• 제목/요약/키워드: calibration coefficient

검색결과 686건 처리시간 0.029초

오염총량관리지역내 소하천에 대한 BASINS 4.0 및 WinHSPF의 적용과 유전알고리즘을 이용한 매개변수의 보정 (Application of BASIN 4.0 and WinHSPF to a Small Stream in Total Water Pollution Load Management Area and Calibration of Model Parameter using Genetic Algorithm)

  • 조재현;윤승진
    • 환경영향평가
    • /
    • 제21권1호
    • /
    • pp.161-169
    • /
    • 2012
  • Recently various attempts have been made to apply HSPF model to calculate runoff and diffuse pollution loads of stream and reservoir watersheds. Because the role of standard flow is very important in the water quality modelling of Total Water Pollution Load Management, HSPF was used as a means of estimating standard flow. In this study, BASINS 4.0 and WinHSPF was applied to the Gomakwoncheon watershed, genetic algorithm(GA) and influence coefficient algorithm were used to calibrate the runoff parameters of the WinHSPF. The objective function is the sum of the squares of the normalized residuals of the observed and calculated flow and it is optimized using GA. Estimates of the optimum runoff parameters are made at each iteration of the influence coefficient algorithm. The calibration results showed a relatively good correspondence between the observed and the calculated values. The standard flow(Q275) of the Gomakwoncheon watershed was estimated using the ten years of weather data.

Absolute Radiometric Calibration for KOMPSAT-3 AEISS and Cross Calibration Using Landsat-8 OLI

  • Ahn, Hoyong;Shin, Dongyoon;Lee, Sungu;Choi, Chuluong
    • 한국측량학회지
    • /
    • 제35권4호
    • /
    • pp.291-302
    • /
    • 2017
  • Radiometric calibration is a prerequisite to quantitative remote sensing, and its accuracy has a direct impact on the reliability and accuracy of the quantitative application of remotely sensed data. This paper presents absolute radiometric calibration of the KOMPSAT-3 (KOrea Multi Purpose SATellite-3) and cross calibration using the Landsat-8 OLI (Operational Land Imager). Absolute radiometric calibration was performed using a reflectance-based method. Correlations between TOA (Top Of Atmosphere) radiances and the spectral band responses of the KOMPSAT-3 sensors in Goheung, South Korea, were significant for multispectral bands. A cross calibration method based on the Landsat-8 OLI was also used to assess the two sensors using near simultaneous image pairs over the Libya-4 PICS (Pseudo Invariant Calibration Sites). The spectral profile of the target was obtained from EO-1 (Earth Observing-1) Hyperion data over the Libya-4 PICS to derive the SBAF (Spectral Band Adjustment Factor). The results revealed that the TOA radiance of the KOMPSAT-3 agree with Landsat-8 within 5.14% for all bands after applying the SBAF. The radiometric coefficient presented here appears to be a good standard for maintaining the optical quality of the KOMPSAT-3.

KRISS에서 수행된 음향관련 교정 및 시험 동향 (Tendency of Calibration and Test for Acoustic Field in KRISS)

  • 서재갑;권휴상;정성수;조문재;서상준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.448-452
    • /
    • 2002
  • We report the number of calibration and test for acoustic field which were conducted in KRISS between the year of 1990 and 2001. The items contain sound level meter and calibrator for calibration and sound absorption coefficient, transmission loss, sound pressure level of siren, sound pressure level and power of acoustic instrument and relative accessories for test. The data show that the number of them have been increased continuously.

