• Title/Summary/Keyword: calibration coefficients

Search Result 325, Processing Time 0.055 seconds

Full angle range pressure coefficient maps of five-hole probe and new calibration coefficients (5공프로브의 전 각도 범위 압력계수 지도와 새로운 보정계수)

  • Kim, Jin-Gwon;Gang, Sin-Hyeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.11
    • /
    • pp.1437-1448
    • /
    • 1997
  • Pressures of a five-hole probe were measured for a full range of yaw and pitch angles and complete pressure coefficient maps were obtained. Based on these maps, various features of five-hole probe pressures were revealed and new five-hole probe calibration coefficients were devised. The new calibration coefficients show non-diverging characteristics for any flow direction and one-to-one correspondence for a wide range of flow angles. These calibration coefficients expand the valid flow angle range of five-hole probe calibration by .+-.10 degrees and complement a critical defect of five-hole probe zone-division calibration method which has not been known yet. Moreover new non-diverging calibration coefficients have advantages in nulling methods, too.

Calibration of QUAL2E Reaction Coefficients by the Influence Coefficient Algorithm (영향계수(影響係數)를 이용한 QUAL2E 모형의 반응계수(反應係數) 추정(推定))

  • Jun, Kyung Soo;Lee, Kil Seong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.163-176
    • /
    • 1993
  • A methodology based on the influence coefficient algorithm was established for the optimal calibration of QUAL2E reaction coefficients. It was applied to the stream sections from the Chungju Dam to the downstream end of the South Han River. A water budget analysis using the monthly records of reservoir inflows and outflows in 1990 was made to determine tributary inflows. Estimated tributary inflows were used, together with the monthly records of water quality measurements in 1990, for the calibration of reaction coefficients. Simulated quality constituents were chl.a. nitrogen cycles, phosphorus cycles. BOD and DO. A sensitivity analysis was made to determine significant reaction coefficients, and as a result 11 reaction coefficients were selected as calibration parameters. The influence coefficient algorithm applied to the calibration of QUAL2E reaction coefficients proved to be a useful one yielding a rapid convergence. Each calibration parameter converged to an optimum value within 3 iterations.

  • PDF

OSMI ocean color products with updated cross-calibration coefficients

  • Lee S. G.;Kim Y. S.
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.494-497
    • /
    • 2004
  • To date the KOMPSAT OSMI(Ocean Scanning Multi-spectral Imager) data have been widely used in natural disaster monitoring such as Typhoon, Asian Dust, Red Tide, and Forest Fire. Quantitative analyses related to the marine ecosystem have been delayed because they require good quality of data through Cal/Val activities. To resolve such problem, KARI performed the OSMI crosscalibration study with SeaWiFS team. In this study, we will demonstrate the OSMI ocean color products with updated cross-calibration coefficients and compare them to the previous cross-calibration results.

  • PDF

Experimental investigation of flow parameters influencing the calibration of five-hole probes (5공프로우브의 보정에 영향을 주는 유동변수들에 대한 실험적 연구)

  • Lee, Sang-U;Yun, Tae-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.5
    • /
    • pp.637-649
    • /
    • 1997
  • Effects of cone angle, pressure-hole orientation and Reynolds number on the five-hole probe calibration have been investigated for eight large-scale conical five-hole probes, which have either perpendicular pressure holes or forward-facing pressure holes for the cone angles of 45 deg, 60 deg, 75 deg and 90.deg. Pitch and yaw angles are changed from -40 deg to +40 deg with an interval of 5 deg, respectively, when the probe Reynolds numbers are 1.77*10$^{4}$, 3.53*10$^{4}$ and 7.06*10$^{4}$. The result shows that larger cone angle results in more sensitive changes in the calibration coefficients. In the case that the cone angle is 45 deg, the pitch-angle and yaw-angle coefficients of the five-hole probe with the perpendicular pressure holes show a very different trend compared with those of the five-hole probe with the forward-facing pressure holes. On the other hand, when the cone angle is more than 60 deg, each calibration coefficient is nearly independent of the pressure-hole orientation. Additionally, the effects of the Reynolds number on the calibration coefficients are also reported in detail.

