• 제목/요약/키워드: calibration center

검색결과 760건 처리시간 0.032초

CALIBRATION ISSUES OF SPACEBORNE MICROWAVE RADIOMETER DREAM ON STSAT-2

  • Singh, Manoj Kumar;Kim, Sung-Hyun;Chae, Chun-Sik;Lee, Ho-Jin;Park, Jong-Oh;Sim, Eun-Sup;Zhang, De-Hai;Jiang, Jing-Shan;Kim, Yong-Hoon
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.398-401
    • /
    • 2006
  • Dual channel Radiometer for Earth and Atmospheric Monitoring (DREAM) is the main payload on Science and Technology SATellite-2 (STSAT-2) of Korea. DREAM is two-channel microwave radiometer with linear polarization, and operating at center frequencies of 23.8 GHz and 37 GHz. An equation for DREAM calibration is derived which accounts for losses and re-radiation in the microwave components of the radiometer due to physical temperature. This paper describes the radiometric calibration equation to get antenna temperature ($T_A$) from the measured output data. At lower altitude, the measured deep space temperature is contaminated by middle atmosphere and earth radiation. In this paper, we presented the detail mathematical formulation to find the altitude up to which cold source brightness temperature is not affected by earth and middle atmosphere radiation. The DREAMPFM data is used to calculate the performance parameters (linearity, sensitivity, dynamic range, and etc.) of the system.

  • PDF

질소의 끓는점에서의 산업용 온도계 비교 교정과 불확도 평가 (Calibration by Comparison and Uncertainty Assessment of Industrial Thermometers at the Boiling Point of Nitrogen)

  • 양인석;감기술;정욱철;김용규
    • 센서학회지
    • /
    • 제22권6호
    • /
    • pp.404-409
    • /
    • 2013
  • We devised calibration procedure for industrial thermometers by a comparison method at the boiling point of nitrogen (${\sim}-196^{\circ}C$). The uncertainty of the calibration was 4 mK (k = 2). As experimentally demonstrated in this work, the effect of the atmospheric pressure on the boiling point of nitrogen can be easily detected by the thermometer. Therefore, when the boiling point of nitrogen is used for calibration of thermometer by comparison, either a reference thermometer must be used to provide the reference temperature or the effect of atmospheric pressure should be carefully considered. The use of a copper block with a large thermal mass soaked into the liquid nitrogen was proven to be more reliable, and the stability of the temperature immersed into the copper block was 1.4 mK. The temperatures at the thermometer wells, evaluated by the crossed-measurement method to compensate for the inaccuracy of the thermometers and the linear drift of the temperature of the copper block, were equivalent within 0.23 mK of standard uncertainty.

Evaluation of GSICS Correction for COMS/MI Visible Channel Using S-NPP/VIIRS

  • Jin, Donghyun;Lee, Soobong;Lee, Seonyoung;Jung, Daeseong;Sim, Suyoung;Huh, Morang;Han, Kyung-soo
    • 대한원격탐사학회지
    • /
    • 제37권1호
    • /
    • pp.169-176
    • /
    • 2021
  • The Global Space-based Inter-Calibration System (GSICS) is an international partnership sponsored by World Meteorological Organization (WMO) to continue and improve climate monitoring and to ensure consistent accuracy between observation data from meteorological satellites operating around the world. The objective for GSICS is to inter-calibration from pairs of satellites observations, which includes direct comparison of collocated Geostationary Earth Orbit (GEO)-Low Earth Orbit (LEO) observations. One of the GSICS inter-calibration methods, the Ray-matching technique, is a surrogate approach that uses matched, co-angled and co-located pixels to transfer the calibration from a well calibrated satellite sensor to another sensor. In Korea, the first GEO satellite, Communication Ocean and Meteorological Satellite (COMS), is used to participate in the GSICS program. The National Meteorological Satellite Center (NMSC), which operated COMS/MI, calculated the Radiative Transfer Model (RTM)-based GSICS coefficient coefficients. The L1P reproduced through GSICS correction coefficient showed lower RMSE and Bias than L1B without GSICS correction coefficient applied. The calculation cycles of the GSICS correction coefficients for COMS/MI visible channel are provided annual and diurnal (2, 5, 10, 14-day), but long-term evaluation according to these cycles was not performed. The purpose of this paper is to perform evaluation depending on the annual/diurnal cycles of COMS/MI GSICS correction coefficients based on the ray-matching technique using Suomi-NPP/Visible Infrared Imaging Radiometer Suite (VIIRS) data as reference data. As a result of evaluation, the diurnal cycle had a higher coincidence rate with the reference data than the annual cycle, and the 14-day diurnal cycle was the most suitable for use as the GSICS correction coefficient.

냉·난방도일에 따른 건물에너지 사용량 보정기법 개발 (The Development of the Calibration Method of Building Energy Consumption by HDDm and CDDm)

  • 김동일;이병호
    • 한국태양에너지학회 논문집
    • /
    • 제38권6호
    • /
    • pp.15-26
    • /
    • 2018
  • It is difficult to check the exact building energy consumption reduction such as when green remodeling of buildings, because it is due to outdoor air temperature over the years. And in Korea although Big Data of building energy consumption is collected and managed through "The Information System of the Building Energy and Greenhouse Gases" it is underutilized because of non calibration of outdoor air temperature change. Therefore, this study aims to develope calibration method of building energy consumption by outdoor air temperature according to micro climates, and building use types. As a result of analysis, Regression equations of Building energy consumption and $HDD_m/CDD_m$ are derived and calibration method is developed by Regression coefficient.

