Seo Seungwon;Kim Sunghyun;Choi Junho;Park Hyuk;Lee Hojin;Kim Yonghoon;Kang Gumsil
Proceedings of the KSRS Conference
/
2004.10a
/
pp.577-580
/
2004
To overcome with large size noise source distribution network design difficulty in interferometric radiometer system, especially for sub-Y-type array, a new on-board calibration technique using noise re-radiation is proposed in this paper. The suggested calibration technique is using noise re-radiation effect of center antenna after noise source injection from matched load. This approach is especially proper to sub-Y-type array interferometric synthetic aperture radiometer in mm-wave frequency band. Compared with noise injection network of a conventional synthetic aperture radiometer, the system mass, volume, and hardware complexity is reduced and cost-effective. Only one internal noise source, matched load, is used for injection using noise re-radiation technique a small set of sub-Y receiver channels is calibrated. Detailed calibration scenario is discussed and simulation results about noise reradiation effect are presented.
Magazine of the Korean Society of Agricultural Engineers
/
v.45
no.5
/
pp.117-125
/
2003
Since the recorded information used for operation of a catchment modelling system contain errors that influence the calibration of catchment modelling system control parameter values, the accurate estimation of these parameters is difficult. Despite these influences, existing traditional calibration approaches focus only on achieving the best "curve fitting" between simulated and recorded data, and not on generic evaluation of control parameter values. This paper introduces an Early Stopping Technique which is aimed at avoiding the procedure of curve-fitting through monitoring improvements in the objective function used for assessing the optimal parameter set. Application of this approach to the calibration of SWMM (Storm Water Management Model) on the Centennial Park catchment in Sydney, Australia is outlined. outlined.
Journal of the Institute of Electronics Engineers of Korea TC
/
v.37
no.8
/
pp.11-23
/
2000
Head-eye calibration is a process for estimating the unknown orientation and position of a camera with respect to a mobile platform, such as a robot wrist. We present a new head-eye calibration technique which can be applied for platforms with rather limited motion capability In particular, the proposed calibration technique can be applied to find the relative orientation of a camera mounted on a linear translation platform which does not have rotation capability. The algorithm find the rotation using a calibration data obtained from pure Translation of a camera along two different axes We have derived a calibration algorithm exploiting the rectification technique in such a way that the rectified images should satisfy the epipolar constraint. We present the calibration procedure for both the rotation and the translation components of a camera relative to the platform coordinates. The efficacy of the algorithm is demonstrated through simulations and real experiments.
The structured-light 3D reconstruction technique uses a coded-pattern to find correspondences between the camera image and the projector image. To calculate the 3D coordinates of the correspondences, it is necessary to calibrate the camera and the projector. In addition, the calibration results affect the accuracy of the 3D reconstruction. Conventional camera-projector calibration techniques commonly require either expensive hardware rigs or complex algorithm. In this paper, we propose an easy camera-projector calibration technique. The proposed technique does not need any hardware rig or complex algorithm. Thus it will enhance the efficiency of structured-light 3D reconstruction. We present two camera-projector systems to show the calibration results. Error analysis on the two systems are done based on the projection error of the camera and the projector, and 3D reconstruction of world reference points.
The Journal of Korean Institute of Communications and Information Sciences
/
v.21
no.7
/
pp.1820-1832
/
1996
The performance of a carrier recovery is severely degraded because of amplitude fluctuations and random phases of the received signai caused by multipath fading in mobile radio channel. In this paper, we present two kinds of carrier recovery technique using pilot tone such as TCT(Tone Calibration Technique) and DTCT(Dual Tone Calibration Technique) and analyze these performance both in Rayleigh and Rician fadings. we also evaluate the BER performance of two carrier recovery systems in terms of design parameters such as pilot-to-singnal power ratio, and detection filter-to-pilot filter bandwidth ratio.
Journal of Institute of Control, Robotics and Systems
/
v.7
no.10
/
pp.843-848
/
2001
Most of gimballed inertial navigation systems(GNIS) are calibrated periodically to maintain their inherent accuracy. The existing calibration techniques using the conventional schuler test with the least square method and the multiposition test take a long time and have some problems in procedures. To solve this problem, calibration method using a linear Kalman filter is proposed by us. In this paper, the calibration method by the change of Schuler period is studied in order to improve the calibration performance of the gimballed INS. First of all, it is shown that the observability of Kalman filter is also enhanced the Schuler period is decreased. Simulation results show that the calibration performance using the present scheme is improved according to the decrease of the Schuler period and the calibration time is shortened extremely, too. And our proposed technique shows desirable estimation performance for the g-sensitive errors of inertial sensors in particular.
Journal of the Korean Institute of Telematics and Electronics B
/
v.29B
no.2
/
pp.27-39
/
1992
3 Dimensional measurement system using camera and laser slit-ray is studied. Precise calibration technique in this system is suggested. Calibration is accomplished with calibration die, calibration block and robot. For obtaining calibration parameters, the equations are solved using least square error method from a great many calibration points to reduce measuring error. Continuous measurement is possible for the object which is larger than one frame of camera. The efficiency and usability are proved by applying to the tire profile measuring system which measures tire profile using robot and this system.
Proceedings of the Korean Society of Precision Engineering Conference
/
1991.11a
/
pp.105-109
/
1991
A computer aided flatness calibration system has been developed. Rectangular grids based measurement procedure is proposed with closing error technique. giving advantages over conventional diagonal measurement procedures (‘Union Jack’). A new analysis technique has been developed for flatness evaluation called ‘ETT(Enclose Tilt technique)’, enabling minimum separation definition which is acknowledged as standard term for flatness definition. Practical assessment shows the performance of the developed system.
The calibration of the robot system with a visual sensor consists of robot, hand-to-eye, and sensor calibration. This paper describe a new technique for computing 3D position and orientation of a 3D sensor system relative to the end effect of a robot manipulator in an eye-on-hand robot configuration. When the 3D coordinates of the feature points at each robot movement and the relative robot motion between two robot movements are known, a homogeneous equation of the form AX : XB is derived. To solve for X uniquely, it is necessary to make two robot arm movements and form a system of two equation of the form: A$_1$X : XB$_1$ and A$_2$X = XB$_2$. A closed-form solution to this system of equations is developed and the constraints for solution existence are described in detail. Test results through a series of simulation show that this technique is simple, efficient, and accurate fur hand/eye calibration.
Journal of Institute of Control, Robotics and Systems
/
v.6
no.1
/
pp.51-56
/
2000
This paper presents the characteristics of the dynamic response and calibration technique on a linear variable differential transformer(LVDT). The linear error of the LVDT was proven $\pm$1% in the static calibration and $\pm$0.5% in the dynamic calibration. In this paper, the linearity error generated in the static and dynamic state of the core movement can be eliminated using the correction algorithem of the static and dynamic state derived from the least square linear approximation for the nonlinearity of the curves of direct data fitting and Lagrange polynomials. With the static and dynamic calibration method, the calibration accuracy of the LVDT can be reduced to within $\pm{0.5%.}$.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.