• Title/Summary/Keyword: calibration status

Search Result 92, Processing Time 0.034 seconds

A study on the determination of a representative location for monitoring the dissolved oxygen concentration in a aeration tank of sewage treatment plant (하수처리장 폭기조의 용존산소농도 모니터링 대표지점 선정에 관한 연구)

  • Bang, Seok-Yong;Bum, Bong-Su;Kim, Jin-Han
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.5
    • /
    • pp.389-394
    • /
    • 2019
  • In order to determine the location of average concentration and distribution status of dissolved oxygen in the rectangular aeration tank of the sewage treatment plant was analyzed and the difference of dissolved oxygen concentration was remarkable at each location. Compared with the computational fluid dynamics analysis, it was found that the results were consistent with the measurement results by showing the difference of dissolved oxygen concentration between the locations. Based on the measured data, the representative location of dissolved oxygen in aeration tank was selected by using statistical analysis method and the representative location was expressed in three-dimensional coordinates(LWH : 25%, 50%, 33%) from flow direction and left wall. Also the difference between the dissolved oxygen concentration at the actual measurement location and the average concentration value of the entire aeration tank was founded, and the equations for calibrating the automatic measurement data considering the actual measurement location were calculated.

Performance evaluation of the 76 cm telescope at Kyung Hee Astronomical Observatory (KHAO)

  • Ji, Tae-Geun;Han, Jimin;Ahn, Hojae;Lee, Sumin;Kim, Dohoon;Kim, Kyung Tae;Im, Myungshin;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.49.3-49.3
    • /
    • 2021
  • The 76 cm telescope in Kyung Hee Astronomical Observatory is participating in the small telescope network of the SomangNet project, which started in 2020. Since the installation of the telescope in 1992, the system configuration has been changed several times. The optical system of this telescope has a Ritchey-Chrétien configuration with 76 cm in diameter and the focal ratio is f/7. The mount is a single fork equatorial type and its control system is operated by TheSkyX software. We use a science camera with a 4k × 4k CCD and standard Johnson-Cousins UBVRI filters, which cover a field of view of 23.7 × 23.7 arcmin. We are also developing the Kyung Hee Automatic Observing Software for the 76 cm telescope (KAOS76) for efficient operations. In this work, we present the standard star calibration results, the current status of the system, and the expected science capabilities.

  • PDF

Estimations of River Discharge of the Congo and Orinoco Basins using Gravity-based Remote Sensing Technique

  • Younggyeong Lim;Jooyoung Eom;Kookhyoun Youm;Taehwan Jeon;Ki-Weon Seo
    • Journal of the Korean earth science society
    • /
    • v.45 no.5
    • /
    • pp.456-468
    • /
    • 2024
  • River discharge is a crucial indicator of climate change and requires accurate and continuous estimation for effective water resource management and environmental monitoring. This study used satellite gravimetry data to estimate river discharge in major basins with high discharge volumes, specifically the Congo and Orinoco basins. By enhancing the spatial resolution of gravity data through advanced post-processing techniques, including forward modeling and river routing schemes, we effectively detected changes in the water mass stored within river channels. Additionally, signals from surrounding regions were statistically removed using the Empirical Orthogonal Function (EOF) analysis to isolate river-specific discharge signals. These refined signals were then converted into river discharge data through seasonal calibration using the modeled discharge data. Our results demonstrate that this method yields accurate and reliable discharge estimates comparable to in-situ measurements from gauge stations, even without ground-based surveys such as an Acoustic Doppler Current Profiler (ADCP) field campaigns. This research highlights the significant potential of satellite-based gravity data as an alternative to traditional ground surveys, providing practical information on the hydrological status of regions associated with large-scale river systems.

