• Title/Summary/Keyword: carbon dioxide$CO_2$ absorbent

Search Result 62, Processing Time 0.031 seconds

Thermal Degradation of Aqueous MEA Solution for CO2 Absorption by Nuclear Magnetics Resonance (핵자기공명분석법을 이용한 수용성 아민 CO2 흡수제인 MEA의 열적변성 분석)

  • CHOI, JEONGHO;YOON, YEOIL;PARK, SUNGYOUL;BAEK, ILHYUN;KIM, YOUNGEUN;NAM, SUNGCHAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.5
    • /
    • pp.562-570
    • /
    • 2016
  • At the carbon dioxide capture process using the aqueous amine solution, degradation of absorbents is main factor to reducing the process performance. Also, degradation mechanism of absorbent is important for understanding the environmental risk, route of degradation products, health risk etc. In this study, the degradation products of MEA were studied to clarify mechanism in thermal degradation process. The degradation products were analyzed using a $^1H$ NMR (nuclear magnetic resonance) and $^{13}C$ NMR. The analysis methods used in this study provide guidelines that could be used to develop a degradation inhibitor of absorbent and a corrosion inhibitor.

Comparison of Phenyl Ethylamine and Hyamine Base as an Absorbent of $Carbon^{14}$ Dioxide ($C^{14}O_2$의 흡수제(吸收劑)로서 폐닐에칠아민과 하이아민베이스의 비교(比較))

  • Chiang, Yun-Hwan
    • Applied Biological Chemistry
    • /
    • v.14 no.1
    • /
    • pp.51-57
    • /
    • 1971
  • In order to compare their absorption abilities of carbon dioxide, Hyamine base and phenyl ethylamine were employed in wet combustion experiments. The known content of liver lipid and uniformly mixed palmitic $acid-C^{14}$ were oxidized with sulfuric acid and phosphoric acid. Carbon dioxide produced was trapped by the amines tested through thin tube. The amines absorbed carbon dioxide were mixed with diotal scintillator and counted by liquid scintillation counter. The counting efficiencies and radioactivity recoveries were 50 to 60 % and nearly 100 % for both amines. However, the absorption ability of carbon dioxide by phenyl ethylamine was about two times that of Hyamine base. This technique would not be necessary for the counting of liver lipid of swim, because the efficiencies were not increased and counting accuracies were similar to those of direct counting.

  • PDF

Membrane contactor and Carbon Dioxide Separation

  • 이규호
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.59-101
    • /
    • 2002
  • PVDF is good material for a hollow fiber membrane with high porosity and excellent hydrophobicity. Asymmetric PVDF hollow fiber membranes were prepared by the Loeb-Sourirajan phase inversion method. Asymmetric PVDF hollow fiber membranes could be controlled in pore size and porosity using various additives(LiCl, ZnCl$_2$) and internal coagulants (water, EtOH/water, and DMAc/water mixture). $CO_2$removal efficiency of asymmetric PVDF hollow fiber membranes was 1.2 times high than that of commercialized PP hollow fiber membranes at MEA 5wt% solution. $CO_2$flux of asymmetric PVDF hollow fiber membranes was 2.5 times higher than that of commercialized PP hollow fiber membranes. $CO_2$removal efficiency and absorption rate of asymmetric PVDF hollow fiber membranes were 30 times higher than those of packed column at absorbent $H_2O$. $CO_2$flux of asymmetric PVDF hollow fiber membranes at MEA 5wt% solution was 48 times higher than that of pure water. In the case of MEA 5wt% solution used as an absorbent, the $CO_2$absorption rate and removal efficiency of PVDF hollow fiber membrane were 2.3 times higher than that of a packed column.

  • PDF

Absorption Rate of Carbon Dioxide into Blended Ammonia Solution with Amine Additives in a Stirred Cell Reactor (교반셀에서 측정한 아민첨가 암모니아수 흡수제의 이산화탄소 흡수 반응 속도 측정)

  • Park, HoSeok;You, Jong Kyun;Hong, Won Hi;Kim, Jong Nam
    • Korean Chemical Engineering Research
    • /
    • v.47 no.2
    • /
    • pp.185-189
    • /
    • 2009
  • Absorption rate of carbon dioxide into aqueous ammonia absorbent(10 wt%) was measured in the temperature range from 293 K to 337 K using a stirred-cell reactor. The reaction rate constant was correlated with the Arrehnius equation and the activation energy was 50.42 kJ/mol. $CO_2$ absorption rate into modified ammonia absorbent was also investigated. For the modified ammonia absorbent, 1 wt% sterically hindered amines of 2-amino-2-methyl-1-propanol(AMP), 2-amino-2-methyl-1,3-propandiol(AMPD) and 2-amino-2-ethyl-1,3-propandiol(AEPD) were used as additives. The $CO_2$ absorption rate increased by adding 1 wt% of the amine additive, in the case of AMP additive, the absorption rate enhanced by about 53%.

