• 제목/요약/키워드: capillary pressure

검색결과 306건 처리시간 0.025초

Capillary electrophoresis를 이용한 한국산 및 중국산 고사리의 원산지 판별방법 개발 (Development of the Discrimination Methods for Geographical Origin of Bracken(Pteridium aquilinum) by Capillary Electrophoresis)

  • 김은영;김정현;정경숙;류미라
    • 분석과학
    • /
    • 제17권2호
    • /
    • pp.192-197
    • /
    • 2004
  • The discrimination of bracken (Korean vs. Chinese) has been attempted using capillary electrophoresis (CE). Bracken (Pteridium aquilinum) was extracted with 30% methanol and separated on a uncoated fused-silica ($50{\mu}m{\times}27cm$) capillary. Conditions for optimal analysis include: temperature, $40^{\circ}C$; voltage, 8 kV; and pressure injection time, 5 sec. The optimal separation buffer was 0.3 M borate buffer (pH 8.5) containing 40 mM CHAPS with 30% ethylene glycol. Under the optimal conditions established for CE, the ratio of specific peak area (peak PA-1) to other peak area (peak PA-2) was effective in discrimination of Korean and Chinese bracken. The mean accuracy for discrimination of Korean and Chinese brackens were 80% and 86%, respectively.

랩온어칩 내부 미세유동제어를 위한 새로운 유동제어기법 (A New Flow Control Technique for Handling Infinitesimal Flows Inside a Lab-On-a-Chip)

  • 한수동;김국배;이상준
    • 대한기계학회논문집B
    • /
    • 제30권2호
    • /
    • pp.110-116
    • /
    • 2006
  • A syringe pump or a device using high electric voltage has been used for controlling flows inside a LOC (lab-on-a-chip). Compared to LOC, however, these microfluidic devices are large and heavy that they are burdensome for a portable ${\mu}-TAS$ (micro total analysis system). In this study, a new flow control technique employing pressure regulators and pressure chambers was developed. This technique utilizes compressed air to control the micro-scale flow inside a LOC, instead of a mechanical actuator or an electric power supply. The pressure regulator controls the output air pressure by adjusting the variable resistor attached. We checked the feasibility of this system by measuring the flow rate inside a capillary tube of $100{\mu}m$ diameter in the Re numbers ranged from 0.5 to 50. In addition, the performance of this flow control system was compared with that of a conventional syringe pump. The developed flow control system was found to show superior performance, compared with the syringe pump. It maintains automatically the: air pressure inside a pressure chamber whether the flow inside the capillary tube is on or off. Since the flow rate is nearly proportional to the resistance, we can control flow in multiple microchannels precisely. However, the syringe pump shows large variation of flow rate when the fluid flow is blocked in the microchannel.

혼합 작동 유체를 이용한 진동 세관형 히트 파이프의 압력 진동과 열전달 특성에 관한 연구 (The Study on Pressure Oscillation and Heat Transfer Characteristics of Oscillating Capillary Tube Heat Pipe Using Mixed Working Fluid)

  • 정현석;김정훈;김주원;김종수
    • 대한기계학회논문집B
    • /
    • 제26권2호
    • /
    • pp.318-327
    • /
    • 2002
  • In this paper, heat transfer and pressure oscillation characteristics on oscillating capillary tube heat pipe(OCHP) according to input heat flux, mixture ratio of working fluid and inclination angle were investigated and were compared single working fluid(R-142b) with binary mixture working fluid(R-142b-Ethano1). OCHP was made to serpentine structure of loop type with 10 turns by drilling the channels of length 220mm, width 1.5mm, and depth 1.5mm on the surface of brass plate. In this study, R-l42b and R-l42b-Ethanol were used as working fluids, the charging ratio of working fluids was 40(vol.%), the input heat flux to evaporating section was changed from 0.3W/㎠ to 1.8W/㎠, and mixture ratio of working fluid was R(100%), R(95%)-E(5%), R(90%)-E(10%), and R(85%)-E(15%). From the experimental results, it was found that the effective thermal conductivity of single working fluid was better than that of binary mixture working fluid. But, in case of binary mixture working fluid, critical heat flux was higher than that of single working fluid. And, the higher the mixture ratios of working fluid, the lower heat transfer performance. In case of pressure oscillation, as the inclination angle was lower, pressure wave was more irregular. These phenomena were more serious when the working fluid was binary mixture. Besides, when mixture ratio was higher, saturated pressure was increased, more irregular wave was observed and the mean amplitude was increased. For the same input heat flux, inclination angle and charging ratio, when pressure oscillation has sinusoidal wave, mean amplitude was small, and saturated pressure was low value, the heat transfer was excellent.