Status and Prospect of Unmanned, Global Ocean Observations Network (글로벌 무인해양관측 네트워크 현황과 전망)

  • Nam, Sunghyun;Kim, Yun-Bae;Park, Jong Jin;Chang, Kyung-Il
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.19 no.3
    • /
    • pp.202-214
    • /
    • 2014
  • We introduce status and prospect of increasingly utilizing, unmanned, global ocean observing systems, and the global network to integrate, coordinate, and manage the systems. Platforms of the ocean observing system are diversified in order to resolve/monitor the variability occurring at multiple scales in both three-dimensional space and time. Here purpose, development history, and current status of the systems in two kinds - mobile (surface drifter, subsurface float, underwater glider) and fixed platforms (surface and subsurface moorings, bottom mounts), are examined and the increased future uses to produce synergies are envisioned. Simultaneous use of various mobile and fixed platforms is suggested to more effectively design the observing system, with an example of the NSF-funded OOI (Ocean Observations Initiative) program. Efforts are suggested 1) to fill the data gap existing in the deep sea and the Southern Ocean, and toward 2) new global network for oceanic boundary currents, 3) new technologies for existing and new sensors including biogeochemical, acoustic, and optical sensors, 3) data standardization, and 4) sensor calibration and data quality control.

Design of a High-Resolution Integrating Sigma-Delta ADC for Battery Capacity Measurement (배터리 용량측정을 위한 고해상도 Integrating Sigma-Delta ADC 설계)

  • Park, Chul-Kyu;Jang, Ki-Chang;Woo, Sun-Sik;Choi, Joong-Ho
    • Journal of IKEEE
    • /
    • v.16 no.1
    • /
    • pp.28-33
    • /
    • 2012
  • Recently, with mobile devices increasing, as a variety of multimedia functions are needed, battery life is decreased. Accordingly the methods for extending the battery life has been proposed. In order to implement these methods, we have to know exactly the status of the battery, so we need a high resolution analog to digital converter(ADC). In case of the existing integrating sigma-delta ADC, it have not convert reset-time conversion cycle to function of resolution. Because of this reason, all digital values corresponding to the all number of bits will not be able to be expressed. To compensated this drawback, this paper propose that all digital values corresponding to the number of bits can be expressed without having to convert reset-time additional conversion cycle to function of resolution by using a up-down counter. The proposed circuit achieves improved SNDR compared to conventional converters simulation result. Also, this was designed for low power suitable for battery management systems and fabricated in 0.35um process.

Analysis of Soil Erosion Reduction Ratio with Changes in Soil Reconditioning Amount for Highland Agricultural Crops (고랭지 농업의 작물별 객토량 변화에 따른 토양유실 저감 분석)

  • Heo, Sunggu;Jun, ManSig;Park, Sanghun;Kim, Ki-sung;Kang, SungKeun;Ok, YongSik;Lim, Kyoung Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.2
    • /
    • pp.185-194
    • /
    • 2008
  • There is increased soil erosion potential at highland agricultural crop fields because of its topographic characteristics and site-specific agricultural management practices performed at these areas. The agricultural upland fields are usually located at the sloping areas, resulting in higher soil loss, pesticides, and nutrients in case of torrential rainfall events or typhoon, such as 2002 Rusa and 2003 MaeMi. At the highland agricultural fields, the soil reconditioning have been performed every year to decrease damage by continuous cropping and pests. Also it has been done to increase crop productivity and soil fertility. The increased amounts of soil used for soil reconditioning are increasing over the years, causing significant impacts on water quality at the receiving water bodies. In this study, the field investigation was done to check soil reconditioning status for potato, carrot, and cabbage at the Doam-dam watershed. With these data obtained from the field investigation, the Soil and Water Assesment Tool (SWAT) model was used to simulate the soil loss reduction with environment-friendly and agronomically enough soil reconditioning. The average soil reconditioning depth for potato was 34.3 cm, 48.3 cm for carrot, and 31.2 cm for cabbage at the Doam-dam watershed. These data were used for SWAT model runs. Before the SWAT simulation, the SWAT ArcView GIS Patch, developed by the Kangwon National University, was applied because of proper simulation of soil erosion and sediment yield at the sloping watershed, such as the Doam-dam watershed. With this patch applied, the Coefficient of Determination ($R^2$) value was 0.85 and the Nash-Sutcliffe Model Efficiency (EI) was 0.75 for flow calibration. The $R^2$ value was 0.87 and the EI was 0.85 for flow validation. For sediment simulation, the $R^2$ value was 0.91 and the EI was 0.70, indicating the SWAT model predicts the soil erosion processes and sediment yield at the Doam-dam watershed. With the calibrated and validated SWAT for the Doam-dam watershed, the soil erosion reduction was investigated for potato, carrot, and cabbage. For potato, around 19.3 cm of soil were over applied to the agricultural field, causing 146% of more soil erosion rate, approximately 33.3 cm, causing 146% of more soil erosion for carrot, and approximately 16.2 cm, causing 44% of more soil erosion. The results obtained in this study showed that excessive soil reconditioning are performed at the highland agricultural fields, causing severe muddy water issues and water quality degradation at the Doam-water watershed. The results can be used to develop soil reconditioning standard policy for various crops at the highland agricultural fields, without causing problems agronomically and environmentally.

