• Title/Summary/Keyword: carbon monoxide(CO) poisoning

Search Result 57, Processing Time 0.026 seconds

Recent Epidemiologic Features of Carbon Monoxide Poisoning in Korea: A Single Center Retrospective Cohort Study (최근 국내 일산화탄소 중독의 역학적 특징: 일개 응급의료센터의 후향적 코호트 연구)

  • Choi, Byung Ho;Jeon, Jin;Ryoo, Seung Mok;Seo, Dong Woo;Kim, Won Young;Oh, Bum Jin;Lim, Kyoung Soo;Sohn, Chang Hwa
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.10 no.2
    • /
    • pp.80-85
    • /
    • 2012
  • Purpose: The aim of this study was to describe the epidemiologic characteristics of adult patients with carbon monoxide poisoning who presented to the emergency department in recent years. Methods: This was a retrospective cohort study on adult consecutive patients with carbon monoxide (CO) poisoning who presented to the emergency department of a tertiary care university-affiliated hospital from January 1, 2008 to December 31, 2011. Results: A total of 91 patients were included in this study; there were 56(61.5%) unintentional and 35(38.5%) intentional poisonings. For the unintentional CO poisonings, the principal sources of exposure to CO were fire (39.3%), charcoal (17.9%), briquette charcoal (7.1%), wood burning boiler (7.1%), gas boiler (5.4%), automobile heater (3.6%), briquette boiler (3.6%), firewood (3.6%), and other items (12.5%). For the intentional CO poisonings, the sources were ignition charcoal (60.0%), briquette (31.4%), charcoal (5.7%) and butane gas (2.9%). For the unintentional CO poisonings, the places of poisoning were the home (58.9%), workplace (10.7%), public accommodation (8.9%), tent (8.9%), automobile (3.6%) and parking place (1.8%). For the intentional CO poisonings, the places of poisoning were the home (77.1%), public accommodation (11.4%) and automobile (11.4%). The proportion of intentional CO poisonings among total poisonings has increased significantly in recent years; 0.0% in 2008, 3.3% in 2009, 5.5% in 2010, and 29.7% in 2011. Conclusion: This study showed that in recent years in Korea, the source of CO has diversified broadly and intentional CO poisonings from burning ignition charcoal or briquettes has increased. Prevention efforts should consider these factors.

  • PDF

Effects of N-acetylcystein on changes in parvalbumin-positive interneurons in the hippocampus after carbon monoxide poisoning (급성 일산화탄소 중독 후 해마에서 Parvalbumin 양성 중간뉴론의 변화에 대한 N-acetylcystein의 효과)

  • Kim, Seon Tae;Yoo, Su Jin
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.19 no.2
    • /
    • pp.100-109
    • /
    • 2021
  • Purpose: The purpose of this study was to investigate effect of N-acetylcysteine (NAC) on the injury of putative parvalbumin positive interneurons defined by molecular marker and hippocampal long-term potentiation (LTP), a marker of neural plasticity following acute carbon monoxide (CO) poisoning. Methods: Adult Sprague-Dawley rats were exposed to 1100 ppm CO for 40 minutes followed by 3000 ppm CO for 20 minutes. Animals received daily intraperitoneal injection of NAC (150 mg/kg) for 5 days after CO exposure. Changes in learning and spatial memory were evaluated by Y-maze test 5 days after the poisoning. In vivo LTP in hippocampal CA1 area was evaluated by using extracellular electrophysiological technique. Immunohistochemical staining were adopted to observe expressional damages of parvalbumin (PV) immunoreactive interneurons in the hippocampus following the poisoning. Results: Acute CO intoxication resulted in no changes in memory performance at Y-maze test but a significant reduction of LTP in the in hippocampal CA1 area. There was also a significant reduction of PV (+) interneurons in the hippocampal CA1 area 5 days after CO poisoning. Daily treatment of NAC significantly improved hippocampal LTP impairment and reduced immunoreactivity for PV in the hippocampus following the acute CO poisoning. Conclusion: The results of this study suggest that reduction of hippocampal LTP and PV (+) interneurons in the hippocampus is sensitive indicator for brain injury and daily NAC injections can be the alternative therapeutics for the injury induced by acute CO poisoning.

