• 제목/요약/키워드: calibration parameters

검색결과 912건 처리시간 0.027초

Boresight calibration을 이용한 외부표정요소 산출에 관한 연구 (A study on the transformation of EO parameters using Boresight calibration)

  • 박수영;윤여상;김준철;정주권;주영은
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2003년도 추계학술발표회 논문집
    • /
    • pp.129-134
    • /
    • 2003
  • Mobile Mapping System needs system calibration of multi sensors. System calibration is defined as determination of spatial and rotational offsets between the sensors. Especially, EO parameters of GPS/INS require knowledge of the calibration to camera frame. The calibration parameters must be determined with the highest achievable accuracy in order to get 3D coordinate points in stereo CCD images. This study applies Boresight calibration for the calibration between GPS/INS and camera, and estimates the Performance of the calibration.

  • PDF

로봇 캘리브레이션을 위한 모델 파라미터의 관측성 연구 (A Study on Observability of Model Parameters for Robot Calibration)

  • 범진환;양수상;임생기
    • 한국정밀공학회지
    • /
    • 제14권4호
    • /
    • pp.64-71
    • /
    • 1997
  • Objective of calibration is to find out the accurate kinematic relationships between robot joint angles and the position of the end-effector by estimating accurate model parameters defining the kinematic function. Estimating the model parameters requires measurement of the end-effector position at a number of different robot configurations. This paper studies the implication of measurement configurations in robot calibration. For selecting appropriate measurement configurations in robot calibration, an index is defined to measure the observability of the model parameters with respect to a set of robot configurations. It is found that, as the observability index of the selected measurement configurations increase the attribution of the position errors to the parameter errors becomes dominant while the effects of the measurement and unmodeled errors are less significant; consequently better estimation of parameter errors is expected. To demonstrate the implication of the observability measure in robot calibration, computer simulations are performed and their results are discussed.

  • PDF

위치 정밀도 향상을 위한 관절강성 파라미터 포함 로봇 캘리브레이션 (Robot Calibration with Joint Stiffness Parameters for the Enhanced Positioning Accuracy)

  • 강희준;신성원;노영식;서영수;임현규;김동혁
    • 제어로봇시스템학회논문지
    • /
    • 제14권4호
    • /
    • pp.406-410
    • /
    • 2008
  • This paper presents a new robot calibration algorithm with joint stiffness parameters for the enhanced positioning accuracy of industrial robot manipulators. This work is towards on-going development of an industrial robot calibration software which is able to identify both the kinematic and non-kinematic robot parameters. In this paper, the conventional kinematic calibration and its important considerations are briefly described first. Then, a new robot calibration algorithm which simultaneously identifies both the kinematic and joint stiffness parameters is presented and explained through a computer simulation with a 2 DOF manipulator. Finally, the developed algorithm is implemented to Hyundai HX165 robot and its resulting improvement of the positioning accuracy is addressed.

Determination of Identifiable Parameters and Selection of Optimum Postures for Calibrating Hexa Slide Manipulators

  • Park, Jong-Hyuck;Kim, Sung-Gaun;Rauf, Abdul;Ryu, Je-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2737-2742
    • /
    • 2003
  • Kinematic calibration enhances absolute accuracy by compensating for the fabrication tolerances and installation errors. Effectiveness of calibration procedures depends greatly on the measurements performed. While the Cartesian postures are measured completely, all of the geometric parameters can be identified to their true values. With partial pose measurements, however, few geometric parameters may not be identifiable and effectiveness of the calibration results may vary significantly within the workspace. QR decomposition of the identification Jacobian matrix can reveal the non-identifiable parameters. Selecting postures for measurement is also an important issue for efficient calibration procedure. Typically, the condition number of the identification Jacobian is minimized to find optimum postures. This paper investigates identifiable parameters and optimum postures for four different calibration procedures - measuring postures completely with inverse kinematic residuals, measuring postures completely with forward kinematics residuals, measuring only the three position components, and restraining the mobility of the end-effector using a constraint link. The study is performed for a six degree-of-freedom fully parallel HexaSlide type paralle manipulator, HSM. Results verify that all parameters are identifiable with complete posture measurements. For the case of position measurements, one and for the case of constraint link, three parameters were found non-identifiable. Optimal postures showed the same trend of orienting themselves on the boundaries of the search space.

