PM10, PM2.5) 측정 방법 및 입경분율 비교: 석탄화력발전소, 석유정제시설 중심으로 (Comparison of Measurement Methods and Size Fraction of Fine Particles (PM10, PM2.5) from Stationary Emission Source Using Korean Standard and ISO: Coal Power Plant and Refinery)

  • 윤종상;한세현;정용원;전기준
    • 한국대기환경학회지
    • /
    • 제33권4호
    • /
    • pp.342-350
    • /
    • 2017
  • We report mass concentration and size fraction of TPM, $PM_{10}$ and $PM_{2.5}$ according to Korea standard test method (ES 01301.1 and ES 01317.1) and ISO 23210 methods. Particulate matters were sampled in large stationary emission sources such as a coal power plant and B-C oil refinery. The Korea standard test method PM mass concentrations showed 3~3.5 times larger than the cascade impactor method. On the other hand, the size fraction results showed less than 5% difference (i.e. $PM_{2.5}/PM_{10}$) between two methods. Moreover, the correlation coefficient ($r^2$) is 0.84 between TPM results of the Korea standard test method and CleanSYS. These results suggested not only improvement of current test criteria in terms of technical and theoretical aspects. Further, additional measurements are required in various large stationary sources to compare current field data.

Hood Method를 이용한 직화구이 음식점의 미세먼지 배출 특성 (Emission Characteristics of Particulate Matters from Under-fired Charbroiling Cooking Process using the Hood Method)

  • 이준복;김흥주;정권;김신도
    • 한국환경보건학회지
    • /
    • 제35권4호
    • /
    • pp.315-321
    • /
    • 2009
  • Under-fired charbroiling cooking processes are known as important contributors of particulate matter (PM). In this study, we characterized the emission of particulate matters from under-fired charbroiling cooking processes using the hood method. Accumulated mass concentration of $PM_{10}$ was 92.2~99.5% and particle size of 2.0~2.5 ${\mu}m$ was highest. The concentration of PM increased very sharply at the beginning of charbroiling meats and then gradually decreased as the charbroiling continued. PM concentration also increased very sharply when gravy from meat spilled onto the frame of fire. However, mass concentration during charbroiling using only charcoals was very low compared to that of meats. We estimated the emission factors of charcoal, pork belly and pork shoulder respectively; 0.01~0.02 g/kg, 5.02~6.26 g/kg, 2.86~4.15 g/kg of $PM_{2.5}$, 0.01~0.03 g/kg, 7.44~7.91 g/kg, 4.54~5.56 g/kg of $PM_{10}$, and 0.02~0.05 g/kg, 7.59~7.95 g/kg, 4.93~5.68 g/kg of TSP. The emission factors of charcoal were negligible and the emission factors of pork belly were higher than that of pork shoulder. Emission rates of particulate matters from under-fired charbroiling cooking process were estimated as 578,009~1,265,152 kg/yr of $PM_{2.5}$, 917,539~1,598,619 kg/yr of $PM_{10}$ and 996.358~1,606,703 kg/yr of TSP. But emission factors should be verified with an in-stack cascade impactor because the reported method involves some assumptions.

2016년 한국 경기도의 3월 황사기간 동안 부유세균 군집과 다양성에 대한 메타지노믹 분석 (Metagenomic Analysis of Airborne Bacteria Community and Diversity in Gyeonggi-do, Korea, during March 2016, Asian Dust Event)

  • 장준형;김지혜;배경선;김정명;이원석;정현미;박상정;서태근
    • 한국환경보건학회지
    • /
    • 제43권6호
    • /
    • pp.491-498
    • /
    • 2017
  • Objective: Bacterial abundance and community compositions have been examined in Asian dust events, clarifying their impacts on public health. This study aims to determine the bacterial community compositions and viable bacteria in Asian dust particles in the Asian dust or non-Asian dust event of March 2016. Methods: The dust samples were collected using the high volume air sampler or high volume cascade impactor, and bacterial 16S rRNA genes were amplified using PCR, followed by pyrosequencing. Bacterial diversity index, richness estimate and community composition in the particles were analyzed from the sequencing data using Mothur software. Results: The results showed that the diversity and richness during Asian dust events were higher than them in non-Asian dust events. The total bacterial community analysis showed that at the phylum Proteobacteria, Actinobacteria and Firmicutes were the most dominant of Asian dust events and non-Asian dust events. In addition, the bacterial colony counts were higher during Asian dust event, comparing with non-Asian dust event. Conclusions: This study showed that bacterial community and richness of Asian dust samples was more complex and higher than non-Asian dust samples in Gyeonggi-do, Korea, which could affect public health and environment. Thus, the continuous monitoring of Asian dust could be an alternative for managing airborne bacteria.