A Carbon Monoxide Poisoning Case in Which Hyperbaric Oxygen Therapy Was Not Possible Due to Iatrogenic Pneumothorax after Unnecessary Central Catheterization

  • Kim, Hyung Il;Oh, Seong Beom
    • Journal of Trauma and Injury
    • /
    • v.32 no.4
    • /
    • pp.252-257
    • /
    • 2019
  • Hyperbaric oxygen therapy (HBOT) is used to treat carbon monoxide (CO) poisoning. However, untreated pneumothorax is an absolute contraindication for HBOT. More caution is needed with regard to monoplace hyperbaric chambers, as patient monitoring and life-saving procedures are impossible inside these chambers. Central catheterization is frequently used for various conditions, but unnecessary catheterization must be avoided because of the risk of infection and mechanical complications. Herein, we describe a case of CO poisoning in which iatrogenic pneumothorax developed after unnecessary subclavian central catheterization. The patient did not need to be catheterized, and HBOT could not be performed because of the pneumothorax. Hence, this case reminds us of basic-but nonetheless important-principles of catheterization.

The Risk Assessment of Carbon Monoxide Poisoning by Gas Boiler Exhaust System and Development of Fundamental Preventive Technology (가스보일러 CO중독 위험성 예측 및 근원적 예방기술 개발)

  • Park, Chan Il;Yoo, Kee-Youn
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.3
    • /
    • pp.27-38
    • /
    • 2021
  • We devised the system to automatically shutdown the boiler and to fundamentally block the harmful gases, including carbon monoxide, into the indoor when the exhaust system swerves: (1) The discharge pressure of the exhaust gas decreases when the exhaust pipe is disconnected. The monitoring system of the exhaust pipe is implemented by measuring the output voltage of APS(Air Pressure Sensor) installed to control the amount of combustion air. (2) The operating software was modified so that when the system recognizes the fault condition of a flue pipe, the boiler control unit displays the fault status on the indoor regulator while shutting down the boiler. In accordance with the ventilation facility standards in the "Rules for Building Equipment Standards" by the Ministry of Land, Infrastructure and Transport, experiments were conducted to ventilate indoor air. When carbon monoxide leaked in worst-case scenario, it was possible to prevent poisoning accidents. However, since 2013, the number of indoor air exchange times has been mitigated from 0.7 to 0.5 times per hour. We observed the concentration exceeding TWA 30 ppm occasionally and thus recommend to reinforce this criterion. In conclusion, if the flue pipe fault detection and the indoor air ventilation system are introduced, carbon monoxide poisoning accidents are expected to decrease significantly. Also when the manufacturing and inspection steps, the correct installation and repair are supplemented with the user's attention in missing flue, it will be served to prevent human casualties from carbon monoxide poisoning.

Comparison of hyperbaric oxygen therapy pressures for acute carbon monoxide poisoning (급성일산화탄소 중독환자에서 고압산소치료의 압력에 따른 예후 비교)

  • Jeong Yun Kim;Jihye Lim;Sung Hwa Kim;Sang Il Han;Yong Sung Cha
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.21 no.2
    • /
    • pp.117-127
    • /
    • 2023
  • Purpose: No consensus currently exists regarding the maximal pressure of hyperbaric oxygen (HBO2) therapy performed within 24 hours of acute carbon monoxide (CO) poisoning. This study aimed to evaluate the difference in therapeutic effects according to the first HBO2 pressure (3.0 atmospheres absolute [ATA] vs. 2.8 ATA). Methods: We used prospectively collected registry data on CO poisoning at a tertiary academic hospital in the Republic of Korea. Adult patients with acute CO poisoning treated with HBO2 within 24 hours after arrival at the emergency department and without the use of additional HBO2 after 24 hours between January 2007 and February 2022 were included. Data from 595 patients were analyzed using propensity score matching (PSM). Patients with mild (non-intubated) and severe (intubated) poisoning were also compared. Neurocognitive outcomes at 1 month after CO poisoning were evaluated using the Global Deterioration Scale combined with neurological impairment. Results: After PSM, the neurocognitive outcomes at 1-month post-CO exposure were not significantly different between the 2.8 ATA (110 patients) and 3.0 ATA (55 patients) groups (p=1.000). Similarly, there was also no significant difference in outcomes in a subgroup analysis according to poisoning severity in matched patients (165 patients) (mild [non-intubated]: p=0.053; severe [intubated]: p=1.000). Conclusion: Neurocognitive sequelae at 1 month were not significantly different between HBO2 therapy pressures of 2.8 ATA and 3.0 ATA in patients with acute CO poisoning. In addition, the 1-month neurocognitive sequelae did not differ significantly between intubated and non-intubated patients.

