• 제목/요약/키워드: calculation method

검색결과 7,803건 처리시간 0.044초

RTS법의 개요 및 프로그램 소개 (Introduction of RTS Method and Load Calculation Program)

  • 김강산;김용찬;오명도
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1067-1072
    • /
    • 2008
  • This paper introduces the RTS method developed by the ASHRAE. In addition, a load calculation program was developed based on the RTS method and then the calculation logic and procedure are explained in detail. The developed program was designed to allow easy and precise predictions of the building load.

  • PDF

RTS 법의 개요 및 프로그램 소개 (Introduction of RTS Method and Load Calculation Program)

  • 김강산;김용찬;오명도
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.519-524
    • /
    • 2006
  • This paper introduces the RTS method developed by the ASHRAE. In addition, a load calculation program was developed based on the RTS method and then the calculation logic and procedure are explained in detail. The developed program was designed to allow easy and precise predictions of the building load.

  • PDF

Analysis of an HTS coil for large scale superconducting magnetic energy storage

  • Lee, Ji-Young;Lee, Seyeon;Choi, Kyeongdal;Park, Sang Ho;Hong, Gye-Won;Kim, Sung Soo;Lee, Ji-Kwang;Kim, Woo-Seok
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권2호
    • /
    • pp.45-49
    • /
    • 2015
  • It has been well known that a toroid is the inevitable shape for a high temperature superconducting (HTS) coil as a component of a large scale superconducting magnetic energy storage system (SMES) because it is the best option to minimize a magnetic field intensity applied perpendicularly to the HTS wires. Even though a perfect toroid coil does not have a perpendicular magnetic field, for a practical toroid coil composed of many HTS pancake coils, some type of perpendicular magnetic field cannot be avoided, which is a major cause of degradation of the HTS wires. In order to suggest an optimum design solution for an HTS SMES system, we need an accurate, fast, and effective calculation for the magnetic field, mechanical stresses, and stored energy. As a calculation method for these criteria, a numerical calculation such as an finite element method (FEM) has usually been adopted. However, a 3-dimensional FEM can involve complicated calculation and can be relatively time consuming, which leads to very inefficient iterations for an optimal design process. In this paper, we suggested an intuitive and effective way to determine the maximum magnetic field intensity in the HTS coil by using an analytic and statistical calculation method. We were able to achieve a remarkable reduction of the calculation time by using this method. The calculation results using this method for sample model coils were compared with those obtained by conventional numerical method to verify the accuracy and availability of this proposed method. After the successful substitution of this calculation method for the proposed design program, a similar method of determining the maximum mechanical stress in the HTS coil will also be studied as a future work.

수분 섭취 및 배설량의 측정방법에 관한 연구 (A Study on Fluid Intake and Output Measurements)

  • 최스미;양영희;정연
    • 대한간호학회지
    • /
    • 제25권1호
    • /
    • pp.88-98
    • /
    • 1995
  • The Fluid and electrolytes balance in the body is of critical importance in maintaining good health. When the fluid and electrolyte imbalance is present, patients are in great danger. They must be assessed immediately by a nurse so that appropriate treatment can be started as soon as possible. Patients' fluid intake and output records contain highly important information for the diagnosis and treatment of fluid imbalance, but, these records are often inaccurate and the method of recording the fluid intake is not universal for every hospital. Be-cause they are few quantitative measurements of a patient's hydration, the need to improve the accuracy of fluid intake records is very important. However, very few studies have been done to investigate the accuracy of measurements of patients' fluid intake and output. The purpose of this study was to investigate the methods used for calculation of fluid intake which is most similar to fluid output in normal adults and hospitalized patients. This study focused on three different calculation methods for fluid intake and compared these to fluid output and developed suggestions as to the ideal way to record fluid in-take. Data for 43 hospitalized patients and 37 normal adults were analyzed. The findings of this study are as follows ; 1) In normal adults, the daily intake of water which enteres by the oral route was 2415m1 (the first method of calculation). The daily intake of water in the form of pure water or some other beverage was 1365m1 (the third method of calculation) The daily intake of water including fresh fruits and vegetables, rice, porridges, and Me m which have water content more than 80% were 2186m1 (the second method of calculation). 2) The urine output of the normal adults was 1350m1. This apprroximates the amount of fluid an adult takes in the form of pure water. 3) In patient group, the total intake of water was 2550m1 (the first method of calculation). The in-take of water in the form of pure water or as some other beverage and IV fluid was 1661m1 (the third method of calculation). The daily in-take of water including foods which have high water content was 2356m1 (the second method of calculation). 4) The urine output of the patient's group was 1728m1. This approximates the amount of fluid an adult takes in the form of pure water. 5) Investigation of the method of calculation of the patient fluid intake showed that among the 31 hospitals studied, only eight use the third method of calculation which reflects the most close value to urine output. From the results obtained in this study, it was indicated that the amount of fluid taken in the form of pure water reflects the most close value to urine output. Therefore, it can be suggested that the third method of calculation which includes water in-take only in the form of pure water or beverage should be used as patients' fluid intake record.

