• Title/Summary/Keyword: calibration status

Search Result 92, Processing Time 0.034 seconds

Applications of Near Infrared Reflectance Spectroscopy(NIRS) in Forage Evaluation (조사료 가치 평가를 위한 근적외선 분광법(NIRS)의 활용)

  • 박형수;이종경;이효원
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.24 no.1
    • /
    • pp.81-90
    • /
    • 2004
  • Farmers need timely information on the nutritional status of their animals and the nutritive value of pastures and supplementary feeds if they are to apply successfully this existing nutritional information. Near infrared reflectance(NIR) spectroscopy has been used over the last forty years to analyse accurately protein, fiber, and other organic components in animal foods. NIR spectroscopy is a rapid, non-destructive, and non-polluting technology. When properly calibrated, NIR spectroscopy is used successfully with both concentrate and forage feeds. NIR methods predict in vitro digestibility accurately and precisely, and can predict in vivo digestibility at least as well as conventional "wet chemistry" methods such as in vivo digestion or the pepsin-cellulase method, and much more rapidly. NIR technology has been applied to the routine monitoring (through analysis of feces samples) of the nutritional status of cattle and other grazing animals. This report reviews the use of near infrared reflectance(NIR) spectroscopy to monitor the nutritive value of animal feeds and the nutritional status of grazing animals.

THE JAPANSE STATUS OF LABORATORY ACCREDITATION BASED ON FASTENER QUALITY ACT.

  • Aoyagi Tutomu;Imai O Yoshio
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 1998.11a
    • /
    • pp.339-344
    • /
    • 1998
  • Since 1997, JAB (The Japan Accreditation Board for Conformity Assessment) had started the activity of accreditation for the laboratory based on U.S. PL101-592: the Fastener Quality Act that was signed by President Bush on 1990. The number of accredit laboratories are 69 in Japan, 21 in Taiwan, 2 in Korea and 189 in U. S. A, as of 09/10/1998. The JAB accreditation encompasses the requirements of the ISO/IEC Guide 25, and the relevant requirements of ISO 9002. The purpose of ISO/IEC Guide 25, also had been harmonized as JIS Z 9325 'General requirements for the competence of calibration and testing laboratories 'mainly facilitates and promotes acceptance of calibration and test results between countries to avoid barriers to trade through as 'one stop testing'. The features and differences between Guide 25 and ISO 9000 will be clarify in this report.

  • PDF

The Levitation Mass Method: A Precision Mass and Force Measurement Technique

  • Fujii, Yusaku
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.3
    • /
    • pp.46-50
    • /
    • 2008
  • The present status and future prospects of the levitation mass method (LMM), a technique for precision mass and force measurement, are reviewed. In the LMM, the inertial force of a mass levitated using a pneumatic linear bearing is used as the reference force applied to the objects being tested, such as force transducers, materials, or structures. The inertial force of the levitated mass is measured using an optical interferometer. We have modified this technique for dynamic force calibration of impact, oscillation, and step loads. We have also applied the LMM to material testing, providing methods for evaluating material viscoelasticity under an oscillating or impact load, evaluating material friction, evaluating the biomechanics of a human hand, and generating and measuring micro-Newton-level forces.