  • PDF

다점식 피토관의 효율적인 교정에 대한 연구 (Investigation on the Effective Calibration of Annubar)

  • 최용문;최해만;최지철;홍경기;한상우;김웅선;전세종
    • 대한기계학회논문집B
    • /
    • 제30권4호
    • /
    • pp.373-380
    • /
    • 2006
  • Annubar is one of popular tools to measure the exhausted gas flow rate from the stacks. For the accurate monitoring of the amount of discharged pollutants, calibration of annubar is very important. Calibration of annubar has been carried out in a wind tunnel. When the length of annubar is longer than the test section size of wind tunnel, it is very difficult to find out typical value of annubar coefficients. So, a measurement technique to calibrate annubar longer than the size of the test section of wind tunnel must be developed. In the present study, an experiment is performed to measure the annubar coefficients in such a limited size of the wind tunnel. The experimental annubar coefficient by using a partial blocking technique is very close to the annubar coefficient of normal condition.

Absolute Radiometric Calibration을 위한 Field Campaign과 시험결과 (Field Campaigns and test results for Absolute Radiometric Calibration)

  • 이선구;김용승
    • 항공우주기술
    • /
    • 제5권2호
    • /
    • pp.213-219
    • /
    • 2006
  • 한국항공우주연구원에서는 2006년 발사될 다목적실용위성 2호의 절대복사보정(absolute radiometric calibration)을 위한 준비로, Orbview-3 위성의 통과시간에 맞추어 2004년 11월 4일 과 2005년 3월 7일에 고흥과 대전에서 Field campaign을 수행하였다. 절대복사보정은 vicarious calibration 방법 중 targets의 반사 특성을 이용하는 방법으로, Field campaign을통해 수집된 지표자료와 대기자료들을 이용하여 top-of-radiance(TOA)를 추출하였다 대기 복사모델로는 MODTRAN 4.0이 사용되었으며, 추출된 TOA radiance와 Orbview-3 Panchromatic DN과 비교를 하여 절대복사보정을 위한 offset과 gain계수를 계산하였다. 또한 본 연구에서는 Field Campaign으로부터 축적된 경험을 이용하여 다목적실용위성 2호의 절대복사보정에 적용할 방법을 제안하였다.

  • PDF

증발산 장기 관측에 따른 크립톤 습도계의 흡수 계수의 변화와 이슬점 생성기를 이용한 기기 보정 (Changes in Absorption Coefficient of Krypton Hygrometer in Long-term Monitoring of Evapotranspiration and Its Calibration Using a Dew Point Generator)

  • 박윤호;김준;이희춘;임종환;권원태
    • 한국농림기상학회지
    • /
    • 제2권3호
    • /
    • pp.75-79
    • /
    • 2000
  • Calibrations of fast-response krypton hygrometers were carried out using a dew-point hygrometer to investigate the changes in their absorption coefficients due to long-term field operation. Absorption coefficients changed proportionally with the number of hours of field operation. The increase in absorption coefficient indicates that the water vapor flux, calculated with the original absorption coefficient, would underestimate the true flux in the field. To minimize the uncertainty in quantifying evapotranspiration and surface energy budget studies, frequent calibrations (for example, every 1500 hours of field operation) of krypton hygrometer are recommended.

  • PDF

Measurement of lipid content of compost fermentation using near-infrared spectroscopy

  • Daisuke Masui;Suehara, Ken-ichiro;Yasuhisa Nakano;Takuo Yano
    • Near Infrared Analysis
    • /
    • 제2권1호
    • /
    • pp.37-42
    • /
    • 2001
  • Near infrared spectroscopy (NIRS) was applied to determination of the lipid content of the compost during the compost fermentation of tofu (soybean0curd) refuse. The absorption of lipid observed at 5 wavelengths, 1208, 1712, 1772, 2312 and 2352 nm on the second derivative spectra. To formulated a calibration equation, a multiple linear regression analysis was carried out between the near-infrared spectral data and on the lipid content in the calibration sample set (sample number, n=60) obtained using Soxhlet extraction method. The value of the multiple correlation coefficient (R) was 0.975 when using the wavelengths of 1208 and 1712 nm were used in the calibration equation. To validate the calibration equation obtained, the lipid content in the validation sample set (n=35) not used for formulating the calibration equation was calculated using the calibration equation, and compared with the value obtained using the Soxhlet extraction method. Good agreement was observed between the results of the Soxhlet extraction method and those values of the NIRS method. The simple correlation coefficient (r) and standard error of prediction (SEP) were 0.964 and 0.815 %, respectively. suitability of the lipid content as an indicator of the compost fermentation of tofu refuse was also studied. The decrease of the lipid content in the compost corresponded to the decrease of the total dry weight of the compost in the composter. The lipid content was a significant indicator of the compost fermentation. The NIRS method was applied to measure the time course of the lipid content in the compost fermentation and good results were obtained. The study indicates that NIRS is a useful method for process management of the compost fermentation of tofu refuse.

