• Title/Summary/Keyword: camera image

Search Result 4,918, Processing Time 0.032 seconds

COMPARATIVE STUDY OF DIRECT DIGITAL RADIOGRAPHIC SYSTEM WITH FILM-BASED DIGITAL IMAGING SYSTEM USING EKTASPEED AND EKTASPEED PLUS FILM (직접 디지탈 방사선 촬영시스템과 Ektaspeed 및 Ektaspeed Plus 필름을 이용한 방사선 사진용 디지탈 영상시스템과의 비교 연구)

  • Do Jung-Joo;Kim Eun-Kyung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.1
    • /
    • pp.51-70
    • /
    • 1995
  • The purpose of this investigation was to compare the direct digital radiographic system with film-based digital imaging system using Ektaspeed and Ektaspeed Plus film with respect to image characteristics and detectability and evaluate the sensor noise with the use of subtraction method. Direct digital radiographic system which used was Sens-A-Ray system(Regam Medical Systems, Sundsvall, Sweden) and film-based digital imaging system was composed of Macintosh II ci computer, high resolution Sony XC-77 CCD camera and intraoral x-ray film(Kodak Ektaspeed film, Kodak Ektaspeed Plus film). Images were taken by using CCD sensor of Sens-A-Ray system, Ektaspeed film and Ektaspeed Plus film with variable exposure time(0.06s, 0.1s, 0.16s, 0.2s, 0.3s, 0.4s, 0.5s, 0.6s, O.8s, LOs), 5 times at each exposure time. And then ektaspeed films and ektaspeed plus films were digitized using CCD camera. Image groups were divided into 3 groups; Sens-A-Ray group(direct digital radiographic system), Ektaspeed group and Ektaspeed Plus group (film-based digital imaging system) They were assessed by the following three aspects; image density, image contrast and detectability and sensor noise of Sens-A-Ray system was also evaluated. The results were as follow : 1. S group showed higher density than E , EP group except at the low exposure time(p<0.01). 2. S group showed higher contrast than E,EP group except at the high exposure time(p<0.01). 3. All groups showed good detectability at the each proper exposure time. Lowest exposure time which shows maximum detectability in S,EP group(0.5s) was lower than that in E group(0.6s). 4. Sensor noise of Sens-A-Ray system generally increased according to exposure time. On the basis of the above results, it was considered that Sens-A-Ray system could show higher speed, higher contrast than Ektaspeed, Ektaspeed Plus film except at too high and low exposure time and the same detectability as the conventional intraoral film.

  • PDF

Chromosome Analysis in Clinical Samples by Chromosome Diagnostic System Using Fluorescence in Situ Hybridization (국산 Fluorescence in Situ Hybridization 시스템을 이용한 다양한 검체에서의 염색체 분석)

  • Moon, Shin-Yong;Pang, Myung-Geol;Oh, Sun-Kyung;Ryu, Buom-Yong;Hwang, Do-Yeong;Jung, Byeong-Jun;Choe, Jin;Sohn, Cherl;Chang, Jun-Keun;Kim, Jong-Won;Kim, Seok-Hyun;Choi, Young-Min
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.24 no.3
    • /
    • pp.335-340
    • /
    • 1997
  • Fluorescence in situ hybridization (FISH) techniques allow the enumeration of chromosome abnormalities and from a great potential for many clinical applications. In order to produce quantitative and reproducible results, expensive tools such as a cooled CCD camera and a computer software are required. We have developed a Chromosome Image Processing System (Chips) using FISH that allows the detection and mapping of the genetic aberrations. The aim of our study, therefore, is to evaluate the capabilities of our original system using a black-and-white video camera. As a model system, three repetitive DNA probes (D18Z1, DXZ1, and DYZ3) were hybridized to variety different clinical samples such as human metaphase spreads and interphase nuclei obtained from uncultured peripheral blood lymphocytes, uncultured amniocytes, and germ cells. The visualization of the FISH signals was performed using our system for image acquisition and pseudocoloring. FISH images were obtained by combining images from each of probes and DAPI counterstain captured separately. Using our original system, the aberrations of single or multiple chromosomes in a single hybridization experiment using chromosomes and interphase nuclei from a variety of cell types, including lymphocytes, amniocytes, sperm, and biopsied blastomeres, were enabled to evaluate. There were no differences in the image quality in accordance with FISH method, fluorochrome types, or different clinical samples. Always bright signals were detected using our system. Our system also yielded constant results. Our Chips would permit a level of performance of FISH analysis on metaphase chromosomes and interphase nuclei with unparalleled capabilities. Thus, it would be useful for clinical purposes.

