A 12-year-old male poodle weighing 2.0 kg presented for evaluation of right thoracic limb lameness. The owner reported that the dog showed recurrent bilateral shoulder joint luxation after a car accident for a year. Recently, the left shoulder joint appeared well maintained, but right shoulder joint luxation was exacerbated. On physical examination, the dog showed non-weight bearing lameness on the right thoracic limb. Craniocaudal radiographic views revealed medial displacement of the right humerus. Mediolateral radiographic views revealed overlap of the glenoid cavity and humeral head. Muscle atrophy of the right thoracic limb, reduced biceps brachii muscle tendon tone, a tear of the medial glenohumeral ligament, and a rupture of the subscapularis tendon were identified intraoperatively. Transposition of the biceps muscle tendon was performed. However, at 7 days, there was evidence of right shoulder reluxation on radiographs. The second surgery was performed with two $2mm{\times}6mm$ cortical bone anchors and a $4mm{\times}6mm$ cancellous bone anchor placed in the cortical bone of the distal scapula and the cancellous bone of the proximal humerus respectively. Two scapular bone anchors were then connected with a humeral bone anchor using heavy nylon suture to minimize shoulder abduction range of motion. On radiographs right after surgery and 6 weeks after surgery, the affected limb revealed no evidence of medial shoulder luxation. At 6 months, no evidence of lameness was noted on the right thoracic limb.
We tried to extract bone morphogenetic protein (BMP) from the freeze-dried bovine cortical bone (FBCB) for bone graft, which were defatted with chloroform-methanol for 20 days, freeze-dried at $-80^{\circ}C$ for 7 days and sterilized by ethylene oxide gas. Two kg of FBCB were pulverized in a wheel mill to $0.5-2.0mm^3$ cubic in size. The bone particles were demineralized in 0.6N HCI for 10 days at chloroform-methanol$4^{\circ}C$ and defatted with chloroform-methanol for 6 hours at room temperature, which was going to be defatting and demineralized cortical bone (DDM). For extracting BMP, DDM was agitated continuously through 72 hours with magnetic stirrer at $4^{\circ}C$ into 12 times of volume of 6 M guanidine hydrochloride (Gdn-HCl) solution containing proteinase inhibitors to protect BMP such as 2mM N-ethylaleimide, 1mM iodoacetic acid, 1mM phenylmethylsulfonyl fluoride and a sterilizer, 1mM sodium azide. The extraction procedure was repeated for three times. All extracted solution was centrifuged at 10,000 rpm for 30 min and then, the supernatant was dialyzed with 12 times of volume of deionized water at $4^{\circ}C$ for 24-72 hours, which cut off below 6,000-8,000 molecular weight. The dialyzed specimen contained crude-BMP was centrifuged, freeze-dried, and weighted. Through these processing, we could obtained $84.9\%$ as FBCB, $17.8\%$ as DDM and $0.71\%$ as crude-BMP from the wet cortical bone without cancellous bone, marrow and muscles. The crude-BMP were obtained $68.3\%$ from the first extraction, $29.6\%$ from secondary and $2.1\%$ from tertiary, respectively. It was suggested that high yield of crude-BMP migth be explained by three-time repetition of the extraction processing for crude-BMP with Gdn-Hcl sol.
Journal of Dental Rehabilitation and Applied Science
/
v.23
no.1
/
pp.31-42
/
2007
The purpose of this study was to compare the stress distribution according to the splinting condition and non-splinting conditions on the finite element models of the two units implant prostheses. The finite element model was designed with the parallel placement of two fixtures ($4.0mm{\times}11.5mm$) on the mandibular 1st and 2nd molars. A cemented abutment and gold screw were used for superstructures. A FEA models assumed a state of optimal osseointegration, as the bone quality, inner cancellous bone and outer 2 mm compact bone was designed. This concluded that the cortical and trabecular bone were assumed to be perfectly bonded to the implant. Splinting condition had 2 mm contact surface and non-splinting condition had $8{\mu}m$ gap between two implant prosthesis. Two group (Splinting and non-splinting) were loaded with 200 N magnitude in vertical axis direction and were divided with subdivision group. Subdivision group was composed of three loading point; Center of central fossa, the 2 mm and 4 mm buccal offset point from the central fossa. Von Mises stress value were recorded and compared in the fixture-bone interface and bucco-lingual sections. The results were as follows; 1. In the vertical loading condition of central fossa, splinting condition had shown a different von Mises stress pattern compared to the non-splinting condition, while the maximum von Mises stress was similar. 2. Stresses around abutment screw were more concentrated in the splinting condition than the non-splinting condition. As the distance from central fossa increased, the stress concentration increased around abutment screw. 3. The magnitude of the stress in the cortical bone, fixture, abutment and gold screw were greater with the 4 mm buccal offset loading of the vertical axis than with the central loading.