Measurement of Lipid Content of Compost in the fermentation Process using Near-Infrared Spectroscopy

  • Suehara, Ken-Ichiro;Masui, Daisuke;Nakano, Yasuhisa;Yano, Takuo
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1254-1254
    • /
    • 2001
  • Near infrared spectroscopy (NIRS) was applied to determination of the lipid content of compost during compost fermentation of tofu(soybean-curd) refuse. The reflected rays in the wavelength range between 800 and 2500 nm were measured at 2 nm intervals. The absorption of lipid observed at 4 wavelengths, 1208, 1712, 2312 and 2352 nm on the second derivative spectra. To formulate a calibration equation, a multiple linear regression analysis was carried out between the near-infrared spectral data and on the lipid content in the calibration sample set (sample number, n=60) obtained using a Soxhlet extraction method. The calibration equation for prediction of lipid, the value of the multiple correlation coefficient (R) was 0.975 when using the wavelengths of 1208 and 1712nm. To validate the calibration equation obtained, the lipid content in the validation sample set (n=35) not used for formulating the calibration equation were calculated using the calibration equations, and compared with the values obtained using the Soxhlet extraction method. Good agreement were observed between the results of the Soxhlet extraction method and those values of the NIRS method. The simple correlation coefficient (r) and standard error of prediction (SEP) were 0.964 and 0.815 %, respectively. Then, the NIRS method was applied to a compost fermentation in which the time course the lipid content were measured and good results were obtained. The study indicates that NIRS is a useful method for process management of the compost fermentation of tofu refuse.

  • PDF

삼직교 열선유속계의 간편한 측정법 개발 (Development of Easy Measurement Method of Orthogonal Triple-Sensor Hot-Wire Anemometer)

  • 김진권;강신형
    • 대한기계학회논문집B
    • /
    • 제24권1호
    • /
    • pp.85-92
    • /
    • 2000
  • Easy measurement method of orthogonal triple-sensor hot-wire anemometer is developed. Advantages of the new method is that it does not require either the exact orthogonality of the installed wires which cannot be kept during the probe manufacture and repair, nor the knowledge of the wire installation angles and the yaw and pitch coefficient of the wires. The new method introduced yaw and pitch calibration coefficients which are designed to increase monotonically with yaw and pitch angles. So the resulting calibration network is simple to recognize compared with that of the previously suggested calibration method. Verification experiments showed good accuracy and independency of the directional calibration on velocity.

ABSOLUTE RADIOMETRIC CALIBRATION OF 1M SATELLITE IMAGERY

  • Lee Sun-Gu;Lee Dong-han;Seo Doo-chun;Song Jeong Heon;Kim Yongseung;Paik Hongyul
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.616-619
    • /
    • 2005
  • CALNAL team of Korea Aerospace Research Institute(KARI) performed field campaigns for absolute radiometric calibration of 1m satellite image on Daejeon and the cal/val site of Goheung. The satellite image have spatial resolution of 1m in panchromatic spectral band of 450-900nm. The performed cal/val method is the reflectance-based of vicarious calibration methods. We collected ground-based and meteology data such as temperature, surface pressure and reflectance of targets, and radiosonde data used only to test in Goheung. Data collected on each field served as input to radiative transfer codes to generate a top-of-atmosphere(TOA) radiance estimate. Derived TOA is compared with DN of overpass satellite to calculate calibration coefficient of gain and offset.

  • PDF