Sintered Metal Wicks Development for the High Performance Loop Heat Pipe(LHP) Systems

  • 최지훈;성병호;유정현;서민환;김철주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2136-2141
    • /
    • 2007
  • The Loop Heat Pipe(LHP) system uses capillary forces so as to pump the working fluid from heat acquisition to heat rejecting systems. The performance of the LHP systems depends mainly upon the operating performance of the wick structure. The capillary pressure increases with decreasing the pore size of the wick structure. By the way, the wick structure's permeability decreases with decreasing the pore size and the porosity. To obtain an ideal wick, the wick structure should possess several characteristics such as the small pore size, high porosity and chemical compatibility with working fluid. Sintered metal wicks have been mainly used as the capillary wick structure mounted in LHP because of the fact that the sintered metal wick has some advantages like convenient selection of wick material, smaller pore size and so on as well as high reliability. In this study, sintered metal wicks were developed to meet required several parameters to design the high performance LHP systems for obtaining even more effective cooling technologies.

  • PDF

Pressure Bomb법을 이용한 섬유방향 액체투과성 측정 (Measurement of Longitudinal Liquid Permeability Using Pressure Bomb Method)

  • 허종윤;강호양
    • Journal of the Korean Wood Science and Technology
    • /
    • 제25권3호
    • /
    • pp.66-74
    • /
    • 1997
  • Liquid permeabilities of red oak and several softwoods were measured by the pressure bomb method and a modified liquid permeability method in order to investigate their efficacy. The effect of preboiling and prefreezing on wood permeability were also examined for both green and resaturated specimens. Regardless of some disadvantages these two methods were revealed as a handy tool for quick evaluation of the permeability of an unknown species. The permeabilities of the resaturated specimens increased when preboiled. but decreased when prefrozen. For green specimens, however, pre freezing increased permeability. The discrepancy of the pre freezing effect on two specimens partially attributes to their difference of initial permeabilities. For all species except radiata pine heartwood, the radii of the effective capillary pores, derived from the water potential equation, distribute from $0.42{\mu}m$ to $7.2{\mu}m$. Those of radiata pine heartwood are below $0.46{\mu}m$.

  • PDF

루프 히트파이프의 작동에 영향을 미치는 인자에 대한 이론적 분석 (A Theoretical Analysis on the Factors Affecting the Operation of Loop Heat Pipe)

  • 이기우;전원표;이욱현;박기호
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1107-1116
    • /
    • 2004
  • In this paper, the effects of diverse parameters on the operation of loop heat pipe (LHP), such as particle diameter of sintered porous wick, wick porosity, vapor line diameter, thickness of wick and heating capacity were investigated by a theoretical analysis. A LHP has a wick only in its evaporator for the circulation of working fluid, and utilizes a porous wick structure of which pore size is very small to obtain a large capillary force. The working fluid is water and the material of sintered porous wick is copper. For these different parameters, capillary pressure, pressure drop in wick, pressure drops and temperature distribution were analyzed by a theoretical design method of LHP.

