Study on the cascade summing correction for high efficiency HPGe detector

고효율 HPGe 검출기의 동시합성효과 보정 연구

  • Lee, M.S. (Dept. of Physics, Chongju University)
  • Published : 2005.09.30

Abstract

Cascade summing occurs when two gamma-rays emitted in the decay of a single nucleus both deposit energy in a detector. The effect may cause systematic errors that can reach levels of more than ten percent for some radionuclides. A method for estimation of the effect of these coincidences was developed. It is based on direct computation of the effect by means of peak to total ratio measured for the place around the detector. It has been shown that the P/T ratio for the given energy in the working space around the detector may not be a constant value and must use its mean value. Some results from a peak to total calibration study in the presence of scattering materials are also given.

단일 핵종의 붕괴시 방출된 두 감마선이 함께 검출기에 흡수될 때 cascade summing이 일어난다. 이 효과는 일부 핵종에서 10% 이상의 계통적 오차를 야기한다. 이들 동시합성 효과를 추산하기 위해 검출기 주위에서 측정한 피크-토탈 비를 사용하여 그 효과를 직접 계산하였다. 검출기 주번에서 주어진 에너지에 대한 피크-토탈 비는 일정하지 않을 수 있으며, 따라서 측정된 값의 평균을 사용하여야 한다 산란 물체에 의한 피크-토달 비의 영향에 대한 결과도 함께 포함되어 있다.

Keywords

References

  1. G.F.Knoll, Radiation Detection and Measurement, 3rd ed., pp. 449-450, John Wiley & Sons, New York(2000)
  2. IAEA, Measurement of Radionuclides in Food and the Environment, pp54, Technical Reports Series No.295, IAEA, Vienna(1989)
  3. 水本良彦, 日下部俊男, 岩田志朗, 'ゲルマニウム檢出器のビ一ク對ト一タル效率比' Radioisotopes, 36, 20(1987)
  4. Canberra, Genie2000 Customization Tools Manual, pp320-329, Canberra Industries, (2002)
  5. V.P. Koloyov, 'Estimation of True coincidence corrections for voluminous sources', J. Radioanal. Nucl. Chem., 210, 183-196(1996) https://doi.org/10.1007/BF02055417
  6. KDebertin, U.SchOtxing, 'Coincidence Summing Corrections in Ge(Li) Spectrometry at Low Source-to Detector Distance.', Nucl. Inst. Methods, 158, 471-477(1979) https://doi.org/10.1016/S0029-554X(79)94845-6
  7. D.Arnold and O.Shima, 'Coincidence-summing in gamma ray spectrometry by excitation of matrix X-rays', Applied Radiation and Isotopes, 52, 725-732(2000) https://doi.org/10.1016/S0969-8043(99)00236-5
  8. F.Piton et al, 'Efficiency transfer and coincidence summing corrections for gamma-ray spectrometry' Applied Radiation and Isotopes, 52, 791-795(2000) https://doi.org/10.1016/S0969-8043(99)00246-8
  9. H.L.Oczkowski, 'Calibration standard for use in gamma spectrometry and luminescence dating', Geochronometria, Vol. 20, pp 31-38 (2001)
  10. P.D.Felice P., P.Angelini, A.Fazio and R.Biagini, 'Fast procedure for coincidence-summing correction in gamma-ray spectrometry.' Applied Radiation and Isotopes 52: 745-752(2000) https://doi.org/10.1016/S0969-8043(99)00239-0
  11. 科學技術廳, 'ゲルマウム半導體檢出器を用いた機器分析法', 日本分析センタ一, p84(昭和61)
  12. M. Blaauw, SJ.Gelsema, 'The Influence of Peak Area Determination Bias in Gamma-ray Spectrometry in the Presence of True Coincidence Summing', Nuclear Instruments and Methods in Physics Research, A422, 417-422(1999)
  13. R.R.Kinsey, et al., 'The NUDAT/PCNUDAT Program for Nuclear Data,paper submitted to the 9th International Symposium of Capture Gamma_raySpectroscopy and Related Topics',(1996)