Laboratory geometric calibration simulation analysis of push-broom satellite imaging sensor

  • Reza Sh., Hafshejani;Javad, Haghshenas
    • Advances in aircraft and spacecraft science
    • /
    • 제10권1호
    • /
    • pp.67-82
    • /
    • 2023
  • Linear array imaging sensors are widely used in remote sensing satellites. The final products of an imaging sensor can only be used when they are geometrically, radiometrically, and spectrally calibrated. Therefore, at the first stages of sensor design, a detailed calibration procedure must be carefully planned based on the accuracy requirements. In this paper, focusing on inherent optical distortion, a step-by-step procedure for laboratory geometric calibration of a typical push-broom satellite imaging sensor is simulated. The basis of this work is the simulation of a laboratory procedure in which a linear imager mounted on a rotary table captures images of a pin-hole pattern at different angles. By these images and their corresponding pinhole approximation, the correction function is extracted and applied to the raw images to give the corrected ones. The simulation results illustrate that using this approach, the nonlinear effects of distortion can be minimized and therefore the accuracy of the geometric position of this method on the image screen can be improved to better than the order of sub-pixel. On the other hand, the analyses can be used to proper laboratory facility selection based on the imaging sensor specifications and the accuracy.

단일 바퀴 구동 캐스터 기반 모바일 로봇의 캘리브레이션 (Calibration of Mobile Robot with Single Wheel Powered Caster)

  • 김형철;박수한;박재흥
    • 로봇학회논문지
    • /
    • 제17권2호
    • /
    • pp.183-190
    • /
    • 2022
  • Accurate kinematic parameters of mobile robots are essential because inaccurate kinematic model produces considerable uncertainties on its odometry and control. Especially, kinematic parameters of caster type mobile robots are important due to their complex kinematic model. Despite the importance of accurate kinematic parameters for caster type mobile robots, few research dealt with the calibration of the kinematic model. Previous study proposed a calibration method that can only calibrate double-wheeled caster type mobile robot and requires direct-measuring of robot center point and distance between casters. This paper proposes a calibration method based on geometric approach that can calibrate single-wheeled caster type mobile robot with two or more casters, does not require direct-measuring, and can successfully acquire all kinematic parameters required for control and odometry. Simulation and hardware experiments conducted in this paper validates the proposed calibration method and shows its performance.

Tools for Echelle Spectrograph of NYSC 1m Telescope

  • Kang, Wonseok;Kim, Taewoo;Kim, Jeongeun;Shin, Yong Cheol;Yoo, Jihyun;Jeong, Shinu;Choi, Yoonho;Kwon, Sun-gill
    • 천문학회보
    • /
    • 제43권1호
    • /
    • pp.50.1-50.1
    • /
    • 2018
  • We present the development of tools for Echelle spectrograph of NYSC 1-m telescope. The eShel spectrograph(Shelyak) has operated at Deokheung Optical Astronomy Observatory since 2016. We carried out test observation in 2016 and completed the preprocessing and wavelength calibration of the spectroscopic data using IRAF. Based on the reduction process in IRAF, PySpecW, a set of tools for spectroscopic data was developed in 2017. PySpecW was optimized for NYSC 1m telescope, and written in Python for youth to use easily on any OS. PySpecW consists of preprocessing, aperture tracing, aperture extraction, wavelength calibration, and dispersion correction for extracted spectra.

  • PDF

채점자 조정(calibration) 교육 제안을 위한 평가자 신뢰도 분석 (Analysis of Evaluator Reliability for the Raters' Calibration Training)

  • 김주아;신유석;서정택
    • 대한치과의사협회지
    • /
    • 제58권5호
    • /
    • pp.284-291
    • /
    • 2020
  • This study analyzed the change in the rater reliability based on the student's practice evaluation process conducted at Yonsei University College of Dentistry. Through this, we suggest the significance of the rater calibration training in the student's practical evaluation of dental college. Nine professors from the department of Conservative Dentistry, Yonsei University College of Dentistry, analyzed the results of class II restoration cases twice in 2017 and once in 2018. Intra Class Correlation (ICC) which is a statistic used to determine the consistency of raters with three or more scores, was also calculated. ICC values increased as raters participated in rater calibration meetings and grading experiences. This shows that the rater reliability is related to the grading experience and feedback from calibration meeting. Based on the results of previous studies that grading experiences and rater calibration training can cause a meaningful change in rater behavior, we propose to conduct rater calibration training to ensure the evaluator reliability.

  • PDF

점성토에 있어서 지반의 비등방성을 고려한 콘 관입속도에 관한 연구 (Study on Cone Penetration Rate and Anisotropy in Cohesive Soils)

  • Kim, Dae-Kyu;Lee, Woo-Jin
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.559-566
    • /
    • 2000
  • 본 연구에서는 비등방성 응력조건 하에서 콘 관입속도가 콘 관입시험 결과에 미치는 영향을 연구하기 위하여 유한요소해석 및 Calibration Chamber를 이용한 Miniature Piezocone의 관입시험이 수행되었으며 그 결과를 비교 분석하였다. 비등방성을 고려하기 위하여 Anisotropic Soil Model이 유한요소해석에 이용되었으며 LSU/CALCHAS(Louisiana State University Calibration Chamber System)가 Miniature Piezocone의 관입시험에 이용되었다. 콘 관입속도의 영향이외에도 OCR 및 필터위치의 영향을 고찰하였다.

  • PDF