Syringe Infusion-based Contactless Atmospheric Pressure Ionization Mass Spectrometry for Small and Large Biomolecules

  • Lo, Ta-Ju;Chang, Chia-Hsien;Chen, Yu-Chie
    • Mass Spectrometry Letters
    • /
    • 제3권4호
    • /
    • pp.87-92
    • /
    • 2012
  • In this study, we explored a new approach for generating ions of organics and biomolecules using contactless atmospheric pressure ionization (C-API). That is, a tapered capillary (~20 cm) was connected to a syringe, which was coupled to a syringe pump for providing a given flow rate to introduce sample solution to the proximity of a mass spectrometer. The gas phase ions derived from analytes were readily formed in the capillary outlet, which was very close to the mass spectrometer (~1 mm). No external electric connection was applied on the capillary emitter. This setup is very simple, but it can function as an ion source. This approach can be readily used for the analysis of small molecules such as amino acids and large molecules such as peptides and proteins. The limit of the detection of this approach was estimated to be ~10 pM when using bradykinin as the sample. Thus, we believe that this approach should be very useful for being used as an alternative ion source because of its low cost, high sensitivity, simplicity, and ease of operation.

Effect of 50 ㎛ class granules on the Injection Behavior of Brushite Bone Cement Prepared via Pre-dissolution Route

  • Mun, Da Hye;Lee, Sang Cheon;Oh, Kyung-Sik
    • 한국분말재료학회지
    • /
    • 제27권6호
    • /
    • pp.468-476
    • /
    • 2020
  • The bone cement used for vertebroplasty must be sufficiently injectable. The introduction of granules reduces the amount of liquid required for liquefaction, implying that higher fluidity is achieved with the same amount of liquid. By employing β-tricalcium phosphate granules with an average diameter of 50 ㎛, changes in injectability are observed based on the paste preparation route and granular fraction. To obtain acceptable injectability, phase separation must be suppressed during injection, and sufficient capillary pressure to combine powder and liquid must work evenly throughout the paste. To achieve this, the granules should be evenly distributed. Reduced injection rates are observed for dry mixing and excessive granular content, owing to phase separation. All these correspond to conditions under which the clustered granules weakened the capillary pressure. The injected ratio of the paste formed by wet mixing displayed an inverted U-type shift with the granular fraction. The mixture of granules and powder resulted in an increase in the solid volume fraction, and a decrease in the liquid limit. This resulted in the enhancement of the liquidity, owing to the added liquid. It is inferred that the addition of granules improves the injectability, provided that the capillary pressure in the paste is maintained.

앉은 자세에서 좌골결절의 접촉압력과 혈류량과의 관계에 대한 연구 (Study on the Relationship between Vascular Perfusion and Interface Pressure under the Ischial Tuberosity in the Sitting Posture)

  • 허현;배태수;이석민;김신기;김경훈;문무성
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.645-646
    • /
    • 2006
  • Pressure-induced decubitus is a serious disease among the elderly people. Interface pressure occluding vascular perfusion is known to be a cause of decubitus. Therefore, it is essential to quantify the relationship between vascular perfusion and interface pressure among the elderly people. Nine elderly normal people ($57.8{\pm}5.6\;years,\;63.3{\pm}7.0kg,\;1.68{\pm}0.05m$) were participated. Pressure was applied on the ischial tuberosity in the sitting posture from 0mmHg to 135mmHg as capillary vascular perfusion was recorded. The average interface pressure to occlude vascular perfusion under the ischial tuberosity is 120mmHg. Vascular perfusion values at the capillary occlusion is often lower than 60% of the vascular perfusion at 15mmHg. Higher sampling number is required to have more accurate results.

  • PDF

닫힌 모세관에서 유체 이송에 관한 연구 (Investigation for the Fluid Motion in Closed End Capillaries)

  • 임호섭;임성진;이진기
    • 한국가시화정보학회지
    • /
    • 제12권2호
    • /
    • pp.23-29
    • /
    • 2014
  • Although many studies have been done on an open-end capillary, the invasion into a closed end capillary is still novel in its investigation. In this research we have explored the fluid invasion in closed-end capillaries where the shape of the meniscus and the height of invasion were accompanied by gas compression inside the capillary. Theoretically, the one dimensional momentum balance equation shows the fluid oscillation. In the experiments, we have found the different phenomena, either the fluid oscillation with low frequency or no oscillation. This discrepancy is mostly caused by two factors. First, a continuous decrease of the advancing contact angle due to decreasing invasion velocity as increasing pressure inside the closed-end capillary reduces the invasion velocities. Second, the high shear stress within the entrance length region was generated by the plug like velocity profile.