• 제목/요약/키워드: calibration bias

검색결과 146건 처리시간 0.029초

THE CALIBRATED VARIANCE ESTIMATOR UNDER THE UNIT NONRESPONSE

  • Son, Chang-Kyoon;Hong, Ki-Hak;Lee, Gi-Sung
    • Journal of applied mathematics & informatics
    • /
    • 제8권3호
    • /
    • pp.975-987
    • /
    • 2001
  • We treat the problem of variance estimation for the estimator of population total, which is derived from the calibration estimation procedure corresponding to the levels of auxiliary information under nonresponse situation. We develop the calibrated variance estimation procedure using the fact that the population total and variance as well as the sample total and variance of the auxiliary variable are known. We show that the proposed variance estimation procedure improves the $Lundst\ddot{o}rm$ and $S\ddot{a}rndal's$ (1999) procedure with respect to the variance and nonresponse bias reduction through the simulation study.

IMPLEMENTATION OF DATA ASSIMILATION METHODOLOGY FOR PHYSICAL MODEL UNCERTAINTY EVALUATION USING POST-CHF EXPERIMENTAL DATA

  • Heo, Jaeseok;Lee, Seung-Wook;Kim, Kyung Doo
    • Nuclear Engineering and Technology
    • /
    • 제46권5호
    • /
    • pp.619-632
    • /
    • 2014
  • The Best Estimate Plus Uncertainty (BEPU) method has been widely used to evaluate the uncertainty of a best-estimate thermal hydraulic system code against a figure of merit. This uncertainty is typically evaluated based on the physical model's uncertainties determined by expert judgment. This paper introduces the application of data assimilation methodology to determine the uncertainty bands of the physical models, e.g., the mean value and standard deviation of the parameters, based upon the statistical approach rather than expert judgment. Data assimilation suggests a mathematical methodology for the best estimate bias and the uncertainties of the physical models which optimize the system response following the calibration of model parameters and responses. The mathematical approaches include deterministic and probabilistic methods of data assimilation to solve both linear and nonlinear problems with the a posteriori distribution of parameters derived based on Bayes' theorem. The inverse problem was solved analytically to obtain the mean value and standard deviation of the parameters assuming Gaussian distributions for the parameters and responses, and a sampling method was utilized to illustrate the non-Gaussian a posteriori distributions of parameters. SPACE is used to demonstrate the data assimilation method by determining the bias and the uncertainty bands of the physical models employing Bennett's heated tube test data and Becker's post critical heat flux experimental data. Based on the results of the data assimilation process, the major sources of the modeling uncertainties were identified for further model development.

자가보정 바이어스 기법을 이용한 Current Steering 10-bit CMOS D/A 변환기 설계 (Design of a Current Steering 10-bit CMOS D/A Converter Based on a Self-Calibration Bias Technique)

  • 임채열;이장우;송민규
    • 전자공학회논문지
    • /
    • 제50권10호
    • /
    • pp.91-97
    • /
    • 2013
  • 본 논문에서는 NTSC/PAL 아날로그 TV를 구동하기 위한 10-bit current steering D/A 변환기를 제안하였다. 제안하는 D/A 변환기는 50MS/s 의 동작속도를 가지며, 6+4 분할 구조로 설계되었다. 또한 새로운 개념의 자가보정 바이어스 기법을 적용하여 칩 내부의 종단저항을 사용하고도 공정오차를 최소화 하였다. 제안하는 D/A 변환기는 3.3V 0.11um 1-poly 6-metal CMOS 공정을 사용하여 제작되었다. 제작된 칩의 유효 면적은 $0.35mm^2$, 3.3V 전원전압 상에서 약 88mW의 전력소모를 나타내었다. 실험 결과는 변환 속도 50MS/s, 입력 주파수 1MHz에서 SFDR 63.1dB의 특성을 나타내었다.

An Intercomparison of Counting Efficiency and the Performance of Two Whole-Body Counters According to the Type of Phantom

  • Pak, Minjung;Yoo, Jaeryong;Ha, Wi-Ho;Jin, Young-Woo
    • Journal of Radiation Protection and Research
    • /
    • 제41권3호
    • /
    • pp.274-281
    • /
    • 2016
  • Background: Whole-body counters are widely used to evaluate internal contamination of the internal presence of gamma-emitting radionuclides. In internal dosimetry, it is a basic requirement that quality control procedures be applied to verify the reliability of the measured results. The implementation of intercomparison programs plays an important role in quality control, and the accuracy of the calibration and the reliability of the results should be verified through intercomparison. In this study, we evaluated the reliability of 2 whole-body counting systems using 2 calibration methods. Materials and Methods: In this study, 2 whole-body counters were calibrated using a reference male bottle manikin absorption (BOMAB) phantom and a Radiation Management Corporation (RMC-II) phantom. The reliability of the whole-body counting systems was evaluated by performing an intercomparison with International Atomic Energy Agencyto assess counting efficiency according to the type of the phantom. Results and Discussion: In the analysis of counting efficiency using the BOMAB phantom, the performance criteria of the counters were satisfied. The relative bias of activity for all radionuclides was -0.16 to 0.01 in the Fastscan and -0.01 to 0.03 in the Accuscan. However, when counting efficiency was analyzed using the RMC- II phantom, the relative bias of $^{241}Am$ activity was -0.49 in the Fastscan and 0.55 in the Accuscan, indicating that its performance criteria was not satisfactory. Conclusion: The intercomparison process demonstrated the reliability of whole-body counting systems calibrated with a BOMAB phantom. However, when the RMC-II phantom was used, the accuracy of measurements decreased for low-energy nuclides. Therefore, it appears that the RMC-II phantom should only be used for efficiency calibration for high-energy nuclides. Moreover, a novel phantom capable of matching the efficiency of the BOMAB phantom in low-energy nuclides should be developed.