Long-term outcome of delayed neuropsychiatric sequelae after carbon monoxide poisoning (일산화탄소중독에서 지연신경정신장애의 장기적인 예후)

  • Yoo, Joo Young;Kim, Gap Teog;Koh, Chan Young
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.5
    • /
    • pp.519-528
    • /
    • 2018
  • Objective: Delayed neuropsychiatric sequelae (DNS) following carbon monoxide (CO) poisoning, which may result from a demyelinating leukoencephalopathy, is a disease with a poor prognosis. This study examined the factors affecting the long-term prognosis of DNS and the efficacy of hyperbaric oxygen therapy (HBOT) in patients with DNS. Methods: This retrospective study included 84 patients with DNS following CO poisoning from January 2013 to June 2016. HBOT was given to 24 patients. The patients were divided into an improvement group and non-improvement group based on their clinical condition on a telephone interview at intervals between 3 months and 3 years after the onset of DNS. The improvement group was defined as having Cerebral Performance Category (CPC) scores in their daily life that improve to 1 or 2 grade. Results: Of the 594 patients, DNS were found in 18.2%, and 70.2% (59 of 84) of the patients with DNS improved. The prognostic factors for the improvement of DNS were an age of 45 years or less (odds ratio [OR], 12.068; 95% confidence interval [CI], 2.393-60.858; P<0.005), CPC score of 1 or 2 group at the time of DNS onset (OR, 12.361; 95% CI, 3.161-48.330; P<0.005), and a lucid interval longer than 20 days (OR, 5.164; 95% CI, 1.393-19.141; P<0.01). HBOT was not associated with the improvement of DNS in CO poisoning (OR, 0.467; 95% CI, 0.172-1.269; P>0.1). Conclusion: Patients aged less than 45 years, low grade CPC score of 1 and 2, and lucid interval longer than 20 days are more likely to have a good prognosis. On the other hand, HBOT failed to produce a benefit for DNS patients.

The Risk Factors of Acute Cardiovascular and Neurological Toxicity in Acute CO Poisoning Patients and Epidemiologic Features of Exposure Routes (급성 일산화탄소 중독 환자에서 급성 심혈관계, 신경학적 독성의 위험요인과 노출 경로의 역학적 특성)

  • Park, Jinsoo;Shin, Seunglyul;Seo, Youngho;Jung, Hyunmin
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.18 no.1
    • /
    • pp.34-41
    • /
    • 2020
  • Purpose: This study evaluated aggressive hyperbaric oxygen therapy (HBOT) by understanding various exposure routes of acute carbon monoxide (CO) poisoning, the risk factors causing acute cardiovascular, and neurological toxicity caused by poisoning. Methods: A retrospective study was conducted based on the medical records of 417 acute CO poisoning patients who visited the emergency care unit from March 2017 to August 2019. The exposure routes, HBOT performance, age, sex, medical history (hypertension, diabetes mellitus, ischemic heart disease, heart failure), intentionality, loss of consciousness (LOC), intake with alcohol or sedatives, and initial test results (carboxyhemoglobin (COHb), troponin-I, electrocardiography, echocardiography, brain MRI) were examined. Comparative analysis of the clinical information was conducted between the groups that showed acute cardiovascular toxicity and neurological toxicity, and groups that did not. Results: Among 417 patients diagnosed with acute CO poisoning, 201 cases (48.2%) were intentional, and charcoal briquette was the most common route (169 patients (40.5%)). Two hundred sixteen cases (51.8%) were accidental, and fire was the most common route (135 patients (32.4%)). The exposure route was more diverse with accidental poisoning. Three hundred ninety-nine patients were studied for acute cardiovascular toxicity, and 62 patients (15.5%) were confirmed to be positive. The result was statistically significant in intentionality, LOC, combined sedatives, initial COHb, HTN, and IHD. One hundred two patients were studied for acute neurological toxicity, which was observed in 26 patients (25.5%). The result was statistically significant in age and LOC. Conclusion: Active HBOT should be performed to minimize damage to the major organs by identifying the various exposure routes of CO poisoning, risk factors for acute cardiovascular toxicity (intentionality, LOC, combined sedatives, initial COHb, HTN, IHD), and the risk factors for acute neurological toxicity (age, LOC).

