• 제목/요약/키워드: cascade effect

검색결과 259건 처리시간 0.019초

대체 프레온계 냉매를 이용하는 이원 냉동시스템의 성능예측 (Prediction on Performance of Cascade Refrigeration System using Alternative Freon Refrigerants)

  • 노건상
    • 한국기계기술학회지
    • /
    • 제13권1호
    • /
    • pp.73-79
    • /
    • 2011
  • In this paper, cycle performance analysis of cascade refrigeration system using alternative FREON refrigerants are presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooled and superheated degree, and evaporating and condensing temperature, temperature difference of cascade heat exchanger in cascade refrigeration system. The COP of cascade refrigeration system increases with the increasing subcooled degree, but there is no significant changes with the increasing superheated degree. The COP of cascade refrigeration system depends on evaporating and condensing temperatures of cascade heat exchanger. Therefore, subcooled degree, evaporating and condensing temperature of cascade heat exchanger using alternative FREON refrigerants have an effect on the COP of this system. In this paper, COP of cascade refrigeration system using R23 for low temperature system and R507A for high temperature system is higher 8 ~ 29 % than using R13 for low temperature system and R22 for high temperature system.

다단계 p-cycle Cascade 생성기의 분석

  • 이상진;박상준;고승철
    • 정보보호학회지
    • /
    • 제5권2호
    • /
    • pp.90-96
    • /
    • 1995
  • Gollmann이 제안한 Cascade 생성기는 비선형성, 발생되는 수열의 난수특성, 주기성등 암호 알고리즘으로서 필요한 제반 특성을 보장하기 때문에 그동안 스트림 암호의 핵심 논리로 널리 사용되어 왔다. 그러나 최근 생성기 내부의 각 단계별로 시각 제어 수열과 출력 수열 사이에 암호 알고리즘으로는 부적당한 상관관계 특성이 존재함이 입증되었다. 본 고에서는 이러한 상관관계 특성을 이용하여,. 단순 순환 쉬프트 래지스터로 구성된 Cascade 생성기에 대한 기지 평문 공격 방식을 제안한다. 기존의 Lock-in effect 공격방식에 대하여 $10^{21}$ 정도의 안전성을 보장하는 8단계 11-cycle Cascade 생성기에 본 방식을 적용한 결과 불과 88,000 출력 비트만을 사용하여 공격이 성공함을 실험적으로 입증하였다.

  • PDF

내부 열교환기 부착 R744-R404A용 캐스케이드 냉동시스템의 성능 분석 (Performance analysis of a R744 and R404A cascade refrigeration system with internal heat exchanger)

  • 오후규;손창효
    • 동력기계공학회지
    • /
    • 제16권1호
    • /
    • pp.38-43
    • /
    • 2012
  • This paper describes an analysis on performance of R744-R404A cascade refrigeration system with internal heat exchanger to optimize the design for the operating parameters of the system. The operating parameters considered in this study include subcooling and superheating degree, internal heat exchanger and compression efficiency, evaporating and condensing temperature in the R744 low- and R404A high-temperature cycle and temperature difference of cascade heat exchanger. The main results are summarized as follows : COP of cascade refrigeration system increases with the increasing of compression efficiency, but decreases with the increasing temperature difference of cascade heat exchanger. Also, the COP increases with the increasing of internal heat exchanger efficiency in high-temperature cycle, but decreases with that in low-temperature cycle. Therefore, internal heat exchanger efficiency, compressor efficiency and temperature difference of cascade heat exchanger on R744-R404A cascade refrigeration system have an effect on the COP of this system.

축류압축기 익렬에서의 역류 유동 특성에 대한 수치적 연구 (Numerical Study on Reverse Flow Charcteristics in an Axial Compressor Cascade)

  • 손창현
    • 대한기계학회논문집B
    • /
    • 제24권5호
    • /
    • pp.615-622
    • /
    • 2000
  • Numerical simulation is performed with Denton's code to get pressure loss coefficients in wide range of reverse flow incidence(from -90 degree to +85 degree) for an axial compressor cascade. As a results, it is found that the pressure loss coefficient is increased with incidence and there exist critical incidence which corresponds to the maximum pressure loss coefficient. Pressure loss coefficient with bigger incidence than its critical value is decreased. The effect of increasing incidence in a cascade extremely reduce the mass flow rate by the large flow separation region. Consequently this effect reduce the portion of dynamic pressure in the total pressure loss and beyond the critical incidence the pressure loss coefficient decrease.