Statistical bias indicators for the long-term displacement of steel-concrete composite beams

  • Moreno, Julian A.;Tamayo, Jorge L.P.;Morsch, Inacio B.;Miranda, Marcela P.;Reginato, Lucas H.
    • Computers and Concrete
    • /
    • 제24권4호
    • /
    • pp.379-397
    • /
    • 2019
  • Steel-concrete composite beams are widely employed in constructions and their performance at the serviceability stage is of concern among practitioners and design regulations. In this context, an accurate evaluation of long-term deflections via various rheological concrete models is needed. In this work, the performance and predict capability of some concrete creep and shrinkage models ACI, CEB, B3, FIB and GL2000 are ascertained, and compared by using statistical bias indicators. Ten steel-concrete composite beams with existing experimental and numerical results are then modeled for this purpose. The proposed modeling technique uses the finite element method, where the concrete slab and steel beam are modeled with shell finite elements. Concrete is considered as an aging viscoelastic material and cracking is treated with the common smeared approach. The results show that when the experimental ultimate shrinkage strain is used for calibration, all studied rheological models predict nearly similar deflections, which agree with the experimental data. In contrast, significance differences are encountered for some models, when none calibration is made prior to. A value between twenty and thirty times the cracking strain is recommended for the ultimate tensile strain in the tension stiffening model. Also, increasing the relative humidity and decreasing the ambient temperature can lead to a substantial reduction of slab cracking for beams under negative flexure. Finally, there is not a unique rheological model that clearly excels in all scenarios.

STANDARDISATION OF NIR INSTRUMENTS, INFLUENCE OF THE CALIBRATION METHODS AND THE SIZE OF THE CLONING SET

  • Dardenne, Pierre;Cowe, Ian-A.;Berzaghi, Paolo;Flinn, Peter-C.;Lagerholm, Martin;Shenk, John-S.;Westerhaus, Mark-O.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1121-1121
    • /
    • 2001
  • A previous study (Berzaghi et al., 2001) evaluated the performance of 3 calibration methods, modified partial least squares (MPLS), local PLS (LOCAL) and artificial neural networks (ANN) on the prediction of the chemical composition of forages, using a large NIR database. The study used forage samples (n=25,977) from Australia, Europe (Belgium, Germany, Italy and Sweden) and North America (Canada and U.S.A) with reference values for moisture, crude protein and neutral detergent fibre content. The spectra of the samples were collected using 10 different Foss NIR Systems instruments, only some of which had been standardized to one master instrument. The aim of the present study was to evaluate the behaviour of these different calibration methods when predicting the same samples measured on different instruments. Twenty-two sealed samples of different kind of forages were measured in duplicate on seven instruments (one master and six slaves). Three sets of near infrared spectra (1100 to 2500nm) were created. The first set consisted of the spectra in their original form (unstandardized); the second set was created using a single sample standardization (Clone1); the third was created using a multiple sample procedure (Clone6). WinISI software (Infrasoft International Inc., Port Mathilda, PA, USA) was used to perform both types of standardization, Clone1 is just a photometric offset between a “master” instrument and the “slave” instrument. Clone6 modifies both the X-axis through a wavelength adjustment and the Y-axis through a simple regression wavelength by wavelength. The Clone1 procedure used one sample spectrally close to the centre of the population. The six samples used in Clone 6 were selected to cover the range of spectral variation in the sample set. The remaining fifteen samples were used to evaluate the performances of the different models. The predicted values for dry matter, protein and neutral detergent fibre from the master Instrument were considered as “reference Y values” when computing the statistics RMSEP, SEPC, R, Bias, Slope, mean GH (global Mahalanobis distance) and mean NH (neighbourhood Mahalanobis distance) for the 6 slave instruments. From the results we conclude that i) all the calibration techniques gave satisfactory results after standardization. Without standardization the predicted data from the slaves would have required slope and bias correction to produce acceptable statistics. ii) Standardization reduced the errors for all calibration methods and parameters tested, reducing not only systematic biases but also random errors. iii) Standardization removed slope effects that were significantly different from 1.0 in most of the cases. iv) Clone1 and Clone6 gave similar results except for NDF where Clone6 gave better RMSEP values than Clone1. v) GH and NH were reduced by half even with very large data sets including unstandardized spectra.