Journal of Dental Rehabilitation and Applied Science
/
v.18
no.4
/
pp.277-288
/
2002
Seven finite element models were constructed in mandible having single screw-type implant fixture connected to the premolar superstructure, in order to evaluate how the length, diameter and platform shape of a screw-type fixture influence the stress in the supporting tissue around fixtures. Each finite element model was varied in terms of length, diameter, and platform shape of the fixture. In each model, 250N of vertical load was placed on the central pit of an occlusal plane and 250N of oblique load placed on the buccal cusp. The stress distribution in the supporting tissue and the other components was analysed using 2-dimensional finite element analysis and the maximum von Mises stress in each reference area was compared. Under lateral loading, the stress was larger at the abutment/fixture interface, and in the crestal bone, compared to the stress pattern under vertical loading. The amount of stress at the superstructure was similar regardless of the length, diameter and platform shape of a fixture. Around the longer fixture, the stress was decreased at the bone crest and subjacent cancellous bone and increased in the cancellous bone area apical to the fixture. Around the wider fixture, the stress was decreased at the abutment/fixture interface, and the bone crest and increased in the cancellous bone area apical to the fixture. Around the fixture having wider platform, less stress was produced at the abutment/fixture interface and the upper part of the cortical bone, compared to the fixture having standard platform. In conclusion, the stress distribution of the supporting tissue was affected by length, diameter, and platform shape of a fixture, and the fixture which was larger in diameter and length could reduce the stress in the supporting tissues at the bone-fixture interface and bone crest area.
Statement of problem: Standard type of ITI solid implant model in the 6.2mm thick jaw bone was axisymmetrically modelled for finite element stress analyses. Purpose: Primary objective was to investigate the influences or the characteristic design configuration of the ITI solid implant model on the bone stress with the course of osseointegration process at the bone/implant interfaces. To simulate the characteristics of the osseointegration process, five different stages of the bone/implant interface model were implemented. As load conditions, vertical load of 50N was taken into consideration. Bone at the cervical region of implant was the areas of concern where the higher level of stress were likely to take place. Results: The results indicated that rather slightly different stress level could be obtained as a function of the osseointegration conditions. Conclusion: Under vertical load, the lower level of stress was observed at the cervical cortical bone in the initial and final stages of osseointegration. Relatively higher stress level, however, was observed during the transitional stages where the osseointegration at the cancellous bone interface were yet to fully develop.
Statement of problem: Current tendencies of the implant macrodesign are tapered shapes for improved primary stability, but there are lack of studies regarding the relationship between the implant macrodesign and primary stability. Purpose: The purpose is to investigate the effect of implant macrodesign on the implant primary stability by way of resonance frequency analysis in the bovine rib bones with different kinds of quality. Material and method: Fifty implants of 6 different kinds from two Korean implant systems were used for the test. Bovine rib bones were cut into one hundred pieces with the length of 5 cm. Among them forty pieces of rib bones with similar qualities were again selected. For the experimental group 1, the thickness of cortical part was measured and 20 pieces of rib bones with the mean thickness of 1.0mm were selected for implant placement. For the experimental group 2, the cortical parts of the remaining 20 pieces of rib bones were totally removed and then implants were placed on the pure cancellous bone according to the surgical manual. After placement of all implants, the implant stability quotient(ISQ) was measured by three times, and its statistical analysis was done. Results: There are statistically significant differences in ISQ values among 4 different kinds of Avana system implants in the experimental group 2. For the experimental group 1, Avana system implants showed significantly different ISQ values, but when differences in the thickness of cortical parts were statistically considered, did not show any significant differences in ISQ values. Among Oneplant system implants, there are no significant differences in ISQ values for the experimental group 2 as well as for the experimental group 1. Conclusion: Within the limits of this study, bone quality and implant design have some influences on the primary stability of implants. Especially in the bone of poor quality, tapered shape of implants are more favorable for the primary stability of implants.
Journal of the Korean Society for Precision Engineering
/
v.23
no.11
s.188
/
pp.126-134
/
2006
In this study, the effect of stem-end design on contact pressure and stress distribution in revision TKR was investigated using finite element method. The finite element model of tibia, including the cortical bone, the cancellous bone and canal, was developed based on CT images. The implant models with various stem lengths, diameters, friction coefficients, and press-fit effects were considered. The results showed that the longer stem length, the stronger press-fit, the bigger stem diameter, and the higher friction coefficient increased both peak contact pressure and Von-Mises stress distributions. The results supported the clinical hypothesis that peak contact pressure and stress are related to the stem end pain. The results of this study will be useful to design the stem and reduce the end-of-stem pain in revision TKR.
Korean Journal of Computational Design and Engineering
/
v.11
no.5
/
pp.351-358
/
2006
Recently, the development of new structural model in fixed partial denture system is required to be started from the conceptual design with low cost, high performance and quality. In this point, a FEM based design of partial denture is used to investigate stress distribution on the durable shape. In this paper, the structural performances of partial dentures were analyzed under three biting forces. The periodontal embedding model is introduced on behalf of the detailed supporting tissue, which is composed of dentin, cortical bone, cancellous bone and periodontal ligament. Using topology optimization, the optimal reinforcement layout of connector was obtained and the detail shape in the fixed partial denture was designed.
A new method for analyzing the bone-remodeling process using quasi-molecular dynamics was proposed in this study. The effect of pressure due to bone marrow, which could not be considered in previous methods, was also considered in this method. Bone-remodeling response of the 2D vertebral body of lumbar spine to a uniaxial compressive displacement of 1.8564mm. corresponding to approximately 2kN of compressive load, was studied. Converged shape change of the cortical shell and rearrangement of cancellous bone structure matched well with a normal shape of the vertebral body. The calculated responses in the spinal elements also shows closed results compared with experimental results.
Craniofacial sutures absorb the stress transferred to skull. It was reported the cells of craniofacial sutures respond to exogenetic factors to be involved in growth control mechanism. In this study, we constructed a finite element model composed of cortical bone, cancellous bone, suture, PDL, and teeth by using CT images of a growing patient, simulating maxillary expansion to evaluate the effects of the thickness of sutures and type of maxillary expansion appliance on stress distribution in circummaxillary sutures.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.