• Title/Summary/Keyword: calibration matching

Search Result 135, Processing Time 0.036 seconds

Development of Stereocopic-PIV and its Application to the Measurement of the Near Wake of a Circular Cylinder (Stereocopic-PIV 개발과 원주근접 후류 계측)

  • Doh, D.H.;Kim, D.H.;Cho, G.R.;Lee, W.J.;Pyun, Y.B.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.555-559
    • /
    • 2001
  • A new stereoscopic PIV is developed using two CCD cameras, stereoscopic photogrammetry, and a 3D-PTV principle. The wake of a circular cylinder is measured by the developed stereoscopic PIV technique. The B mode vortical structure of the wake over the Reynolds number 300 is clearly seen by the developed technique. The arrangement of the two cameras is based on angular position. The calibration of cameras and the pair-matching of the three-dimensional velocity vectors are based on 3D-PTV technique.

  • PDF

Development of a Stereoscopic PTV (스테레오 PTV법의 개발)

  • Doh Deog Hee;Lee Won Je;Cho Yong Beom;Pyeon Yong Beom
    • Journal of the Korean Society of Visualization
    • /
    • v.1 no.1
    • /
    • pp.92-97
    • /
    • 2003
  • A new Stereoscopic PTV was developed using two CCD cameras, stereoscopic photogrammetry based on a 3D-PTV principle. Virtual images were produced for the benchmark test of the constructed Stereoscopic PTV technique. The arrangement of the two cameras was based on angular position. The calibration of cameras and the pair-matching of the three-dimensional velocity vectors were based on the Genetic Algorithm based 3D-PTV technique. The constructed Stereoscopic PTV technique was tested on the standard images of the impinged jet proposed by VSJ. The results obtained by the constructed system showed good agreements with the original data.

  • PDF

The Development of a Stereo vision algorithm for Height Measurement of Ball Peak Point of BGA Device (BGA 소자의 볼 정점 높이 측정을 위한 스테레오 비젼 알고리즘 개발)

  • Lee, Sang-Sin;Park, Young-Soon;Kim, Joon-Seek;Joo, Hyo-Nam
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.431-436
    • /
    • 2005
  • In this paper, We proposed the stereo image modeling using 2-dimensional images captured by the high resolution cameras to inspect the ball defects of BGA(Ball Grid Array) device. The proposed algorithm consists of the package/ball area extraction part, the FOV(Field of View) calibration part, the top point matching part, and ball height measurement part, In the package/ ball area extraction part, the package and ball areas are separately extracted in a left and right image by the extraction algerian. Through the experiment, we draw out the result.

  • PDF

Design and Analysis of Square Beam Type Piezoelectric Vibrating Gyroscope (압전세라믹을 이용한 사각보형 진동자이로의 설계 및 성능분석)

  • 이정훈;박연규;이종원
    • Journal of KSNVE
    • /
    • v.5 no.3
    • /
    • pp.403-411
    • /
    • 1995
  • Square beam type piezoelectric vibrating gyro is developed for the measurement of angular velocity, which is compact, small in size and mass- producible. It features that three pieces of piezoelectric ceramics and bonded onto one face of equilateral square bar type gyro head. Two of them are used as sentuators which drive the gyro head and measure Coriolis force. The third piece is used for the feedback signal in order to resonate the gyro head and measure Coriolis force. The third piece is used for the feedback signal in order to resonate the gyro head with its fundamental natural frequency. Matching two fundamental natural frequencies in the gyro head with its driving frequency is found critical in the design of vibration gyro. Calibration results show that the vibrating gyro developed has the dynamic characteristics of first-order system within the frequency range of interest, which can be easily compensated by a lead compensator.

  • PDF

Image-based Structure Tracking (영상기반 구조물 트래킹)

  • Han, Dong-Yeob
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2011.11a
    • /
    • pp.131-132
    • /
    • 2011
  • Image-based survey can be performed for a floating structure using the hydraulic model tests and empirical methods. I extracted the frame images from a digital camcoder movies and found the corner points for image matching. In the future, we will try the movie acquisition in the improved lab environment for a precise result.

