• Title/Summary/Keyword: canal preparation

Search Result 181, Processing Time 0.029 seconds

A STUDY ON THE SHAPE OF A CANAL PREPARED WITH PROFILES IN A CURVED CANAL (PROFILE을 이용한 만곡 근관 형성시 근관의 형태에 관한 연구)

  • Park, Han-Soo;Lee, Min-Koo;Kim, Jong-Jin;Lee, Jong-Yeop
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.633-638
    • /
    • 1999
  • The purpose of our study is to evaluate the ability of nickel-titanium(NiTi) files in maintaining the original curvature of a curved root canal during canal preparation. Curved canals on translucent resin blocks were prepared with Profiles and stainless steel files and they were placed at the platform which can reproduce the same position. The unprepared and prepared canal forms were accurately compared by double exposure technique of photography. The results were as follows : 1 NiTi files made a canal comparatively taper, but stainless steel files didn't make a canal taper, wicest at midportion and comparatively wide at a apical portion. 2. Canals preparations with no. 25 Profile.06 up to the working length were most excellent in taperness and in maintaining the original curvature. Canals prepared with no 30 Profile.06 up to the working length made a little outer transportation at a apical portion, but not severe. 3. Canal preparations with Profile GT were excellent in taperness and in maintaining the original curvature, but made more enlargement toward the inner side at the starting portion of the curvature. 4. Canal preparations with stainless steel files were not tapered and provided the largest transportation.

  • PDF

Nanoleakage of apical sealing using a calcium silicate-based sealer according to canal drying methods

  • Yoon-Joo Lee;Kyung-Mo Cho;Se-Hee Park;Yoon Lee;Jin-Woo Kim
    • Restorative Dentistry and Endodontics
    • /
    • v.49 no.2
    • /
    • pp.20.1-20.13
    • /
    • 2024
  • Objectives: This study investigated the nanoleakage of root canal obturations using calcium silicate-based sealer according to different drying methods. Materials and Methods: Fifty-two extracted mandibular premolars with a single root canal and straight root were selected for this study. After canal preparation with a nickel-titanium rotary file system, the specimens were randomly divided into 4 groups according to canal drying methods (1: complete drying, 2: blot drying/distilled water, 3: blot drying/NaOCl, 4: aspiration only). The root canals were obturated using a single-cone filling technique with a calcium silicate-based sealer. Nanoleakage was evaluated using a nanoflow device after 24 hours, 1 week, and 1 month. Data were collected twice per second at the nanoscale and measured in nanoliters per second. Data were statistically analyzed using the Kruskal-Wallis and Mann-Whitney U-tests (p < 0.05). Results: The mean flow rate measured after 24 hours showed the highest value among the time periods in all groups. However, the difference in the flow rate between 1 week and 1 month was not significant. The mean flow rate of the complete drying group was the highest at all time points. After 1 month, the mean flow rate in the blot drying group and the aspiration group was not significantly different. Conclusions: Within the limitations of this study, the canal drying method had a significant effect on leakage and sealing ability in root canal obturations using a calcium silicate-based sealer. Thus, a proper drying procedure is critical in endodontic treatment.

EFFECT OF ANTICURVATURE FILING METHOD ON PREPARATION OF THE CURVED ROOT CANAL USING PROFILE (PROFILE을 이용한 근관형성 시 ANTICURVATURE FILING방법의 영향)

  • Song, Hyun-Ji;Chang, Ju-Hea;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.327-334
    • /
    • 2005
  • This study investigated the effect of anticurvature filing method on preparation of the curved root canal using ProFile. Thirty six resin blocks were divided equally into three groups by instrumentation motions: anticurvature filing motion. circumferential filing motion and straight up-and-down motion. Each resin block was sectioned at 8mm level from the apex and at the greatest curvature of the canal and reassembled in metal mold by a modified Bramante technique. All groups were instrumented with the ProFile system. At each levels. image of sectioned surface were taken using CCD camera under a stereomicroscope at $\times40$ magnification and stored. Distances of transportation at the inner and outer area of curvature and the centering ratio were determined and compared by statistical analysis. along with the assessment of the increase of root canal cross-sectional area. The results were as follows; 1. In all groups. there was no statistical difference in the mean increase of root canal cross-sectional area. the centering ratio. and the mean distances of transportation at the inner area of curvature at each level. 2. At 8mm level from the apex. the mean distances of transportation at the outer area of curvature decreases in following order anticurvature filing motion. circumferential filing motion. straight up-and­down motion but. no significant difference at the greatest curvature of the canal among three groups. Effect of anticurvature filing motion using ProFile does not seem to be different from other instrumentation motions at the inner area of curvature in curved root canal.