종합병원의 실내공기에 분포하는 부유 세균과 진균의 입경별 종류와 특성 (Size-based Characteristics of Airborne Bacteria and Fungi Distributed in the General Hospital)

  • 김기연;이창래;김치년;원종욱;노재훈
    • 한국산업보건학회지
    • /
    • 제16권2호
    • /
    • pp.101-109
    • /
    • 2006
  • The objective of this study is to provide fundamental data for pertinent management of indoor air quality through investigating the size-based characteristics of bioaerosol distributed in the general hospital. Measurement sites are main lobby, ICU, ward and laboratory and total five times were sampled with six-stage cascade impactor. Based on the result of this study, concentrations of airborne bacteria and fungi were the highest in main lobby as followed by an order of ward, ICU and laboratory. Concentrations of airborne bacteria was generally higher than those of airborne fungi and the ratio of indoor and outdoor concentration of both exceeded 1.0 in all the measurement sites of the general hospital. The predominant genera of airborne bacteria identified in the general hospital were Staphylococcus spp.(50%), Micrococcus spp.(15-20%), Corynebacterium spp.(5-20%), and Bacillus spp.(5-15%). On the other hand, the predominant genera of airborne fungi identified in the general hospital were Cladosporium spp.(30%), Penicillium spp.(20-25%), Aspergillus spp.(15-20%), and Alternaria spp.(10-20%). In regard to size distribution of bioaerosol, the detection rate was generally highest on 5 stage($1.1-2.1{\mu}m$) for airborne bacteria and on 1 stage(>$7.0{\mu}m$) for airborne fungi. Cleanliness of facilities in the general hospital and condition of HVAC system should be monitored regularly to prevent indoor air contamination by airborne microorganisms.

공중화분에 의한 시정장애 현상의 물리적 및 화학적 특성 규명 (Physico-Chemical Characteristics of Visibility Impairment by Airborne Pollen)

  • 김경원
    • 한국대기환경학회지
    • /
    • 제22권6호
    • /
    • pp.863-875
    • /
    • 2006
  • Intensive visibility monitoring was conducted to investigate physical and chemical characteristics of visibility impairment by airborne pollen. Light attenuation coefficients were optically measured by a transmissometer, a nephelometer, and an aethalometer. Elemental, ionic, and carbonaceous species were chemically analyzed on the filters collected by $PM_{2.5}$ and $PM_{10}$ samplers. Aerosol size distribution was analyzed using a cascade impactor during airborne pollen period. Airborne pollen count was calculated using a scanning electron microscope. Airborne pollen was emitted into the atmosphere in springtime and funker degraded visibility through its scattering and absorbing the light. Average light extinction coefficient was measured to be $211{\pm}36Mm^{-1}$ when airborne pollen was not observed. But it increased to $459{\pm}267Mm^{-1}$ during the airborne pollen period due to increase of average $PM_{2.5}$ and $PM_{10}$ mass concentration and relative humidity and airborne pollen count concentration for $PM_{10}$, which were measured to be $46.5{\pm}29.1{\mu}g\;m^{-3},\;97.0{\pm}41.7{\mu}g\;m^{-3},\;54.1{\pm}11.6%$, and $68.2{\pm}89.7m^{-3}$, respectively. Average light extinction efficiencies for $PM_{2.5}$ and $PM_{10}$ were calculated to be $5.9{\pm}0.9$ and $4.5{\pm}0.8m^2 g^{-1}$ during the airborne pollen period. Light extinction efficiency for $PM_{10}$ increased further than that for $PM_{2.5}$. The average light extinction budget by airborne pollen was estimated to be about 24% out of the average measured light extinction coefficient during the airborne pollen period.

