• Title/Summary/Keyword: calculation method

Search Result 7,840, Processing Time 0.037 seconds

Verification of neutronics and thermal-hydraulic coupled system with pin-by-pin calculation for PWR core

  • Zhigang Li;Junjie Pan;Bangyang Xia;Shenglong Qiang;Wei Lu;Qing Li
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3213-3228
    • /
    • 2023
  • As an important part of the digital reactor, the pin-by-pin wise fine coupling calculation is a research hotspot in the field of nuclear engineering in recent years. It provides more precise and realistic simulation results for reactor design, operation and safety evaluation. CORCA-K a nodal code is redeveloped as a robust pin-by-pin wise neutronics and thermal-hydraulic coupled calculation code for pressurized water reactor (PWR) core. The nodal green's function method (NGFM) is used to solve the three-dimensional space-time neutron dynamics equation, and the single-phase single channel model and one-dimensional heat conduction model are used to solve the fluid field and fuel temperature field. The mesh scale of reactor core simulation is raised from the nodal-wise to the pin-wise. It is verified by two benchmarks: NEACRP 3D PWR and PWR MOX/UO2. The results show that: 1) the pin-by-pin wise coupling calculation system has good accuracy and can accurately simulate the key parameters in steady-state and transient coupling conditions, which is in good agreement with the reference results; 2) Compared with the nodal-wise coupling calculation, the pin-by-pin wise coupling calculation improves the fuel peak temperature, the range of power distribution is expanded, and the lower limit is reduced more.

Methods in Palaeomagnetism (II): Calculation and Plotting of Palaeomagnetic Pole Positions (고자기학(古磁氣學)의 방법(方法)(II) : 고자기학적(古磁氣學的) 측정자료로부터 자북(磁北)의 위치를 도시하는 방법)

  • Kim, In-Soo
    • Economic and Environmental Geology
    • /
    • v.22 no.2
    • /
    • pp.167-171
    • /
    • 1989
  • Palaeomagnetic studies accompany calculation and plotting of pole position. This paper explains three graphical methods for the determination of pole position and plotting problem. It also derives the numerical formula for pole calculation and explains the method how the pole plotted on the rear hemisphere can be transformed to the frontal hemisphere, which is not clarified elsewhere.

  • PDF

Monte-Carlo Calculation of Single-Electron Inverter Transient Characteristics (몬테-칼로 방법을 이용한 단일전자인버터 회로의 과도특성 계산)

  • 정용익;유윤섭;황성우
    • Proceedings of the IEEK Conference
    • /
    • 2000.06b
    • /
    • pp.326-329
    • /
    • 2000
  • In this paper, a complete methodology of incorporating the displacement current for the calculation of a single electron inverter characteristics has been devised. It has been implemented for the calculation of the low frequency noise spectrum in a single electron inverter in the framework of Monte-Carlo method. Our new methodology opens up a systematic way of analyzing transient behaviors of single electron circuits.

  • PDF

Sample size estimation using nomogram in dental research (치의학 연구에서 노모그램을 이용한 표본수 계산)

  • Kim, Ki-Yeol
    • The Journal of the Korean dental association
    • /
    • v.54 no.8
    • /
    • pp.630-638
    • /
    • 2016
  • The appropriate sample size calculation in dental research is important to achieve the study purpose at the first step in study design. However, it cannot be easy to calculate sample size using standard formulas, because the several factors must be considered for calculation. This study introduced the graphic method for sample size calculation, which is called nomogram. The purpose of this study is to show the effectiveness of the nomogram using examples, expecting the researchers can easily use nomogram for sample size determination.

  • PDF

Calculation of AC Losses by Perpendicular Magnetic Field (수직방향 자장에 의한 교류손실 계산)

  • 이승욱;심정욱;차귀수;이지광
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.172-175
    • /
    • 2001
  • AC loss which is generated in an HTS wire varies with the direction of the external magnetic field. This paper calculates the AC loss in an HTS tape, where effects of the perpendicular direction of the magnetic field are considered. Brandt equation is used to calculate the loss by perpendicular magnetic field. In the calculation, current densities are varied along the variation of the magnitude of the external magnetic field. Results of calculation are compared with those of the conventional method.

  • PDF

Study on Area Calculation in Warehouse (보관시설 내 공간 산정에 관한 연구)

  • Kim, Young-Joo;Lee, Suk;Kim, Kyoung-Tae
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1567-1573
    • /
    • 2010
  • The purpose of this study is to develop spatial configuration and area calculation method of warehoue. This paper deals with warehouses with palletized cargo since recently pallets are widely used in many warehouses to enhance efficiency. We identify spatial configuration and characteristics of each area. To represent realistic situations, we analyze characteristics of logistics equipment as well as interview results with expert warehouse architects. Through these analysis we suggest guidelines on area calculation of warehouse.

  • PDF

Energy band structure calculation of crystalline solids using meshfree methods (무요소법을 이8한 결정고체의 에너지 띠 구조 계산)

  • 전석기;임세영
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.623-628
    • /
    • 2002
  • A meshfree formulation for the calculation of energy band structure is presented. The conventional meshfree shape function is modified to handle the periodicity of Bravais lattice, and applied to the calculation of real-space electronic-band structure. Numerical examples include the Kronig-Penney model potential and the empirical pseudopotentials of diamond and zinc-blonde semiconductors. Results demonstrate that the meshfree method be a promising one as a real-space technique for the calculations of diverse physical band structures.

  • PDF

Back calculation and solution Technique of E-modulus by FWD′s deflection data in Pavement (FWD 처짐치에 의한 포장층 탄성계수 역산 및 해석기법)

  • 위성동
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.188-200
    • /
    • 2002
  • In this study, a pavement evaluation method is introduced by a case study of the measurement data obtained in Incheon International Airport. Based on the results obtained by both visual inspection and automobile inspection equipments, the pavement surface condition is evaluated and used for maintenance and rehabilitation strategy for pavement. In addition, the special attention was given to the back calculation and solution technique of E-modulus by FWD's deflection data in Pavement.

  • PDF

The Optimum Calculation of Motor Load by Motor Driving Factor Application (운전율 적용에 의한 동력부하의 적정산정)

  • 어익수
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.192-197
    • /
    • 1998
  • This study has been focused on the selection of optimal electric motor load, which takes a lot of portions of motor driving factor in the building. Based on the past design data for existing electric motor load and method of calculation, it is known that in general electric machine load has been estimated excessively. For the accurate calculation, it is important apply to motor driving factor to be actually provided.

  • PDF

Electromagnetic Field Analysis for Basic Estimation of Power Induction Voltage (전력선 유도전압 기초 산출을 위한 전자계 해석)

  • Lee, Sang-Mu;Eun, Chang-Soo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.5
    • /
    • pp.60-68
    • /
    • 2010
  • The calculation method of induction voltage is abbreviately by the Ohm's law including Carson-Pollaczek's equation for mutual inductance estimation and various shielding effect coefficients. This method is mainly scoped to 60㎐. power source and the inducing/induced object positioned on the air, and the dimension of shielding material is not thoroughly reflected. In this paper, more general method of calculation is scrutinized through electromagnetic wave propagation principles. Electromagnetic force as a voltage in the spot generating from the source is evaluated according to the position of the source and object, especially their relationship with earth surface as boundary line and independent to source propagation frequency. And this method intends to consider the material specification of each object in the induction field.