  • PDF

근적외분광분석법과 Micro-Kjeldahl 법 간의 맥주보리 종실의 단백질함량 분석 비교 (Comparisons between Micro-Kjeldahl and Near Infrared Reflectance Spectroscopy for Protein Content Analysis of Malting Barley Grain)

  • 김병주;서득용;서형수
    • 한국작물학회지
    • /
    • 제39권5호
    • /
    • pp.489-494
    • /
    • 1994
  • 맥주보리 품질에서 중요한 성분인 단백질함량을 NIRS를 이용하여 신원하고 정확하게 분석하기 위해 최적의 검양식 작성에 관한 일련의 시험을 실시한 결과는 다음과 같다. 1. Micro-Kjeldahl법에 의해 분석한 단백질함량을 이용하여 작성된 NIRS의 검양식중 2095 /1941/ 2282/ 2086nm 파장으로 구성된 검양식에서 결정계수($R^2$)가 0.95로서 가장 높았다. 2. NIRS의 2095/1941/2282/2086nm 파장으로 구성된 검양식으로 '92년도에 생산된 18품종을 분석한 결과 SDD가 0.47, SEP가 0.43, r이 0.95로서 매우 우수하였으며 평균 단백질함량도 Micro-Kjeldahl법의 10.25%와 동일하였다. 3. NIRS의 2095/1941/2282/2086nm 파장으로 구성된 검양식으로 '93년에 생산된 미지의 시료 31품종을 Micro-Kjeldahl법과 비교분석한 결과 SDD가 0.69, SEP가 0.67, r(simple correlation)이 0.91이었다. 4. 본 시험에서 작성된 NIRS의 검양식을 이용할 경우 Micro-Kjeldahl 분석치와 r값이 0.91로서 고도의 유의성이 인정되었으며 bias값을 보정해 주면 단백질함량의 평균값이 Micro-Kjeldahl법과 매우 근접된 값을 얻을 수 있어서 맥주보리 육종의 초기세대에서 단기간 다량의 계통을 분석할 수 있을 것으로 기대되었다.

  • PDF

Calibration transfer between miniature NIR spectrometers used in the assessment of intact peach and melon soluble solids content

  • Greensill, Colin.V.;Walsh, Kerry.B.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1127-1127
    • /
    • 2001
  • The transfer of predictive models using various chemometric techniques has been reported for FTNIR and scanning-grating based NIR instruments with respect relatively dry samples (<10% water). Some of the currently used transfer techniques include slope and bias correction (SBC), direct standardization (DS), piecewise direct standardization (PDS), orthogonal signal correction (OSC), finite impulse transform (FIR) and wavelet transform (WT) and application of neural networks. In a previous study (Greensill et at., 2001) on calibration transfer for wet samples (intact melons) across silicon diode array instrumentation, we reported on the performance of various techniques (SBC, DS, PDS, double window PDS (DWPDS), OSC, FIR, WT, a simple photometric response correction and wavelength interpolative method and a model updating method) in terms of RMSEP and Fearns criterion for comparison of RMSEP. In the current study, we compare these melon transfer results to a similar study employing pairs of spectrometers for non-invasive prediction of soluble solid content of peaches.

  • PDF

BVRI Filter Standardization of DOAO 1m Telescope

  • Ahn, Hojae;Pak, Soojong;Kang, Wonseok;Kim, Taewoo
    • 천문학회보
    • /
    • 제42권1호
    • /
    • pp.58.1-58.1
    • /
    • 2017
  • National Youth Space Center has recently founded the Deokheung Optical Astronomy Observatory (DOAO) 1m Telescope, which accepts community observing applications since 2016. Standardization and calibration of the new observing facility are essential for astronomical research. In this poster, we present standardization processes and preliminary results for photometry of the Johnson-Cousins BVRI filter system. We selected sample data from a night in stable weather condition. After bias, dark, and flat corrections and photometry using ccdred and daophot package of IRAF, we derived standardized band pass parameters including color terms. The corrected photometry results of the BVRI filter system show reduced deviations from the standard magnitudes in the literature. In addition, we calculated atmospheric extinction coefficients and limiting magnitudes of the telescope system. We plan to extend these standardizing processes to flux calibration of narrow band filters, e.g. $H{\alpha}$ filter.

  • PDF

A Compensator to Advance Gyro-Free INS Precision

  • Hung Chao-Yu;Fang Chun-Min;Lee Sou-Chen
    • International Journal of Control, Automation, and Systems
    • /
    • 제4권3호
    • /
    • pp.351-358
    • /
    • 2006
  • The proposed inertial measurement unit (IMU) is composed of accelerometers only. It can determine a vehicle's position and attitude, which is the Gyro-free INS. The Gyro-free INS error is deeply affected by the sensor bias, scale factor and misalignment. However, these parameters can be obtained in the laboratory. After these misalignments are corrected, the Gyro-free strap-down INS could be more accurate. This paper presents a compensator design for the strap-down six-accelerometer INS to correct misalignment. A calibration experiment is taken to get the error parameters. A simulation results show that it will decrease the INS error to enhance the performance after compensation.