COMPARISON OF WARM GUTTA-PERCHA CONDENSATION TECHNIQUES IN RIBBON SHAPED CANAL : WEIGHT OF FILLED GUTTA-PERCHA (리본형태의 근관에서의 열연화 근관 충전법의 비교 : 근관 충전된 gutta-percha의 무게)

  • Kim, Hyun-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.3
    • /
    • pp.277-283
    • /
    • 2002
  • The purpose of this study is to evaluate the two warm gutta-percha filling techniques by measuring the weight changes of resin blocks before and after canal filling in ribbon shaped canal. Simulated ribbon shaped root canals in 30 transparent resin blocks were instrumented to #40 using .06 taper Profile. 15 resin blocks were obturated with gutta-percha using cold lateral condensation. Warm lateral condensation using the Endotec II was then accomplished on the same 15 blocks. Another 15 resin blocks were obturated using the System B. All canals were obturated without sealer. The resin blocks were weighed after canal preparation and after each subsequent obturation, and then weight changes of the resin blocks were calculated The results were as follows. 1. Warm lateral condensation using Endotec II and continuous wave of condensation using System B produced a denser obturation of gutta-percha compared with conventional cold lateral condensation (p<0.01). 2. There was no significant difference between warm lateral condensation and continuous wave condensation. In conclusion, the warm gutta-percha condensation techniques like warm lateral condensation and continuous wave condensation can be expected to bring favorable canal obturation results in ribbon shaped canals.

Effect of repetitive pecking at working length for glide path preparation using G-file

  • Ha, Jung-Hong;Jeon, Hyo-Jin;Abed, Rashid El;Chang, Seok-Woo;Kim, Sung-Kyo;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.2
    • /
    • pp.123-127
    • /
    • 2015
  • Objectives: Glide path preparation is recommended to reduce torsional failure of nickel-titanium (NiTi) rotary instruments and to prevent root canal transportation. This study evaluated whether the repetitive insertions of G-files to the working length maintain the apical size as well as provide sufficient lumen as a glide path for subsequent instrumentation. Materials and Methods: The G-file system (Micro-Mega) composed of G1 and G2 files for glide path preparation was used with the J-shaped, simulated resin canals. After inserting a G1 file twice, a G2 file was inserted to the working length 1, 4, 7, or 10 times for four each experimental group, respectively (n = 10). Then the canals were cleaned by copious irrigation, and lubricated with a separating gel medium. Canal replicas were made using silicone impression material, and the diameter of the replicas was measured at working length (D0) and 1 mm level (D1) under a scanning electron microscope. Data was analysed by one-way ANOVA and post-hoc tests (p = 0.05). Results: The diameter at D0 level did not show any significant difference between the 1, 2, 4, and 10 times of repetitive pecking insertions of G2 files at working length. However, 10 times of pecking motion with G2 file resulted in significantly larger canal diameter at D1 (p < 0.05). Conclusions: Under the limitations of this study, the repetitive insertion of a G2 file up to 10 times at working length created an adequate lumen for subsequent apical shaping with other rotary files bigger than International Organization for Standardization (ISO) size 20, without apical transportation at D0 level.