Mastitis Diagnostics by Near-infrared Spectra of Cows milk, Blood and Urine Using SIMCA Classification

  • Tsenkova, Roumiana;Atanassova, Stefka
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1247-1247
    • /
    • 2001
  • Constituents of animal biofluids such as milk, blood and urine contain information specifically related to metabolic and health status of the ruminant animals. Some changes in composition of biofluids can be attributed to disease response of the animals. Mastitis is a major problem for the global dairy industry and causes substantial economic losses from decreasing milk production and reducing milk quality. The purpose of this study was to investigate potential of NIRS combined with multivariate analysis for cow's mastitis diagnosis based on NIR spectra of milk, blood and urine. A total of 112 bulk milk, urine and blood samples from 4 Holstein cows were analyzed. The milk samples were collected from morning milking. The urine samples were collected before morning milking and stored at -35$^{\circ}C$ until spectral analysis. The blood samples were collected before morning milking using a catheter inserted into the carotid vein. Heparin was added to blood samples to prevent coagulation. All milk samples were analyzed for somatic cell count (SCC). The SCC content in milk was used as indicator of mastitis and as quantitative parameter for respective urine and blood samples collected at same time. NIR spectra of blood and milk samples were obtained by InfraAlyzer 500 spectrophotometer, using a transflectance mode. NIR spectra of urine samples were obtained by NIR System 6500 spectrophotometer, using 1 mm sample thickness. All samples were divided into calibration set and test set. Class variable was assigned for each sample as follow: healthy (class 1) and mastitic (class 2), based on milk SCC content. SIMCA was implemented to create models of the respective classes based on NIR spectra of milk, blood or urine. For the calibration set of samples, SIMCA models (model for samples from healthy cows and model for samples from mastitic cows), correctly classified from 97.33 to 98.67% of milk samples, from 97.33 to 98.61% of urine samples and from 96.00 to 94.67% of blood samples. From samples in the test set, the percent of correctly classified samples varied from 70.27 to 89.19, depending mainly on spectral data pretreatment. The best results for all data sets were obtained when first derivative spectral data pretreatment was used. The incorrect classified samples were 5 from milk samples,5 and 4 from urine and blood samples, respectively. The analysis of changes in the loading of first PC factor for group of samples from healthy cows and group of samples from mastitic cows showed, that separation between classes was indirect and based on influence of mastitis on the milk, blood and urine components. Results from the present investigation showed that the changes that occur when a cow gets mastitis influence her milk, urine and blood spectra in a specific way. SIMCA allowed extraction of available spectral information from the milk, urine and blood spectra connected with mastitis. The obtained results could be used for development of a new method for mastitis detection.

