• Title/Summary/Keyword: capillary GC

Search Result 142, Processing Time 0.022 seconds

Volatile Components of Oyster Mushrooms (Pleurotus sp.) Cultivated in Korea (한국산 느타리 버섯류 (Pleurotus sp.)의 휘발성 향기성분)

  • Jung, Soon-Taek;Hong, Jai-Sik
    • The Korean Journal of Mycology
    • /
    • v.19 no.4
    • /
    • pp.299-305
    • /
    • 1991
  • Volatile aroma concentrates of four oyster mushrooms cultivated in Korea were obtained by the simultaneous distillation-extraction method. The volatile components were identified by the combined capillary gas chromatography-mass spectrometry and compared with the of retention data on GC of those authentic compounds. About 54 volatile compounds were identified in each of the four edible oyster mushrooms. The main compounds in Pleurotus ostreatus ASI 201 were 1-octen-3-ol, 3-octanone, 3-octanol, in Pleurotus sajor-caju, 1-octen-3-ol, 3-octanone, 1,5-octadien-3-one, 3-octanol, in Pleurotus florida-ostreatus-ostreatus, 1-octen-3-ol, n-hexanol, 3-octanone, 3-octanol, phenol, and in Pleurotus ostreatus (Ae-Neutari), 1-octen-3-ol, n-pentanal, n-hexanol, n-pentanol, 3-octanone, 3-octanol, 1,5-octadien-3-one, respectively. The mushrooms worked were rich in an alcohols and carbonyl compounds containing $C_8$ compounds. The peak area ratio of $C_8$ compounds in aroma concentrates were 56.60% in Pleurotus ostreatus ASI 201, 72.46% in Pleurotus sajor-caju, 54.84% in Pleurotus florida-ostreatus-ostreatus and 35.85% in Pleurotus ostreatus (Ae-Neutari ), respectively.

  • PDF

Protein Hydrolysis with Formic Acid and Analysis of Amino Acid Using Butylthiocarbamyl - trimethylsilyl (BTC - TMS) Derivatives by Gas Chromatography

  • 우강융;이동선;김민철
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.32 no.3
    • /
    • pp.320-324
    • /
    • 2003
  • The protein hydrolysis with 6 M formic acid containing 0.3% tryptamine was a superior method for amino acid analysis of standard amino acid and protein than 6 M HCI containing 0.3% tryptamine. The recoveries of standard amino acid after acid hydrolysis were more accurate in the 6 M formic acid hydrolysis than 6 M HCI hydrolysis, especially recovery of tryptophan showed higher values of 1.5 times than that of 6 M HCI hydrolysis. The results of analysis on the standard protein, bovine serum albumin, showed very similar values compared to the sequence analysis reported in the literature for the 6 M formic acid hydrolysis than 6 M HCI hydrolysis, especially in the tryptophan recovery as standard amino acid recovery. Butylthiocarbamyl - trimethylsilyl (BTC - TMS) derivatives of 22 standard amino acids were successfully resolved DB-17 capillary column. Excellent reproducibility of standard amino acid recovery and composition of bovine serum albumin were obtained with BTC-TMS derivatives.

Evaluation of vegetable oil rancidity by headspace gas chromatographic analysis (Headspace 가스크로마토그라피를 이용한 식용유의 산패도 측정)

  • Chun, Ho-Nam;Kim, Ze-Uook
    • Applied Biological Chemistry
    • /
    • v.35 no.1
    • /
    • pp.36-41
    • /
    • 1992
  • Several commercial cottonseed, corn and rapeseed oils were stored at $60^{\circ}C\;and\;70^{\circ}C$ with daily exposure of fluorescent light for 12 hours and evaluated their rancidity by headspace gas chromatographic analysis of pentanal and hexanal. The data of gas chromatographic analysis was compared with organoleptic flavor evaluation. For headspace gas chromatographic analysis, the volatile compounds were recovered by porous polymer trap and flushed into a fused silica capillary column at $250^{\circ}C$. Twenty-three GC peaks were identified on the basis of relative retention time of reference compounds and gas chromatography-mass spectrometry. The results showed that the contents of pentanal and hexanal were linearly increased during storage. A very simple linear relationship was found between organoleptic flavor scores and amounts of two volatile compounds with very high correlation coefficient. This results suggested the possible implication of pentanal and hexanal as an quality index for rancidity evaluation of cottonseed, corn and rapeseed oils.