A Comparison of Stainless-Steel File and MFile-System® Ni-Ti Rotary Instrument in Canal Preparation using Dental Computed Tomography (치과용 단층촬영을 이용한 Stainless-Steel File과 MFile-System® 전동식 기구의 근관 성형 능력에 대한 비교 연구)

  • Seo, Dong-Jin;Yoon, Mi-Ran;Lee, Rin;Yu, Mi-Kyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.2
    • /
    • pp.173-180
    • /
    • 2006
  • Objectives The aim of this study is to compare the quality of root canal preparation completed using MFile-$System^{(R)}$ instrument ( Komet, Gebr.Brsaseler, Germany) and conventional stainless steel file in the canals of Maxillary molar teeth that had a canal curvature between $25^{\circ}$ or more Materials & Methods Buccal canals of 24 first and second maxillary molar teeth, extracted for periodontal and prosthetic reasons were used. Tissue fragments and calcified debris were removed from teeth by scaling and the teeth were stored in 10% formalin solution for 24 hour. Then, teeth were stored in saline until used. To be included the roots had to have completed formed apices and angle of curvature ranging between $25^{\circ}$ or more according to the criteria described by Schneider(1971). Palatal and Second mesiobuccal canals were not included. Teeth were embedded into transparent acrylic. The teeth were randomly divided into two experimental groups. All teeth were scanned by Dental CT (PSR9000N, Asahi, Japan) to determine the root canal shape before instrumentation. Image slices were prepared from the apical end point to the pulp chamber. The first two sections were 2 mm from the apical end of root and 2 mm below the orifice. Further section was recorded, dividing the distance between the sections of apical and coronal levels into two equal lengths. 12 teeth were instrumented using stainless steel fileand another 12 teeth were instrumented using MFile-$System^{(R)}$. Following the completion of the instrumentation, the teeth were again scanned and compared with the cross sectional images taken prior to canal preparation. Amount of transportation and centering ability was assessed. Student's t-test was used for statistical analysis. Result Less transportation occurred with MFile-$System^{(R)}$ rotary instrumentation than stainless steel instrument. MFile-$System^{(R)}$ had better centering ability than stainless steel instrument. Conclusion MFile-$System^{(R)}$ rotary instrumentation transported canals less and had good centering ability.

CBCT-based assessment of root canal treatment using micro-CT reference images

  • Lamira, Alessando;Mazzi-Chaves, Jardel Francisco;Nicolielo, Laura Ferreira Pinheiro;Leoni, Graziela Bianchi;Silva-Sousa, Alice Correa;Silva-Sousa, Yara Terezinha Correa;Pauwels, Ruben;Buls, Nico;Jacobs, Reinhilde;Sousa-Neto, Manoel Damiao
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.245-258
    • /
    • 2022
  • Purpose: This study compared the root canal anatomy between cone-beam computed tomography (CBCT) and micro-computed tomography (micro-CT) images before and after biomechanical preparation and root canal filling. Materials and Methods: Isthmus-containing mesial roots of mandibular molars(n=14) were scanned by micro-CT and 3 CBCT devices: 3D Accuitomo 170 (ACC), NewTom 5G (N5G) and NewTom VGi evo (NEVO). Two calibrated observers evaluated the images for 2-dimensional quantitative parameters, the presence of debris or root perforation, and filling quality in the root canal and isthmus. The kappa coefficient, analysis of variance, and the Tukey test were used for statistical analyses(α=5%). Results: Substantial intra-observer agreement (κ=0.63) was found between micro-CT and ACC, N5G, and NEVO. Debris detection was difficult using ACC (42.9%), N5G (40.0%), and NEVO (40%), with no agreement between micro-CT and ACC, N5G, and NEVO (0.05<κ<0.12). After biomechanical preparation, 2.4%-4.8% of CBCT images showed root perforation that was absent on micro-CT. The 2D parameters showed satisfactory reproducibility between micro-CT and ACC, N5G, and NEVO (intraclass correlation coefficient: 0.60-0.73). Partially filled isthmuses were observed in 2.9% of the ACC images, 8.8% of the N5G and NEVO images, and 26.5% of the micro-CT images, with no agreement between micro-CT and ACC, and poor agreement between micro-CT and N5G and NEVO. Excellent agreement was found for area, perimeter, and the major and minor diameters, while the roundness measures were satisfactory. Conclusion: CBCT images aided in isthmus detection and classification, but did not allow their classification after biomechanical preparation and root canal filling.