  • PDF

Smart window coloring control automation system based on image analysis using a Raspberry Pi camera (라즈베리파이 카메라를 활용한 이미지 분석 기반 스마트 윈도우 착색 조절 자동화 시스템)

  • Min-Sang Kim;Hyeon-Sik Ahn;Seong-Min Lim;Eun-Jeong Jang;Na-Kyung Lee;Jun-Hyeok Heo;In-Gu Kang;Ji-Hyeon Kwon;Jun-Young Lee;Ha-Young Kim;Dong-Su Kim;Jong-Ho Yoon;Yoonseuk Choi
    • Journal of IKEEE
    • /
    • v.28 no.1
    • /
    • pp.90-96
    • /
    • 2024
  • In this paper, we propose an automated system. It utilizes a Raspberry Pi camera and a function generator to analyze luminance in an image. Then, it applies voltage based on this analysis to control light transmission through coloring smart windows. The existing luminance meters used to measure luminance are expensive and require unnecessary movement from the user, making them difficult to use in real life. However, after taking a photography, luminance analysis in the image using the Python Open Source Computer Vision Library (OpenCV) is inexpensive and portable, so it can be easily applied in real life. This system was used in an environment where smart windows were applied to detect the luminance of windows. Based on the brightness of the image, the coloring of the smart window is adjusted to reduce the brightness of the window, allowing occupants to create a comfortable viewing environment.

The Estimation of Physical/Biological Parameters of Greenhouse Soil by Image Processing (컬러 영상처리에 의한 시설재배지 토양의 생물 물리적 환경변수 추정)

  • Kim, H.T.;Kim, J.D.;Moon, J.H.;Lee, K.S.;Kang, K.H.;Kim, W.;Lee, D.W.
    • Journal of Biosystems Engineering
    • /
    • v.28 no.4
    • /
    • pp.343-350
    • /
    • 2003
  • This study was conducted to find out the coefficient relationships between intensity values of image processing and biological/physical parameters of soil in greenhouses. Soil images were obtained by an image processing system consisting of a personal computer and a CCD earners. A software written in Visual C$\^$++/ systematically integrated the functions of image capture, image processing, and image analysis. Image processing data of the soil samples were analyzed by the method of regression analysis. The results are as follows. For detecting soil density of unbroken soil samples, the highest correlation coefficients of 0.82 and 0.84, respectively were obtained fur R-value and S-value among image processing data while it was 0.97 for G-value. Considering the relationship between biological characteristics and image processing data of soil in greenhouse, the correlation was found generally low. For pH of unbroken soil sample, the correlation coefficients were found 0.87, 0.85, and 0.94, respectively with G, I, and H values of image processing data. In the case of bacteria, any correlation was not found with the image processing data For Actinomyctes, they were 0.86 and 0.85, respectively with G-value and B-value of image processing data showing high correlation coefficient compared to the other variables. The correlation coefficient between Fungi and H-value was shown 0.88, the highest among the variables higher than 0.8 while the other variables showed low correlation. For broken soil samples from greenhouse, the relation between biological parameter and image processing data were rarely shown in this study. The results of this study indicated that most of correlation coefficient between the variables were usually lower than 0.01. Accordingly, it was assumed that the soil should be used without broken to fairly estimate biological characteristics using CCD camera.

Evaluation of Contrast and Resolution on the SPECT of Pre and Post Scatter Correction (산란보정 전, 후의 SPECT 대조도 및 분해능 평가)

  • Seo, Myeong-Deok;Kim, Yeong-Seon;Jeong, Yo-Cheon;Lee, Wan-Kyu;Song, Jae-Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.127-132
    • /
    • 2010
  • Purpose: Because of limitation of image acquisition method and acquisition time, scatter correction cannot perform easily in SPECT study. But in our hospital, could provide to clinic doctor of scatter corrected images, through introduction of new generation gamma camera has function of simple scatter correction. Taking this opportunity, we will compare scatter corrected and non-scatter corrected image from image quality of point of view. Materials and Methods: We acquisite the 'Hoffman brain phantom' SPECT image and '1mm line phantom' SPECT image, each 18 times, with GE Infinia Hawkeye 4, SPECT-CT gamma camera. At first, we calculated each contrast from axial slice of scatter corrected and non-scatter corrected SPECT image of 'Hoffman brain phantom'. and next, calculated each FWHM of horizontal and vertical from axial slice of scatter corrected and non-scatter corrected SPECT image of '1mm line phantom'. After then, we attempted T test analysis with SAS program on data, contrast and resolution value of scatter corrected and non-scatter corrected image. Results: The contrast of scatter corrected image, elevated from 0.3979 to 0.3509. And the resolution of scatter corrected image, elevated from 3.4822 to 3.6375. p value were 0.0097 in contrast and <0.0001 in resolution. We knew the fact that do improve of contrast and resolution through scatter correction. Conclusion: We got the improved SPECT image through simple and easy way, scatter correct. We will expect to provide improved images, from contrast and resolution point of view. to our clinic doctor.