  • PDF

Studies on the Simultaneous Determination of VNA and TSNA by GC - TEA (Gas chromatography-Thermal Energy Analyzer에 의한 휘발성 니트로소아민과 담배 특유의 니트로소아민들의 동시 분석연구)

  • Rhee, Mun-Su;Ji, Sang-Woon;Park, Yang-Su
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.15 no.2
    • /
    • pp.174-184
    • /
    • 1993
  • This is to investigate the methodology for the simultaneous determination of Wk, mk and TSNA using gas chromatography(GC) in combination with chemiluminescence detector, thermal energy analyzer(TEA) . The simultaneous analysis has been estimated by evaluating tobacco. The TEA was linked to GC equipped with non -polar SPB -5 fused silica capillary column which was introduced into the ceramic pyrolysis tube by the point of 16cm from the end of TEA. Quantification was carried out by internal standardization with WDPA after calibration of retention times and response factors with authentic nitrosoamines. It was demonstrated that WDPA was most preferable as internal standard for the simultaneous analysis. The recoveries of the internal standard were in the range of 83∼96% . Nitrosoamines in this method were detected with determination limit of 0.1ng and was made by a straight line in calibration curve by TEA response. The suitability of nitrosoamines extraction in tobacco leaf was investigated. It was most suitable to extract nitrosoamines from tobacco leaves with 0.01 M NaOH within a period of 8 hours. Thimerosal as an antibacterial agent was added to NaOH solution to prevent artifactual formation. The fractionation and the purification of nitrosoamines form alkaline extracts were conveniently performed using Extrelut multilayer column and dichloromethane. Reproducible and reliable results were obtained for the determination of nitrosamines in a relatively short time compared to previous known method. TSNA contents in burley were about 4 times higher as those in the fluecured tobacco.

  • PDF

Analysis of caffeine in aqueous sample by hollow fiber-liquid microextraction (HF-LPME) (HF-LPME를 이용한 수용액 시료중의 카페인 분석)

  • In, Chi-Yeon;Kim, Taek-Jae;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.84-92
    • /
    • 2008
  • A method for the determination of trace amount of caffeine in urine and various drink samples using hollow fiber-liquid phase microextraction (HF-LPME) and capillary gas chromatograph/nitrogen phosphorus detector (GC/NPD) has been established. HF-LPME method has been optimized with respect to several experimental parameters including the effects of the hollow fiber length, extraction solvent, stirring mode, pH and salt concentration for the determination of caffeine from aqueous samples. The correlation coefficient of calibration curve for caffeine was 0.9994. The average recovery was 102%(n=3). The established method is feasible for the determination of trace amounts of caffeine in several aqueous sample. The limit of detection (LOD) and the limit of quantitation (LOQ) have been found to be 2.5 and 10 ng/mL, respectively. The established HF-LPME method for the analysis of caffeine from aqueous sample can be used for the determination of biological, food and environmental samples.

An Improved Analytical Method for the Determination of Qualitative and Quantitative Characteristics of Di- and Trisaccharides in Honey using GC and GC/MS (GC 및 GC/MS에 의한 벌꿀 중의 이·삼당류 정성 및 정량 특성과 개선된 동시분석방법의 확립)

  • Kim, Jong-Bae;Jang, Eun-Suk;Kim, In-Suk;Lee, Hee-Jin;Lee, Hye-Jeong;Seo, Hyun-Sun;Park, Nam-Pyo
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.1
    • /
    • pp.27-36
    • /
    • 2015
  • The improved analytical method with gas chromatography (GC) and GC-mass spectrometry was established to identify and quantify disaccharides and trisacchrides in honey. In this method, the analysis of trimethylsilyl (TMS), TMS-oxime and TMS-methoxime sugars takes into account the determination of a single peak of complete separation on the chromatogram. The number of possible peaks for the qualitative and quantitative determination of TMS, TMS-oxime, and TMS-methoxime sugars was 17, 22, and 25, respectively. This new analytical method allowed for the determination of diand trisaccharides in honey by TMS-oxime and TMS-methoxime derivatives. This study suggested that the improved method is more suitable and precise than the other analytical methods for the simultaneous determination of sugars in honey.