PROTOTYPE ALGORITHM OF RADIOMETRIC CALIBRATION FOR IR CHANNELS ON GOES-12

  • Chang Ki-Ho;Oh Tae-Hyung;Ahn Myung-Hwan
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.691-693
    • /
    • 2005
  • The prototype of the radiometric calibration algorithm, including the correction of scan mirror's angle, has been developed for the stationary meteorological sensor, firstly in Korea. We use this system on GOES-12 to evaluate two coefficients, slope and intercept. The evaluated coefficients show good agreement with the NESDIS's results for the five-case data. The calculated coefficients have been applied to the conversion from the measured counts to the radiance and the converting methods according to the scanning are investigated to enhance the radiometric accuracy.

  • PDF

Examination of Cross-calibration Between OSMI and SeaWiFS: Comparison of Ocean Color Products

  • Lee, Sun-Gu;Kim, Yong-Seung
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.209-215
    • /
    • 2002
  • Much effort has been made in the radiometric calibration of the ocean scanning multispectral imager (OSMI) since after the successful launch of KOMPSAT-1 in 1999. A series of calibration coefficients for OSMI detectors were obtained in collaboration with the NASA Sensor Intercomparison and Merger for Biological and Interdisciplinary (SIMBIOS) project office. In this study, we compare the OSMI level-2 products (e.g., chlorophyll-a concentration) calculated from the NASA cross-calibration coefficients with the SeaWiFS counterparts. Sample study areas are some of diagonostic data sites recommended by the SIMBIOS working group. We will present the preliminary results of this comparative study.

  • PDF

Examination of Cross-calibration Between OSMI and SeaWiFS: Comparison of Ocean Color Products

  • Kim, Yong-Seung;Lee, Sun-Gu
    • Korean Journal of Remote Sensing
    • /
    • v.19 no.3
    • /
    • pp.201-208
    • /
    • 2003
  • Much effort has been made in the radiometric calibration of the ocean scanning multispectral imager (OSMI) since after the successful launch of KOMPSAT-1 in 1999. A series of calibration coefficients for OSMI detectors were obtained in collaboration with the NASA Sensor Intercomparison and Merger for Biological and Interdisciplinary (SIMBIOS) project office. In this study, we ompare the OSMI level-2 products (e.g., chorophyll-a concentration) calculated from the NASA cross-calibration coefficients with the SeaWiFS counterparts. Sample study areas are some of diagonostic data sites recommended by the SIMBIOS working group. Results of this study show that the OSMl-derived chlorophyll-a concentration agrees well with the SeaWiFS counterpart in Case 1 water; however, differences become larger in Case 2 water.

Pitfall in calibration development - "chance correlation + wishful thinking" - an example of pH determination in grass silages

  • Tillmann, Peter;Horst, Hartmut
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1275-1275
    • /
    • 2001
  • The pH value of grass silages is one important parameter to determine the quality of the forages. In an attempt to use NIRS spectra taken for other quality parameter of grass silage it has been shown that a good correlation between NIR spectra of the dried forage and pH value of the fresh forage could be determined. Further investigations revealed that the B coefficients of the pH value calibration were almost the same as the B coefficients of the sugar calibration multiplied with -1. And indead the pH value - in the fresh sample material - of the calibration set is strongly correlated with the sugar concentration - in the dried sample material. It is concluded that next to scientific tools in research the scientist and the user of NTRS equippment has to scrutinze his own work. Examples are given. NIRS is a powerfull technique, but pitfalls are present in surplus.

  • PDF

Camera Calibration and Barrel Undistortion for Fisheye Lens (차량용 어안렌즈 카메라 캘리브레이션 및 왜곡 보정)

  • Heo, Joon-Young;Lee, Dong-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1270-1275
    • /
    • 2013
  • A lot of research about camera calibration and lens distortion for wide-angle lens has been made. Especially, calibration for fish-eye lens which has 180 degree FOV(field of view) or above is more tricky, so existing research employed a huge calibration pattern or even 3D pattern. And it is important that calibration parameters (such as distortion coefficients) are suitably initialized to get accurate calibration results. It can be achieved by using manufacturer information or lease-square method for relatively narrow FOV(135, 150 degree) lens. In this paper, without any previous manufacturer information, camera calibration and barrel undistortion for fish-eye lens with over 180 degree FOV are achieved by only using one calibration pattern image. We applied QR decomposition for initialization and Regularization for optimization. With the result of experiment, we verified that our algorithm can achieve camera calibration and image undistortion successfully.