캐스케이드 열펌프의 저단 사이클 충전량 변화에 따른 성능 특성 (Influence of Low Stage Refrigerant Charge Amount on the Performance of Cascade Heat Pump)

  • 박승병;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제11권1호
    • /
    • pp.15-20
    • /
    • 2015
  • In this study, the optimization and performance characteristics of a cascade heat pump system was analyzed with the variation of low stage refrigerant charge amount. The cascade heat pump was designed and constructed with R134a and R410A as the refrigerant for high stage and low stage cycle, respectively. Experiments were conducted by varying the low stage charge amount and the performance characteristics of the cascade heat pump were studied. The refrigerant charge amount of the low stage cycle was varied between the ranges of -15% and +10% of the optimum charge amount. The performance variation experienced in the cascade heat pump due to the variation of refrigerant charge amount shows greater effect in the undercharge regions than the overcharge regions. COP reduction in the undercharge region is larger than the decrease in the overcharge region. Some cycle variation such as power consumption and cycle pressure according to low stage refrigerant charge amount showed different trends comparing with those according to high stage refrrgerant charge amount. Therefore, the optimum charge amount of the cascade heat pump should be determined based on the experimental data obtained by the variation of high and low stage refrigerant charge amount.

열교환기 효율이 초저온 냉동사이클 성능에 미치는 영향 (Effect on Heat Exchangers Efficiency on Performance of Cryogenic Refrigeration Cycles)

  • 윤정인
    • 동력기계공학회지
    • /
    • 제17권4호
    • /
    • pp.58-63
    • /
    • 2013
  • This paper presents the new cascade liquefaction cycles using $CO_2-C_2H_6-N_2$ and $CO_2-N_2O-N_2$. The performance of the cascade liquefaction cycles with respect to temperature differences in the LNG heat exchangers is analyzed using HYSYS software and then compared the performance of these cycles with phillips optimized cascade liquefaction cycle. The coefficient of performance of the new liquefaction cycles considered in this study decreases with the temperature differences in the LNG heat exchangers, but the compressor work, expander work and heat capacity in the LNG heat exchanger increases, respectively. From the comparison of performance of three cycles, the cascade liquefaction cycles using $CO_2-C_2H_6-N_2$ showed the highest COP. And the cycles using $CO_2-C_2H_6-N_2$ and $CO_2-N_2O-N_2$ presented the second and third highest COP, respectively. In the view of performance, the optimized cascade liquefaction cycle using $C_3H_8-C_2H_4-C_1H_4$ yields much better COP. But, in the environment view, it is found that the cascade liquefaction cycle using $CO_2-C_2H_6-N_2$ shows favorable characteristics.

대체냉매를 사용한 이원냉동 시스템의 성능에 관한 연구 (Study on the Performance of the Cascade System Using Alternative Refrigerants)

  • 박종훈;조금남
    • 설비공학논문집
    • /
    • 제13권7호
    • /
    • pp.564-571
    • /
    • 2001
  • The present study investigated the effect of key parameters on the performance of a cascade system using R-22 and R-23 refrigerants. Experimental data for the cascade system have been compared with simulation results using thermodynamic analysis. The cascade system tested at the evaporating temperature of $-80^{\circ}C $ and the condensing temperature of$40^{\circ}C $. The key experimental parameters were the evaporating temperature of the HTC(-35, -30, -25, -20, $-15^{\circ}C $) and mass flux of the HTC(200, 250, 300kg/$m^2$s). As the evaporating temperature and the mass flux of the HTC were increased respectively, the COP and the refrigerating efficiency were increased and then decreased while the volume flow rate per unit refrigeration capacity showed the opposite trend. The maximum COP and refrigerating efficiency were obtained at the evaporating temperature of the HTC of $-25^{\circ}C $ and the mass flux of 250 kg/$m^2$s.