Discrimination Analysis of the Geographical Origin of Foods (식품의 원산지 판별분석)

  • Choi, Jin-Young;Bang, Kyong-Hwan;Han, Kee-Young;Noh, Bong-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.5
    • /
    • pp.503-525
    • /
    • 2012
  • Consumers are increasingly concerned about the origin of foods, so the geographical origin of foods has been a major topic of debate and extensive research. Various instrumental methods (e.g. high performance liquid chromatography (HPLC), gas chromatography (GC), capillary electrophoresis (CE), electronic nose, near-infrared spectroscopy (NIRS), nuclear magnetic resonance spectroscopy (NMR), DNA analysis, multi-isotope analysis) in conjunction with statistical analysis, were developed and applied in attempt to provide reliable answers to their geographical origin. This study reviews current developments in the application of various methods for a clear geographical origin of foods. The limitation of discrimination analysis for geographical origin was also discussed.

The Analysis of Volatile Organic Compounds in Water by Using the Purge-and-Trap and the Gas Chromatography/Mass Selective Detector with Modified Indirect Coupling (퍼지-트랩장치와 변형된 간접 결합기를 부착한 기체크로마토그래피/질량 선택성 검출기를 이용한 물중의 휘발성 유기화합물의 분석)

  • 정영자
    • The Korean Journal of Food And Nutrition
    • /
    • v.12 no.2
    • /
    • pp.191-191
    • /
    • 1999
  • A Purge & Trap Concentrator was used to analyze various volatile organic compounds(VOCs) in wat-er. The object of this study was to observe the purge efficiency of 40 VOCs in water according to the change of parameters (purge time drypurge time sample temperature) and to determine the optimum condition for VOCs using the purge & Trap concentrator interfaced with a narrow capillary connected to a gas chromatography/mass spectrometry. The optimum condition of purge and trap is as follows: purge time at 11min drypurge time at 5min sample temperature at 6$0^{\circ}C$ at constant purge flow (40mol/min) constant desorption flow(20ml/min) desorption temperature(2$25^{\circ}C$) and desorption time (1min) At this analytical condition the detection limits of VOCs was in the range of 0.1~0.5$\mu$g/ml and the purge efficiency of each compound was over 70%.

Diterpene Resin Acids of Pinus Koraiensis Needles, Cortex and Xylem (잣나무 Diterpene Resin Acid 의 분석)

  • Han, James S.;Hwang, Byung-Ho
    • Journal of the Korean Wood Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.62-68
    • /
    • 1988
  • 잣나무의 Diterpene resin acids의 함량을 조사하기 위하여 침엽(needle), 일차조직(cortex), 목질부(sylem)별로 수지를 채취하여 최근 유행하고 있는 capillary column을 사용하는 GC를 이용하여 정량분석을 하였다. 분석결과 7종의 resin acid가 밝혀졌으며, 그 중 lambertianic acid는 neelde에서 74~87%, cortex에서 42-57%, xylem에서 18-28%로 분석되었는데, 다른 Pinus류에서 보다 훨씬 많은 양이 함유되어 병리곤충 분야나 농약 분야에서 고찰할 만한 가치가 있다고 생각하며, 그 외 l-obrnyltrans-p-coumarate, isocupressic acid pinusolide 등도 분석 되었다.

  • PDF

기체크로마토그래피-질량분석검출기와 고체상미량추출법을 이용한 물 중의 MTBE 미량분석

  • Jeon Chi-Wan;Lee Jeong-Hwa;Jeong Yeong-Uk
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.195-198
    • /
    • 2005
  • A solid-phase microextraction and gas chromatography-mass spectrometry for the extraction and analysis of methyl-tert-butyl ether has been described. methyl-tert-butyl ether was extracted from aqueous solution using SPME fiber coated polydimethylsiloxane and analysed by GC-MS with capillary column. Extraction parameters and chromatographic separation conditions were optimized. The applied method represented good analytical performance in terms of precision (3-8%, RSD) and accuracy(93-102%, mean recovery) with a method detection limit of 0.03 ppb.

  • PDF