A Preliminary Study for Effect of High Flow Oxygen through Nasal Cannula Therapy in Carbon Monoxide Poisoning (일산화탄소 중독 환자에서 고유속 비강 캐뉼라 산소치료 효과에 대한 예비 연구)

  • Kim, Young-Min;Kim, Sang-Chul;Park, Kwan-Jin;Lee, Seok-Woo;Lee, Ji-Han;Kim, Hoon
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.17 no.2
    • /
    • pp.102-107
    • /
    • 2019
  • Purpose: Acute carbon monoxide (CO) poisoning is one of the most common types of poisoning and a major health problem worldwide. Treatment options are limited to normobaric oxygen therapy, administered using a non-rebreather face mask or hyperbaric oxygen. Compared to conventional oxygen therapy, high-flow nasal cannula oxygen (HFNC) creates a positive pressure effect through high-flow rates. The purpose of this human pilot study is to determine the effects of HFNC on the rate of CO clearance from the blood, in patients with mild to moderate CO poisoning. Methods: CO-poisoned patients were administered 100% oxygen from HFNC (flow of 60 L/min). The fraction of COHb (fCOHb) was measured at 30-min intervals until it decreased to under 10%, and the half-life time of fCOHb (fCOHb t1/2) was subsequently determined. Results: At the time of ED arrival, a total of 10 patients had fCOHb levels ≥10%, with 4 patients ranging between 10% and 50%. The mean rate of fCOHb elimination patterns exhibits logarithmic growth curves that initially increase quickly with time (HFNC equation, Y=0.3388*X+11.67). The mean fCOHbt1/2 in the HFNC group was determined to be 48.5±12.4 minutes. Conclusion: In patients with mild to moderate CO poisoning, oxygen delivered via high flow nasal cannula is a safe and comfortable method to treat acute CO toxicity, and is effective in reducing the COHb half-life. Our results indicate HFNC to be a promising alternative method of delivering oxygen for CO toxicity. Validating the effectiveness of this method will require larger studies with clinical outcomes.

Clinical Evaluation of Patients Intoxicated by a Gas Leak at an Underground Shopping Center - Carbon Monoxide Poisoning - (지하상가 가스누출 사고 환자들에 대한 임상적 고찰 - 일산화탄소 중독 -)

  • Ahn, Ji-Young;Ko, Young-Gil
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.4 no.2
    • /
    • pp.122-127
    • /
    • 2006
  • Purpose: It is not easy to detect carbon monoxide (CO) leakage, and CO-intoxicated patients do not show a specific set of symptoms. The aims of this study are to clinically evaluate patients with CO gas intoxication from a CO leak at an underground shopping center, and to discuss the establishment of a disaster prevention plan. Methods: A total of 51 patients intoxicated by CO gas exposure in a gas disaster at a underground shopping center in Seoul on September 8, 2006 were enrolled in this study, and the patients' medical records were retrospectively reviewed. Results: The mean patient age was $29.4{\pm}6.3$. The initial mean COHb level was $14.98{\pm}6.97%$. The number of patients with COHb greater than 25% was three, and six patients experienced a syncopal attack. Only one patient-was treated with hyperbaric oxygen therapy. However, none of the patients complained of severe neurologic or cardiovascular symptoms. Conclusion: The symptoms of CO intoxication are non-specific and difficult to define, and the detection of CO leak-age is difficult. Thus, workplaces should be equipped with leakage sensors and automatic alarm systems and should have develop disaster prevention plans.

  • PDF

A Study on Indoor and Personal Exposures Concentrations to Carbon Monoxide in the Asan Area

  • Son, Bu-Soon
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.4
    • /
    • pp.1-3
    • /
    • 2000
  • Indoor carbon monoxide (CO) concentration and personal CO exposures were measured Asan where CO poisoning from twenty coal usage briquette as a domestic fuel to cook and space heating. Twenty-five were houses selected from the Asan area for the survey conducted in February 1997. Newly developed passive CO samplers were placed in the kitchen and living room for the indoor concentration measurement and were worn by homemakers for personal exposure monitoring. The daily average of indoor CO concentration was 16ppm in the kitchen and 10ppm in the living room. The indoor concentration and personal exposures to CO were different in types of the space heating system. House ventilating methods and socioeconomic conditions were also important factors in determining the indoor and personal CO level in Asan.

  • PDF