  • PDF

무효 인상 경간에서 드로퍼 길이 계산 기법 (A dropper length calculation method of the elevating span in overlap area)

  • 권삼영;이기원;조용현
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1503-1510
    • /
    • 2011
  • The dropper length calculation method about the normal same encumbrance spans is well known independent to whether the pre-sag is given or not. But, the dropper length calculation method for the elevating span which consists in the end area of a tensioning section and normally consists with overlaps is not well known. In this study, firstly, we investigate the dropper length calculation method about the elevating span whether the insulator is contained in or not, we also recognize the effect of dropper length due to the change of the take-off point. Secondly, we very this calculation method with a catenary sample data and check again with Gyeongbu HSL design data.

  • PDF

병행 배전선로에서의 통신선 유도전압 계산 (Calculation of an Induced Voltage on Telecommunication Lines in Parallel Distribution Lines)

  • 김현수;이상봉;여상민;김철환;류승헌;김성암;원봉주
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1688-1695
    • /
    • 2008
  • Recently, it is common in a distribution system of Korea Electric Power Corporation (KEPCO) to find instances where distribution lines are parallel. A traditional method of an induced voltage calculation is not suitable for parallel distribution lines. For more actual analysis of induced voltage on telecommunication lines in parallel distribution lines, a new calculation method is needed. This paper presents a new calculation method of an induced voltage on telecommunication line using equivalent ${\pi}$ circuits matrix in parallel distribution lines. The advantages of the calculation method are using actual neutral current value and not using screening factor for considering the overhead ground wire and the neutral wire. To verify the effectiveness and the accuracy of the method, various case studies are performed with EMTP(Electro-Magnetic Transients Program).

강박스 교량을 대상으로 한 구조계산서의 누락된 설계항목 검토 자동화 방법론 (A Method for Automatic Check of Omitted Design Item in Structural Calculation Document of Steel Box Bridges)

  • 박상일;안현정;김봉근;이상호
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.813-818
    • /
    • 2007
  • A method for automatic check of omitted design item in structural calculation document of steel box bridges is proposed. A method for automatic check of omitted design item in structural calculation document of steel box bridges is proposed. Information processing for the proposed method is divided into two steps: automatic generation of document structure in XML Schema Definition (XSD) format and extract omitted design items by using the XML Schema matching technique. The automatic omitted element filter is developed on the basis of the proposed method, and the accuracy of the developed module is examined with case study subjected to existing structural calculation document samples.

  • PDF

증발산량 산정기법에 따른 밭작물의 적정 관개량 모의 (Simulation of Optimum Irrigation Water of Upland Crops by Evapotranspiration Calculation Methods)

  • 김선주;이주용;김필식
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.271-274
    • /
    • 2003
  • The objectives of this study are for finding an optimal calculation method comparing observed evapotranspiration with calculated evapotranspiration by Blaney-Criddle, Penman and Penman-Monteith method which are used in many place of Korea. And after appling optimal calculation method, optimal irrigation is presented through calculation of effective rainfall and requirement water considering characteristics of region, crop and soil.

  • PDF

상정사고를 고려한 ATC 계산에 관한 연구 (A Study on the Available Transfer Capability(ATC) calculation with Contingency)

  • 정성원;황건호;김양일;김재현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.296-297
    • /
    • 2008
  • This paper proposed a methods to ATC calculation using energy function. In this paper, ATC was calculated as PTDF, LODF, RPF and Energy Function method and calculation results of each methods was compared. Contingency ranking method decided the overloading branches by PI-index. As a result, a study proved the fast and accurate ATC calculation method considering contingency suggested in this paper.

  • PDF

경량전철 전력공급시스템의 용량 산정에 관한 연구 (A Study on Capacity Calculation of Power Supply System for Light Rail Transit)

  • 백병산;서광덕;김종구
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.696-703
    • /
    • 2000
  • This paper describes the capacity calculation of power supply system for light Rail Transit Three factors are considered for the design i.e. substation arrangements, line configuration and substation power capacity. In this study, we considered all of them for capacity calculation of power supply system for LRT. At first DC-fed-traction system is introduced on an outline, a characteristics of train and fed network, and design method of substation arrangements. Optimal design procedures are described, and program for capacity calculation of the system is presented. In addition, the computer simulated results are computed with the conventional simple calculation method.

  • PDF