  • PDF

A parameter calibration method for PFC simulation: Development and a case study of limestone

  • Xu, Z.H.;Wang, W.Y.;Lin, P.;Xiong, Y.;Liu, Z.Y.;He, S.J.
    • Geomechanics and Engineering
    • /
    • 제22권1호
    • /
    • pp.97-108
    • /
    • 2020
  • The time-consuming and less objectivity are the main problems of conventional micromechanical parameters calibration method of Particle Flow Code simulations. Thus this study aims to address these two limitation of the conventional "trial-and-error" method. A new calibration method for the linear parallel bond model (CM-LPBM) is proposed. First, numerical simulations are conducted based on the results of the uniaxial compression tests on limestone. The macroscopic response of the numerical model agrees well with the results of the uniaxial compression tests. To reduce the number of the independent micromechanical parameters, numerical simulations are then carried out. Based on the results of the orthogonal experiments and the multi-factor variance analysis, main micromechanical parameters affecting the macro parameters of rocks are proposed. The macro-micro parameter functions are ultimately established using multiple linear regression, and the iteration correction formulas of the micromechanical parameters are obtained. To further verify the validity of the proposed method, a case study is carried out. The error between the macro mechanical response and the numerical results is less than 5%. Hence the calibration method, i.e., the CM-LPBM, is reliable for obtaining the micromechanical parameters quickly and accurately, providing reference for the calibration of micromechanical parameters.

단일 바퀴 구동 캐스터 기반 모바일 로봇의 캘리브레이션 (Calibration of Mobile Robot with Single Wheel Powered Caster)

  • 김형철;박수한;박재흥
    • 로봇학회논문지
    • /
    • 제17권2호
    • /
    • pp.183-190
    • /
    • 2022
  • Accurate kinematic parameters of mobile robots are essential because inaccurate kinematic model produces considerable uncertainties on its odometry and control. Especially, kinematic parameters of caster type mobile robots are important due to their complex kinematic model. Despite the importance of accurate kinematic parameters for caster type mobile robots, few research dealt with the calibration of the kinematic model. Previous study proposed a calibration method that can only calibrate double-wheeled caster type mobile robot and requires direct-measuring of robot center point and distance between casters. This paper proposes a calibration method based on geometric approach that can calibrate single-wheeled caster type mobile robot with two or more casters, does not require direct-measuring, and can successfully acquire all kinematic parameters required for control and odometry. Simulation and hardware experiments conducted in this paper validates the proposed calibration method and shows its performance.

2014~2015 연속가뭄을 고려한 SWAT 수질 매개변수 보정 (Calibration of Water Quality Parameters in SWAT Considering Continuous Drought Periods 2014~2015)