Solubility Measurement of Carbon Dioxide in Alkylcarbonates and Triacetin at High Pressure (고압에서 알킬카보네이트와 트리아세틴의 이산화탄소 용해도 측정)

  • Kim, Ji Won;Hong, Won Hi;Hong, Yeon Ki
    • Clean Technology
    • /
    • v.21 no.2
    • /
    • pp.124-129
    • /
    • 2015
  • The constant-volume method was used to determine the solubility of CO2 in various physical absorbents such as DMPEG (dimethyl ether of polyethylene glycol), DEC (diethyl carbonate), DMC (dimethyl carbonate), and TAT (triacetin) in the total pressure range from 5 to 30 bar. The Peng-Robinson equation of state has been used to describe the equilibrium behavior of these mixtures. It was found that the solubility of absorbents was in the of DMPEG250 > TAT > DEC > DMC at the same temperature. Futhermore, the solubiity of blended absorbent of DMPEG250 and DEC is higher than that of DMPEG 250 alone. Therefore, blended absorbent of DMPEG250 and DEC is expected to be an effective and low cost absorbent for physical absorption in precombustion CO2 capture.

Degradation of Aqueous Monoethanolamine Absorbent (모노에탄올아민 흡수제의 열화특성 분석)

  • Cho, Youngmin;Nam, Sung-Chan;Yoon, Yeo-Il;Moon, Sungjun;Baek, Il Hyun
    • Applied Chemistry for Engineering
    • /
    • v.21 no.2
    • /
    • pp.195-199
    • /
    • 2010
  • The reversible chemical absorption using MEA (monoethanolamine), one of alkanolamine, is generally used as a conventionally method for $CO_{2}$ capture. Even MEA absorbent has excellent reactivity with $CO_{2}$, it has been known to have the decrease of absorption capacity caused by $CO_{2}$, $O_{2}$ or other acid gases in flue gas, corrosion and thermal degradation. In this study, MEA solutions degraded in the steam reforming process of refinery used and the absorption performance were compared for the used of conventional MEA solution. In case of 30 wt% MEA and mixture of 20 wt% thermal degraded absorbent (DP) and 10 wt% PZ, the absorption capacities were $0.5365mol-CO_{2}$/mol-absorbent and $0.5939mol-CO_{2}$/mol-absorbent respectively. PZ added thermally degraded absorbent showed the enhanced absorption capacity. On the contrary, the absorption rates were $1.1610kg_{f}/cm^2{\cdot}min$ for 30 wt% MEA, $0.5310kg_{f}/cm^2{\cdot}min$ for mixture of 20 wt% thermal degraded absorbent (DP) and 10 wt% PZ and $0.3525kg_{f}/cm^2{\cdot}min$ for 30 wt% thermally degraded absorbent only. The absorption rates of PZ added thermally degraded absorbent was higher than that of thermally degraded absorbent only. Therefore, it can be confirmed that thermally degraded absorbent can be reused as an absorbent for $CO_{2}$ by the addition of suitable additives.

Carbon Capture and CO2/CH4 Separation Technique Using Porous Carbon Materials (다공성 탄소재료를 이용한 CO2 포집 및 CO2/CH4 분리 기술)

  • Cho, Se Ho;Bai, Byong Chol;Yu, Hye-Ryeon;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.22 no.4
    • /
    • pp.343-347
    • /
    • 2011
  • Due to the strong dependence on fossil fuels within the history of human progress, it leads to disaster of the whole world like flood, shortage of water and extinction of the species. In order to curb carbon dioxide emissions, many technologies are being developed. Among them, porous carbon materials have important advantages over other absorbent, such as high surface area, thermal and chemical resistance, low cost, various pore distribution and low energy requirement for their regeneration. Carbon capture and storage (CCS) has attracted the significant research efforts for reducing green house gas emission using several absorbent and process. Moreover, the absorbent are used for the separation of bio mass gas that contains methane which is considered a promising fuel as new green energy resource. In this review, we summarized the recent studies and trend about the porous carbon materials for CCS as well as separation from the biogas.