  • PDF

Development and Validation of a Breast Cancer Risk Prediction Model for Thai Women: A Cross-Sectional Study

  • Anothaisintawee, Thunyarat;Teerawattananon, Yot;Wiratkapun, Cholatip;Srinakarin, Jiraporn;Woodtichartpreecha, Piyanoot;Hirunpat, Siriporn;Wongwaisayawan, Sansanee;Lertsithichai, Panuwat;Kasamesup, Vijj;Thakkinstian, Ammarin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.16
    • /
    • pp.6811-6817
    • /
    • 2014
  • Background: Breast cancer risk prediction models are widely used in clinical practice. They should be useful in identifying high risk women for screening in limited-resource countries. However, previous models showed poor performance in derived and validated settings. Therefore, we aimed to develop and validate a breast cancer risk prediction model for Thai women. Materials and Methods: This cross-sectional study consisted of derived and validation phases. Data collected at Ramathibodi and other two hospitals were used for deriving and externally validating models, respectively. Multiple logistic regression was applied to construct the model. Calibration and discrimination performances were assessed using the observed/expected ratio and concordance statistic (C-statistic), respectively. A bootstrap with 200 repetitions was applied for internal validation. Results: Age, menopausal status, body mass index, and use of oral contraceptives were significantly associated with breast cancer and were included in the model. Observed/expected ratio and C-statistic were 1.00 (95% CI: 0.82, 1.21) and 0.651 (95% CI: 0.595, 0.707), respectively. Internal validation showed good performance with a bias of 0.010 (95% CI: 0.002, 0.018) and C-statistic of 0.646(95% CI: 0.642, 0.650). The observed/expected ratio and C-statistic from external validation were 0.97 (95% CI: 0.68, 1.35) and 0.609 (95% CI: 0.511, 0.706), respectively. Risk scores were created and was stratified as low (0-0.86), low-intermediate (0.87-1.14), intermediate-high (1.15-1.52), and high-risk (1.53-3.40) groups. Conclusions: A Thai breast cancer risk prediction model was created with good calibration and fair discrimination performance. Risk stratification should aid to prioritize high risk women to receive an organized breast cancer screening program in Thailand and other limited-resource countries.

Estimation of Body Weight Using Body Volume Determined from Three-Dimensional Images for Korean Cattle (한우의 3차원 영상에서 결정된 몸통 체적을 이용한 체중 추정)

  • Jang, Dong Hwa;Kim, Chulsoo;Kim, Yong Hyeon
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.393-400
    • /
    • 2021
  • Body weight of livestock is a crucial indicator for assessing feed requirements and nutritional status. This study was performed to estimate the body weight of Korean cattle (Hanwoo) using body volume determined from three-dimensional (3-D) image. A TOF camera with a resolution of 640×480 pixels, a frame rate of 44 fps and a field of view of 47°(H)×37°(V) was used to capture the 3-D images for Hanwoo. A grid image of the body was obtained through preprocessing such as separating the body from background and removing outliers from the obtained 3-D image. The body volume was determined by numerical integration using depth information to individual grid. The coefficient of determination for a linear regression model of body weight and body volume for calibration dataset was 0.8725. On the other hand, the coefficient of determination was 0.9083 in a multiple regression model for estimating body weight, in which the age of Hanwoo was added to the body volume as an explanatory variable. Mean absolute percentage error and root mean square error in the multiple regression model to estimate the body weight for validation dataset were 8.2% and 24.5kg, respectively. The performance of the regression model for weight estimation was improved and the effort required for estimating body weight could be reduced as the body volume of Hanwoo was used. From these results obtained, it was concluded that the body volume determined from 3-D of Hanwoo could be used as an effective variable for estimating body weight.

Design and Implementation of User Standing Posture Recognition-Based Interaction System Using Multi-Channel Large Area Pressure Sensors

  • Park, HyungSoo;Kim, HoonKi;Kwak, Jaekyung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.3
    • /
    • pp.155-162
    • /
    • 2020
  • Among the fourth industrial revolution technologies, products related to healthcare using IoT and sensors are currently being developed. We design and develop an interaction system based on user standing posture recognition using multi-channel large area pressure sensors in this paper. To this end, first of all we investigate major sensor markets of the sensor industry and review technology trends and the current and future of smart healthcare. Based on this survey, we examine and compare cases developed at home and abroad for multi-channel large-area pressure sensors, which are key components of the system that we want to develop. We recognize the standing posture status of the user through the developed system and experiment with how effective it is actually in user posture calibration and apply the research results to various healthcare devices' medical fields based on this.