서울시 대기부유분진의 농도와 다환방향족 유기물질에 의한 발암 위해성 (Airborne Suspended Particulates Concentration and Cancer Risk Assessment of Polycyclic organic matter in Seoul)

  • 박성은;정용
    • 한국대기환경학회지
    • /
    • 제8권4호
    • /
    • pp.247-256
    • /
    • 1992
  • Airborne suspended particulates were collected at Shinchon by a high volume cascade impactor from Sep. 1990 to Aug. 1991. Organic matter was extracted from particulates and fractionated by liquid-liquid extraction and thin layer chromatography. Substances in the PAHs and nitroarenes'subfraction of neutral fraction were determined by capillary gas chromatography. Based on unit risk estimates by multi-stage model of benzo[a]pyrene and the results of exposure estimates, cancer risk was assessed. The annual average concentration of total suspended particulates was 201.77g/$m^3$. The percentage of fine particulates was 57.40. The concentration of total suspended particulates showed seasonal variations and was high in winter and spring. The average concentration of extractable organic matter was 8.12g/$m^3$. In all, 21 PAHs were identified and quantified. The annual concentration of fluoranthene was 2.38ng/$m^3$, and that was the highest value of all PAHs. A carcinogenic compound, benzo[a]pyrene, was at a concentration of 1.84ng/$m^3$. All the 10 nitroarenes were also identified and quantified. The major nitroarene in the Shinchon area was 2,7-dinitrofluorene. The annual concentration of 1-nitropyrene was 1.56ng/$m^3$. Concentrations of PAHs and nitroarenes were high in winter and low in summer. The life time excess risk estimates of benzo[a]pyrene was calculated as 0.96 persons/a million population in this experiment. In the rank of relative potenties, carcinogenic effects of the other PAHs were calculated as 0.004-0.108 persons/a million population.

  • PDF

제주시 대기부유부진 중 수용성 이온성분의 입경별 분포특성 (Size Distribution of Water-Soluble Ionic Components in the Atmospheric Aerosols Collected in Jeju City, Korea)

  • 허철구;송정화;이기호
    • 한국환경과학회지
    • /
    • 제13권12호
    • /
    • pp.1067-1078
    • /
    • 2004
  • Atmospheric particulate matters were collected by 8-stage non viable cascade impactor from October 2002 to August at Jeju City. Eight water-soluble ionic components $(Na^+,\;NH_{4}_{+},\;K^+,\;Ca{2+},\;Mg^{2+},\;CI^-,\;NO_{3}^-\;and\;SO_{4}^{2-})$ were analyzed by Ion Chromatography. The concentration of particulate matters and eight water-soluble ionic components were determined to investigate their size distributions. Particulate matters exhibited a tri-modal distribution with peak value around $0.9,\;4.0{\mu}m\;and\;9.5{\mu}m.$ In summer, the last peak value was lower than other season values likely due to particulate matter scavenged by rain water. Four ionic components $(Na^+,\;Ca^{2+},\;Mg^{2+}\;and\;CI^-)$ exhibited a bi-modal distribution in the coarse mode whereas three ionic components $(NH_{4}^+,\;K^+\;and\;SO_{4}^{2-})$ in the fine mode, with maximum peak value around $0.9{\mu}m.\;NO_{3}^-$ was found in both the coarse and the fine mode. The enrichment factor (E.F.) of each ionic components was calculated. Based upon E.F., it is considered that $Na^+,\;CI^-,\;and\;K^+$ in coarse paricle mode were delivered form oceanic source, but other components might have other source origins.

대기 중 다환방향족 탄화수소류의 오염도 변화 특성 (Variations and Trends in Concentrations of Polycyclic Aromatic Hydrocarbons (PAHs) in Air)