PRINCIPAL COMPONENTS BASED SUPPORT VECTOR REGRESSION MODEL FOR ON-LINE INSTRUMENT CALIBRATION MONITORING IN NPPS

  • Seo, In-Yong;Ha, Bok-Nam;Lee, Sung-Woo;Shin, Chang-Hoon;Kim, Seong-Jun
    • Nuclear Engineering and Technology
    • /
    • v.42 no.2
    • /
    • pp.219-230
    • /
    • 2010
  • In nuclear power plants (NPPs), periodic sensor calibrations are required to assure that sensors are operating correctly. By checking the sensor's operating status at every fuel outage, faulty sensors may remain undetected for periods of up to 24 months. Moreover, typically, only a few faulty sensors are found to be calibrated. For the safe operation of NPP and the reduction of unnecessary calibration, on-line instrument calibration monitoring is needed. In this study, principal component-based auto-associative support vector regression (PCSVR) using response surface methodology (RSM) is proposed for the sensor signal validation of NPPs. This paper describes the design of a PCSVR-based sensor validation system for a power generation system. RSM is employed to determine the optimal values of SVR hyperparameters and is compared to the genetic algorithm (GA). The proposed PCSVR model is confirmed with the actual plant data of Kori Nuclear Power Plant Unit 3 and is compared with the Auto-Associative support vector regression (AASVR) and the auto-associative neural network (AANN) model. The auto-sensitivity of AASVR is improved by around six times by using a PCA, resulting in good detection of sensor drift. Compared to AANN, accuracy and cross-sensitivity are better while the auto-sensitivity is almost the same. Meanwhile, the proposed RSM for the optimization of the PCSVR algorithm performs even better in terms of accuracy, auto-sensitivity, and averaged maximum error, except in averaged RMS error, and this method is much more time efficient compared to the conventional GA method.

Introduction to Daegwallyeong Wind Turbine Test Site and Field Test Study (대관령 풍력실증단지 및 실증연구 소개)

  • Yoo Neung-Soo;Nam Yun-Soo;Lee Jung-Wan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.5-8
    • /
    • 2005
  • This paper aims to introduce the Daegwallyeong wind turbine test site which is the first official wind turbine test site in Korea. The current status of test site, the characteristics, the projects performed and future plan of this test site are described. The results of wind condition measurements and monitoring system established by the Kangwon National University are presented. The importance of field test is also commented.

  • PDF

Development of Web-based Dosimetry Calibration Program for High Energy Radiation (웹 기반 고 에너지 방사선에 대한 흡수선량 교정 프로그램 개발)

  • Shin Dong Oh;Shin Dong Ho;Kim Sung Hoon;Park Sung Yong;Seo Won Seop;Ahn Hee Kyung;Kang Jin Oh;Hong Seong Eon
    • Progress in Medical Physics
    • /
    • v.16 no.3
    • /
    • pp.116-124
    • /
    • 2005
  • Absorbed dose dosimetry protocols of high energy photon and electron beams, which are widely used and based on an air kerma calibration factors, have somewhat complex formalism and limitations for improving dosimetric accuracy due to uncertainty of the physical parameters used. Recently the IAEA and the AAPM published the absorbed dose to water-based dosimetry protocol. In this work web-based dose calibration program for IAEA TRS-398 and AAPM TG-51 protocols were developed. This program developed using the Visual C$\#$ language can be used in the internet. User selectable dosimetry protocol on the web allows the absorbed dose to water data of the two protocols at a reference point to be easily compared, and enables to conveniently manage and understand the current status of the dosimetry calibration performed at participating institutions in korea. This program and the resultant database from the web-based calibration can be useful in developing new dosimetry protocols in Korea.

  • PDF

A Study on the Present Status of the Quality Evaluation Capability of Domestic Paper Industry -A Case Study for Fine Paper Industry (국내 제지산업의 품질평가 실태연구-백상지업체를 중심으로-)

  • 이학래;윤혜정;김태영;조중연
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.1
    • /
    • pp.94-100
    • /
    • 2000
  • This study was carried out to understand the present status of the quality evaluation capability of domestic fine paper industry. Six light weight coated papers and one wood containing printing and writing paper with similar basis weights were produced by seven paper companies and their properties were evaluated at four different testing laboratories of domestic fine paper mills. Paper properties including basis weight , thickness , tensile, tear , brightness , opacity, etc were examined , and the repeat ability and reproducibility of the test results were analyzed. Results showed that repeatability of the measurements within the laboratory was satisfactory . Reproducibility of the measurements between laboratories, however, was not satisfactory. This showed that strict implementation of the standard testing methods and periodic calibration of testing equipments should be made to improve quality evaluation capability of domestic fine paper industry.