A Study on Carbon Dioxide Capture Performance of KOH Aqueous Solution via Chemical Absorption (화학 흡수를 이용한 KOH 수용액의 이산화탄소 포집 성능에 관한 연구)

  • Yoo, Mi-Ran;Han, Sang-Jun;Shin, Ji-Yoon;Wee, Jung-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.1
    • /
    • pp.55-62
    • /
    • 2012
  • The present paper investigates the performance of the KOH aqueous solution as an absorbent to capture carbon dioxide ($CO_2$). The chemical absorption was carried out according to consecutive reactions that are generated in the order of $K_2CO_3$ and $KHCO_3$. The overall absorption was completed with following the physical absorption. When the absorption was conducted with the KOH as the limiting reactants in batch a reactor, $K_2CO_3$ production rate was the 1st order reaction for $OH^-$. However, $KHCO_3$ generation reaction was independent of the $CO_3^{2-}$ concentration and the rate was calculated to be $0.18gCO_2/min$ for all KOH absorbents, which is the same value of the reaction rate using $K_2CO_3$ aqueous solution as the absorbents. The overall $CO_2$ capture ratio of the 5% KOH absorbent was estimated to be 19% and the individual value in section 1 and 2 was 57 and 12%, respectively. The amount of $CO_2$ absorbed in the solution was very slightly less than the theoretical value, which was ascribed to the side reaction that produces $K_2CO_3{\cdot}KHCO_3{\cdot}1.5H_2O$ during the reaction and the consequent diminish in $CO_2$ absorption in the KOH solution.

Degradation Characteristics of Aqueous MEA Solution by Corrosion Products and Absorption Conditions (흡수 조건 및 부식 생성물에 의한 MEA 수용액의 변성 특성)

  • NAM, SUNGCHAN;SONG, YOONAH;BAEK, ILHYUN;YOON, YEOIL;YOU, JEONGKYUN;LEE, CHANGHA
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.3
    • /
    • pp.290-297
    • /
    • 2016
  • The absorbent loss due to degradation in $CO_2$ capture process using aqueous alkanol amine solution has adverse effect on the economics of overall process. The degradation causes absorbent loss, equipment corrosion, foaming, adhesive material producing and viscosity increase in operation. In this study, the degradation characteristics of $CO_2$ capture process using MEA (monoehtanolamine) under various conditions such as $O_2$ partial pressure, $CO_2$ loading and absorbent temperature. The effects of iron, which generated from the equipment corrosion, on absorbent degradation were studied using $Fe_2SO_4$ containing MEA solution. The produced gases were analyzed by FT-IR(Fourier Transform Infrared Spectrophotometer) and the specifically measured $NH_3$ concentration was used as a degradation degree of aqueous MEA solution. The experiments showed that the higher $CO_2$ loadings (${\alpha}$), $O_2$ fraction ($y_{O2}$) and reaction temperature enhanced the more degradation of aqueous MEA solution. Comparing other operation parameters, the reaction temperature most affected on the degradation. Therefore, it could be concluded that the above parameters affects on degradation should be considered for the selections of $CO_2$ absorbent and operating conditions.

Methane Recovery and Carbon Dioxide Stripping by MEA Solution the Autocirculation Bubble Lift Column Reactor (내부순환식 기포탑 반응기 상에서 MEA (monoethanolamine) 용액에 의한 이산화탄소 분리 및 메탄회수)

  • Lee, In-Hwa;Kim, Sun-Yil;Park, Ju-Young
    • Applied Chemistry for Engineering
    • /
    • v.18 no.3
    • /
    • pp.239-244
    • /
    • 2007
  • For the simultaneous methane recovery and $CO_2$-stripping, we have been developed dual vent auto circulation bubble lift column reactor, and evaluate optimum conditions for monoethanolamine (MEA) solutions as a $CO_2$ absorbent. At the 5 wt% MEA solution, we investigated the pH change during $CO_2$-stripping and absorption reaction, $CO_2$-stripping rate with reaction time, methane recovery efficiency for various inflow rates of air, $CO_2$-stripping rate for flow liquid over flow height, and $CO_2$-stripping dependency on the temperature of absolvent solutions. The suggested optimum conditions for $CO_2$ recovery with MEA in the dual vent auto circulation bubble lift column reactor were 40 mm over flow liquid height, 1.5 L/min of air inflow rate, and $25^{\circ}C$ of absorbent solution temperature.