• Title/Summary/Keyword: capacitance measurement

Search Result 397, Processing Time 0.024 seconds

A Study on the Development of Capacitive Transducer for Measurement of Small Displacement (미소변위 측정용 전기용량변환기 개발에 관한 연구)

  • 박영태;이래덕
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.5
    • /
    • pp.762-768
    • /
    • 1987
  • The capacitive transducers, which are used of the principle of capacitance changes by means of the variation of distance between electrodes, are usually utilized for measurement of small displacements. But the measurement ranges of this method are limited. In this study, the measurement ranges are extended by using the variation method of the surface area of electrodes. Thus the capacitive transducer and signal conditioner, which are having the capability of measurement range of 25mm and resolution of 0.1\ulcorner, have developed, and its environmental characteristics are also tested.

  • PDF

Application of Dielectric Sensor for Soil Moisture Measurement (토양 수분 측정을 위한 유전율식 쎈서 연구)

  • Oh, Yong-Taeg;Oh, Dong-Shig;Song, Kwan-Cheol;Shin, Jae-Sung;Im, Jung-Nam
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.31 no.2
    • /
    • pp.85-94
    • /
    • 1998
  • Due to relatively high permittivity of water in soils, we placed the soil condenser into soils to measure the soil moisture content. The soil condenser was made with two insulated iron sticks. The capacitance of the soil condenser was determined by the pulse period from RC type oscillation circuit and the highest voltage output accepting 10MHz pulse. After zero point adjustment, the measured relative capacitance percentage (RCS) to the standard condenser obtained by the oscillation circuit almost linearly correlated with the end depth of the sensor submerged in water. The RC type oscillation was disturbed by many sensor installed in a close distance in one place, presumably resulting in that the sensor sticks played as a interfering antennas generating or accepting electron waves from them. The temperature dependance of the output from the sensors could be corrected through experimentally determined revision function. Although lineal correlation was found between soil moisture and RCS, users should derive their own correlation function for every sensor to measure soil moisture, because the outputs were influenced by the installation depth and layout in the soil. The voltage type sensor responded inversely with soil moisture content and so was not suitable to the accurate measurement of soil moisture, but allows high economic benefit in various application such as simplified measurement of soil moisture and irrigation line control because of its low component count. The voltage type moisture sensor could be reinforced by relay controlling circuit to open and to close the solenoid valves respectively at optimal limits of the least and the most soil moisture according to user's adjustment.

  • PDF

Implementation of apparatus for detecting Ringer's solution exhaustion using electrostatic capacitance variation (정전용량변화를 이용한 링거액소진감지장치의 구현)

  • Kim, Cheong-Worl
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Electrostatic capacitance measurement method in a fine hose was proposed, in which two ring-type electrodes were disposed on the hose in the direction of fluid flow instead of the conventional face-to-face electrodes. With the proposed electrode structure, we realized a Ringer's solution exhaustion detector for an IV(invasive vein) injection set. On a 4 mm-diameter hose of IV set, we disposed two ring-type electrodes of 10 mm width at a distance of 5 mm each other and obtained 0.72 pF and 2.51 pF for air and 10 % dextrose Ringer's solution in the hose, respectively. The capacitance between the two electrodes varied with the hose-wraparound coverage of electrode as well as the width of electrode and the distance between the electrodes. For hose-wraparound electrode coverage of 75 %, the capacitance varied from 0.62 pF to 1.98 pF with the Ringer's solution level between the two electrodes. A charge amplifier converted the capacitance. variation into electric signal and a comparator was used to detect whether Ringer's solution was exhausted or not. The result was delivered to a host using a RF transmitter with 320 MHz carrier frequency.

A New Small Signal Modeling of RE MOSFETs including Charge Conservation Capacitances

  • Ickjin Kwon;Minkyu Je;Lee, Kwyro;Hyungcheol Shin
    • Proceedings of the IEEK Conference
    • /
    • 2000.07b
    • /
    • pp.957-960
    • /
    • 2000
  • A novel extraction method of high frequency small-signal model parameters for MOSFETS is proposed. From S-parameter measurement, this technique accurately extracts the model parameters including the charge conservation capacitance parameters. To consider charge conservation, nonreciprocal capacitance is considered. The modeled parameters fit the measurements very well without any optimization.

  • PDF

Design of Capacitive Displacement Sensor and Gap Measurement with High Precision Using Surface Acoustic Wave Device (표면 탄성파 장치를 응용한 용량 성 변위센서의 설계 및 초정밀 간극 측정)

  • Kim, Jae-Geun;Lee, Taek-Joo;Lim, Soo-Cheol;Park, No-Cheol;Park, Young-Pil;Park, Kyoung-Su
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.5
    • /
    • pp.437-443
    • /
    • 2010
  • SAW device is widely used as band pass filters, chemical or physical sensors, and actuators. In this paper, we propose the capacitive gap measurement system with high precision using SAW device. The research process is mainly composed of theoretical and experimental part. In the theoretical part, equivalent circuit model was used to predict the SAW response by the change of load impedance. In the experimental part, commercialized capacitor was used to see the SAW response by the change of load capacitance to check the feasibility as a sensor unit. After that, experimental setup to measure and adjust the gap was made and the SAW response by the change of gap which caused the capacitance change was measured. Finally, resolution and stroke was decided compared with the signal change and basic measurement noise level.

A "Thru-Short-Open" De-embedding Method for Accurate On-Wafer RF Measurements of Nano-Scale MOSFETs

  • Kim, Ju-Young;Choi, Min-Kwon;Lee, Seong-Hearn
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.1
    • /
    • pp.53-58
    • /
    • 2012
  • A new on-wafer de-embedding method using thru, short and open patterns sequentially is proposed to eliminate the errors of conventional methods. This "thru-short-open" method is based on the removal of the coupling admittance between input and output interconnect dangling legs. The increase of the de-embedding effect of the lossy coupling capacitance on the cutoff frequency in MOSFETs is observed as the gate length is scaled down to 45 nm. This method will be very useful for accurate RF measurements of nano-scale MOSFETs.

Evaluation of Grain Boundary Property in Oxide Ceramics by Isothermal Capacitance Trasient Spectroscopy (ICTS법을 이용한 산화물 세라믹스에서의 입계물성평가)

  • 김명철;한응학;강영석;박순자
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.5
    • /
    • pp.529-537
    • /
    • 1994
  • The principle of the Isothermal Capacitance Transient Spectroscopy[ICTS] were explained to measure the electronic trap levels in oxide ceramics. The measurement apparatus and the theory of the ICTS were described in detail. The trap energy evaluation was performed for the ZnO varistor and BaTiO3 ceramics. The grain boundary interface trap levels were detected at -5$0^{\circ}C$~6$0^{\circ}C$ in the case of ZnO varistor and PTCR samples, and the bulk trap levels were detected at 2$0^{\circ}C$~60~ in BaTiO3. The trap energy levels of the above samples could be directly determined by ICTS measurement.

  • PDF

A Study on the Development of a Precision Capacitance Measurement Bridge (초정밀 전기용량 측정 브리지 개발에 관한 연구)

  • Kim, Han-Jun;Kang, Jeon-Hong;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1324-1326
    • /
    • 2005
  • A high precision transformer bridge system for comparison of primary capacitance standards at low frequencies was developed. Its main transformer was constructed by special winding techniques and has the inphase and quadrature error of $0.073{\times}10^{-6}$ and $0.14{\times}10^{-6}$ at 1592 Hz($\omega=10^4$) respectively. But the measurement uncertainty of this bridge system can be achieved $0.03{\times}10^{-6}$ by using some substitution method.