  • PDF

CALIBRATION OF STELLAR PARAMETERS OF 85 PEG SYSTEM

  • Bach, Kiehunn;Kim, Yong-Cheol;Demarque, Pierre
    • Journal of Astronomy and Space Sciences
    • /
    • v.24 no.1
    • /
    • pp.31-38
    • /
    • 2007
  • We have investigated the evolutionary status of 85 Peg within the framework of standard evolutionary theory. 85 Peg has been known to be a visual and spectroscopic binary system in the solar neighborhood. In spite of the accurate information of the total mass (${\sim}1.5M_{\odot}$) and the distance (${\sim}12pc$) from the HIPPARCOS parallax, it has been undetermined an individual mass, therefore the evolved status of the system. Moreover, the coupled uncertainties of chemical composition and age, make matters worse in predicting an evolutionary status of the system. Nevertheless, we computed the various possible models for 85 Peg, and then calibrated stellar parameters by adjusting to the recent observational data. Our modelling computation has included recently updated input physics and stellar theory such as opacity, equation of state, and chemical diffusion. Through a statistical assessment, we have derived a confident parameter set as the best solution which minimized $X^{2}$ within the observational error domain. Most of all, we found that 85 Peg is not a binary system but a triple system with an unseen companion 85 Peg $B_{b}\;{\sim}0.16M_{\odot}$. The aim of the present paper is (1) to provide a complete modelling of the stellar system based on the evolutionary theory, and (2) to constrain the physical dimensions such as mass, metallicity and age.

Image Processing Methods for Measurement of Lettuce Fresh Weight

  • Jung, Dae-Hyun;Park, Soo Hyun;Han, Xiong Zhe;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • v.40 no.1
    • /
    • pp.89-93
    • /
    • 2015
  • Purpose: Machine vision-based image processing methods can be useful for estimating the fresh weight of plants. This study analyzes the ability of two different image processing methods, i.e., morphological and pixel-value analysis methods, to measure the fresh weight of lettuce grown in a closed hydroponic system. Methods: Polynomial calibration models are developed to relate the number of pixels in images of leaf areas determined by the image processing methods to actual fresh weights of lettuce measured with a digital scale. The study analyzes the ability of the machine vision- based calibration models to predict the fresh weights of lettuce. Results: The coefficients of determination (> 0.93) and standard error of prediction (SEP) values (< 5 g) generated by the two developed models imply that the image processing methods could accurately estimate the fresh weight of each lettuce plant during its growing stage. Conclusions: The results demonstrate that the growing status of a lettuce plant can be estimated using leaf images and regression equations. This shows that a machine vision system installed on a plant growing bed can potentially be used to determine optimal harvest timings for efficient plant growth management.

Development of Frequency Dependent Type Apex-Locator Improvementation by Auto-calibration Using Impedance Difference (주파수 의존형 전자근관장측정기 개발 및 임피던스차를 이용한 자동보정에 의한 성능향상)

  • Nam, K.C.;Kim, S.C.;Kim, D.W.;Lee, S.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.399-402
    • /
    • 1997
  • It is important to find a accurate root canal length or successful endodontic therapy. By X-ray method takes a long time and difficult in a curved canal. After developed electronic apex locator has allowed to measure the root canal length with easy, in a short time also in a curved canal. But most electronic apex locators have the disadvantage which is too short reading or sometimes the measurement itself becomes impossible if there are electrolytes in the canal. To overcome this drawback, impedance ratio method has been developed. In this study, we have developed frequency dependent electronic apex locator to minimize the interference of electrolytes. And based on that also some error in clinic use, we added the other method. Difference of two signals which are used in calculation of impedance ratio was can be represent the status of root canal fluid. As a result, using impedance ratio method and auto-calibration by voltage difference method can reduce the measurement error.

  • PDF