  • PDF

A Capacitor Mismatch Error Cancelation Technique for High-Speed High-Resolution Pipeline ADC

  • Park, Cheonwi;Lee, Byung-Geun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.4
    • /
    • pp.161-166
    • /
    • 2014
  • An accurate gain-of-two amplifier, which successfully reduces the capacitor mismatch error is proposed. This amplifier has similar circuit complexity and linearity improvement to the capacitor error-averaging technique, but operates with two clock phases just like the conventional pipeline stage. This makes it suitable for high-speed, high-resolution analog-to-digital converters (ADCs). Two ADC architectures employing the proposed accurate gain-of-two amplifier are also presented. The simulation results show that the proposed ADCs can achieve 15-bit linearity with 8-bit capacitor matching.

High-Resoultion Stereoscopic PTV (고해상 스테레오PTV)

  • Doh D. H.;Lee W. J.;Cho Y. B.;Pyeon Y. B.;Jang S. W.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.511-512
    • /
    • 2002
  • A new stereoscopic PTV was developed using two CCD cameras, stereoscopic photogrammetry based on a 3D-PTV principle. The arrangement of the two cameras was based on angular position. The calibration of cameras and the pair-matching of the three-dimensional velocity vectors were based on Genetic Algorithm based 3D-PTV technique. The constructed Stereoscopic W technique was tested on the standard images of the impinged jet proposed by VSJ. The results on the turbulent properties of the jet obtained by the constructed system showed a good agreement with the original LES data.

  • PDF

The performance improvement of the volumetric interferometer with multi-CCDs (다중 CCD를 이용한 부피 간섭계의 성능 개선)

  • 주지영;이혁교;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.268-271
    • /
    • 2003
  • The Volumetric Interferometer using two spherical wavefronts emitted from the ends of two single mode fibers has been suggested to measure 3-dimensional absolute coordinates. In this paper, we try to improve the performance of the volumetric interferometer using multi-CCDs. We get coordinates matching matrixes between CCDs and can obtain more information in the space with multi-CCDs. Also we find out the best arrangement of multi-CCDs by computer simulations. In the simulation we can know that it will be better to increase the distance between CCDs to improve performance. For the performance test, we do a repeatability test, a comparison test with 2-D stage and the self-calibration using artifact.

  • PDF

Embedding of Objects Using SFM Analysis in Synthetic Image Sequences (합성영상에서의 이동물체의 SFM분석을 통한 물체의 삽입)

  • 최경업;김용철
    • Proceedings of the IEEK Conference
    • /
    • 2000.11c
    • /
    • pp.181-184
    • /
    • 2000
  • This paper presents an experimental system, where an object extracted from an image sequence is embedded into the desired position in a scene. First, a moving object is detected and the 3-D structure is obtained by SFM analysis of comer trajectories. We constrained the motion to translational motion only. Extracted objects are classified by matching with 3-D models and then the structure of the occluded part is restored. Camera calibration is performed for the background scene which will embed the object. Finally, the object is embedded into the scene. In the experiments, we used synthetic image sequences generated with OpenGL library for easy evaluation of the 3-D structure estimation.

  • PDF

Development of Algorithm or Depth Extraction in Stereo Endoscopic Image (스테레오 내시경 영상의 깊이정보추출 알고리즘 개발)

  • Lee, S.H.;Kim, J.H.;Hwang, D.S.;Song, C.G.;Lee, Y.M.;Kim, W.K.;Lee, M.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.142-145
    • /
    • 1997
  • This paper presents the development of depth extraction algorithm or the 3D Endoscopic Data using a stereo matching method and depth calculation. The purpose of other's algorithms is to reconstruct 3D object surface and make depth map, but a one of this paper is to measure exact depth information on the base of [cm] from camera to object. For this, we carried out camera calibration.

  • PDF