  • 정용;박성은;황만식;홍지연
    • Environmental Analysis Health and Toxicology
    • /
    • 제13권1_2호
    • /
    • pp.43-53
    • /
    • 1998
  • Ambient air levels of polycyclic aromatic hydrocarbons(PAHs) are of concern because of their potential for adverse health effects including transformation of some of these substances to mutagens and carcinogens by mammalian microsomal enzyme system. Airbone particulate samples were collected by a conventional high-volume sampler and by an Anderson cascade impactor on 2 to 3 days in each month over a period of 1 year at a representative site of the heavy traffic area of Seoul from beptember 1994 to August 1995. Ten individual PAHs in sizable air particulates of each stage of two months were separated and analyzed by gas chromatography/mass spectrometry. As a results of analysis, the gross concentrations of PAHs in the fine and coarse particles were higher in the winter month than in the spring, followed in descending order by in the fall and summer. In a study of dependency of 10 PAHs compounds on size distribution of particles at heavy traffic area found that about 85% of the total PAHs content was associated with particles less than 2.0um (fine particles) in diameter of winter sampling period. while 79% were associated with this size fraction during summer period. In according to the mean concentrations of the 10 PAHs in 7 size classification from < 0.38 to> 10.1, the 'size was the smaller, PAHs concentration was the higher. Thus it was found that PAHs concentration was greatly affected by air particle size. Annual mean benzo(a)pyrene equivalents was 5.88ng/m$^3$ and obtained by applying, toxic equivalency factor developed by Nisbet and Lagoy.

  • PDF

2006 ~ 2008년 황사기간 중 천안시 대기 입자의 특성 변화 (Changes in aerosol characteristics during 2006 ~ 2008 Asian dust events in Cheonan, Korea)

  • 오세원
    • 한국산학기술학회논문지
    • /
    • 제10권7호
    • /
    • pp.1642-1647
    • /
    • 2009
  • 황사기간 중 천안시 대기 입자의 특성 변화를 파악하기 위해, Cascade Impactor를 장착한 High Volume Air Sampler를 이용하여 대기 시료를 채취하여, 대기 입자의 입경별 질량농도 및 이온, 금속 성분의 농도를 황사기간과 비황사기간에 비교 측정하였다. 황사기간 중 일평균 TSP, PM10, PM2.5 평균 농도가 각각 214.9, 160.3, 95.9${\mu}\;g/m^3$으로, 비황사기간에 비해 각각 평균 3.08, 2.58, 1.95배 증가하였으며, 최대 농도는 TSP, PM10, PM2.5가 각각 850.1, 534.4, 233.3${\mu}\;g/m^3$으로, 비황사기간에 비해 각각 12.19, 8.60, 4.76배까지 증가하였다. 황사기간 중 농도의 증가는 미세입자보다는 조대입자에서 현저하였으며, 미세입자와 조대입자 모두 수용성 이온성분의 증가는 미미한 반면, 토양의 주요 구성 성분인 Fe, Al, Ti의 증가가 뚜렷이 관측되어, 토양구성 금속성분이 황사기간 중 입자 농도 증가의 주요원인 물질임을 확인할 수 있었다.

서울시 일부 지하철역 내 부유 진균, 입자상 물질, 이산화탄소의 분포 양상 (Distribution of Airborne Fungi, Particulate Matter and Carbon Dioxide in Seoul Metropolitan Subway Stations)

  • 김기연;박재범;김치년;이경종
    • Journal of Preventive Medicine and Public Health
    • /
    • 제39권4호
    • /
    • pp.325-330
    • /
    • 2006
  • Objectives: The aims of this study were to examine the level of airborne fungi and environmental factors in Seoul metropolitan subway stations and to provide fundamental data to protect the health of subway workers and passengers. Methods: The field survey was performed from November in 2004 to February in 2005. A total 22 subway stations located at Seoul subway lines 1-4 were randomly selected. The measurement points were subway workers' activity areas (station office, bedroom, ticket office and driver's seat) and the passengers' activity areas (station precincts, inside train and platform). Air sampling for collecting airborne fungi was carried out using a one-stage cascade impactor. The PM and CO2 were measured using an electronic direct recorder and detecting tube, respectively. Results: In the activity areas of the subway workers and passengers, the mean concentrations of airborne fungi were relatively higher in the workers' bedroom and station precinct whereas the concentration of particulate matter, $PM_{10}\;and\;PM_{2.5}$, were relatively higher in the platform, inside the train and driver's seat than in the other activity areas. There was no significant difference in the concentration of airborne fungi between the underground and ground activity areas of the subway. The mean $PM_{10}\;and\;PM_{2.5}$ concentration in the platform located at underground was significantly higher than that of the ground (p<0.05). Conclusions: The levels of airborne fungi in the Seoul subway line 1-4 were not serious enough to cause respiratory disease in subway workers and passengers. This indicates that there is little correlation between airborne fungi and particulate matter.