  • PDF

A Measurement Error Correction Algorithm of Road Structure for Traveling Vehicle's Fluctuation Using VF Modeling (VF 모델링을 이용한 주행차량의 진동에 대한 도로 계측오차 보정 알고리듬)

  • Jeong, Yong-Bae;Kim, Jung-Hyun;Seo, Kyung-Ho;Kim, Tae-Hyo
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2005.11a
    • /
    • pp.190-200
    • /
    • 2005
  • In this paper, the image modelling of road's lane markings is established using view frustum(VF) modeling. This algorithm also involve the real time processing of the 3D position coordinate and the distance data from the camera to the points on the 3D world coordinate by the camera calibration. In order to reduce their measurement error, an useful algorithm for which analyze the geometric variations clue to traveling vehicle's fluctuation using VF model is proposed. In experiments, without correction, for instance, the $0.4^{\circ}$ of pitching rotation gives the error of $0.4^{\sim}0.6m$ at the distance of 10m, but the more far distance cause exponentially the more error. We confirmed that this algorithm can be reduced less than 0.1m of error at the same condition.

  • PDF

MPEG Video Segmentation Using Frame Feature Comparison (프레임 특징 비교를 이용한 압축비디오 분할)

  • 김영호;강대성
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.4 no.2
    • /
    • pp.25-30
    • /
    • 2003
  • Recently, development of digital technology is occupying a large part of multimedia information like character, voice, image, video, etc. Research about video indexing and retrieval progresses especially in research relative to video. In this paper, we propose new algorithm(Frame Feature Comparison) for MPEG video segmentation. Shot, Scene Change detection is basic and important works that segment it in MPEG video sequence. Generally, the segmentation algorithm that uses much has defect that occurs an error detection according to a flash of camera, movement of camera and fast movement of an object, because of comparing former frames with present frames. Therefore, we distinguish a scene change one more time using a scene change point detected in the conventional algorithm through comparing its mean value with abutted frames. In the result, we could detect more corrective scene change than the conventional algorithm.

  • PDF

An alternative method for smartphone input using AR markers

  • Kang, Yuna;Han, Soonhung
    • Journal of Computational Design and Engineering
    • /
    • v.1 no.3
    • /
    • pp.153-160
    • /
    • 2014
  • As smartphones came into wide use recently, it has become increasingly popular not only among young people, but among middle-aged people as well. Most smartphones adopt capacitive full touch screen, so touch commands are made by fingers unlike the PDAs in the past that use touch pens. In this case, a significant portion of the smartphone's screen is blocked by the finger so it is impossible to see the screens around the finger touching the screen; this causes difficulties in making precise inputs. To solve this problem, this research proposes a method of using simple AR markers to improve the interface of smartphones. A marker is placed in front of the smartphone camera. Then, the camera image of the marker is analyzed to determine the position of the marker as the position of the mouse cursor. This method can enable click, double-click, drag-and-drop used in PCs as well as touch, slide, long-touch-input in smartphones. Through this research, smartphone inputs can be made more precise and simple, and show the possibility of the application of a new concept of smartphone interface.

Realtime Vehicle Tracking and Region Detection in Indoor Parking Lot for Intelligent Parking Control (지능형 주차 관제를 위한 실내주차장에서 실시간 차량 추적 및 영역 검출)

  • Yeon, Seungho;Kim, Jaemin
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.418-427
    • /
    • 2016
  • A smart parking management requires to track a vehicle in a indoor parking lot and to detect the place where the vehicle is parked. An advanced parking system watches all space of the parking lot with CCTV cameras. We can use these cameras for vehicles tracking and detection. In order to cover a wide area with a camera, a fisheye lens is used. In this case the shape and size of an moving vehicle vary much with distance and angle to the camera. This makes vehicle detection and tracking difficult. In addition to the fisheye lens, the vehicle headlights also makes vehicle detection and tracking difficult. This paper describes a method of realtime vehicle detection and tracking robust to the harsh situation described above. In each image frame, we update the region of a vehicle and estimate the vehicle movement. First we approximate the shape of a car with a quadrangle and estimate the four sides of the car using multiple histograms of oriented gradient. Second we create a template by applying a distance transform to the car region and estimate the motion of the car with a template matching method.

Discharge Characteristics and UV Images at Air on Bushing Model with Contaminations (기중 부싱모델의 오염물질에 따른 방전 특성과 자외선 이미지)

  • Pang, Man-Sik;Choi, Jae-Hyeong;Kim, Woo-Jin;Kim, Young-Seok;Kim, Sang-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.12
    • /
    • pp.996-1001
    • /
    • 2011
  • A bushing is very important because it must supply the high voltage to the power equipment. Generally, the surface of bushing is contaminated with rain, dust, salt and others. A bushing with contaminations at air are serious problem in insulation. Therefore, it is important to understand the inspection and diagnoses of the safety. The ultra-violet rays(UV) camera has attracted interest from the view point of easy judgement. In this paper, we will report on the corona discharge characteristics on bushing model with contaminations. Also, UV images of discharge in air are analyzed using prototype UV camera of Korea. These results are studied at both AC and DC voltage under a non-uniform field.