  • 김다래;이지완;정충길;김성준
    • 한국농공학회논문집
    • /
    • 제60권1호
    • /
    • pp.11-20
    • /
    • 2018
  • This study is to calibrate the SWAT (Soil and Water Assessment Tool) water quality of SS (Suspended Solid), T-P (Total Phosphorus), and T-N (Total Nitrogen) by focusing on 2014~2015 drought periods and identify the important parameters. For Gongdo watershed ($366.5km^2$), the SWAT was calibrated for 2 cases of 2002~2006 normal year focusing calibration and 2014~2015 drought focusing calibration respectively. The parameters of N_UPDIS (Nitrogen uptake distribution parameter) and CMN (Rate factor for humus mineralization of active organic nutrients) played important roles for T-N calibration during drought periods. The SWAT SS, T-N, and T-P average $R^2$ (Coefficient of determination) results by focusing on 2014~2015 drought periods calibration showed 0.71, 0.65 and 0.62 while 2002~2006 normal year focusing calibration showed 0.63, 0.58 and 0.50 respectively. Also SWAT SS, T-N, and T-P model efficiency NSE (Nash-Sutcliffe efficiency) results by focusing on drought period (2014~2015) calibrated showed 0.76, 0.77, 0.87 respectively. Even though the SS, T-P parameters were unchanged during the calibration, the SS and T-P results were improved by the hydrological parameters (SCS-CN, SOL_K, SLSOIL) during the drought periods. The SWAT water quality calibration needs to be considered for the movement of SS and nutrients transport especially focusing on the drought characteristics.

인공위성의 궤도상에서 자세제어계 센서 보정 (On-Orbit AOCS Sensor Calibration of Spacecraft)

  • 용기력;이선호;오시환;방효충;이승우
    • 항공우주기술
    • /
    • 제5권2호
    • /
    • pp.90-101
    • /
    • 2006
  • 자세제어계 센서 보정알고리즘을 이용하여 자이로와 별 추적기의 보정 파라미터를 추정하였다. 보정알고리즘은 칼만필터로 구현하였다. 자이로의 파라미터를 추정하기 위해서는 보정기동이 필요하며, 별 추적기의 요구조건 내에서 보정기동을 수행하였다. 보정기동 동안에 별 추적기가 태양, 지구, 달에 대해서 영향을 받는지를 분석을 하였다. 또한 별 추적기를 보정하기 위해서는 카메라 영상 정보를 이용하였다. 이러한 카메라 영상 정보는 지상 제어점과 인공위성의 궤도 정보를 이용하여 모사하였으며, 별 추적기 보정 파라미터 추정의 정밀도는 카메라 영상 정보의 정밀도에 따라 다르다.

  • PDF

New Initialization method for the robust self-calibration of the camera

  • Ha, Jong-Eun;Kang, Dong-Joong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.752-757
    • /
    • 2003
  • Recently, 3D structure recovery through self-calibration of camera has been actively researched. Traditional calibration algorithm requires known 3D coordinates of the control points while self-calibration only requires the corresponding points of images, thus it has more flexibility in real application. In general, self-calibration algorithm results in the nonlinear optimization problem using constraints from the intrinsic parameters of the camera. Thus, it requires initial value for the nonlinear minimization. Traditional approaches get the initial values assuming they have the same intrinsic parameters while they are dealing with the situation where the intrinsic parameters of the camera may change. In this paper, we propose new initialization method using the minimum 2 images. Proposed method is based on the assumption that the least violation of the camera’s intrinsic parameter gives more stable initial value. Synthetic and real experiment shows this result.

  • PDF

물체의 운동패턴을 이용한 로보트 팔의 자기보정 (Self-Calibration of a Robot Manipulator by Using the Moving Pattern of an Object)

  • Young Chul Kay
    • 전자공학회논문지B
    • /
    • 제32B권5호
    • /
    • pp.777-787
    • /
    • 1995
  • This paper presents a new method for automatically calibrating robot link (Kinematic) parameters during the process of estimating motion parameters of a moving object. The motion estimation is performed based on stereo cameras mounted on the end-effector of a robot manipulator. This approach significantly differs from other calibration approaches in that the calibration is achieved by simply observing the motion of the moving object (without resorting to any other external calibrating tools) at numerous and widely varying joint-angle configurations. A differential error model, which expresses the measurement errors of a robot in terms of robot link parameter errors and motion parameters, is developed. And then a measurement equation representing the true measurement values is derived. By estimating the above two kinds of parameters minimizing the difference between the measurement equations and the true moving pattern, the calibration of the robot link parameters and the estimation of the motion parameters are accomplished at the same time.

  • PDF