  • PDF

대체 프레온 및 자연 냉매를 이용하는 이원 냉동시스템의 성능 예측 (Prediction on Performance of Cascade Refrigeration System using Alternative Freon and Natural Refrigerants)

  • 김종열;노건상
    • 한국산학기술학회논문지
    • /
    • 제13권4호
    • /
    • pp.1427-1433
    • /
    • 2012
  • 본 연구에서는 이원냉동시스템에서 사용되던 저온용 규제프레온냉매 R13 및 고온용 규제프레온냉매 R503의 대체냉매로서 프레온혼합냉매 및 친환경적 자연냉매를 사용하는 이원냉동시스템의 성능특성을 규명하고자 하였다. 이를 위해 일반적인 이원냉동시스템의 운전범위에서 과냉각도, 과열도, 응축온도, 증발온도, 캐스케이드 열교환기에서의 온도변화를 고려하였다. 고온시스템 및 저온시스템의 작동유체의 종류에 상관없이 이원냉동시스템의 COP는 캐스케이드의 온도영향을 받고 있으며, 또한 과냉각도가 증가할수록 COP는 높아지지만, 과열도의 영향은 크게 받지 않았다. 따라서 본 연구에서 고온용 시스템 및 저온용 시스템의 작동유체로 대체 프레온혼합냉매 및 자연냉매의 냉매조합 중에서 (R23/R290), (R23/R600), (R23/R600a), (R23/R717), (R744/R404A) 냉매를 사용하는 이원냉동시스템의 COP는 저온측에 R23, 고온측에 R22를 사용하는 시스템에 비해 20 ~ 36% 높게 나타났다.

고효율 HPGe 검출기의 동시합성효과 보정 연구 (Study on the cascade summing correction for high efficiency HPGe detector)

  • 이모성
    • Journal of Radiation Protection and Research
    • /
    • 제30권3호
    • /
    • pp.107-112
    • /
    • 2005
  • 단일 핵종의 붕괴시 방출된 두 감마선이 함께 검출기에 흡수될 때 cascade summing이 일어난다. 이 효과는 일부 핵종에서 10% 이상의 계통적 오차를 야기한다. 이들 동시합성 효과를 추산하기 위해 검출기 주위에서 측정한 피크-토탈 비를 사용하여 그 효과를 직접 계산하였다. 검출기 주번에서 주어진 에너지에 대한 피크-토탈 비는 일정하지 않을 수 있으며, 따라서 측정된 값의 평균을 사용하여야 한다 산란 물체에 의한 피크-토달 비의 영향에 대한 결과도 함께 포함되어 있다.

내부 열교환기 부착 $CO_2-C_3H_8$용 캐스케이드 냉동시스템의 성능 특성 (Performance Characteristics of a Cascade Refrigeration System with Internal Heat Exchanger using Carbon Dioxide (R744) and Propane (R290))

  • 손창효
    • 한국수소및신에너지학회논문집
    • /
    • 제20권6호
    • /
    • pp.526-533
    • /
    • 2009
  • In this paper, cycle performance analysis of $CO_2-C_3H_8$ (R744-R290) cascade refrigeration system with internal heat exchanger is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooling and superheating degree and gas cooling pressure and evaporating temperature in the propane (R290) low temperature cycle and the carbon dioxide (R744) high temperature cycle. The main results were summarized as follows : The COP of cascade refrigeration system of $CO_2-C_3H_8$ (R744-R290) increases with the increasing subcooling degree, but decreases with the increasing superheating degree. The COP of cascade refrigeration system increases with the increasing evaporating temperature, but decreases with the increasing gas cooling pressure. Therefore, superheating and subcooling degree, compressor efficiency, evaporating temperature and gas cooling pressure of $CO_2-C_3H_8$ (R744-R290) cascade refrigeration system have an effect on the COP of this system.